MCMin Cao

Min Cao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Min Cao has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Ring type furnace integrated into DAC chamber for stable and uniform sample heating up to 2000 K

    by Muyun Han, Wenhui Liu, Min Cao, Weichao Li, Dawei Jiang, Yonghao Han, Chunxiao Gao

    The diamond anvil cell is a powerful tool for investigating material behavior under extreme pressure and temperature, but achieving efficient and uniform heating remains challenging. This study introduces a ring-type furnace integrated into a gasket with a metal–insulator–metal sandwich structure, using tantalum (Ta) for heating, tungsten (W) for electrodes, and mica-ceramic powder for insulation, enabling stable and uniform heating up to 2000 K. A calibration method combining thermocouple data and finite element simulations ensures accurate temperature measurement. Experimental validation shows that the furnace maintains optical access for spectroscopic measurements and supports in situ conductivity characterization under high-pressure and high-temperature conditions. This advancement provides a robust platform for multi-physics experiments under extreme conditions.


  • Open Access

    Sample heating above 1400 K in a diamond anvil cell

    by Min Cao, Dawei Jiang, Muyun Han, Yang Gao, Yonghao Han, Chunxiao Gao

    In high-pressure experimental methods, sample heating in the pressure chamber of a diamond anvil cell is an important topic, and numerous efforts have been made to improve and develop new technologies. In this paper, we propose a new type of internal resistance heating technique, the composite heating gasket, prepared by integrating an annular heater into the sample chamber for direct heating of the sample. As the effective heating area covers the entire pressure chamber wall, a relatively quasi-uniform temperature field is formed within the sample chamber. At the same time, the integration design reduces the risk of diamond oxidation and enables direct measurement of the spectroscopic properties of samples at high temperatures. The preparation of the composite heating gasket is simple and repeatable, and its heating performance is stable at temperatures above 1400 K. When the sample diameter is 210 μm and no thermal insulation is used, the diameter of the temperature zone in which the temperature difference is less than 10 and 20 K exceeds 120 and 170 μm, respectively. The composite heating gasket represents a significant advancement in providing a uniform temperature field for in situ measurements with diamond anvil cells at high pressure and temperature.


  • In situ temperature measurement in the pressure chamber of diamond anvil cell

    by Min Cao, Dawei Jiang, Muyun Han, Yang Gao, Yonghao Han, Chunxiao Gao

    The measurements of temperature directly influence the reasonability of experiments at high pressure and high temperature. In this article, we proposed a new integration design, the built-in thermocouple, for in situ temperature measurements in high-pressure–high-temperature experiments by fusing the characteristics of thermocouples and diamond anvil cells together. By integrating an S-type thermocouple inside the gasket of a diamond anvil cell, we successfully measured the temperature of the sample straight inside the pressure chamber at high pressure and high temperature. The setup underwent multiple experimental tests using internal and external heating techniques, the results of which revealed its capability to directly characterize the temperature of the sample with comparable accuracy and reliability to that of the typical external thermocouple setup. The proposed setup has also resolved the issue of the discrepancy of temperatures inside and outside the sample chamber and enormously expedited the temperature measurements by significantly reducing the response time of the thermocouple. In conclusion, the built-in thermocouple is a promising approach toward high-efficiency, in situ temperature measurements under extreme conditions.


  • Open Access

    Pressure-induced ionic–polaronic–ionic transition in LaAlO3

    by Xingxing Zhao, Jinqun Cai, Dawei Jiang, Min Cao, Lin Zhao, Yonghao Han

    Combining alternate-current impedance spectrum measurement and first-principle calculations, we thoroughly analyzed the electrical transport behavior of LaAlO3 under high pressure. A pressure-induced ionic–polaronic–ionic transition has been discovered through impedance spectroscopy measurements. Through first-principle calculations, we have elucidated the physical origin of the emergence of polaronic conduction, which results from the distortion of electron density background around Al and O atoms. Furthermore, the discontinuous changes in the starting frequency of ion migration fW, relaxation frequency fb, and ionic resistance Ri have been found at around 13.2 GPa, which can be ascribed to the phase transition of LaAlO3 from rhombohedral to cubic phase. Pressure can enhance the migration of O2− ions, causing an increase in the ionic conductivity of LaAlO3. This research will deepen our comprehension on the ion migration in solid electrolytes.


  • Open Access

    Radial crystallization difference of melt‐spun polypropylene fiber along spinning line

    by Dan Pan, Houkang He, Junfen Sun, Min Cao, Zongyi Qin, Long Chen

    The radial crystallization difference of polypropylene (PP) fiber along spinning line was investigated via synchrotron radiation microbeam X‐ray diffraction (μ‐XRD) analysis for the first time. Running fibers were collected at different spinning line positions to study its radial crystallization difference. The distribution of crystallinity, crystal form, and crystal size of PP fiber were obtained based on peak deconvolution. The relation between radial crystallization difference and processing condition was also investigated. The results indicate that the crystallinity of PP in the center region is found higher than the surface due to the radial temperature gradient during melt spinning, and the structure of fiber is highly sensitive to the radial temperature gradient. The crystallinity increased along spinning line and reaches a steady rate after 50 cm of spinning line position. The crystallite size increased before 50 cm of spinning line position and has a slight decrease after 50 cm due to the growth and splitting of crystal. These results display a 2D view of crystallization development of fiber during the melt spinning and give us a basic knowledge about the relation between structure evolution and processing conditions both in axis and radial directions. © 2018 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2019, 136, 47175.