Martina Zaguini Francisco
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Martina Zaguini Francisco has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Bruno Hochhegger
Department of Radiology, University of Florida, Gainesville, USA
2 shared publications - Guilherme Watte
Department of Respiratory Medicine and Thoracic Surgery, Irmandade da Santa Casa de Misericordia de Porto Alegre, R. Sarmento Leite, 245, Porto Alegre, 90050-170, Brazil
2 shared publications - Stephan Altmayer
Department of Radiology, Stanford University School of Medicine, Stanford, CA
2 shared publications - Ana Amelia Raupp
Department of Nuclear Medicine, Hospital Mae de Deus, Av. Jose de Alencar 286, Porto Alegre 90880-481, Brazil
1 shared publication - Bahram Mohajer
Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, USA
1 shared publication - Carlos Alberto Campello
School of Medicine, Universidade Federal do Mato Grosso, Cuiabá, Brazil
1 shared publication
Latest Publications
- Open Access
Detection of Liver Lesions in Colorectal Cancer Patients Using 18F-FDG PET/CT Dual-Time-Point Scan Imaging
Objective: The aim of this study was to evaluate the diagnostic performance of dual-time-point fluorine-18-fluorodeoxyglucose positron emission computed tomography/computed tomography (18F-FDG PET/CT) compared to conventional early imaging for detecting colorectal liver metastases (CRLM) in colorectal cancer (CRC) patients. Methods: One hundred twenty-four consecutive CRC patients underwent dual-time-point imaging scans on a retrospective basis. Histopathological confirmation and/or clinical follow-up were accepted as the gold standard. Standard uptake values (SUV), signal-to-noise ratio (SNR), retention index (RI), tumor-to-normal liver ratio (TNR), and lesion sizes were measured for early and delayed PET scans. The diagnostic performance of early and delayed images was calculated on a per-patient basis and compared using McNemar’s test. Results: Among the 124 patients, 57 (46%) had CRLM, 6 (4.8%) had benign lesions, and 61 (49.2%) had no concerning lesions detected. Smaller CRLM lesions (3) showed significantly higher uptake in the delayed scans relative to early imaging (p < 0.001). The SUV and TNR increased significantly in delayed imaging of all metastatic lesions (p < 0.001). The retention index of all CRLM was high (40.8%), especially for small lesions (54.8%). A total of 177 lesions in delayed images and 124 in standard early images were identified. In a per-patient analysis, delayed imaging had significantly higher sensitivity (100% vs. 87.7%) and specificity (91.0% vs. 94.0%) compared to early imaging (p-value = 0.04). Conclusions: The detection of liver lesions using dual-time-point PET/CT scan improves the sensitivity and specificity for the detection of colorectal liver metastasis.
Open AccessDetection of Liver Lesions in Colorectal Cancer Patients Using 18F-FDG PET/CT Dual-Time-Point Scan Imaging
Objective: The aim of this study was to evaluate the diagnostic performance of dual-time-point fluorine-18-fluorodeoxyglucose positron emission computed tomography/computed tomography (18F-FDG PET/CT) compared to conventional early imaging for detecting colorectal liver metastases (CRLM) in colorectal cancer (CRC) patients. Methods: One hundred twenty-four consecutive CRC patients underwent dual-time-point imaging scans on a retrospective basis. Histopathological confirmation and/or clinical follow-up were accepted as the gold standard. Standard uptake values (SUV), signal-to-noise ratio (SNR), retention index (RI), tumor-to-normal liver ratio (TNR), and lesion sizes were measured for early and delayed PET scans. The diagnostic performance of early and delayed images was calculated on a per-patient basis and compared using McNemar’s test. Results: Among the 124 patients, 57 (46%) had CRLM, 6 (4.8%) had benign lesions, and 61 (49.2%) had no concerning lesions detected. Smaller CRLM lesions (3) showed significantly higher uptake in the delayed scans relative to early imaging (p < 0.001). The SUV and TNR increased significantly in delayed imaging of all metastatic lesions (p < 0.001). The retention index of all CRLM was high (40.8%), especially for small lesions (54.8%). A total of 177 lesions in delayed images and 124 in standard early images were identified. In a per-patient analysis, delayed imaging had significantly higher sensitivity (100% vs. 87.7%) and specificity (91.0% vs. 94.0%) compared to early imaging (p-value = 0.04). Conclusions: The detection of liver lesions using dual-time-point PET/CT scan improves the sensitivity and specificity for the detection of colorectal liver metastasis.
- 26 June 2023
- Published by Springer Nature in Abdominal Radiology
- Vol. 48 (10) , 3114-3126
Machine learning for malignant versus benign focal liver lesions on US and CEUS: a meta-analysis
Objectives To perform a meta-analysis of the diagnostic performance of learning (ML) algorithms (conventional and deep learning algorithms) for the classification of malignant versus benign focal liver lesions (FLLs) on US and CEUS. Methods Available databases were searched for relevant published studies through September 2022. Studies met eligibility criteria if they evaluate the diagnostic performance of ML for the classification of malignant and benign focal liver lesions on US and CEUS. The pooled per-lesion sensitivities and specificities for each modality with 95% confidence intervals were calculated. Results A total of 8 studies on US, 11 on CEUS, and 1 study evaluating both methods met the inclusion criteria with a total of 34,245 FLLs evaluated. The pooled sensitivity and specificity of ML for the malignancy classification of FLLs were 81.7% (95% CI, 77.2–85.4%) and 84.8% (95% CI, 76.0–90.8%) for US, compared to 87.1% (95% CI, 81.8–91.0%) and 87.0% (95% CI, 83.1–90.1%) for CEUS. In the subgroup analysis of studies that evaluated deep learning algorithms, the sensitivity and specificity of CEUS (n = 4) increased to 92.4% (95% CI, 88.5–95.0%) and 88.2% (95% CI, 81.1–92.9%). Conclusions The diagnostic performance of ML algorithms for the malignant classification of FLLs was high for both US and CEUS with overall similar sensitivity and specificity. The similar performance of US may be related to the higher prevalence of DL models in that group. Graphical abstract
- 26 June 2023
- Published by Springer Nature in Abdominal Radiology
- Vol. 48 (10) , 3114-3126
Machine learning for malignant versus benign focal liver lesions on US and CEUS: a meta-analysis
Objectives To perform a meta-analysis of the diagnostic performance of learning (ML) algorithms (conventional and deep learning algorithms) for the classification of malignant versus benign focal liver lesions (FLLs) on US and CEUS. Methods Available databases were searched for relevant published studies through September 2022. Studies met eligibility criteria if they evaluate the diagnostic performance of ML for the classification of malignant and benign focal liver lesions on US and CEUS. The pooled per-lesion sensitivities and specificities for each modality with 95% confidence intervals were calculated. Results A total of 8 studies on US, 11 on CEUS, and 1 study evaluating both methods met the inclusion criteria with a total of 34,245 FLLs evaluated. The pooled sensitivity and specificity of ML for the malignancy classification of FLLs were 81.7% (95% CI, 77.2–85.4%) and 84.8% (95% CI, 76.0–90.8%) for US, compared to 87.1% (95% CI, 81.8–91.0%) and 87.0% (95% CI, 83.1–90.1%) for CEUS. In the subgroup analysis of studies that evaluated deep learning algorithms, the sensitivity and specificity of CEUS (n = 4) increased to 92.4% (95% CI, 88.5–95.0%) and 88.2% (95% CI, 81.1–92.9%). Conclusions The diagnostic performance of ML algorithms for the malignant classification of FLLs was high for both US and CEUS with overall similar sensitivity and specificity. The similar performance of US may be related to the higher prevalence of DL models in that group. Graphical abstract