Hao Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hao Cheng has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Dan Ye
China Electronic Product Reliability and Environment Test Research Institute
1 shared publication- Kexian Ren
Aeronautic Institute of Xiangyang, Xiangyang 441000, China
1 shared publication Kun Zheng
China Electronic Product Reliability and Environment Test Research Institute
1 shared publication- Leixin Wang
School of Aeronautical Science and Engineering, Beihang University, Beijing 100191, China
1 shared publication Rui Deng
China Electronic Product Reliability and Environment Test Research Institute
1 shared publicationTongzhi Yang
Beihang University
1 shared publication
Latest Publications
- Open Access
- 1 May 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3231 (1)
Optimization of the hybrid cooling mode of the liquid pump and compressor
To improve the energy utilization efficiency of data center cooling systems, this study constructed and experimentally investigated a hybrid cooling system that integrates a pump-driven loop heat pipe with vapor compression refrigeration. The research focuses on optimizing the switching logic and load distribution strategy between natural cooling and mechanical refrigeration modes under hybrid cooling operation. The results show that by appropriately matching cooling capacity and extending the operating duration of the natural cooling mode, compressor power consumption can be significantly reduced. Compared to the single vapor compression cooling mode, the hybrid cooling mode improves the overall system coefficient of performance by 8.2%–38.5%, with more pronounced energy-saving effects at lower ambient temperatures. Furthermore, the study confirms that dynamically adjusting the cooling contribution ratio of natural cooling from 69% to 20% as the outdoor temperature increases can effectively reduce the total energy consumption of the system.
- 1 May 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3231 (1)
Open AccessOptimization of the hybrid cooling mode of the liquid pump and compressor
To improve the energy utilization efficiency of data center cooling systems, this study constructed and experimentally investigated a hybrid cooling system that integrates a pump-driven loop heat pipe with vapor compression refrigeration. The research focuses on optimizing the switching logic and load distribution strategy between natural cooling and mechanical refrigeration modes under hybrid cooling operation. The results show that by appropriately matching cooling capacity and extending the operating duration of the natural cooling mode, compressor power consumption can be significantly reduced. Compared to the single vapor compression cooling mode, the hybrid cooling mode improves the overall system coefficient of performance by 8.2%–38.5%, with more pronounced energy-saving effects at lower ambient temperatures. Furthermore, the study confirms that dynamically adjusting the cooling contribution ratio of natural cooling from 69% to 20% as the outdoor temperature increases can effectively reduce the total energy consumption of the system.
- Open Access
- 24 June 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (13) , 7472
Modeling and Performance Analysis of a Pump-Driven Chip-Level Two-Phase Cooling System in Data Centers
As a powerful solution for heat dissipation in data centers, chip-level cooling continues to capture escalating attention in research and application domains. To accurately analyze system performance, identify potential avenues for system optimization, and inform future practical applications, we developed a steady-state, one-dimensional mathematical model for a novel pump-driven chip-level two-phase cooling system (PCTCS). This model was constructed based on our previous study and was confirmed against existing experimental data. Our simulations scrutinized PCTCS performance under default conditions and investigated the effects of key parameters, such as refrigerant type, condenser vertical positioning, and cooling water temperature. Results showed that the system could manage an 80 W power output from each CPU while maintaining CPU temperatures around 79 °C at a cooling water temperature of 45 °C. We discovered the choice of refrigerant had a significant impact on performance, with R32 outperforming R134a and R113. While the vertical position of the condenser influenced the PCTCS’s internal parameters, its overall impact on system performance was negligible. Moreover, provided the chip temperature remained within a safe range, our study found that increasing the cooling water temperature improved the energy efficiency ratio of the refrigerant pump and reduced the temperature difference between the chips and the cold source.
- 24 June 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (13) , 7472
Open AccessModeling and Performance Analysis of a Pump-Driven Chip-Level Two-Phase Cooling System in Data Centers
As a powerful solution for heat dissipation in data centers, chip-level cooling continues to capture escalating attention in research and application domains. To accurately analyze system performance, identify potential avenues for system optimization, and inform future practical applications, we developed a steady-state, one-dimensional mathematical model for a novel pump-driven chip-level two-phase cooling system (PCTCS). This model was constructed based on our previous study and was confirmed against existing experimental data. Our simulations scrutinized PCTCS performance under default conditions and investigated the effects of key parameters, such as refrigerant type, condenser vertical positioning, and cooling water temperature. Results showed that the system could manage an 80 W power output from each CPU while maintaining CPU temperatures around 79 °C at a cooling water temperature of 45 °C. We discovered the choice of refrigerant had a significant impact on performance, with R32 outperforming R134a and R113. While the vertical position of the condenser influenced the PCTCS’s internal parameters, its overall impact on system performance was negligible. Moreover, provided the chip temperature remained within a safe range, our study found that increasing the cooling water temperature improved the energy efficiency ratio of the refrigerant pump and reduced the temperature difference between the chips and the cold source.