Showchien Hsieh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Showchien Hsieh has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
John Dunn
GlaxoSmithKline, Inc., Research Triangle Park, NC 27709, USA
1 shared publicationKevin Koch
GlaxoSmithKline, Inc., Research Triangle Park, NC 27709, USA
1 shared publicationTom Tobien
Leap Technologies, P.O. Box 969, Carrboro, NC 27510, USA
1 shared publication
Latest Publications
- 6 January 2004
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 18 (3) , 285-292
Increasing throughput of parallel on‐line extraction liquid chromatography/electrospray ionization tandem mass spectrometry system for GLP quantitative bioanalysis in drug development
An approach is described with turbulent flow on‐line extraction liquid chromatography/electrospray ionization tandem mass spectrometry (LC‐ESI‐MS/MS) for GLP quantitative bioanalysis of a drug candidate. Two systems were built in‐house with standard laboratory parts and equipments. One system consisted of one gradient HPLC pump, one isocratic pump, one ten‐port valve, two turbulent flow columns, one analytical column, one autosampler and one mass spectrometer. Using this system, an injection‐to‐injection cycle time of 0.8 min was achieved. By adding an additional valve, another analytical column and an isocratic pump, the injection‐to‐injection cycle time decreased to 0.4 min. Validation results from the two systems showed that precision and accuracy were acceptable for GLP quantitative analyses. The system was utilized to support sample bioanalysis of a drug candidate in a first‐time in‐human clinical trial. Copyright © 2004 John Wiley & Sons, Ltd.
- 6 January 2004
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 18 (3) , 285-292
Increasing throughput of parallel on‐line extraction liquid chromatography/electrospray ionization tandem mass spectrometry system for GLP quantitative bioanalysis in drug development
An approach is described with turbulent flow on‐line extraction liquid chromatography/electrospray ionization tandem mass spectrometry (LC‐ESI‐MS/MS) for GLP quantitative bioanalysis of a drug candidate. Two systems were built in‐house with standard laboratory parts and equipments. One system consisted of one gradient HPLC pump, one isocratic pump, one ten‐port valve, two turbulent flow columns, one analytical column, one autosampler and one mass spectrometer. Using this system, an injection‐to‐injection cycle time of 0.8 min was achieved. By adding an additional valve, another analytical column and an isocratic pump, the injection‐to‐injection cycle time decreased to 0.4 min. Validation results from the two systems showed that precision and accuracy were acceptable for GLP quantitative analyses. The system was utilized to support sample bioanalysis of a drug candidate in a first‐time in‐human clinical trial. Copyright © 2004 John Wiley & Sons, Ltd.