Antonio G. Cabrera
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Antonio G. Cabrera has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Athar M. Qureshi
Texas Children’s Hospital/Baylor College of Medicine, Houston (A.M.Q.).
2 shared publications - Iki Adachi
Division of Congenital Heart Surgery, Michael E. DeBakey Department of Surgery, Texas Children's Hospital, Baylor College of Medicine, 6651 Main St, Houston, TX 77030
2 shared publications - Aamir Jeewa
Labatt Family Heart Centre, Division of Pediatric Cardiology, Department of Pediatrics, University of Toronto, Hospital for Sick Children, Toronto, Canada
1 shared publication - Autumn M. McKnite
Division of Clinical Pharmacology, Department of Pediatrics University of Utah Salt Lake City Utah USA
1 shared publication Barb Elias
Department of Pediatric Cardiology, Baylor College of Medicine, Texas Children’s Hospital, Houston, Texas, USA
1 shared publication- Barbara Elias
Department of Government & Legal Studies, Bowdoin College, Brunswick, GA, USA
1 shared publication
Latest Publications
- 22 June 2023
- Published by Wiley in Pharmacotherapy: The Journal of Human Pharmacology and Drug Therapy
- Vol. 43 (7) , 650-658
External assessment and refinement of a population pharmacokinetic model to guide tacrolimus dosing in pediatric heart transplant
Study Objective: The immunosuppressant tacrolimus is a first‐line agent to prevent graft rejection following pediatric heart transplant; however, it suffers from extensive inter‐patient variability and a narrow therapeutic window. Personalized tacrolimus dosing may improve transplant outcomes by more efficiently achieving and maintaining therapeutic tacrolimus concentrations. We sought to externally validate a previously published population pharmacokinetic (PK) model that was constructed with data from a single site.Data Source: Data were collected from Seattle, Texas, and Boston Children's Hospitals, and assessed using standard population PK modeling techniques in NONMEMv7.2.Main Results: While the model was not successfully validated for use with external data, further covariate searching identified weight (p < 0.0001 on both volume and elimination rate) as a model‐significant covariate. This refined model acceptably predicted future tacrolimus concentrations when guided by as few as three concentrations (median prediction error = 7%; median absolute prediction error = 27%).Conclusion: These findings support the potential clinical utility of a population PK model to provide personalized tacrolimus dosing guidance.
- 22 June 2023
- Published by Wiley in Pharmacotherapy: The Journal of Human Pharmacology and Drug Therapy
- Vol. 43 (7) , 650-658
External assessment and refinement of a population pharmacokinetic model to guide tacrolimus dosing in pediatric heart transplant
Study Objective: The immunosuppressant tacrolimus is a first‐line agent to prevent graft rejection following pediatric heart transplant; however, it suffers from extensive inter‐patient variability and a narrow therapeutic window. Personalized tacrolimus dosing may improve transplant outcomes by more efficiently achieving and maintaining therapeutic tacrolimus concentrations. We sought to externally validate a previously published population pharmacokinetic (PK) model that was constructed with data from a single site.Data Source: Data were collected from Seattle, Texas, and Boston Children's Hospitals, and assessed using standard population PK modeling techniques in NONMEMv7.2.Main Results: While the model was not successfully validated for use with external data, further covariate searching identified weight (p < 0.0001 on both volume and elimination rate) as a model‐significant covariate. This refined model acceptably predicted future tacrolimus concentrations when guided by as few as three concentrations (median prediction error = 7%; median absolute prediction error = 27%).Conclusion: These findings support the potential clinical utility of a population PK model to provide personalized tacrolimus dosing guidance.
- 7 April 2022
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 41 (4) , S500
Challenges in Using ICD-10 Codes for Case Ascertainment in Pediatric Heart Failure
- 7 April 2022
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 41 (4) , S500
Challenges in Using ICD-10 Codes for Case Ascertainment in Pediatric Heart Failure
- 7 July 2021
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 68 (4) , 584-591
Does Cardiac Catheterization Facilitate Hemodynamic Optimization of Pediatric Patients on Continuous-Flow Ventricular Assist Devices?
Understanding optimal ventricular assist device (VAD) parameters for pediatric patients is valuable given the inherent issue of patient-device size mismatch and heterogeneous cardiac anatomy in children. We evaluated our center’s experience of continuous-flow VAD (CF-VAD) optimization using cardiac catheterization. We performed a retrospective analysis of all patients on CF-VAD support who underwent hemodynamic heart catheterization from 2013 to 2018. Fifteen patients had 16 hemodynamic catheterizations performed. The indications for hemodynamic optimization by catheterization included clinical signs of heart failure while on CF-VAD (9 of 16, 56%), pretransplant evaluation of pulmonary hypertension (2 of 16, 13%), or assessment of myocardial recovery (5 of 16, 31%). The median age at catheterization was 12 years (interquartile range: 8–16). Median baseline speed of device was 2333 ± 253 rotations per minute. The goal was to find the speed at which optimal hemodynamics were achieved, defined by low wedge pressure with an acceptable central venous pressure. Of the 16 catheterizations, there were 9 (56%) speed increases to achieve optimal hemodynamics and 5 (33%) speed decreases for hemodynamic optimization or for potential explant. The speed was not changed in 2 (13%) catheterizations as the patients were determined to be at an optimal hemodynamic state. Overall, VAD settings were optimized in 75% (14 of 16) of hemodynamic catheterizations. There were no adverse events related to catheterization. Thus, we conclude that catheterization-based hemodynamic assessment is safe and effective for optimizing VAD speed and provides guidance on medical management in children supported on CF-VAD.
- 7 July 2021
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 68 (4) , 584-591
Does Cardiac Catheterization Facilitate Hemodynamic Optimization of Pediatric Patients on Continuous-Flow Ventricular Assist Devices?
Understanding optimal ventricular assist device (VAD) parameters for pediatric patients is valuable given the inherent issue of patient-device size mismatch and heterogeneous cardiac anatomy in children. We evaluated our center’s experience of continuous-flow VAD (CF-VAD) optimization using cardiac catheterization. We performed a retrospective analysis of all patients on CF-VAD support who underwent hemodynamic heart catheterization from 2013 to 2018. Fifteen patients had 16 hemodynamic catheterizations performed. The indications for hemodynamic optimization by catheterization included clinical signs of heart failure while on CF-VAD (9 of 16, 56%), pretransplant evaluation of pulmonary hypertension (2 of 16, 13%), or assessment of myocardial recovery (5 of 16, 31%). The median age at catheterization was 12 years (interquartile range: 8–16). Median baseline speed of device was 2333 ± 253 rotations per minute. The goal was to find the speed at which optimal hemodynamics were achieved, defined by low wedge pressure with an acceptable central venous pressure. Of the 16 catheterizations, there were 9 (56%) speed increases to achieve optimal hemodynamics and 5 (33%) speed decreases for hemodynamic optimization or for potential explant. The speed was not changed in 2 (13%) catheterizations as the patients were determined to be at an optimal hemodynamic state. Overall, VAD settings were optimized in 75% (14 of 16) of hemodynamic catheterizations. There were no adverse events related to catheterization. Thus, we conclude that catheterization-based hemodynamic assessment is safe and effective for optimizing VAD speed and provides guidance on medical management in children supported on CF-VAD.
- Open Access
- 1 March 2019
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 107 (3) , 829-836
Ventricular Assist Device Support: Single Pediatric Institution Experience Over Two Decades
- 1 March 2019
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 107 (3) , 829-836
Open AccessVentricular Assist Device Support: Single Pediatric Institution Experience Over Two Decades
- 1 January 2018
- Published by Elsevier
- p. 95-103
Systolic and Diastolic Function
- Open Access
- 1 March 2014
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 60 (2) , 211-215
Anticoagulation Therapy Trends in Children Supported by Ventricular Assist Devices
Ventricular assist device (VAD) use in children has increased dramatically. There are currently few data regarding trends in anticoagulation management for pediatric VADs. A retrospective cohort study was conducted for patients with an International Classification of Diseases, Ninth Revision (ICD-9) code for VAD implantation from 2000 to 2011 from the Pediatric Health Information System database. Patient demographics, use of extracorporeal membrane oxygenation, orthotopic heart transplantation (OHT), disease states, and medications pertinent to the management of VAD anticoagulation were queried. Patients were grouped into 3 year time periods to evaluate trends in medication use over time. Four hundred sixty-six patients were identified with a median length of VAD therapy of 21 days (range 1-362 days). In-hospital mortality was 31.9%, and 54.5% underwent OHT. Length of VAD therapy and patients undergoing OHT increased, while mortality decreased. Patients received a median of two anticoagulant medications (range 0-6), one (range 0-4) antiplatelet medications, three (range 0-5) procoagulant medications, and one (range 0-3) antifibrinolytics. Patients received greater mean numbers of anticoagulant, procoagulant, antifibrinolytic, and antiplatelet agents, and the use of oral medications increased more than twofold over time. There is wide variability for in-hospital pediatric VAD anticoagulation management, with a significant increase in the use of oral agents in more recent years.
- 1 March 2014
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 60 (2) , 211-215
Open AccessAnticoagulation Therapy Trends in Children Supported by Ventricular Assist Devices
Ventricular assist device (VAD) use in children has increased dramatically. There are currently few data regarding trends in anticoagulation management for pediatric VADs. A retrospective cohort study was conducted for patients with an International Classification of Diseases, Ninth Revision (ICD-9) code for VAD implantation from 2000 to 2011 from the Pediatric Health Information System database. Patient demographics, use of extracorporeal membrane oxygenation, orthotopic heart transplantation (OHT), disease states, and medications pertinent to the management of VAD anticoagulation were queried. Patients were grouped into 3 year time periods to evaluate trends in medication use over time. Four hundred sixty-six patients were identified with a median length of VAD therapy of 21 days (range 1-362 days). In-hospital mortality was 31.9%, and 54.5% underwent OHT. Length of VAD therapy and patients undergoing OHT increased, while mortality decreased. Patients received a median of two anticoagulant medications (range 0-6), one (range 0-4) antiplatelet medications, three (range 0-5) procoagulant medications, and one (range 0-3) antifibrinolytics. Patients received greater mean numbers of anticoagulant, procoagulant, antifibrinolytic, and antiplatelet agents, and the use of oral medications increased more than twofold over time. There is wide variability for in-hospital pediatric VAD anticoagulation management, with a significant increase in the use of oral agents in more recent years.