Hanna Malygina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hanna Malygina has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- A. Alfonso Albero
Universitat de Barcelona
13 shared publications - A. B. Rodrigues
Institute of Physics, Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
13 shared publications - A. Battig
Technische Universität Dortmund
13 shared publications - A. Brossa Gonzalo
Universidade de Santiago de Compostela
13 shared publications - A. C. dos Reis
Centro Brasileiro de Pesquisas Físicas (CBPF)
13 shared publications - A. G. Downes
Université Savoie Mont Blanc
13 shared publications
Latest Publications
- Open Access
- 19 February 2026
- Published by Springer Nature in BMC Cancer
- Vol. 26 (1)
Clinical experience with an online adaptive radiotherapy for prostate cancer: successful treatment time optimization
Background: Online adaptive radiotherapy (oART) can provide dosimetric advantages by accounting for daily anatomic changes, potentially improving target coverage and sparing of organs at risk. However, clinical adoption is sometimes limited by concerns over increased per-session treatment time. In this single-center study, we present 1.5 years of clinical experience focused on reducing the oART session time for prostate cancer patients. Methods: We analyzed 1366 oART sessions from 69 prostate cancer patients treated on a Varian Ethos system between July 2023 and December 2024. We recorded (i) total session time — time between patient entry and exit from the treatment room, and (ii) adaptation time — time from start of the daily cone-beam-CT acquisition to completion of contour review/correction. We assessed the effects of two time-saving measures: automated contouring of the posterior rectal wall and installation of Varian HyperSight imaging. Statistical comparisons used the Mann–Whitney U test. Results: Automated posterior rectal wall contouring decreased mean adaptation time from 16.0 to 10.5 min ( $$p<0.001$$ ). Installation of HyperSight reduced mean total session time from 25.8 to 23.3 min ( $$p<0.001$$ ); the adaptation component improved by 0.5 min but not statistically significant ( $$p=0.053$$ ). We achieved a total session time of $$\leqslant 30$$ min for 93% of sessions. Conclusions: Cone-beam-CT-guided oART is feasible in routine prostate cancer practice. Our findings indicate that a 30-minute time slot is sufficient for most adaptive prostate cancer treatments, and a median total session time of 23 minutes can be reached through workflow and imaging optimization. Clinics considering oART should note that treatment time decreases with operator experience, and targeted measures can further reduce session duration.- 19 February 2026
- Published by Springer Nature in BMC Cancer
- Vol. 26 (1)
Open AccessClinical experience with an online adaptive radiotherapy for prostate cancer: successful treatment time optimization
Background: Online adaptive radiotherapy (oART) can provide dosimetric advantages by accounting for daily anatomic changes, potentially improving target coverage and sparing of organs at risk. However, clinical adoption is sometimes limited by concerns over increased per-session treatment time. In this single-center study, we present 1.5 years of clinical experience focused on reducing the oART session time for prostate cancer patients. Methods: We analyzed 1366 oART sessions from 69 prostate cancer patients treated on a Varian Ethos system between July 2023 and December 2024. We recorded (i) total session time — time between patient entry and exit from the treatment room, and (ii) adaptation time — time from start of the daily cone-beam-CT acquisition to completion of contour review/correction. We assessed the effects of two time-saving measures: automated contouring of the posterior rectal wall and installation of Varian HyperSight imaging. Statistical comparisons used the Mann–Whitney U test. Results: Automated posterior rectal wall contouring decreased mean adaptation time from 16.0 to 10.5 min ( $$p<0.001$$ ). Installation of HyperSight reduced mean total session time from 25.8 to 23.3 min ( $$p<0.001$$ ); the adaptation component improved by 0.5 min but not statistically significant ( $$p=0.053$$ ). We achieved a total session time of $$\leqslant 30$$ min for 93% of sessions. Conclusions: Cone-beam-CT-guided oART is feasible in routine prostate cancer practice. Our findings indicate that a 30-minute time slot is sufficient for most adaptive prostate cancer treatments, and a median total session time of 23 minutes can be reached through workflow and imaging optimization. Clinics considering oART should note that treatment time decreases with operator experience, and targeted measures can further reduce session duration. - Open Access
- 3 November 2025
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 15, 1662671
Daily online adaptation enhances target coverage in prostate cancer radiotherapy: a retrospective analysis
Introduction: Online adaptive radiotherapy aims to improve treatment quality by accounting for inter-fractional variation in anatomy. This study presents a quantitative comparison between adapted and non-adapted scheduled plans with identical margins in a real-world clinical setting. Methods: We retrospectively analyzed 422 fractions from 43 patients with prostate cancer treated with the Varian Ethos system. All patients received hypofractionated treatment with 3 Gy per fraction up to a cumulative dose of 60 Gy. For each fraction, the scheduled plan (planned on planning CT, calculated on synthetic CT derived from daily cone beam CT) was compared to the adapted plan (planned and calculated on actual daily anatomy) by means of several dose-volume metrics. Comparative statistics regarding dose-volume metrics were performed using Wilcoxon signed-rank test for paired data with a two-sided hypothesis. Results: Adapted plans delivered significantly better target coverage, conformality, and homo-geneity than scheduled plans. The constraints D95% ≥ 95% and V95% ≥ 95% were met in 418 out of 422 fractions with the adapted plan, compared to only 41%-84% of fractions with the scheduled plan. Median absolute improvements for these metrics ranged between 1.5 and 6.0 percentage points. Most organ-at-risk metrics remained unchanged or showed only minor differences. Interquartile ranges decreased across all metrics. Conclusions: Adaptation significantly improved target dose metrics compared to non-adapted plans, without compromising organs-at-risk sparing. Interquartile ranges were reduced for all metrics evidencing better repeatability of adapted plans.
- 3 November 2025
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 15, 1662671
Open AccessDaily online adaptation enhances target coverage in prostate cancer radiotherapy: a retrospective analysis
Introduction: Online adaptive radiotherapy aims to improve treatment quality by accounting for inter-fractional variation in anatomy. This study presents a quantitative comparison between adapted and non-adapted scheduled plans with identical margins in a real-world clinical setting. Methods: We retrospectively analyzed 422 fractions from 43 patients with prostate cancer treated with the Varian Ethos system. All patients received hypofractionated treatment with 3 Gy per fraction up to a cumulative dose of 60 Gy. For each fraction, the scheduled plan (planned on planning CT, calculated on synthetic CT derived from daily cone beam CT) was compared to the adapted plan (planned and calculated on actual daily anatomy) by means of several dose-volume metrics. Comparative statistics regarding dose-volume metrics were performed using Wilcoxon signed-rank test for paired data with a two-sided hypothesis. Results: Adapted plans delivered significantly better target coverage, conformality, and homo-geneity than scheduled plans. The constraints D95% ≥ 95% and V95% ≥ 95% were met in 418 out of 422 fractions with the adapted plan, compared to only 41%-84% of fractions with the scheduled plan. Median absolute improvements for these metrics ranged between 1.5 and 6.0 percentage points. Most organ-at-risk metrics remained unchanged or showed only minor differences. Interquartile ranges decreased across all metrics. Conclusions: Adaptation significantly improved target dose metrics compared to non-adapted plans, without compromising organs-at-risk sparing. Interquartile ranges were reduced for all metrics evidencing better repeatability of adapted plans.
- Open Access
- 29 October 2025
- Published by Springer Nature in Research Square
Clinical experience with an online adaptive radiotherapy for prostate cancer: successful treatment time optimization
Background: Online adaptive radiotherapy (oART) can provide dosimetric advantages by accounting for daily anatomic changes, potentially improving target coverage and sparing of organs at risk. However, clinical adoption is sometimes limited by concerns over increased per-session treatment time. In this single-center study, we present 1.5 years of clinical experience focused on reducing the oART session time for prostate cancer patients. Methods: We analyzed 1366 oART sessions from 69 prostate cancer patients treated on a Varian Ethos system between July 2023 and December 2024. We recorded (i) total session time — time between patient entry and exit from the treatment room, and (ii) adaptation time — time from start of the daily cone beam-CT acquisition to completion of contour review/correction. We assessed the effects of two time-saving measures: automated contouring of the posterior rectal wall and installation of Varian HyperSight imaging. Statistical compar isons used the Mann–Whitney U test. Results: Automated posterior rectal wall contouring decreased mean adapta tion time from 16.0 to 10.5 min (p < 0.001). Installation of HyperSight reduced mean total session time from 25.8 to 23.3 min (p < 0.001); the adaptation component improved by 0.5 min but not statistically significant (p = 0.053). We achieved a total session time of ⩽ 30 min for 93% of sessions. Conclusions: Cone-beam-CT-guided oART is feasible in routine prostate can cer practice. Our findings indicate that a 30-minute time slot is sufficient for most adaptive prostate cancer treatments, and a median total session time of 23 minutes can be reached through workflow and imaging optimization. Clin ics considering oART should note that treatment time decreases with operator experience, and targeted measures can further reduce session duration.
- 29 October 2025
- Published by Springer Nature in Research Square
Open AccessClinical experience with an online adaptive radiotherapy for prostate cancer: successful treatment time optimization
Background: Online adaptive radiotherapy (oART) can provide dosimetric advantages by accounting for daily anatomic changes, potentially improving target coverage and sparing of organs at risk. However, clinical adoption is sometimes limited by concerns over increased per-session treatment time. In this single-center study, we present 1.5 years of clinical experience focused on reducing the oART session time for prostate cancer patients. Methods: We analyzed 1366 oART sessions from 69 prostate cancer patients treated on a Varian Ethos system between July 2023 and December 2024. We recorded (i) total session time — time between patient entry and exit from the treatment room, and (ii) adaptation time — time from start of the daily cone beam-CT acquisition to completion of contour review/correction. We assessed the effects of two time-saving measures: automated contouring of the posterior rectal wall and installation of Varian HyperSight imaging. Statistical compar isons used the Mann–Whitney U test. Results: Automated posterior rectal wall contouring decreased mean adapta tion time from 16.0 to 10.5 min (p < 0.001). Installation of HyperSight reduced mean total session time from 25.8 to 23.3 min (p < 0.001); the adaptation component improved by 0.5 min but not statistically significant (p = 0.053). We achieved a total session time of ⩽ 30 min for 93% of sessions. Conclusions: Cone-beam-CT-guided oART is feasible in routine prostate can cer practice. Our findings indicate that a 30-minute time slot is sufficient for most adaptive prostate cancer treatments, and a median total session time of 23 minutes can be reached through workflow and imaging optimization. Clin ics considering oART should note that treatment time decreases with operator experience, and targeted measures can further reduce session duration.
- Open Access
- 25 August 2025
- Published by Springer Nature in Strahlentherapie und Onkologie
- Vol. 201 (12) , 1326
Correction to: Full bladder, empty rectum? Revisiting a paradigm in the era of adaptive radiotherapy
- 25 August 2025
- Published by Springer Nature in Strahlentherapie und Onkologie
- Vol. 201 (12) , 1326
Open AccessCorrection to: Full bladder, empty rectum? Revisiting a paradigm in the era of adaptive radiotherapy
- Open Access
- 15 July 2025
- Published by Springer Nature in Strahlentherapie und Onkologie
- Vol. 201 (11) , 1170-1184
Intra-adaptational changes in online adaptive radiotherapy: from the ideal to the real dose
Background and purpose: Online adaptive radiotherapy has demonstrated dosimetric benefits by accounting for interfractional organ variations. However, this study investigates the dosimetric impact of intra-adaptational anatomical changes that take place during the adaptation process. Methods: Our retrospective analysis was conducted on 155 fractions from 8 prostate cancer patients treated with adaptive radiotherapy using the Varian Ethos system (Varian, Palo Alto, California, USA). Various dose–volume metrics for the targets and organs at risk were assessed for (1) the non-adapted (an original plan on a pretreatment cone-beam CT [CBCT], acquired at the beginning of a treatment session), (2) the adapted (an adapted plan on a pretreatment CBCT), and (3) the delivered dose distributions (an adapted plan on a pre-irradiation CBCT acquired for patient position verification with recontoured organs). Results: For the target metrics, we quantitatively proved that the delivered dose distribution was still beneficial in comparison to the non-adapted one, despite the anatomical changes during the adaptation process. The bladder dose–volume metrics strongly depended on the bladder volume variations across the planning CT and both CBCTs, frequently showing improvement during the adaptation process as the bladder continued to fill. In contrast, no clear trend was observed for the rectum or posterior rectum wall metrics. In only a small fraction of sessions (up to 5% for most metrics) were the metric objectives not achieved with the delivered dose while they were achieved with the adapted one. Physiological reasons for these occurrences stemmed from meteorism occurring between pretreatment and pre-irradiation CBCTs. Conclusion: This study confirms that the dosimetric advantages of online adaptive radiotherapy persist in clinical practice, despite anatomical changes due to the time delay needed for the adaptation process.
- 15 July 2025
- Published by Springer Nature in Strahlentherapie und Onkologie
- Vol. 201 (11) , 1170-1184
Open AccessIntra-adaptational changes in online adaptive radiotherapy: from the ideal to the real dose
Background and purpose: Online adaptive radiotherapy has demonstrated dosimetric benefits by accounting for interfractional organ variations. However, this study investigates the dosimetric impact of intra-adaptational anatomical changes that take place during the adaptation process. Methods: Our retrospective analysis was conducted on 155 fractions from 8 prostate cancer patients treated with adaptive radiotherapy using the Varian Ethos system (Varian, Palo Alto, California, USA). Various dose–volume metrics for the targets and organs at risk were assessed for (1) the non-adapted (an original plan on a pretreatment cone-beam CT [CBCT], acquired at the beginning of a treatment session), (2) the adapted (an adapted plan on a pretreatment CBCT), and (3) the delivered dose distributions (an adapted plan on a pre-irradiation CBCT acquired for patient position verification with recontoured organs). Results: For the target metrics, we quantitatively proved that the delivered dose distribution was still beneficial in comparison to the non-adapted one, despite the anatomical changes during the adaptation process. The bladder dose–volume metrics strongly depended on the bladder volume variations across the planning CT and both CBCTs, frequently showing improvement during the adaptation process as the bladder continued to fill. In contrast, no clear trend was observed for the rectum or posterior rectum wall metrics. In only a small fraction of sessions (up to 5% for most metrics) were the metric objectives not achieved with the delivered dose while they were achieved with the adapted one. Physiological reasons for these occurrences stemmed from meteorism occurring between pretreatment and pre-irradiation CBCTs. Conclusion: This study confirms that the dosimetric advantages of online adaptive radiotherapy persist in clinical practice, despite anatomical changes due to the time delay needed for the adaptation process.
- Open Access
- 29 October 2024
- Published by Springer Nature in Strahlentherapie und Onkologie
- Vol. 201 (1) , 47-56
Full bladder, empty rectum? Revisiting a paradigm in the era of adaptive radiotherapy
Background and Purpose: Many patients find it challenging to comply with instructions regarding rectum and bladder filling during pelvic radiotherapy. With the implementation of online adaptive radiotherapy, the reproducibility of organ volumes is no longer a prerequisite. This study aims to analyze the sparing of the bladder and the posterior rectum wall (PRW) in conditions of full versus empty bladder and rectum. Methods: 280 fractions from 14 patients with prostate cancer who underwent adaptive radiotherapy using the Varian Ethos system were analyzed post-hoc. Various metrics for the bladder and PRW were correlated with respect to organ volume. Results: Our analysis quantitatively confirms the advantage of a full bladder during radiotherapy, as metrics V48Gy and V40Gy significantly inversely correlate with bladder filling for each patient individually. While bladder volume did not show a gradual decrease over the course of radiotherapy, it was observed to be higher during planning CT scans compared to treatment sessions. A full rectum condition either significantly improved (in 2 out of 7 patients) or at least did not impair (in 5 out of 7 patients) PRW sparing, as represented by the V30Gy metric, when patients were compared individually. The average V30Gy across all patients demonstrated a significant improvement in PRW sparing for the full rectum condition, with a $$p$$ -value of 0.039. Conclusion: Despite the implementation of adaptive therapy, maintaining a high bladder filling remains important. However, the recommendation for rectum filling can be abandoned, as reproducibility is not critical for adaptive radiotherapy and no dosimetric advantage per se is associated with an empty rectum. Patients may even be encouraged not to void their bowels shortly before treatment, as long as this is tolerated over the treatment session.- 29 October 2024
- Published by Springer Nature in Strahlentherapie und Onkologie
- Vol. 201 (1) , 47-56
Open AccessFull bladder, empty rectum? Revisiting a paradigm in the era of adaptive radiotherapy
Background and Purpose: Many patients find it challenging to comply with instructions regarding rectum and bladder filling during pelvic radiotherapy. With the implementation of online adaptive radiotherapy, the reproducibility of organ volumes is no longer a prerequisite. This study aims to analyze the sparing of the bladder and the posterior rectum wall (PRW) in conditions of full versus empty bladder and rectum. Methods: 280 fractions from 14 patients with prostate cancer who underwent adaptive radiotherapy using the Varian Ethos system were analyzed post-hoc. Various metrics for the bladder and PRW were correlated with respect to organ volume. Results: Our analysis quantitatively confirms the advantage of a full bladder during radiotherapy, as metrics V48Gy and V40Gy significantly inversely correlate with bladder filling for each patient individually. While bladder volume did not show a gradual decrease over the course of radiotherapy, it was observed to be higher during planning CT scans compared to treatment sessions. A full rectum condition either significantly improved (in 2 out of 7 patients) or at least did not impair (in 5 out of 7 patients) PRW sparing, as represented by the V30Gy metric, when patients were compared individually. The average V30Gy across all patients demonstrated a significant improvement in PRW sparing for the full rectum condition, with a $$p$$ -value of 0.039. Conclusion: Despite the implementation of adaptive therapy, maintaining a high bladder filling remains important. However, the recommendation for rectum filling can be abandoned, as reproducibility is not critical for adaptive radiotherapy and no dosimetric advantage per se is associated with an empty rectum. Patients may even be encouraged not to void their bowels shortly before treatment, as long as this is tolerated over the treatment session. - Open Access
- 10 August 2023
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 131 (6) , 061901
Evidence for Modification of Quark Hadronization in High-Multiplicity Collisions atThe production rate of mesons relative to mesons is measured by the LHCb experiment in collisions at a center-of-mass energy over the forward rapidity interval as a function of the charged particle multiplicity measured in the event. Evidence at the level is found for an increase of the ratio of to cross sections with multiplicity at transverse momenta below , with no significant multiplicity dependence at higher transverse momentum. Comparison with data from collisions implies that the density of the hadronic medium may affect the production rates of mesons. This is qualitatively consistent with the emergence of quark coalescence as an additional hadronization mechanism in high-multiplicity collisions.- 10 August 2023
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 131 (6) , 061901
Open AccessEvidence for Modification of Quark Hadronization in High-Multiplicity Collisions atThe production rate of mesons relative to mesons is measured by the LHCb experiment in collisions at a center-of-mass energy over the forward rapidity interval as a function of the charged particle multiplicity measured in the event. Evidence at the level is found for an increase of the ratio of to cross sections with multiplicity at transverse momenta below , with no significant multiplicity dependence at higher transverse momentum. Comparison with data from collisions implies that the density of the hadronic medium may affect the production rates of mesons. This is qualitatively consistent with the emergence of quark coalescence as an additional hadronization mechanism in high-multiplicity collisions. - Open Access
- 8 August 2023
- Published by American Physical Society (APS) in Physical Review D
- Vol. 108 (3) , 032007
Search for violation using -odd correlations in decaysA search for and violation in charmless four-body decays is performed using triple-product asymmetry observables. It is based on proton-proton collision data collected by the LHCb experiment at center-of-mass energies of 7, 8 and 13 TeV, corresponding to a total integrated luminosity of . The - and -violating asymmetries are measured both in the integrated phase space and in specific regions. No evidence is seen for violation. -parity violation is observed at a significance of 5.8 standard deviations.- 8 August 2023
- Published by American Physical Society (APS) in Physical Review D
- Vol. 108 (3) , 032007
Open AccessSearch for violation using -odd correlations in decaysA search for and violation in charmless four-body decays is performed using triple-product asymmetry observables. It is based on proton-proton collision data collected by the LHCb experiment at center-of-mass energies of 7, 8 and 13 TeV, corresponding to a total integrated luminosity of . The - and -violating asymmetries are measured both in the integrated phase space and in specific regions. No evidence is seen for violation. -parity violation is observed at a significance of 5.8 standard deviations. - Open Access
- 4 August 2023
- Published by American Physical Society (APS) in Physical Review D
- Vol. 108 (3) , L031103
Multidifferential study of identified charged hadron distributions in -tagged jets in proton-proton collisions atJet fragmentation functions are measured for the first time in proton-proton collisions for charged pions, kaons, and protons within jets recoiling against a boson. The charged-hadron distributions are studied longitudinally and transversely to the jet direction for jets with transverse momentum and in the pseudorapidity range . The data sample was collected with the LHCb experiment at a center-of-mass energy of 13 TeV, corresponding to an integrated luminosity of . Triple differential distributions as a function of the hadron longitudinal momentum fraction, hadron transverse momentum, and jet transverse momentum are also measured for the first time. This helps constrain transverse-momentum-dependent fragmentation functions. Differences in the shapes and magnitudes of the measured distributions for the different hadron species provide insights into the hadronization process for jets predominantly initiated by light quarks.- 4 August 2023
- Published by American Physical Society (APS) in Physical Review D
- Vol. 108 (3) , L031103
Open AccessMultidifferential study of identified charged hadron distributions in -tagged jets in proton-proton collisions atJet fragmentation functions are measured for the first time in proton-proton collisions for charged pions, kaons, and protons within jets recoiling against a boson. The charged-hadron distributions are studied longitudinally and transversely to the jet direction for jets with transverse momentum and in the pseudorapidity range . The data sample was collected with the LHCb experiment at a center-of-mass energy of 13 TeV, corresponding to an integrated luminosity of . Triple differential distributions as a function of the hadron longitudinal momentum fraction, hadron transverse momentum, and jet transverse momentum are also measured for the first time. This helps constrain transverse-momentum-dependent fragmentation functions. Differences in the shapes and magnitudes of the measured distributions for the different hadron species provide insights into the hadronization process for jets predominantly initiated by light quarks. - Open Access
- 28 July 2023
- Published by American Physical Society (APS) in Physical Review D
- Vol. 108 (1) , 012023
Amplitude analysis of the decay and baryon polarization measurement in semileptonic beauty hadron decaysAn amplitude analysis of decays together with a measurement of the polarization vector in semiōleptonic beauty hadron decays is presented. A sample of 400 000 candidates is selected from proton-proton collisions recorded by the LHCb detector at a center-of-mass energy of 13 TeV. An amplitude model is developed and the resonance fractions as well as two- and three-body decay parameters are reported. The mass and width of the state are also determined. A significant polarization is found. A large sensitivity of the decay to the polarization is seen, making the amplitude model suitable for polarization measurements in other systems.- 28 July 2023
- Published by American Physical Society (APS) in Physical Review D
- Vol. 108 (1) , 012023
Open AccessAmplitude analysis of the decay and baryon polarization measurement in semileptonic beauty hadron decaysAn amplitude analysis of decays together with a measurement of the polarization vector in semiōleptonic beauty hadron decays is presented. A sample of 400 000 candidates is selected from proton-proton collisions recorded by the LHCb detector at a center-of-mass energy of 13 TeV. An amplitude model is developed and the resonance fractions as well as two- and three-body decay parameters are reported. The mass and width of the state are also determined. A significant polarization is found. A large sensitivity of the decay to the polarization is seen, making the amplitude model suitable for polarization measurements in other systems.