KPKaiden B. Porter

Kaiden B. Porter

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kaiden B. Porter has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative Analysis of Corneal Higher-Order Aberrations after Laser-Assisted In Situ Keratomileusis, Photorefractive Keratectomy, and Small Incision Lenticule Extraction with Correlations to Change in Myopic Q-Value and Spherical Equivalent with and without Astigmatism

    by Majid Moshirfar, Soroush Omidvarnia, Michael T. Christensen, Kaiden B. Porter, Josh S. Theis, Nathan M. Olson, Isabella M. Stoakes, Carter J. Payne, Phillip C. Hoopes

    Background: This retrospective chart review compared the higher-order aberrations (HOAs) among photorefractive keratectomy (PRK), laser-assisted in situ keratomileusis (LASIK), and small incision lenticule extraction (SMILE) alongside changes in spherical equivalent (SEQ) and corneal shape (Q-value). Methods: Analyzing 371 myopic eyes, including 154 LASIK, 173 PRK, and 44 SMILE cases, Pentacam imaging was utilized pre-operatively and at one-year post-operative visits. Results: All procedures resulted in 100% of patients achieving an uncorrected distance visual acuity (UDVA) of 20/40 or better, with 87% of LASIK and PRK, and 91% of SMILE patients having 20/20 or better. Significant increases in HOAs were observed across all procedures (p < 0.05), correlating positively with SEQ and Q-value changes (LASIK (0.686, p < 0.05), followed by PRK (0.4503, p < 0.05), and SMILE (0.386, p < 0.05)). Vertical coma and spherical aberration (SA) were the primary factors for heightened aberration magnitude among the procedures (p < 0.05), with the largest contribution in SMILE, which is likely attributed to the centration at the corneal apex. Notably, PRK showed insignificant changes in vertical coma (−0.197 µm ± 0.0168 to −0.192 µm ± 0.0198, p = 0.78), with an increase in oblique trefoil (p < 0.05). Conclusions: These findings underscore differences in HOAs among PRK, LASIK, and SMILE, helping to guide clinicians.


  • Open Access

    Assessing Visual Outcomes: A Comparative Study of US-FDA Premarket Approval Data for Multifocal and EDOF Lens Implants in Cataract Surgery

    by Majid Moshirfar, Isabella M. Stoakes, Joshua S. Theis, Kaiden B. Porter, Jordan M. Santos, Tanisha Martheswaran, Carter J. Payne, Phillip C. Hoopes

    This study compares the efficacy, safety, and patient-reported outcomes of three intraocular implants (IOL): Tecnis Synergy IOL, AcrySof IQ PanOptix Trifocal, and Tecnis Symfony EDOF IOL. Participants achieving 20/20 or better uncorrected binocular visual acuity were as follows: Synergy—67% distance, 64% intermediate, and 47% near; PanOptix—73% distance, 73% intermediate, and 50% near; and Symfony—63% distance, 75% intermediate, and 22% near. Symfony demonstrated superior intermediate visual acuity compared to Synergy (p = 0.0182) for those achieving 20/25 or better. Both Synergy and PanOptix showed superiority over Symfony for near visual acuity (p < 0.0001). Halos were statistically more common in Synergy participants compared to PanOptix (p = 0.0013) and Symfony (p < 0.0001). Each trial lens outperformed its monofocal IOL in terms of independence from glasses or contacts, with Synergy and PanOptix showing statistical significance over Symfony. Comparing contrast sensitivities and defocus curves was challenging due to data variance and as such, standardization of United States Food and Drug Administration (US-FDA) data reporting is key for better comparison of outcomes among different IOL platforms.