Larry Bartoszek
Research Subjects
Larry Bartoszek has a total of 261 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Zhukovsky
MIT Plasma Science and Fusion Center, Cambridge, MA, USA
4 shared publications - Amy Watterson
Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA, USA
4 shared publications - Philip C. Michael
Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA, USA
4 shared publications - Raheem Barnett
Commonwealth Fusion Systems LLC, Devens, MA, USA
4 shared publications - Rui Vieira
Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA, USA
4 shared publications - Theodore Golfinopoulos
Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA, United States of America
4 shared publications
Latest Publications
- Open Access
- 17 March 2026
- Published by Elsevier in Nuclear Physics B
- Vol. 1026
The forward physics facility: Physics opportunities and conceptual design
- 17 March 2026
- Published by Elsevier in Nuclear Physics B
- Vol. 1026
Open AccessThe forward physics facility: Physics opportunities and conceptual design
- Open Access
- 22 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (2) , 1-15
Design, Fabrication, and Assembly of the SPARC Toroidal Field Model Coil
The SPARC Toroidal Field Model Coil (TFMC) is the first large-scale (∼3 m), high-field (∼20 T) superconducting fusion magnet based on Rare Earth Yttrium Barium Copper Oxide (REBCO). Weighing 10,058 kg and utilizing 270 km of REBCO, the TFMC is a non-insulated, stack-in-plate style superconducting magnet. It has three main components: (1) the winding pack; (2) the structural case; and (3) the case extensions, or plena. The winding pack is composed of sixteen single pancakes with two termination plates top and bottom. The pancakes are Nitronic 40 radial plates machined with spiral channels on one side for the REBCO tape stack and single-pass channels on the opposite side for supercritical helium coolant. After assembly, each pancake undergoes a vacuum-pressure impregnation solder process to provide good mechanical protection of the REBCO tape stack and efficient thermal and electrical connectivity within each pancake. The pancakes are bolted along the inner and outer perimeter to provide mechanical and thermal connectivity while inter-pancake joints provide low resistance current transfer between pancakes. The top and bottom termination plates facilitate electrical connection to a superconducting feeder system. Embedded throughout the winding pack are 211 voltage taps, 34 temperature sensors, 34 helium flow monitors, 4 Hall probes, and 4 resistive surface heaters. The winding pack is contained within a structural case, a “trough and lid” style design composed of two Nitronic 50 forgings machined to shape and bolted together. The case reacts the large electromechanical stresses approaching 1 GPa during operation and serves as a pressure vessel that enables 20 bar supercritical helium flow that cools the winding pack and case. Two case extensions are attached to the case with unique high-pressure feedthroughs to provide winding pack access for current, cooling, and instrumentation, completing the magnet assembly.
- 22 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (2) , 1-15
Open AccessDesign, Fabrication, and Assembly of the SPARC Toroidal Field Model Coil
The SPARC Toroidal Field Model Coil (TFMC) is the first large-scale (∼3 m), high-field (∼20 T) superconducting fusion magnet based on Rare Earth Yttrium Barium Copper Oxide (REBCO). Weighing 10,058 kg and utilizing 270 km of REBCO, the TFMC is a non-insulated, stack-in-plate style superconducting magnet. It has three main components: (1) the winding pack; (2) the structural case; and (3) the case extensions, or plena. The winding pack is composed of sixteen single pancakes with two termination plates top and bottom. The pancakes are Nitronic 40 radial plates machined with spiral channels on one side for the REBCO tape stack and single-pass channels on the opposite side for supercritical helium coolant. After assembly, each pancake undergoes a vacuum-pressure impregnation solder process to provide good mechanical protection of the REBCO tape stack and efficient thermal and electrical connectivity within each pancake. The pancakes are bolted along the inner and outer perimeter to provide mechanical and thermal connectivity while inter-pancake joints provide low resistance current transfer between pancakes. The top and bottom termination plates facilitate electrical connection to a superconducting feeder system. Embedded throughout the winding pack are 211 voltage taps, 34 temperature sensors, 34 helium flow monitors, 4 Hall probes, and 4 resistive surface heaters. The winding pack is contained within a structural case, a “trough and lid” style design composed of two Nitronic 50 forgings machined to shape and bolted together. The case reacts the large electromechanical stresses approaching 1 GPa during operation and serves as a pressure vessel that enables 20 bar supercritical helium flow that cools the winding pack and case. Two case extensions are attached to the case with unique high-pressure feedthroughs to provide winding pack access for current, cooling, and instrumentation, completing the magnet assembly.
- Open Access
- 10 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (2) , 1-16
Building the Runway: A New Superconducting Magnet Test Facility Made for the SPARC Toroidal Field Model Coil
A new superconducting magnet test facility was created at the MIT Plasma Science and Fusion Center (PSFC) for the SPARC Toroidal Field Model Coil (TFMC) program. The facility was designed and constructed in parallel with the TFMC between 2019 and 2021, with capabilities and design approaches tailored to the needs of this project and its time line. The major components of the facility include a new cryostat (outer dimensions, 5.3 m × 3.7 m × 1.5 m) with open bore; a novel cooling system circulating supercritical helium in a closed loop to provide $\sim$ 600 W cooling power at $\sim$ 20 bar-a, $\sim$ 20 K; a 50-kA $\pm$ 10-V power supply with supporting nitrogen-cooled high temperature superconductor (HTS) binary current leads operating at record currents, as well as VIPER-cable HTS cold bus; and a new instrumentation and programmable-logic-controller-based control system handling $\sim$ 650 input and output signals distributed between the facility and the test article. Substantial legacy infrastructure inherited from the PSFC's Alcator C-Mod tokamak program, including liquid nitrogen facilities and 10 mW of ac power, was instrumental in the rapid deployment of these new systems. Immediately after initial commissioning, the facility was used successfully to test the SPARC TFMC, operating the magnet in a campaign achieving 20 T on the coil, as well as a second campaign performing quench testing. The facility has since undergone several upgrades and has been used in campaigns of other test articles, and it is expected that the facility will remain a resource for the community for the foreseeable future to develop fusion magnets and related technology.
- 10 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (2) , 1-16
Open AccessBuilding the Runway: A New Superconducting Magnet Test Facility Made for the SPARC Toroidal Field Model Coil
A new superconducting magnet test facility was created at the MIT Plasma Science and Fusion Center (PSFC) for the SPARC Toroidal Field Model Coil (TFMC) program. The facility was designed and constructed in parallel with the TFMC between 2019 and 2021, with capabilities and design approaches tailored to the needs of this project and its time line. The major components of the facility include a new cryostat (outer dimensions, 5.3 m × 3.7 m × 1.5 m) with open bore; a novel cooling system circulating supercritical helium in a closed loop to provide $\sim$ 600 W cooling power at $\sim$ 20 bar-a, $\sim$ 20 K; a 50-kA $\pm$ 10-V power supply with supporting nitrogen-cooled high temperature superconductor (HTS) binary current leads operating at record currents, as well as VIPER-cable HTS cold bus; and a new instrumentation and programmable-logic-controller-based control system handling $\sim$ 650 input and output signals distributed between the facility and the test article. Substantial legacy infrastructure inherited from the PSFC's Alcator C-Mod tokamak program, including liquid nitrogen facilities and 10 mW of ac power, was instrumental in the rapid deployment of these new systems. Immediately after initial commissioning, the facility was used successfully to test the SPARC TFMC, operating the magnet in a campaign achieving 20 T on the coil, as well as a second campaign performing quench testing. The facility has since undergone several upgrades and has been used in campaigns of other test articles, and it is expected that the facility will remain a resource for the community for the foreseeable future to develop fusion magnets and related technology.
- Open Access
- 13 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (2) , 1-13
A 20-K, 600-W, Cryocooler-Based, Supercritical Helium Circulation System for the SPARC Toroidal Field Model Coil Program
From June 2019 to July 2021, the MIT Plasma Science and Fusion Center, in collaboration with Commonwealth Fusions Systems, designed, built, and commissioned a test facility at the Massachusetts Institute of Technology to evaluate the performance of a rare-earth-yttrium-barium-copper-oxide-based, 2.9-m tall, 1.9-m wide Toroidal Field Model Coil (TFMC) for the SPARC tokamak. This article presents the facility's supercritical helium (SHe) circulation system design and measured performance. The facility employed a forced-flow SHe circulation loop cooled by cryocoolers to provide a nominal cooling power of 600 W at 20 K and up to 70 g/s SHe flow to the TFMC at an absolute pressure of 20 bar. The reliance on cryocoolers as the facility's cooling source was an ideal arrangement. Procurement costs were modest, acquisition time was reasonable, and seating requirements were minimal. A steady improvement in cryocooler design provided a simple-to-use system with sufficient cooling capacity for our needs. Extensive, closed-loop analyses were performed both to support this procurement and to finalize the overall design of the SHe cooling circuit. The SHe system worked reliably, permitting flexible operation of the TFMC test facility under all working conditions.
- 13 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (2) , 1-13
Open AccessA 20-K, 600-W, Cryocooler-Based, Supercritical Helium Circulation System for the SPARC Toroidal Field Model Coil Program
From June 2019 to July 2021, the MIT Plasma Science and Fusion Center, in collaboration with Commonwealth Fusions Systems, designed, built, and commissioned a test facility at the Massachusetts Institute of Technology to evaluate the performance of a rare-earth-yttrium-barium-copper-oxide-based, 2.9-m tall, 1.9-m wide Toroidal Field Model Coil (TFMC) for the SPARC tokamak. This article presents the facility's supercritical helium (SHe) circulation system design and measured performance. The facility employed a forced-flow SHe circulation loop cooled by cryocoolers to provide a nominal cooling power of 600 W at 20 K and up to 70 g/s SHe flow to the TFMC at an absolute pressure of 20 bar. The reliance on cryocoolers as the facility's cooling source was an ideal arrangement. Procurement costs were modest, acquisition time was reasonable, and seating requirements were minimal. A steady improvement in cryocooler design provided a simple-to-use system with sufficient cooling capacity for our needs. Extensive, closed-loop analyses were performed both to support this procurement and to finalize the overall design of the SHe cooling circuit. The SHe system worked reliably, permitting flexible operation of the TFMC test facility under all working conditions.
- Top Cited PapersOpen Access
- 13 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (2) , 1-16
The SPARC Toroidal Field Model Coil Program
The SPARC Toroidal Field Model Coil (TFMC) Program was a three-year effort between 2018 and 2021 that developed novel rare earth barium copper oxide (REBCO) superconductor technologies and then successfully utilized these technologies to design, build, and test a first-in-class, high-field (∼20 T), representative-scale (∼3 m) superconducting toroidal field (TF) coil. The program was executed jointly by the MIT Plasma Science and Fusion Center (PSFC) and Commonwealth Fusion Systems (CFS) as a technology enabler of the superconducting high-field pathway to fusion energy, and, in particular, as a risk retirement program for the no insulation (NI) TF magnet in the SPARC net-energy fusion tokamak. The TFMC achieved its programmatic goal of experimentally demonstrating a large-scale high-field REBCO magnet, achieving 20.1 T peak field-on-conductor with 40.5 kA of terminal current, 815 kN/m of Lorentz loading on the REBCO stacks, and almost 1 GPa of mechanical stress accommodated by the structural case. Fifteen internal demountable pancake-to-pancake joints operated in the 0.5 to 2.0 nΩ range at 20 K and in magnetic fields up to 12 T. The dc and ac electromagnetic performance of the magnet predicted by new advances in high-fidelity computational models was confirmed in two test campaigns while the parallel, single-pass, pressure-vessel style coolant scheme capable of large heat removal was validated. In the test facility, a feeder system composed of REBCO current leads and cables was experimentally qualified up to 50 kA, and a liquid-free cryocooler-based helium cryogenic system provided 600 W of cooling power at 20 K with mass flow rates up to 70 g/s at a maximum design pressure of 2 MPa for the test campaigns. Finally, the feasibility of using passive, self-protection against a quench in a fusion-scale NI TF coil was experimentally assessed. While the TFMC was intentionally not optimized for quench resiliency—and suffered localized thermal damage in response to an intentional open-circuit quench at 31.5 kA terminal current—the extensive data and validated models that it produced represent a critical step towards this important objective.
- 13 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (2) , 1-16
Top Cited PapersOpen AccessThe SPARC Toroidal Field Model Coil Program
The SPARC Toroidal Field Model Coil (TFMC) Program was a three-year effort between 2018 and 2021 that developed novel rare earth barium copper oxide (REBCO) superconductor technologies and then successfully utilized these technologies to design, build, and test a first-in-class, high-field (∼20 T), representative-scale (∼3 m) superconducting toroidal field (TF) coil. The program was executed jointly by the MIT Plasma Science and Fusion Center (PSFC) and Commonwealth Fusion Systems (CFS) as a technology enabler of the superconducting high-field pathway to fusion energy, and, in particular, as a risk retirement program for the no insulation (NI) TF magnet in the SPARC net-energy fusion tokamak. The TFMC achieved its programmatic goal of experimentally demonstrating a large-scale high-field REBCO magnet, achieving 20.1 T peak field-on-conductor with 40.5 kA of terminal current, 815 kN/m of Lorentz loading on the REBCO stacks, and almost 1 GPa of mechanical stress accommodated by the structural case. Fifteen internal demountable pancake-to-pancake joints operated in the 0.5 to 2.0 nΩ range at 20 K and in magnetic fields up to 12 T. The dc and ac electromagnetic performance of the magnet predicted by new advances in high-fidelity computational models was confirmed in two test campaigns while the parallel, single-pass, pressure-vessel style coolant scheme capable of large heat removal was validated. In the test facility, a feeder system composed of REBCO current leads and cables was experimentally qualified up to 50 kA, and a liquid-free cryocooler-based helium cryogenic system provided 600 W of cooling power at 20 K with mass flow rates up to 70 g/s at a maximum design pressure of 2 MPa for the test campaigns. Finally, the feasibility of using passive, self-protection against a quench in a fusion-scale NI TF coil was experimentally assessed. While the TFMC was intentionally not optimized for quench resiliency—and suffered localized thermal damage in response to an intentional open-circuit quench at 31.5 kA terminal current—the extensive data and validated models that it produced represent a critical step towards this important objective.
- Open Access
- 28 June 2023
- Published by Elsevier in Acta Astronautica
- Vol. 211, 631-649
Conditions at the interface between the space elevator tether and its climber
- 28 June 2023
- Published by Elsevier in Acta Astronautica
- Vol. 211, 631-649
Open AccessConditions at the interface between the space elevator tether and its climber