Dan Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dan Yu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Jiyang Wang
Institute of Advanced Engineering Structures, Zhejiang University, Hangzhou 310058, China
2 shared publications - Xiaohua Ji
College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310058, China
2 shared publications - Chen Zeng
College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310058, China
1 shared publication - Fujiang Mu
College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310058, China
1 shared publication - Lingpeng Ye
The Architectural Design & Research Institute of Zhejiang University Co., Ltd., Hangzhou 310007, China
1 shared publication - Pinghuai Zhou
Zhejiang Province Institute of Architectural Design and Research, Hangzhou 310006, China
1 shared publication
Latest Publications
- Open Access
Effect of Textile Layers and Hydroxypropyl Methylcellulose on Flexural Behavior of TRLC Thin Plates
To examine the flexural toughness characteristics of textile-reinforced lightweight aggregate concrete (TRLC), a four-point bending test was conducted to assess the impact of varying numbers of textile layers and the inclusion of hydroxypropyl methylcellulose on the ultimate load-bearing capacity and deformation capacity of TRLC thin plates. Six groups of specimens were prepared for the experiment, and the bending capacity of the thin plates in each group was evaluated. The flexural toughness index was utilized to quantify the bending performance of TRLC thin plates. The findings revealed that increasing the number of textile layers improved the initial cracking load, initial cracking deflection, ultimate load, ductility, and flexural toughness of the thin plates. For the specimens without HPMC, the initial cracking load was increased by up to 36.1%, the ultimate load by up to 40.9%, and the flexural toughness index by up to 292% as the number of textile layers was increased. For specimens doped with HPMC, the initial cracking load was increased by up to 61.7%, the ultimate load by up to 246.7%, and the flexural toughness index by up to 65%. The TRLC thin plate containing hydroxypropyl methylcellulose exhibited a reduced initial cracking load yet displayed a stronger matrix consistency and good flexural toughness. Moreover, the enhancement in the ultimate load of TRLC thin plates with hydroxypropyl methylcellulose was more pronounced with an increased number of textile layers, resulting in a significantly higher number of cracks compared to TRLC without hydroxypropyl methylcellulose and an 11.40-fold increase in the flexural toughness index.
Open AccessEffect of Textile Layers and Hydroxypropyl Methylcellulose on Flexural Behavior of TRLC Thin Plates
To examine the flexural toughness characteristics of textile-reinforced lightweight aggregate concrete (TRLC), a four-point bending test was conducted to assess the impact of varying numbers of textile layers and the inclusion of hydroxypropyl methylcellulose on the ultimate load-bearing capacity and deformation capacity of TRLC thin plates. Six groups of specimens were prepared for the experiment, and the bending capacity of the thin plates in each group was evaluated. The flexural toughness index was utilized to quantify the bending performance of TRLC thin plates. The findings revealed that increasing the number of textile layers improved the initial cracking load, initial cracking deflection, ultimate load, ductility, and flexural toughness of the thin plates. For the specimens without HPMC, the initial cracking load was increased by up to 36.1%, the ultimate load by up to 40.9%, and the flexural toughness index by up to 292% as the number of textile layers was increased. For specimens doped with HPMC, the initial cracking load was increased by up to 61.7%, the ultimate load by up to 246.7%, and the flexural toughness index by up to 65%. The TRLC thin plate containing hydroxypropyl methylcellulose exhibited a reduced initial cracking load yet displayed a stronger matrix consistency and good flexural toughness. Moreover, the enhancement in the ultimate load of TRLC thin plates with hydroxypropyl methylcellulose was more pronounced with an increased number of textile layers, resulting in a significantly higher number of cracks compared to TRLC without hydroxypropyl methylcellulose and an 11.40-fold increase in the flexural toughness index.
- Open Access
Toughening Mechanism of Directional Fabric Woven Net and/or Non-Directional Short-Cut Fiber-Reinforced Sprayed Cement Mortar Thin-Plates
In this paper, a non-directional short-cut polyvinyl alcohol fiber (PVA), directional carbon-glass fabric woven net, and a combination of these fibers were used to reinforce sprayed cement mortar (named FRCM-SP, FRCM-CN, and FRCM-PN accordingly), and the direct tensile and four-point bending tests of these three types of thin plates were conducted. It was shown that the direct tensile strength of FRCM-PN reached 7.22 MPa under the same cement mortar matrix, which was 175.6% and 198.3% higher than that of FRCM-SP and FRCM-CN, respectively; the ultimate tensile strain of FRCM-PN was 3.34%, which was 65.3% and 1291.7% higher than that of FRCM-SP and FRCM-CN, respectively. Similarly, the ultimate flexural strength of FRCM-PN reached 33.67 MPa, which was 182.5% and 519.6% higher than that of FRCM-SP and FRCM-CN, respectively. In addition, the tensile, bending toughness index, and residual strength factor of FRCM-PN were much higher than those of FRCM-SP and FRCM-CN, indicating that the incorporation of non-directional short-cut PVA fibers improved the interfacial bonding properties between the cement mortar matrix and the fiber yarn and significantly enhanced the toughness and energy dissipation capacity of the sprayed cement mortar. Therefore, the use of a certain amount of non-directional short-cut PVA fibers can improve the interfacial bonding properties between the cement mortar and the fabric woven net while ensuring the spraying performance and significantly improving the reinforcing and toughening effect on the cement mortar to meet the demand for large-area rapid construction and structural seismic reinforcement.
Open AccessToughening Mechanism of Directional Fabric Woven Net and/or Non-Directional Short-Cut Fiber-Reinforced Sprayed Cement Mortar Thin-Plates
In this paper, a non-directional short-cut polyvinyl alcohol fiber (PVA), directional carbon-glass fabric woven net, and a combination of these fibers were used to reinforce sprayed cement mortar (named FRCM-SP, FRCM-CN, and FRCM-PN accordingly), and the direct tensile and four-point bending tests of these three types of thin plates were conducted. It was shown that the direct tensile strength of FRCM-PN reached 7.22 MPa under the same cement mortar matrix, which was 175.6% and 198.3% higher than that of FRCM-SP and FRCM-CN, respectively; the ultimate tensile strain of FRCM-PN was 3.34%, which was 65.3% and 1291.7% higher than that of FRCM-SP and FRCM-CN, respectively. Similarly, the ultimate flexural strength of FRCM-PN reached 33.67 MPa, which was 182.5% and 519.6% higher than that of FRCM-SP and FRCM-CN, respectively. In addition, the tensile, bending toughness index, and residual strength factor of FRCM-PN were much higher than those of FRCM-SP and FRCM-CN, indicating that the incorporation of non-directional short-cut PVA fibers improved the interfacial bonding properties between the cement mortar matrix and the fiber yarn and significantly enhanced the toughness and energy dissipation capacity of the sprayed cement mortar. Therefore, the use of a certain amount of non-directional short-cut PVA fibers can improve the interfacial bonding properties between the cement mortar and the fabric woven net while ensuring the spraying performance and significantly improving the reinforcing and toughening effect on the cement mortar to meet the demand for large-area rapid construction and structural seismic reinforcement.