Alexa Mma Simon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alexa Mma Simon has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Amy Tyberg
Hackensack Univ Med Ctr, Dept Med, Div Adv & Therapeut Endoscopy, Hackensack, NJ USA
2 shared publications - Michel Kahaleh
Advanced and Therapeutic Endoscopy Hackensack University Medical Center Hackensack New Jersey USA
2 shared publications - Monica Gaidhane
Gastroenterology, Robert Wood Johnson University Hospital, New Brunswick, NJ
2 shared publications - Amol Bapaye
Shivanand Desai Center for Digestive Disorders, Deenanath Mangeshkar Hospital and Research Center, Pune, Maharashtra, India
1 shared publication - Anand Kumar
Division of Gastroenterology, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania, USA
1 shared publication - Ashish Gandhi
Pune Hospital, Pune Hospital, Pune, India
1 shared publication
Latest Publications
- Open Access
- 4 May 2023
- Published by Wolters Kluwer Health in Clinical and Translational Gastroenterology
- Vol. 14 (6) , e00593
Endoscopic Ultrasound-Guided Gallbladder Drainage Versus Percutaneous Drainage in Patients With Acute Cholecystitis Undergoing Elective Cholecystectomy
INTRODUCTION: Cholecystectomy (CCY) is the gold standard treatment of acute cholecystitis (AC). Nonsurgical management of AC includes percutaneous transhepatic gallbladder drainage (PT-GBD) and endoscopic ultrasound-guided gallbladder drainage (EUS-GBD). This study aims to compare outcomes of patients who undergo CCY after having received EUS-GBD vs PT-GBD. METHODS: A multicenter international study was conducted in patients with AC who underwent EUS-GBD or PT-GBD, followed by an attempted CCY, between January 2018 and October 2021. Demographics, clinical characteristics, procedural details, postprocedure outcomes, and surgical details and outcomes were compared. RESULTS: One hundred thirty-nine patients were included: EUS-GBD in 46 patients (27% male, mean age 74 years) and PT-GBD in 93 patients (50% male, mean age 72 years). Surgical technical success was not significantly different between the 2 groups. In the EUS-GBD group, there was decreased operative time (84.2 vs 165.4 minutes, P < 0.00001), time to symptom resolution (4.2 vs 6.3 days, P = 0.005), and length of stay (5.4 vs 12.3 days, P = 0.001) compared with the PT-GBD group. There was no difference in the rate of conversion from laparoscopic to open CCY: 5 of 46 (11%) in the EUS-GBD arm and 18 of 93 (19%) in the PT-GBD group (P value 0.2324). DISCUSSION: Patients who received EUS-GBD had a significantly shorter interval between gallbladder drainage and CCY, shorter surgical procedure times, and shorter length of stay for the CCY compared with those who received PT-GBD. EUS-GBD should be considered an acceptable modality for gallbladder drainage and should not preclude patients from eventual CCY.
- 4 May 2023
- Published by Wolters Kluwer Health in Clinical and Translational Gastroenterology
- Vol. 14 (6) , e00593
Open AccessEndoscopic Ultrasound-Guided Gallbladder Drainage Versus Percutaneous Drainage in Patients With Acute Cholecystitis Undergoing Elective Cholecystectomy
INTRODUCTION: Cholecystectomy (CCY) is the gold standard treatment of acute cholecystitis (AC). Nonsurgical management of AC includes percutaneous transhepatic gallbladder drainage (PT-GBD) and endoscopic ultrasound-guided gallbladder drainage (EUS-GBD). This study aims to compare outcomes of patients who undergo CCY after having received EUS-GBD vs PT-GBD. METHODS: A multicenter international study was conducted in patients with AC who underwent EUS-GBD or PT-GBD, followed by an attempted CCY, between January 2018 and October 2021. Demographics, clinical characteristics, procedural details, postprocedure outcomes, and surgical details and outcomes were compared. RESULTS: One hundred thirty-nine patients were included: EUS-GBD in 46 patients (27% male, mean age 74 years) and PT-GBD in 93 patients (50% male, mean age 72 years). Surgical technical success was not significantly different between the 2 groups. In the EUS-GBD group, there was decreased operative time (84.2 vs 165.4 minutes, P < 0.00001), time to symptom resolution (4.2 vs 6.3 days, P = 0.005), and length of stay (5.4 vs 12.3 days, P = 0.001) compared with the PT-GBD group. There was no difference in the rate of conversion from laparoscopic to open CCY: 5 of 46 (11%) in the EUS-GBD arm and 18 of 93 (19%) in the PT-GBD group (P value 0.2324). DISCUSSION: Patients who received EUS-GBD had a significantly shorter interval between gallbladder drainage and CCY, shorter surgical procedure times, and shorter length of stay for the CCY compared with those who received PT-GBD. EUS-GBD should be considered an acceptable modality for gallbladder drainage and should not preclude patients from eventual CCY.
- 24 August 2022
- Published by Wolters Kluwer Health in Journal of Clinical Gastroenterology
- Vol. 57 (8) , 798-803
Comparing the Safety and Efficacy of Two Commercially Available Single-Use Duodenoscopes
Introduction: Single-use disposable duodenoscopes (SDD) have been developed to mitigate infectious risks related to reusable duodenoscopes. The aim of this study is to compare the safety and efficacy of the two available SDDs in the United States. Methods: We conducted a comparative study of 2 SDD in consecutive ERCP procedures performed by expert endoscopists from 9 academic centers. Performance ratings, procedure details, and adverse events were collected. Results: A total of 201 patients were included: 129 patients underwent ERCP with Exalt (mean age 63, Males- 66 (51%), 72 with aScope Duodeno (mean age 65, males=30 (42%). A majority of endoscopists had performed >2000 ERCPs in both groups (71% Exalt, 93% aScope Duodeno). Technical success was 92% in both groups (n=119 Exalt-group, n=66 aScope-Duodeno-group). The procedural complexity for the ERCP cases performed were: Grade 1: 35 cases (18%), Grade 2: 83 cases (41%), Grade 3: 65 cases (32%), and Grade 4: 18 cases (9%). Thirteen patients (10%) from the Exalt group and 16 patients (22%) from the aScope Duodeno group required conversion to a reusable duodenoscope. On a scale of 1 to 5, Exalt and aScope Duodeno, respectively, were rated: 2.31 versus 2.60 for location and visualization quality, 1.38 versus 1.57 for maneuverability based on papillary orientation, 1.48 versus 1.15 for suction/air control, and 2.31 versus 2.34 for elevator efficiency. None of the adverse events were related to the SDDs. Conclusions: The 2 SDDs were comparable. Further ongoing enhancements to these devices will improve maneuverability and clinical effectiveness.
- 24 August 2022
- Published by Wolters Kluwer Health in Journal of Clinical Gastroenterology
- Vol. 57 (8) , 798-803
Comparing the Safety and Efficacy of Two Commercially Available Single-Use Duodenoscopes
Introduction: Single-use disposable duodenoscopes (SDD) have been developed to mitigate infectious risks related to reusable duodenoscopes. The aim of this study is to compare the safety and efficacy of the two available SDDs in the United States. Methods: We conducted a comparative study of 2 SDD in consecutive ERCP procedures performed by expert endoscopists from 9 academic centers. Performance ratings, procedure details, and adverse events were collected. Results: A total of 201 patients were included: 129 patients underwent ERCP with Exalt (mean age 63, Males- 66 (51%), 72 with aScope Duodeno (mean age 65, males=30 (42%). A majority of endoscopists had performed >2000 ERCPs in both groups (71% Exalt, 93% aScope Duodeno). Technical success was 92% in both groups (n=119 Exalt-group, n=66 aScope-Duodeno-group). The procedural complexity for the ERCP cases performed were: Grade 1: 35 cases (18%), Grade 2: 83 cases (41%), Grade 3: 65 cases (32%), and Grade 4: 18 cases (9%). Thirteen patients (10%) from the Exalt group and 16 patients (22%) from the aScope Duodeno group required conversion to a reusable duodenoscope. On a scale of 1 to 5, Exalt and aScope Duodeno, respectively, were rated: 2.31 versus 2.60 for location and visualization quality, 1.38 versus 1.57 for maneuverability based on papillary orientation, 1.48 versus 1.15 for suction/air control, and 2.31 versus 2.34 for elevator efficiency. None of the adverse events were related to the SDDs. Conclusions: The 2 SDDs were comparable. Further ongoing enhancements to these devices will improve maneuverability and clinical effectiveness.