Fitsum Tariku
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fitsum Tariku has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Barilelo Nghana
Department of Civil and Environmental Engineering, Faculty of Engineering, Western University (UWO), London, ON N6A 3K7, Canada
3 shared publications - Girma Bitsuamlak
Western University
2 shared publications Kumar Kumaran
Institute for Research in Construction
2 shared publicationsPaul Fazio
Concordia University
2 shared publicationsSudhakar Molleti
2 shared publications- Addisu Alamirew Meku
Bahir Dar Institute of Technology, Bahir Dar University
1 shared publication
Latest Publications
- Open Access
Recent Advances in Integrated Building Cavities: A Comprehensive Review of Fundamentals, Modeling, and Performance Evaluation
Currently, building envelopes are evolving from simple passive shields to smart systems. They control the exchange of energy, air, and moisture within the cavities of buildings. This comprehensive review attempts to investigate the potential performance outcomes resulting from the integration of photovoltaic/thermal systems (PV/Ts), phase change materials (PCMs), and heat pumps (HPs). After the screening process, 153 documents were selected to be synthesized, including 64 primary peer-reviewed publications, 20 standards, and 69 reviews or methodological articles. The results from experimental, field, and numerical studies have shown that cavity integration techniques are effective in achieving photovoltaic cooling, recovering useful heat, reducing heat flux, and supporting heat pump operation. Specifically, annual simulations showed a 6.5% reduction in heating electricity and coefficient of performance (COP) improvements of 22–26%, whereas short-term experiments reported COP gains of 3.3% on average and up to 8.6%. Hybrid (solar/thermal and waste heat recovery) system studies reported that combined heating and cooling energy can be saved by more than 50%. Yet, these results substantially varied with climate, cavity configuration, baseline system, control strategy, averaging period, and auxiliary energy usage. In general, PCM-integrated ventilated cavities can reduce summer heat gains while supporting controlled heat storage and release. However, in extreme weather conditions, application of PCMs may not be effective since complete phase transitions cannot be achieved. Therefore, future studies are recommended to focus on climate-responsive designs, validated hygrothermal models and controls, regulatory compliance, and life-cycle assessments.
Open AccessRecent Advances in Integrated Building Cavities: A Comprehensive Review of Fundamentals, Modeling, and Performance Evaluation
Currently, building envelopes are evolving from simple passive shields to smart systems. They control the exchange of energy, air, and moisture within the cavities of buildings. This comprehensive review attempts to investigate the potential performance outcomes resulting from the integration of photovoltaic/thermal systems (PV/Ts), phase change materials (PCMs), and heat pumps (HPs). After the screening process, 153 documents were selected to be synthesized, including 64 primary peer-reviewed publications, 20 standards, and 69 reviews or methodological articles. The results from experimental, field, and numerical studies have shown that cavity integration techniques are effective in achieving photovoltaic cooling, recovering useful heat, reducing heat flux, and supporting heat pump operation. Specifically, annual simulations showed a 6.5% reduction in heating electricity and coefficient of performance (COP) improvements of 22–26%, whereas short-term experiments reported COP gains of 3.3% on average and up to 8.6%. Hybrid (solar/thermal and waste heat recovery) system studies reported that combined heating and cooling energy can be saved by more than 50%. Yet, these results substantially varied with climate, cavity configuration, baseline system, control strategy, averaging period, and auxiliary energy usage. In general, PCM-integrated ventilated cavities can reduce summer heat gains while supporting controlled heat storage and release. However, in extreme weather conditions, application of PCMs may not be effective since complete phase transitions cannot be achieved. Therefore, future studies are recommended to focus on climate-responsive designs, validated hygrothermal models and controls, regulatory compliance, and life-cycle assessments.
- Open Access
Parametric Analysis of a Dual-Fluid Air–Refrigerant BIPV/T Façade Concept
A solar-assisted heat pump (SAHP) with a building-integrated photovoltaic/thermal (BIPV/T) façade evaporator is presented. The novelty of the proposed configuration is the integration of refrigerant-based PV cooling and controlled cavity airflow within a single façade evaporator, such that the airflow provides an additional heat source under low-solar conditions. The air-side and refrigerant-side CFD models were independently validated against published experimental data before being combined for the parametric analysis. Under the investigated peak condition, the maximum predicted solar thermal and electrical efficiencies were 46.6% and 14.9%, respectively. Under off-peak conditions, the parametric analysis identified strong thermo-hydraulic sensitivity to flow ratio, tube height, and tube pitch. For the optimized system geometry, the proposed system has the potential to recover up to 50% of the peak incident solar energy reference during off-peak solar conditions. Further experimental work is required to validate the findings of the numerical study.
Open AccessParametric Analysis of a Dual-Fluid Air–Refrigerant BIPV/T Façade Concept
A solar-assisted heat pump (SAHP) with a building-integrated photovoltaic/thermal (BIPV/T) façade evaporator is presented. The novelty of the proposed configuration is the integration of refrigerant-based PV cooling and controlled cavity airflow within a single façade evaporator, such that the airflow provides an additional heat source under low-solar conditions. The air-side and refrigerant-side CFD models were independently validated against published experimental data before being combined for the parametric analysis. Under the investigated peak condition, the maximum predicted solar thermal and electrical efficiencies were 46.6% and 14.9%, respectively. Under off-peak conditions, the parametric analysis identified strong thermo-hydraulic sensitivity to flow ratio, tube height, and tube pitch. For the optimized system geometry, the proposed system has the potential to recover up to 50% of the peak incident solar energy reference during off-peak solar conditions. Further experimental work is required to validate the findings of the numerical study.
- Open Access
- 12 June 2026
- Published by Frontiers Media SA in Frontiers in Sustainability
- Vol. 7, 1844355
Development of a novel hemp-based building material with enhanced thermal performance
Hempcrete is a bio-based building material that has gained attention for its potential environmental benefits, including carbon sequestration and lower embodied energy compared with conventional construction materials. While it is commonly used as a low-density insulating material, its thermal performance is insufficient for applications requiring higher energy efficiency, limiting its broader adoption and incorporation in future high-performance building design. This study investigates the development of a newly patented high-performance hemp-based non-load-bearing insulation block/infill (HPHB/I) with enhanced thermal performance through the use of alternative mineral binders and the incorporation of silica aerogel granulates. Lime, magnesium oxychloride (MOC), and magnesium phosphate (MPC) binders were evaluated, and the effects of binder-to-insulation ratio and aerogel content on density and thermal conductivity were systematically examined. The results show that both binder content and aerogel incorporation significantly influence the density and thermal conductivity of HPHB/I. Increasing binder content leads to higher thermal conductivity due to enhanced conduction in the solid matrix, while the addition of aerogel reduces thermal conductivity by modifying pore structure and suppressing heat transfer mechanisms. Magnesium-based binders demonstrated improved compatibility with hemp shives, enabling stable formulations at lower binder contents. The lowest thermal conductivity achieved by incorporating aerogel into the mix was approximately 0.020 W/m·K, representing a reduction of up to four times compared to conventional hemp-lime materials. Predictive regression models were developed to generalize the combined effects of binder ratio and aerogel content. The findings demonstrate that binder and performance-enhancing agent selection are critical for optimizing and developing bio-based materials with super-insulating properties suitable for high-performance building applications.
- 12 June 2026
- Published by Frontiers Media SA in Frontiers in Sustainability
- Vol. 7, 1844355
Open AccessDevelopment of a novel hemp-based building material with enhanced thermal performance
Hempcrete is a bio-based building material that has gained attention for its potential environmental benefits, including carbon sequestration and lower embodied energy compared with conventional construction materials. While it is commonly used as a low-density insulating material, its thermal performance is insufficient for applications requiring higher energy efficiency, limiting its broader adoption and incorporation in future high-performance building design. This study investigates the development of a newly patented high-performance hemp-based non-load-bearing insulation block/infill (HPHB/I) with enhanced thermal performance through the use of alternative mineral binders and the incorporation of silica aerogel granulates. Lime, magnesium oxychloride (MOC), and magnesium phosphate (MPC) binders were evaluated, and the effects of binder-to-insulation ratio and aerogel content on density and thermal conductivity were systematically examined. The results show that both binder content and aerogel incorporation significantly influence the density and thermal conductivity of HPHB/I. Increasing binder content leads to higher thermal conductivity due to enhanced conduction in the solid matrix, while the addition of aerogel reduces thermal conductivity by modifying pore structure and suppressing heat transfer mechanisms. Magnesium-based binders demonstrated improved compatibility with hemp shives, enabling stable formulations at lower binder contents. The lowest thermal conductivity achieved by incorporating aerogel into the mix was approximately 0.020 W/m·K, representing a reduction of up to four times compared to conventional hemp-lime materials. Predictive regression models were developed to generalize the combined effects of binder ratio and aerogel content. The findings demonstrate that binder and performance-enhancing agent selection are critical for optimizing and developing bio-based materials with super-insulating properties suitable for high-performance building applications.
- Open Access
The Significance of Using Temperature-Dependent Material Properties in Hygrothermal Performance Assessment of Exterior Wall Systems
The reliability of hygrothermal models depends on the quality of their inputs. Conventionally, thermal and moisture properties are treated as temperature-independent, yet previous studies have shown that many of these properties are temperature-dependent. This paper investigates the impact of using temperature-dependent material properties on hygrothermal simulation results compared to standard temperature-independent properties at the building envelope level. A representative exterior wood-frame wall assembly is modelled with constant material properties, including water vapour permeability, sorption isotherm, and water absorption coefficient corresponding to values measured at 3 °C, 21 °C, and 45 °C, as well as a case in which the properties vary with temperature. The variation in hygrothermal response is evaluated under several scenarios, including different climates (Toronto and Vancouver, Canada), cladding types (fibre cement and stucco), sheathing materials (oriented strand board (OSB) and plywood), and with and without rain-penetration load. Results indicate that the variation attributed to temperature-dependent material properties was greater for Vancouver than for Toronto and increased with rain penetration. In particular, the choice of cladding seemed to have a greater impact than the choice of sheathing material, with stucco showing greater differences than fibre cement. Overall, however, the temperature at which material properties are defined has a minimal impact on hygrothermal simulation results and wall performance assessments, with maximum hourly differences in sheathing moisture content (MC) differences ranging from 1.18 to 4.32 wt% without rain penetration. These findings demonstrate that the use of temperature-dependent material properties does not have a significant impact on the hygrothermal simulation results or the performance assessment of exterior wood-frame wall assemblies.
Open AccessThe Significance of Using Temperature-Dependent Material Properties in Hygrothermal Performance Assessment of Exterior Wall Systems
The reliability of hygrothermal models depends on the quality of their inputs. Conventionally, thermal and moisture properties are treated as temperature-independent, yet previous studies have shown that many of these properties are temperature-dependent. This paper investigates the impact of using temperature-dependent material properties on hygrothermal simulation results compared to standard temperature-independent properties at the building envelope level. A representative exterior wood-frame wall assembly is modelled with constant material properties, including water vapour permeability, sorption isotherm, and water absorption coefficient corresponding to values measured at 3 °C, 21 °C, and 45 °C, as well as a case in which the properties vary with temperature. The variation in hygrothermal response is evaluated under several scenarios, including different climates (Toronto and Vancouver, Canada), cladding types (fibre cement and stucco), sheathing materials (oriented strand board (OSB) and plywood), and with and without rain-penetration load. Results indicate that the variation attributed to temperature-dependent material properties was greater for Vancouver than for Toronto and increased with rain penetration. In particular, the choice of cladding seemed to have a greater impact than the choice of sheathing material, with stucco showing greater differences than fibre cement. Overall, however, the temperature at which material properties are defined has a minimal impact on hygrothermal simulation results and wall performance assessments, with maximum hourly differences in sheathing moisture content (MC) differences ranging from 1.18 to 4.32 wt% without rain penetration. These findings demonstrate that the use of temperature-dependent material properties does not have a significant impact on the hygrothermal simulation results or the performance assessment of exterior wood-frame wall assemblies.
- Open Access
- 2 April 2026
- Published by Elsevier in Journal of Building Engineering
- Vol. 124
Methodology for determining climate-specific effective PIR thermal conductivity and thickness values for energy modeling and code prescription: A case of flat roofs
- 2 April 2026
- Published by Elsevier in Journal of Building Engineering
- Vol. 124
Open AccessMethodology for determining climate-specific effective PIR thermal conductivity and thickness values for energy modeling and code prescription: A case of flat roofs
- Open Access
Applicability of a Heat Recovery Ventilator Retrofit in a Vancouver Residential House
Heat recovery systems are increasingly recognized as key energy conservation measures in residential buildings. But their effectiveness is highly sensitive to operational conditions. This study used a calibrated OpenStudio simulation, which is validated against monthly utility data, to investigate the feasibility of implementing a heat recovery ventilator in an existing single-detached house in Vancouver under two scenarios: existing passive ventilation without a heat recovery ventilator versus the proposed balanced mechanical ventilation with a heat recovery ventilator. The findings indicate that employing an HRV in an existing house lacking balanced ventilation would lead to higher annual space heating energy consumption (75.49 GJ electricity and 56.70 GJ natural gas with HRV compared to 73.64 GJ and 52.70 GJ, respectively, without an HRV). Therefore, for existing houses without balanced ventilation, improving the existing building envelope’s airtightness through retrofits should always be carried out before installing a heat recovery ventilator. Additionally, the heat recovery ventilator should be appropriately sized to compensate for any shortfall in natural infiltration to ensure the sufficient indoor air quality while minimizing the outdoor air-induced space heating energy usage. Furthermore, the recommended break-even point of the infiltration rate for the house studied in this work to avoid increased space heating energy use due to the retrofit with a heat recovery ventilator is 0.281 air change per hour.
Open AccessApplicability of a Heat Recovery Ventilator Retrofit in a Vancouver Residential House
Heat recovery systems are increasingly recognized as key energy conservation measures in residential buildings. But their effectiveness is highly sensitive to operational conditions. This study used a calibrated OpenStudio simulation, which is validated against monthly utility data, to investigate the feasibility of implementing a heat recovery ventilator in an existing single-detached house in Vancouver under two scenarios: existing passive ventilation without a heat recovery ventilator versus the proposed balanced mechanical ventilation with a heat recovery ventilator. The findings indicate that employing an HRV in an existing house lacking balanced ventilation would lead to higher annual space heating energy consumption (75.49 GJ electricity and 56.70 GJ natural gas with HRV compared to 73.64 GJ and 52.70 GJ, respectively, without an HRV). Therefore, for existing houses without balanced ventilation, improving the existing building envelope’s airtightness through retrofits should always be carried out before installing a heat recovery ventilator. Additionally, the heat recovery ventilator should be appropriately sized to compensate for any shortfall in natural infiltration to ensure the sufficient indoor air quality while minimizing the outdoor air-induced space heating energy usage. Furthermore, the recommended break-even point of the infiltration rate for the house studied in this work to avoid increased space heating energy use due to the retrofit with a heat recovery ventilator is 0.281 air change per hour.
- 19 December 2024
- Published by Springer Nature
- p. 358-363
Urban Heat Island Effect on Building Energy Consumption: ANN Method Application
- 19 December 2024
- Published by Springer Nature
- p. 358-363
Urban Heat Island Effect on Building Energy Consumption: ANN Method Application
- Open Access
ANN-Based Method for Urban Canopy Temperature Prediction and Building Energy Simulation with Urban Heat Island Effect in Consideration
The process of urbanization resulting from population growth is causing a transformation of natural landscapes into built environments, and contributing to a significant rise in air and surface temperatures in urban areas, resulting in what is known as the urban heat island (UHI). Ignoring the UHI effect and use of weather data from open fields and airport locations for energy and thermal comfort analysis can lead to over- and underestimation of heating and cooling loads, improper sizing of equipment, inefficiencies in the mechanical systems operation, and occupants’ thermal discomfort. There is a need for computationally efficient urban canopy temperature prediction models that account for the urban morphology and characteristics of the study area. This paper presents the development and application of an artificial neural network (ANN)-based method for generating hourly urban canopy temperature and local wind speed for energy simulation. It was used to predict the urban canopy temperature of a neighborhood in downtown Vancouver and the resulting building energy consumption and indoor temperature in a typical building in the area. The results showed that the UHI effect increased the total cooling energy demand by 23% and decreased the total heating energy consumption by 29%, resulting in an overall negative effect on the total energy demand of the building, which was 18% higher in the urban area. The UHI effect also increased the number of hours of indoor temperature above the cooling set point by 7.6%. The methodology can be applied to determine the urban canopy temperature of neighborhoods in different climate zones and determine the varying urban heat island effects associated with the locations.
Open AccessANN-Based Method for Urban Canopy Temperature Prediction and Building Energy Simulation with Urban Heat Island Effect in Consideration
The process of urbanization resulting from population growth is causing a transformation of natural landscapes into built environments, and contributing to a significant rise in air and surface temperatures in urban areas, resulting in what is known as the urban heat island (UHI). Ignoring the UHI effect and use of weather data from open fields and airport locations for energy and thermal comfort analysis can lead to over- and underestimation of heating and cooling loads, improper sizing of equipment, inefficiencies in the mechanical systems operation, and occupants’ thermal discomfort. There is a need for computationally efficient urban canopy temperature prediction models that account for the urban morphology and characteristics of the study area. This paper presents the development and application of an artificial neural network (ANN)-based method for generating hourly urban canopy temperature and local wind speed for energy simulation. It was used to predict the urban canopy temperature of a neighborhood in downtown Vancouver and the resulting building energy consumption and indoor temperature in a typical building in the area. The results showed that the UHI effect increased the total cooling energy demand by 23% and decreased the total heating energy consumption by 29%, resulting in an overall negative effect on the total energy demand of the building, which was 18% higher in the urban area. The UHI effect also increased the number of hours of indoor temperature above the cooling set point by 7.6%. The methodology can be applied to determine the urban canopy temperature of neighborhoods in different climate zones and determine the varying urban heat island effects associated with the locations.
- Open Access
Numerical Study of the Impact of Transverse Ribs on the Energy Potential of Air-Based BIPV/T Envelope Systems
Overheating in BIPV/T applications is a concern due to its negative impacts on the electrical conversion efficiency of the solar cells. Forced air cooling can be an effective thermal management strategy. However, its effectiveness is limited by the thermal resistance associated with the boundary layer formation on the walls of the air channel. The heat transfer effectiveness can be improved by appending transverse ribs to the BIPV/T air channel. This study numerically investigates the energy improvements associated with appending transverse ribs to a BIPV/T air channel using CFD. The impact of the varying the transverse rib roughness shape, pitch and height on the thermo-hydraulic performance parameter, electrical efficiency of the BIPV and building heating/cooling load is quantified. With the optimized transverse rib geometry, the heat removal rate is 2.73 times greater than with the smooth channel. This translated to a 30.5% reduction in the PV surface temperature and an increase in the electrical efficiency by 11.3% compared with the smooth channel under peak summer conditions for a mild oceanic climate. The wall heat gain during summer is also reduced by 45.2%.
Open AccessNumerical Study of the Impact of Transverse Ribs on the Energy Potential of Air-Based BIPV/T Envelope Systems
Overheating in BIPV/T applications is a concern due to its negative impacts on the electrical conversion efficiency of the solar cells. Forced air cooling can be an effective thermal management strategy. However, its effectiveness is limited by the thermal resistance associated with the boundary layer formation on the walls of the air channel. The heat transfer effectiveness can be improved by appending transverse ribs to the BIPV/T air channel. This study numerically investigates the energy improvements associated with appending transverse ribs to a BIPV/T air channel using CFD. The impact of the varying the transverse rib roughness shape, pitch and height on the thermo-hydraulic performance parameter, electrical efficiency of the BIPV and building heating/cooling load is quantified. With the optimized transverse rib geometry, the heat removal rate is 2.73 times greater than with the smooth channel. This translated to a 30.5% reduction in the PV surface temperature and an increase in the electrical efficiency by 11.3% compared with the smooth channel under peak summer conditions for a mild oceanic climate. The wall heat gain during summer is also reduced by 45.2%.