Sanjeev Saksena
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sanjeev Saksena has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Atul Prakash
Echocardiography Core Laboratory, Electrophysiology Research Foundation, Warren, NJ 07059, USA
1 shared publicationBerndt Luderitz
Electrophysiology Research Foundation
1 shared publicationD. George Wyse
University of Calgary and Calgary Health Region
1 shared publicationDouglas A. Hettrick
Medtronic, Inc
1 shared publicationNavin C. Nanda
University of Alabama at Birmingham
1 shared publicationPaul D. Ziegler
Medtronic, Inc
1 shared publication
Latest Publications
- Open Access
- 12 May 2011
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 31 (1) , 1-2
Twenty years of interventional cardiac electrophysiology: Meeting future challenges with continuing innovations
- 12 May 2011
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 31 (1) , 1-2
Open AccessTwenty years of interventional cardiac electrophysiology: Meeting future challenges with continuing innovations
- 29 January 2011
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 30 (1) , 1-3
Twenty-five years of implantable defibrillator practice in the USA: Are we ready for globalization?
- 29 January 2011
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 30 (1) , 1-3
Twenty-five years of implantable defibrillator practice in the USA: Are we ready for globalization?
- 12 December 2006
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 16 (3) , 139-140
The journal in 2007: Defining new frontiers
- 12 December 2006
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 16 (3) , 139-140
The journal in 2007: Defining new frontiers
- 1 April 2005
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 12 (3) , 177-187
Dual Site Right Atrial Pacing can Improve the Impact of Standard Dual Chamber Pacing on Atrial and Ventricular Mechanical Function in Patients with Symptomatic Atrial Fibrillation: Further Observations from the Dual Site Atrial Pacing for Prevention of Atrial Fibrillation Trial
Background: The effects of atrial pacing mode on atrial and ventricular function in patients with atrial fibrillation (AF) and bradycardia have not been evaluated. We evaluated atrial and ventricular function during randomization to support pacing (SP), high right atrial pacing (HRA), and dual site right atrial pacing (DAP). Methods: Seventy-nine patients (66 ± 12 yr, 46 male) with standard pacing indications and symptomatic AF were randomized to each of three pacing modes (DAP, HRA, SP) for 6 months in a crossover design. Echocardiographic studies were performed at enrollment and the end of each mode. Paired comparisons of atrial and ventricular function parameters were performed between each pacing mode and baseline. Results: HRA pacing in DDDR mode resulted in increased left ventricular (LV) end systolic volume (78 ± 42 vs. 60 ± 31 ml, p = 0.001) and reduced LV ejection fraction (44 ± 14 vs. 50 ± 11%, p = 0.007) compared to baseline. These parameters did not change during DAP. DAP resulted in increased peak A wave velocity (75 ± 19 vs. 63 ± 23 cm/s, p = 0.003) and atrial filling fraction compared to baseline (0.47 ± 0.15 vs. 0.38 ± 0.13, p = 0.005). Atrial and ventricular function were similar between control and SP. Conclusion: DAP, but not HRA or SP, improved left atrial (LA) function in patients with AF and bradycardia. HRA pacing in DDDR mode resulted in LA dilatation and deterioration of LV function which was not observed with DAP.
- 1 April 2005
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 12 (3) , 177-187
Dual Site Right Atrial Pacing can Improve the Impact of Standard Dual Chamber Pacing on Atrial and Ventricular Mechanical Function in Patients with Symptomatic Atrial Fibrillation: Further Observations from the Dual Site Atrial Pacing for Prevention of Atrial Fibrillation Trial
Background: The effects of atrial pacing mode on atrial and ventricular function in patients with atrial fibrillation (AF) and bradycardia have not been evaluated. We evaluated atrial and ventricular function during randomization to support pacing (SP), high right atrial pacing (HRA), and dual site right atrial pacing (DAP). Methods: Seventy-nine patients (66 ± 12 yr, 46 male) with standard pacing indications and symptomatic AF were randomized to each of three pacing modes (DAP, HRA, SP) for 6 months in a crossover design. Echocardiographic studies were performed at enrollment and the end of each mode. Paired comparisons of atrial and ventricular function parameters were performed between each pacing mode and baseline. Results: HRA pacing in DDDR mode resulted in increased left ventricular (LV) end systolic volume (78 ± 42 vs. 60 ± 31 ml, p = 0.001) and reduced LV ejection fraction (44 ± 14 vs. 50 ± 11%, p = 0.007) compared to baseline. These parameters did not change during DAP. DAP resulted in increased peak A wave velocity (75 ± 19 vs. 63 ± 23 cm/s, p = 0.003) and atrial filling fraction compared to baseline (0.47 ± 0.15 vs. 0.38 ± 0.13, p = 0.005). Atrial and ventricular function were similar between control and SP. Conclusion: DAP, but not HRA or SP, improved left atrial (LA) function in patients with AF and bradycardia. HRA pacing in DDDR mode resulted in LA dilatation and deterioration of LV function which was not observed with DAP.