Christopher González
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christopher González has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Bárbara Rodríguez
Centro de Investigación en Recursos Naturales y Sustentabilidad (CIRENYS), Universidad Bernardo O'Higgins, Avenida Viel 1497, Santiago de Chile, Chile; Escuela de Química y Farmacia, Facultad de Ciencias Médicas, Universidad Bernardo O'Higgins, General Gana, 1702, Santiago, Chile
2 shared publications - Iván Martínez
Departamento de Ciencias Químicas y Biológicas, Facultad de Ciencias de la Salud, Universidad Bernardo O'Higgins, General Gana, 1702, Santiago, Chile
2 shared publications Alejandra García
1 shared publication- Alejandro Gaita-Ariño
Instituto de Ciencia Molecular (ICMol), Universitat de València, Paterna, Spain
1 shared publication Aurelien Do
WES Consultoría y Proyectos SpA (WES) Nueva Providencia 1945 Providencia, Chile
1 shared publicationBruce K. Cassels
Department of Chemistry, Faculty of Sciences University of Chile Santiago Chile
1 shared publication
Latest Publications
- 1 March 2026
- Published by Elsevier in Journal of Environmental Management
- Vol. 402, 129143
Tertiary treatment of domestic wastewater for reuse: Implementation and evaluation in a rural context in Chile
- 1 March 2026
- Published by Elsevier in Journal of Environmental Management
- Vol. 402, 129143
Tertiary treatment of domestic wastewater for reuse: Implementation and evaluation in a rural context in Chile
- 16 May 2025
- Published by Royal Society of Chemistry (RSC) in Dalton Transactions
- Vol. 54 (28) , 10873-10882
SIMDAVIS 1.2: phosphonates are outstanding SIM ligands. Crown ethers are not
This study presents SIMDAVIS 1.2, an updated dataset and analysis tool for lanthanide-based single-ion magnets (Ln-SIMs), focusing on the role of various ligands in influencing their magnetic properties. The revised dataset, accessible via a user-friendly online dashboard, encompasses over 10 000 data points on chemical and physical properties derived from more than 400 publications. Notably, the study redefines ligand classifications, introducing phosphonate-based ligands as a distinct family and highlighting their superior performance as SIM ligands compared to less effective alternatives such as crown ethers. Phosphonates exhibit promising pentagonal bipyramidal geometries that enhance magnetic stability by minimizing low-energy vibrational interactions. Comparative analysis reveals that while phosphonates may have moderate Ueff values compared to other leading ligands, their magnetic memory and hysteresis properties are comparable to those of bis-phthalocyaninato or metallocene sandwiches. This work emphasizes the importance of rational ligand selection and frugal data-driven approaches in the design of effective Ln-SIMs, contributing valuable insights into the optimization of single-ion magnet design strategies.
- 16 May 2025
- Published by Royal Society of Chemistry (RSC) in Dalton Transactions
- Vol. 54 (28) , 10873-10882
SIMDAVIS 1.2: phosphonates are outstanding SIM ligands. Crown ethers are not
This study presents SIMDAVIS 1.2, an updated dataset and analysis tool for lanthanide-based single-ion magnets (Ln-SIMs), focusing on the role of various ligands in influencing their magnetic properties. The revised dataset, accessible via a user-friendly online dashboard, encompasses over 10 000 data points on chemical and physical properties derived from more than 400 publications. Notably, the study redefines ligand classifications, introducing phosphonate-based ligands as a distinct family and highlighting their superior performance as SIM ligands compared to less effective alternatives such as crown ethers. Phosphonates exhibit promising pentagonal bipyramidal geometries that enhance magnetic stability by minimizing low-energy vibrational interactions. Comparative analysis reveals that while phosphonates may have moderate Ueff values compared to other leading ligands, their magnetic memory and hysteresis properties are comparable to those of bis-phthalocyaninato or metallocene sandwiches. This work emphasizes the importance of rational ligand selection and frugal data-driven approaches in the design of effective Ln-SIMs, contributing valuable insights into the optimization of single-ion magnet design strategies.
- Open Access
Antibiofilm Effects of Modifying Polyvinylidene Fluoride Membranes with Polyethylenimine, Poly(acrylic acid) and Graphene Oxide
Biofouling in membrane filtration systems poses significant operational challenges, leading to decreased permeate flux. The aim of this work was to study the anti-biofilm properties of new nanofiltration membranes produced via layer-by-layer, LBL, assembly by coating a polyvinylidene fluoride (PVDF) support with a polyethylenimine (PEI) and poly(acrylic acid)/graphene oxide (PAA-GO) mixture. The membranes were characterized according to contact angle, scanning electron microscopy (SEM), atomic force microscopy and their Z-potential. Biofilm quantification and characterization were carried out using crystal violet staining and SEM, while bacterial viability was assessed by using colony-forming units. The membrane with three bilayers ((PAA-PEI)3/PVDF) showed a roughness of 77.78 nm. The incorporation of GO ((GO/PAA-PEI)3/PVDF) produced a membrane with a smoother surface (roughness of 26.92 nm) and showed salt rejections of 16% and 68% for NaCl and Na2SO4, respectively. A significant reduction, ranging from 82.37 to 77.30%, in biofilm formation produced by S. aureus and E. coli were observed on modified membranes. Additionally, the bacterial viability on the modified membranes was markedly reduced (67.42–99.98%). Our results show that the modified membranes exhibited both antibiofilm and antimicrobial capacities, suggesting that these properties mainly depend on the properties of the modifying agents, as the initial adherence on the membrane surface was not totally suppressed, but the proliferation and formation of EPSs were prevented.
Open AccessAntibiofilm Effects of Modifying Polyvinylidene Fluoride Membranes with Polyethylenimine, Poly(acrylic acid) and Graphene Oxide
Biofouling in membrane filtration systems poses significant operational challenges, leading to decreased permeate flux. The aim of this work was to study the anti-biofilm properties of new nanofiltration membranes produced via layer-by-layer, LBL, assembly by coating a polyvinylidene fluoride (PVDF) support with a polyethylenimine (PEI) and poly(acrylic acid)/graphene oxide (PAA-GO) mixture. The membranes were characterized according to contact angle, scanning electron microscopy (SEM), atomic force microscopy and their Z-potential. Biofilm quantification and characterization were carried out using crystal violet staining and SEM, while bacterial viability was assessed by using colony-forming units. The membrane with three bilayers ((PAA-PEI)3/PVDF) showed a roughness of 77.78 nm. The incorporation of GO ((GO/PAA-PEI)3/PVDF) produced a membrane with a smoother surface (roughness of 26.92 nm) and showed salt rejections of 16% and 68% for NaCl and Na2SO4, respectively. A significant reduction, ranging from 82.37 to 77.30%, in biofilm formation produced by S. aureus and E. coli were observed on modified membranes. Additionally, the bacterial viability on the modified membranes was markedly reduced (67.42–99.98%). Our results show that the modified membranes exhibited both antibiofilm and antimicrobial capacities, suggesting that these properties mainly depend on the properties of the modifying agents, as the initial adherence on the membrane surface was not totally suppressed, but the proliferation and formation of EPSs were prevented.
- Open Access
- 7 March 2024
- Published by Elsevier in International Journal of Electrochemical Science
- Vol. 19 (4)
Electrochemical detection of 17β-estradiol and bisphenol A using graphene oxide and reduced graphene oxide modified electrodes: A review
- 7 March 2024
- Published by Elsevier in International Journal of Electrochemical Science
- Vol. 19 (4)
Open AccessElectrochemical detection of 17β-estradiol and bisphenol A using graphene oxide and reduced graphene oxide modified electrodes: A review
- 15 June 2012
- Published by Wiley in Journal of Physical Organic Chemistry
- Vol. 25 (11) , 946-952
Nucleophilic reactivity of biothiols toward coumarin‐based derivatives containing a chalcone moiety
The Michael addition reactions of the biothiols cysteine (Cys), glutathione (GSH), homocysteine (Hcy) and cysteinylglycine (Cys‐Gly) with (E)‐3‐(3‐(2‐methoxyphenyl)acryloyl)‐7‐methoxy‐2H‐chromen‐2‐one and (E)‐3‐(3‐(3‐methoxyphenyl)acryloyl)‐7‐methoxy‐2H‐chromen‐2‐one (ChC2 and ChC3, respectively) in aqueous solution (25 °C, ionic strength 0.2 M KCl) were followed fluorimetrically and evaluated kinetically. With a large excess of biothiol, pseudo‐first‐order rate coefficients (kobsd) were found. Plots of kobsd versus [biothiolate] are linear, with a pH‐independent slope (kN). With the kinetic results obtained, the following conclusions can be drawn: (i) the reactivity increases in the sequence Cys‐Gly < Hcy < GSH < Cys; (ii) similar reactivity toward biothiols was found for ChC2 and ChC3, and both probes are more reactive than (E)‐3‐cinnamoyl‐7‐methoxy‐2H‐chromen‐2‐one (ChC1); (iii) ChC2 and ChC3 display a highly selective fluorescence enhancement with biothiols, allowing these probes to be used for fluorimetric biothiol determination in SH‐SY5Y cells. Copyright © 2012 John Wiley & Sons, Ltd.
- 15 June 2012
- Published by Wiley in Journal of Physical Organic Chemistry
- Vol. 25 (11) , 946-952
Nucleophilic reactivity of biothiols toward coumarin‐based derivatives containing a chalcone moiety
The Michael addition reactions of the biothiols cysteine (Cys), glutathione (GSH), homocysteine (Hcy) and cysteinylglycine (Cys‐Gly) with (E)‐3‐(3‐(2‐methoxyphenyl)acryloyl)‐7‐methoxy‐2H‐chromen‐2‐one and (E)‐3‐(3‐(3‐methoxyphenyl)acryloyl)‐7‐methoxy‐2H‐chromen‐2‐one (ChC2 and ChC3, respectively) in aqueous solution (25 °C, ionic strength 0.2 M KCl) were followed fluorimetrically and evaluated kinetically. With a large excess of biothiol, pseudo‐first‐order rate coefficients (kobsd) were found. Plots of kobsd versus [biothiolate] are linear, with a pH‐independent slope (kN). With the kinetic results obtained, the following conclusions can be drawn: (i) the reactivity increases in the sequence Cys‐Gly < Hcy < GSH < Cys; (ii) similar reactivity toward biothiols was found for ChC2 and ChC3, and both probes are more reactive than (E)‐3‐cinnamoyl‐7‐methoxy‐2H‐chromen‐2‐one (ChC1); (iii) ChC2 and ChC3 display a highly selective fluorescence enhancement with biothiols, allowing these probes to be used for fluorimetric biothiol determination in SH‐SY5Y cells. Copyright © 2012 John Wiley & Sons, Ltd.