Bappa Roy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bappa Roy has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Subir Datta
Mizoram University
6 shared publications Shuma Adhikari
National Institute of Technology Manipur
5 shared publicationsAribam Deleena Devi
National Institute of Technology Silchar
2 shared publications- Taha Selim Ustun
Fukushima Renewable Energy Institute (FREA), National Institute of Advanced Industrial Science and Technology (AIST), Fukushima 963-0298, Japan
2 shared publications Akibul Islam
Mizorant University,Department of Electrical Engineering,Aizawl,Mizoram,India
1 shared publication- Aribam Deleena Devi
Electrical Engineering Department, National Institute of Technology Silchar, Silchar 788010, Assam, India
1 shared publication
Latest Publications
- Open Access
- 4 November 2024
- Published by MDPI AG in Electricity
- Vol. 5 (4) , 843-860
Harnessing Deep Learning for Enhanced MPPT in Solar PV Systems: An LSTM Approach Using Real-World Data
Maximum Power Point Tracking (MPPT) is essential for maximizing the efficiency of solar photovoltaic (PV) systems. While numerous MPPT methods exist, practical implementations often lean towards conventional techniques due to their simplicity. However, these traditional methods can struggle with rapid fluctuations in solar irradiance and temperature. This paper introduces a novel deep learning-based MPPT algorithm that leverages a Long Short-Term Memory (LSTM) deep neural network (DNN) to effectively track maximum power from solar PV panels, utilizing real-world data. The simulations of three algorithms—Perturb and Observe (P&O), Artificial Neural Network (ANN), and the proposed LSTM-based MPPT—were conducted using MATLAB (2021b) and RT_LAB (24.3.3) with an OPAL-RT simulator for real-time analysis. The data used for this study were sourced from NASA/POWER’s Native Resolution Daily Data of solar irradiation and temperature specific to Imphal, Manipur, India. The obtained results demonstrate that the LSTM-based MPPT system achieves a superior power tracking accuracy under changing solar conditions, producing an average output of 74 W. In comparison, the ANN and P&O methods yield average outputs of 57 W and 62 W, respectively. This significant improvement, i.e., 20–30%, underscores the effectiveness of the LSTM technique in enhancing the power output of solar PV systems. By incorporating real-world data, valuable insights into solar power generation specific to the selected location are provided. Furthermore, the outputs of the model were verified through real-time simulations using the OPAL-RT simulator OP4510, showcasing the practical applicability of this approach in real-world scenarios.
- 4 November 2024
- Published by MDPI AG in Electricity
- Vol. 5 (4) , 843-860
Open AccessHarnessing Deep Learning for Enhanced MPPT in Solar PV Systems: An LSTM Approach Using Real-World Data
Maximum Power Point Tracking (MPPT) is essential for maximizing the efficiency of solar photovoltaic (PV) systems. While numerous MPPT methods exist, practical implementations often lean towards conventional techniques due to their simplicity. However, these traditional methods can struggle with rapid fluctuations in solar irradiance and temperature. This paper introduces a novel deep learning-based MPPT algorithm that leverages a Long Short-Term Memory (LSTM) deep neural network (DNN) to effectively track maximum power from solar PV panels, utilizing real-world data. The simulations of three algorithms—Perturb and Observe (P&O), Artificial Neural Network (ANN), and the proposed LSTM-based MPPT—were conducted using MATLAB (2021b) and RT_LAB (24.3.3) with an OPAL-RT simulator for real-time analysis. The data used for this study were sourced from NASA/POWER’s Native Resolution Daily Data of solar irradiation and temperature specific to Imphal, Manipur, India. The obtained results demonstrate that the LSTM-based MPPT system achieves a superior power tracking accuracy under changing solar conditions, producing an average output of 74 W. In comparison, the ANN and P&O methods yield average outputs of 57 W and 62 W, respectively. This significant improvement, i.e., 20–30%, underscores the effectiveness of the LSTM technique in enhancing the power output of solar PV systems. By incorporating real-world data, valuable insights into solar power generation specific to the selected location are provided. Furthermore, the outputs of the model were verified through real-time simulations using the OPAL-RT simulator OP4510, showcasing the practical applicability of this approach in real-world scenarios.
- 3 October 2023
- Published by Springer Nature
- p. 49-58
Real-Time Simulation of an Islanded Mode Solar PV System with New Elman NN-Based MPPT
- 3 October 2023
- Published by Springer Nature
- p. 49-58
Real-Time Simulation of an Islanded Mode Solar PV System with New Elman NN-Based MPPT
- Top Cited PapersOpen Access
- 13 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 62674-62696
Deep Learning Based Relay for Online Fault Detection, Classification, and Fault Location in a Grid-Connected Microgrid
In this article, a maiden attempt have been taken for the online detection of faults, classification of faults, and identification of the fault locations of a grid-connected Micro-grid (MG) system. A deep learning algorithm-based Long Short Term Memory (LSTM) network is proposed, for the first time, for the online detection of faults and their classifications of the considered MG system to overcome the issues that persist in the existing algorithms. Also, a combination of an LSTM network and feed-forward neural network (FFNN) with a back-propagation algorithm (BPA) is proposed to identify the exact locations of the faults since the identification of fault locations is more challenging than fault categorizations. To select a suitable deep learning network with multiple hidden layers for achieving the aforesaid objectives, a rigorous analysis has been done. To study the accuracy of the proposed techniques, different types of faults with different parameters are considered in this paper. An extensive simulation has been done in MATLAB/Simulink platform to study the performance of the system with the proposed techniques. To validate the effectiveness of the proposed techniques, the entire system is implemented in the real-time platform using the OPAL-RT digital simulator. Comparison has also been done for the results obtained using ANN and proposed techniques. The results show that the proposed techniques based on the deep learning network effectively detect, classify, and identify the location of different faults of an MG system with acceptable performances.
- 13 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 62674-62696
Top Cited PapersOpen AccessDeep Learning Based Relay for Online Fault Detection, Classification, and Fault Location in a Grid-Connected Microgrid
In this article, a maiden attempt have been taken for the online detection of faults, classification of faults, and identification of the fault locations of a grid-connected Micro-grid (MG) system. A deep learning algorithm-based Long Short Term Memory (LSTM) network is proposed, for the first time, for the online detection of faults and their classifications of the considered MG system to overcome the issues that persist in the existing algorithms. Also, a combination of an LSTM network and feed-forward neural network (FFNN) with a back-propagation algorithm (BPA) is proposed to identify the exact locations of the faults since the identification of fault locations is more challenging than fault categorizations. To select a suitable deep learning network with multiple hidden layers for achieving the aforesaid objectives, a rigorous analysis has been done. To study the accuracy of the proposed techniques, different types of faults with different parameters are considered in this paper. An extensive simulation has been done in MATLAB/Simulink platform to study the performance of the system with the proposed techniques. To validate the effectiveness of the proposed techniques, the entire system is implemented in the real-time platform using the OPAL-RT digital simulator. Comparison has also been done for the results obtained using ANN and proposed techniques. The results show that the proposed techniques based on the deep learning network effectively detect, classify, and identify the location of different faults of an MG system with acceptable performances.
- 26 October 2022
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 18 (3) , 2087-2102
Real-Time Simulation of a Wind-Solar-Battery Based Microgrid System
- 26 October 2022
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 18 (3) , 2087-2102
Real-Time Simulation of a Wind-Solar-Battery Based Microgrid System
- 3 March 2020
- Published by Springer Nature
- p. 373-382
Grid Connected PMSG Based Wind Energy Conversion System Using Back-to-Back Converter
- 3 March 2020
- Published by Springer Nature
- p. 373-382
Grid Connected PMSG Based Wind Energy Conversion System Using Back-to-Back Converter
- 3 March 2020
- Published by Springer Nature
- p. 313-320
Detection and Classification of Fault in Transmission Line Using PAC Technology Based Real Time SCADA System
- 3 March 2020
- Published by Springer Nature
- p. 313-320
Detection and Classification of Fault in Transmission Line Using PAC Technology Based Real Time SCADA System
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Performance Study of UPQC under Non-linear 1oad, Unbalance linear 1oad, Symmetrical and Asymmetrical Faults
In this paper, the performance of a Unified Power Quality Conditioner (UPQC) is studied under nonlinear and unbalanced linear loads and also during symmetrical and asymmetrical faults. Two control schemes are used to regulate the UPQC. One of the control schemes are used for injecting/absorbing the requited amount of voltage into/from the line to maintain rated voltage during voltage sag/swell conditions whereas other is used for injecting current into the line to reduce harmonics during non-linear loads. Simulation is done using MATLAB/Simulink software and simulink results are analyzed.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Performance Study of UPQC under Non-linear 1oad, Unbalance linear 1oad, Symmetrical and Asymmetrical Faults
In this paper, the performance of a Unified Power Quality Conditioner (UPQC) is studied under nonlinear and unbalanced linear loads and also during symmetrical and asymmetrical faults. Two control schemes are used to regulate the UPQC. One of the control schemes are used for injecting/absorbing the requited amount of voltage into/from the line to maintain rated voltage during voltage sag/swell conditions whereas other is used for injecting current into the line to reduce harmonics during non-linear loads. Simulation is done using MATLAB/Simulink software and simulink results are analyzed.