BDBiao Deng

Biao Deng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Biao Deng has a total of 32 co-authors. Here are the top co-authors by number of shared publications:

  • Fen Tao

    3 shared publications
  • Jun Wang

    Shanghai Synchrotron Radiation Facility Shanghai Advanced Research Institute Chinese Academy of Sciences 201204 Shanghai China

    3 shared publications
  • Bo Su

    Shanghai Synchrotron Radiation Facility, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai, China

    2 shared publications
  • Ling Zhang

    Shanghai Synchrotron Radiation Facility Shanghai Advanced Research Institute Chinese Academy of Sciences 201204 Shanghai China

    2 shared publications
  • Ling Zhang

    Shanghai Synchrotron Radiation Facility, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, People's Republic of China

    2 shared publications
  • Ai-Guo Li

    Shanghai Synchrotron Radiation Facility, Shanghai Advanced Research Institute, Chinese Academy of Sciences, No.239 Zhangheng Road, Shanghai 201210, People's Republic of China

    1 shared publication

Latest Publications

  • Open Access

    Super-resolution reconstruction of synchrotron radiation nano-CT images and its applications

    by Zhen Peng, Ao Wang, Jun Wang, Fen Tao, Ling Zhang, Guohao DU, Biao Deng

    BackgroundSynchrotron radiation nano-computed tomography (nano-CT) is widely applied in materials science, energy research, and geology due to its capability to provide high-resolution three-dimensional structural information at the nanoscale. However, environmental interference, equipment limitations, and light source fluctuations often degrade image quality, leading to reduced signal-to-noise ratio, blurring, and loss of critical details, which severely impact quantitative analysis and segmentation accuracy for microstructures such as cracks and pores. While existing super-resolution (SR) techniques for natural images have significant advantages, their adaptation to nano-CT remains challenged by dataset scarcity and stringent reconstruction accuracy requirements.PurposeThis study aims to develop a dedicated super-resolution reconstruction network for synchrotron radiation nano-CT images to enhance the clarity and detail restoration of low-quality CT images and investigate its efficacy in optimizing downstream tasks such as crack segmentation.MethodsFirstly, a Transformer-based U-shaped symmetric network for SR (UTSR) was proposed, integrating a Double Convolutional Feedforward Network (DCFFN) and a Grouped Multi-scale Window Self-Attention (GMSA) mechanism to achieve efficient reconstruction through multi-level feature extraction and hierarchical processing. Then, a transfer learning strategy was adopted, leveraging natural image datasets for pre-training and fine-tuning the model with nano-CT data from the Shanghai Synchrotron Radiation Facility (SSRF) to address dataset scarcity. Finally, a Sobel edge loss function was introduced to prioritize texture preservation, and a two-stage training framework (general image pre-training and nano-CT fine-tuning) was implemented to optimize model performances in terms of Natural Image Quality Evaluator (NIQE), Learned Perceptual Image Patch Similarity (LPIPS), Deep Image Structure and Texture Similarity (DISTS), Peak Signal-to-Noise Ratio (PSNR) and Structural Similarity Index Measure (SSIM).ResultsComparison results show that UTSR demonstrates superior performance on both simulated and nano-CT datasets: it achieves lower NIQE (9.38) and LPIPS (0.312) scores compared to SwinIR and Real-ESRGAN, alongside reduced computational complexity (45.72G FLOPs). When applied to crack segmentation, UTSR-processed images attain an accuracy of 99.3%, with a 24.5% improvement in recall and a 19.1% increase in F1 Score over original images. Ablation experiments confirm the effectiveness of the DCFFN module, where its combination with GMSA further reduces NIQE to 10.99.ConclusionsThe UTSR network effectively addresses the challenges of low-quality synchrotron radiation nano-CT images and scarce datasets through its innovative architecture and transfer learning strategy, providing a robust preprocessing solution for microstructural analysis, hence expands the application of deep learning-based super-resolution in scientific imaging, offering substantial academic and engineering value.

  • Open Access

    Multiscale multi-technique characterization of the pore network structure for nickel-iron-based industrial catalysts

    by Yanwei Huang, Fen Tao, Ling Zhang, Jun Wang, Guohao Du, Tiqiao Xiao, Biao Deng

    Pore structures, critical for catalyst mass transfer efficiency and active site accessibility, present a cross-scale complexity that challenges conventional characterization methods. This study integrated synchrotron multiscale CT, mercury intrusion porosimetry, and N2 adsorption (N2 adsorption) to achieve a comprehensive, full-scale analysis of the pore network in Ni-Fe industrial catalysts, spanning 1.48 nm to 365 μm. Through 3D reconstruction, the study unveiled complex structural features, such as cavity structures and “ink-bottle” pores, which are hard to capture with traditional single techniques. Comparing results from the three methods clarified the limitations of conventional approaches in analyzing complex pore sizes. Based on the pore characteristics of Ni-Fe catalysts, this study proposes a hierarchical pore structure design to optimize mass transfer and enhance performance. The integration of multiple techniques achieved complementary advantages, and the in-depth analysis based on this multimodal approach provides quantitative guidance for catalyst optimization and preparation. The findings offer a theoretical basis for developing more efficient and stable industrial catalysts and advancing catalyst design toward a digital and rational approach.


  • Open Access

    A study of structural effects on the focusing and imaging performance of hard X-rays with 20–30 nm zone plates

    by Xujie Tong, Vishal Dhamgaye, Qiucheng Chen, Qingxin Wu, Biao Deng, Ling Zhang, Oliver Fox, Hongchang Wang, Jun Zhao, Yifang Chen, et al.

    Hard X-ray microscopes with 20–30 nm spatial resolution ranges are an advanced tool for the inspection of materials at the nanoscale. However, the limited efficiency of the focusing optics, for example, a Fresnel zone plate (ZP) lens, can significantly reduce the power of a nanoprobe. Despite several reports on ZP lenses that focus hard X-rays with 20 nm resolution – mainly constructed by zone-doubling techniques – a systematic investigation into the limiting factors has not been reported. We report the structural effects on the focusing and imaging efficiency of 20–30 nm-resolution ZPs, employing a modified beam-propagation method. The zone width and the duty cycle (zone width/ring pitch) were optimized to achieve maximum efficiency, and a comparative analysis of the zone materials was conducted. The optimized zone structures were used in the fabrication of Pt-hydrogen silsesquioxane (HSQ) ZPs. The highest focusing efficiency of the Pt-HSQ-ZP with a resolution of 30 nm was 10% at 7 keV and >5% in the range 6–10 keV, whereas the highest efficiency of the Pt-HSQ-ZP with a resolution of 20 nm was realized at 7 keV with an efficiency of 7.6%. Optical characterization conducted at X-ray beamlines demonstrated significant enhancement of the focusing and imaging efficiency in a broader range of hard X-rays from 5 keV to 10 keV, demonstrating the potential application in hard X-ray focusing and imaging.


  • The 3D nanoimaging beamline at SSRF

    by Ling Zhang, Fen Tao, Jun Wang, Ruo-Yang Gao, Bo Su, Guo-Hao Du, Ai-Guo Li, Ti-Qiao Xiao, Biao Deng


  • Open Access

    Full-field hard X-ray nano-tomography at SSRF

    by Fen Tao, Jun Wang, Guohao Du, Bo Su, Ling Zhang, Chen Hou, Biao Deng, Tiqiao Xiao

    An in-house designed transmission X-ray microscopy (TXM) instrument has been developed and commissioned at beamline BL18B of the Shanghai Synchrotron Radiation Facility (SSRF). BL18B is a hard (5–14 keV) X-ray bending-magnet beamline recently built with sub-20 nm spatial resolution in TXM. There are two kinds of resolution mode: one based on using a high-resolution-based scintillator-lens-coupled camera, and the other on using a medium-resolution-based X-ray sCMOS camera. Here, a demonstration of full-field hard X-ray nano-tomography for high-Z material samples (e.g. Au particles, battery particles) and low-Z material samples (e.g. SiO2 powders) is presented for both resolution modes. Sub-50 nm to 100 nm resolution in three dimensions (3D) has been achieved. These results represent the ability of 3D non-destructive characterization with nano-scale spatial resolution for scientific applications in many research fields.