Lorenzo Becce
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lorenzo Becce has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Fabrizio Mazzetto
Faculty of Agricultural, Environmental and Food Sciences, Free University of Bozen-Bolzano, 39100 Bolzano, Italy
15 shared publications - Giovanni Carabin
Free University of Bozen-Bolzano
9 shared publications - Ayesha Ali
Faculty of Agricultural, Environmental, Food Sciences, Free University of Bozen-Bolzano (unibz), Piazza Università 1, 39100 Bozen-Bolzano, Italy
5 shared publications - Andreas Gronauer
Faculty of Agricultural, Environmental and Food Sciences, Free University of Bozen-Bolzano (unibz), Piazza Università 1, 39100 Bozen-Bolzano, Italy
4 shared publications - Andreas Mandler
Free University of Bozen-Bolzano
4 shared publications - Francesco Fabio Nicolosi
Free University of Bozen-Bolzano
4 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by MDPI AG in Agriengineering
- Vol. 8 (1) , 3
Methodological Advancement in Resistive-Based, Real-Time Spray Deposition Assessment with Multiplexed Acquisition
The use of agrochemicals remains indispensable for ensuring fruit production; however, their excessive or inefficient application poses significant environmental and health concerns. Rapid detection of spray deposition is crucial for assessing sprayer performance, improving precision application, and reducing drift and chemical waste. In this context, real-time monitoring technologies represent a promising tool to promote sustainable and efficient crop protection practices. This study refines previous experiences with an array of resistive sensors to quickly measure spray deposition. First, a multi-point calibration curve is introduced to improve the sensors’ accuracy. Furthermore, a multiplexed acquisition system (Sciospec ISX-5) is employed to enable time-resolved measurements of the whole sensor array. The method is validated by spectrophotometry and weight measurements. Wind tunnel trials with fluorescein (FLU) and fluorescein + potassium chloride (FLU + KCl) tracing solutions were conducted. The conductivity of the latter was higher than the former, without biasing the measurement. Both tracers showed good correlation between deposition and conductivity (R2 = 0.997 for FLU and 0.995 for FLU + KCl), and the maximum deviation from the spectrophotometric estimates was <10%. Time-resolved measurement showed the build-up of deposition over time, potentially indicating the dimensional composition of the sprayed cloud. The improved workflow provides array-wide, sequential deposition measurements, enabling faster on-site acquisition and efficient analysis. The results demonstrate strong potential for scaling the method to field applications, supporting its further development into real-time deposition mapping tools that could guide precision spraying, optimize agrochemical use, and reduce environmental drift.
- 1 January 2026
- Published by MDPI AG in Agriengineering
- Vol. 8 (1) , 3
Open AccessMethodological Advancement in Resistive-Based, Real-Time Spray Deposition Assessment with Multiplexed Acquisition
The use of agrochemicals remains indispensable for ensuring fruit production; however, their excessive or inefficient application poses significant environmental and health concerns. Rapid detection of spray deposition is crucial for assessing sprayer performance, improving precision application, and reducing drift and chemical waste. In this context, real-time monitoring technologies represent a promising tool to promote sustainable and efficient crop protection practices. This study refines previous experiences with an array of resistive sensors to quickly measure spray deposition. First, a multi-point calibration curve is introduced to improve the sensors’ accuracy. Furthermore, a multiplexed acquisition system (Sciospec ISX-5) is employed to enable time-resolved measurements of the whole sensor array. The method is validated by spectrophotometry and weight measurements. Wind tunnel trials with fluorescein (FLU) and fluorescein + potassium chloride (FLU + KCl) tracing solutions were conducted. The conductivity of the latter was higher than the former, without biasing the measurement. Both tracers showed good correlation between deposition and conductivity (R2 = 0.997 for FLU and 0.995 for FLU + KCl), and the maximum deviation from the spectrophotometric estimates was <10%. Time-resolved measurement showed the build-up of deposition over time, potentially indicating the dimensional composition of the sprayed cloud. The improved workflow provides array-wide, sequential deposition measurements, enabling faster on-site acquisition and efficient analysis. The results demonstrate strong potential for scaling the method to field applications, supporting its further development into real-time deposition mapping tools that could guide precision spraying, optimize agrochemical use, and reduce environmental drift.
- Open Access
- 6 May 2025
- Published by MDPI AG in Agriengineering
- Vol. 7 (5) , 139
Methodological Advancements in Testing Agricultural Nozzles and Handling of Drop Size Distribution Data
Plant protection products are necessary to guarantee food security, but their drift into the environment, usually in the form of aerosol, poses a threat to the health of bystanders and surrounding ecosystems. Appropriate testing of plant protection equipment and of its possible configurations is key to reducing drift while guaranteeing treatment efficacy. A key role in drift generation and treatment quality is played by the drop size distribution (DSD) of the employed spray nozzles. The DSD of nozzles can and should be tested before being employed by various methods. This paper recounts the recent experience in testing the DSD generated by two types of agricultural nozzles by an Oxford Lasers N60V Particle/Droplet Image Analysis (PDIA) system. The analyses put in place aimed at identifying the optimal instrument settings and adapting the methodology to the relevant ISO 25358:2018 standard. The cumulated DSD of the two nozzle types have then been fitted with a logistic function, with the aim to obtain nozzle performance models. The fitting has proven highly reliable, with correlation coefficients . These models are a satisfactory starting point to compare the performance of different PPEs. In perspective, the fitted nozzle models can help bridge the mathematical gap with other aspects of PPE performance, such as aerosol generation and downwind transport.- 6 May 2025
- Published by MDPI AG in Agriengineering
- Vol. 7 (5) , 139
Open AccessMethodological Advancements in Testing Agricultural Nozzles and Handling of Drop Size Distribution Data
Plant protection products are necessary to guarantee food security, but their drift into the environment, usually in the form of aerosol, poses a threat to the health of bystanders and surrounding ecosystems. Appropriate testing of plant protection equipment and of its possible configurations is key to reducing drift while guaranteeing treatment efficacy. A key role in drift generation and treatment quality is played by the drop size distribution (DSD) of the employed spray nozzles. The DSD of nozzles can and should be tested before being employed by various methods. This paper recounts the recent experience in testing the DSD generated by two types of agricultural nozzles by an Oxford Lasers N60V Particle/Droplet Image Analysis (PDIA) system. The analyses put in place aimed at identifying the optimal instrument settings and adapting the methodology to the relevant ISO 25358:2018 standard. The cumulated DSD of the two nozzle types have then been fitted with a logistic function, with the aim to obtain nozzle performance models. The fitting has proven highly reliable, with correlation coefficients . These models are a satisfactory starting point to compare the performance of different PPEs. In perspective, the fitted nozzle models can help bridge the mathematical gap with other aspects of PPE performance, such as aerosol generation and downwind transport. - 13 April 2025
- Published by Springer Nature
- p. 697-704
First Experiences in Data Handling to Characterise Air Distribution from Airblast Sprayers
- 13 April 2025
- Published by Springer Nature
- p. 697-704
First Experiences in Data Handling to Characterise Air Distribution from Airblast Sprayers
- 13 April 2025
- Published by Springer Nature
- p. 841-849
Efficiency and Environmental Impact of Tractors Used in Specialized Crops of Autonomous Province of Bolzano
- 13 April 2025
- Published by Springer Nature
- p. 841-849
Efficiency and Environmental Impact of Tractors Used in Specialized Crops of Autonomous Province of Bolzano
- 13 April 2025
- Published by Springer Nature
- p. 405-413
Rollover Stability Performance Tests of Tractors Commonly Used in Mountain Agroforestry Operations
- 13 April 2025
- Published by Springer Nature
- p. 405-413
Rollover Stability Performance Tests of Tractors Commonly Used in Mountain Agroforestry Operations
- 13 April 2025
- Published by Springer Nature
- p. 807-815
Mechanisation of Mountain Farming. Observations on Grain Production in the Alps
- 13 April 2025
- Published by Springer Nature
- p. 807-815
Mechanisation of Mountain Farming. Observations on Grain Production in the Alps
- Open Access
- 18 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on AgriFood Electronics
- Vol. 3 (1) , 18-25
Advancements in the Development of Resistive-Based Method Applied to Optical Tracers for Real-Time Estimation of Spray Drift Deposition
The assessment of pesticide deposition is of key importance for the prevention of off-target area contamination, as well as to ensure the efficiency of the pesticide application. It is required by regulatory authorities also to quantify the drift potential of every possible sprayer configuration. As a matter of fact, the standard methodologies to compare sprayers' functional performance require large amounts of time, and the results are not always repeatable, due to the multitude of uncontrollable variables. This study proposes and tests an innovative approach in a laboratory wind tunnel based on resistive-based measurements applied to fluorescent tracers to address this challenge effectively. Our method utilizes screen-printed electrodes integrated into the material collector for measurement of the deposited material in real time shortly after the spray application. The estimation of the material by the standard optical method was also done along with the resistive-based method and compared with the measured weight used as a benchmark reference. Our experimental results demonstrated that both the optical and the resistive-based methods overestimated the amount of deposited material compared to weight measurement, but the overall estimation error remained below $\text{2.5} \,\text{g}$ . The measurements also showed that 90% of material deposition occurred at approximately $\text{11.5} \,\text{m}$ , providing valuable insights into the spatial distribution of sprayed materials. This real-time assessment leveraging resistive measurement techniques offers substantial benefits for laboratory testing of spraying machines and has also the potential for in-field resource management and monitoring. Despite the promising potential for real-time estimation of spray drift deposition, further research and testing are required to improve the method.
- 18 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on AgriFood Electronics
- Vol. 3 (1) , 18-25
Open AccessAdvancements in the Development of Resistive-Based Method Applied to Optical Tracers for Real-Time Estimation of Spray Drift Deposition
The assessment of pesticide deposition is of key importance for the prevention of off-target area contamination, as well as to ensure the efficiency of the pesticide application. It is required by regulatory authorities also to quantify the drift potential of every possible sprayer configuration. As a matter of fact, the standard methodologies to compare sprayers' functional performance require large amounts of time, and the results are not always repeatable, due to the multitude of uncontrollable variables. This study proposes and tests an innovative approach in a laboratory wind tunnel based on resistive-based measurements applied to fluorescent tracers to address this challenge effectively. Our method utilizes screen-printed electrodes integrated into the material collector for measurement of the deposited material in real time shortly after the spray application. The estimation of the material by the standard optical method was also done along with the resistive-based method and compared with the measured weight used as a benchmark reference. Our experimental results demonstrated that both the optical and the resistive-based methods overestimated the amount of deposited material compared to weight measurement, but the overall estimation error remained below $\text{2.5} \,\text{g}$ . The measurements also showed that 90% of material deposition occurred at approximately $\text{11.5} \,\text{m}$ , providing valuable insights into the spatial distribution of sprayed materials. This real-time assessment leveraging resistive measurement techniques offers substantial benefits for laboratory testing of spraying machines and has also the potential for in-field resource management and monitoring. Despite the promising potential for real-time estimation of spray drift deposition, further research and testing are required to improve the method.
- 1 September 2024
- Published by Springer Nature
- p. 153-163
Experimental Validation of the Influence of Obstacles on Tractor Rollover Stability
- 1 September 2024
- Published by Springer Nature
- p. 153-163
Experimental Validation of the Influence of Obstacles on Tractor Rollover Stability
- 18 June 2024
- Published by Springer Nature in Aerotecnica Missili & Spazio
- Vol. 104 (3) , 213-222
Characterization of the Spray System of the TerraXcube Icing Wind Tunnel
- 18 June 2024
- Published by Springer Nature in Aerotecnica Missili & Spazio
- Vol. 104 (3) , 213-222
Characterization of the Spray System of the TerraXcube Icing Wind Tunnel