Agurne Uribarri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Agurne Uribarri has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Asier Eguia
University Institute for Regenerative Medicine and Oral Implantology—UIRMI (UPV/EHU-Fundación Eduardo Anitua), 01007 Vitoria, Spain
5 shared publications - Fernando Verdugo
VA Hospital, Greater Los Angeles Healthcare System, Los Angeles, CA, USA
3 shared publications Antonio D'Addona
Odontology Clinic, Catholic University Sacro Cuore, Rome, Italy
2 shared publicationsFernando Verdugo
Department of Periodontics, VA Hospital, Greater Los Angeles Healthcare, Los Angeles, California
2 shared publications- Fernando Verdugo
Department of Periodontics, VA Hospital, Greater Los Angeles Healthcare System, California, USA; Catholic University Sacro Cuore, Rome, Italy
2 shared publications J. López Vicente
2 shared publications
Latest Publications
- 27 August 2019
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 21 (5) , 1062-1072
Marginal and internal fit of CAD/CAM frameworks in multiple implant‐supported restorations: Scanning and milling error analysis
Background: Despite computer‐aided design and computer‐aided manufacturing (CAD/CAM) technology improving prosthesis fit, errors inherent to digital workflow still exist.Purpose: To measure scanning/milling errors, and identify factors influencing marginal (MD) and internal discrepancy (ID).Materials and Methods: After scanning, 22 conical abutments in 5 master casts, 6 suprastructures with more than 2 implants (3, 4, and 6) were CAD designed. Angular deviation and errors in the vertical/horizontal planes were analyzed using a coordinate measuring machine (CMM). CAD suprastructures were milled and MD/ID evaluated with micro‐computed tomography (CT) and optic microscopy (OM) at one screw test (OST) and final fit test (FFT).Results: Mean scanning errors, at the vertical/horizontal planes, and angulation error were 3 μm ± 13, 44 μm ± 34, 0.3° ± 0.2°, respectively. Angulation errors nearly double in structures >3 abutments (0.26°vs 0.4°). OM MD in FFT/OST was 57.7 μm ± 13.9/100.7 μm ± 34.6, respectively. Micro‐CT FFT‐MD was 38.9 μm ± 12.8. Lineal/perimetral ID was 49.6 μm ± 11.9 and 108.2° ± 41.8, respectively. Structures >3‐implants were 2.3 times more likely to present higher MD (CI95%:0.4‐13.6). Nearly all the internal horizontal gap was due to scanning errors (44 of 49.6 μm). Horizontal scanning errors were three times more likely to present greater ID (CI95%:0.5‐17.4).Conclusion: Horizontal plane scanning errors are greater than vertical errors. Scanning angulation/milling errors are higher for suprastructures>3implants. Scanning/milling errors are associated with ID/MD, respectively, leading to micro‐gap formation. A CMM reduces scanning errors in >3‐implant‐frameworks before milling the final piece.
- 27 August 2019
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 21 (5) , 1062-1072
Marginal and internal fit of CAD/CAM frameworks in multiple implant‐supported restorations: Scanning and milling error analysis
Background: Despite computer‐aided design and computer‐aided manufacturing (CAD/CAM) technology improving prosthesis fit, errors inherent to digital workflow still exist.Purpose: To measure scanning/milling errors, and identify factors influencing marginal (MD) and internal discrepancy (ID).Materials and Methods: After scanning, 22 conical abutments in 5 master casts, 6 suprastructures with more than 2 implants (3, 4, and 6) were CAD designed. Angular deviation and errors in the vertical/horizontal planes were analyzed using a coordinate measuring machine (CMM). CAD suprastructures were milled and MD/ID evaluated with micro‐computed tomography (CT) and optic microscopy (OM) at one screw test (OST) and final fit test (FFT).Results: Mean scanning errors, at the vertical/horizontal planes, and angulation error were 3 μm ± 13, 44 μm ± 34, 0.3° ± 0.2°, respectively. Angulation errors nearly double in structures >3 abutments (0.26°vs 0.4°). OM MD in FFT/OST was 57.7 μm ± 13.9/100.7 μm ± 34.6, respectively. Micro‐CT FFT‐MD was 38.9 μm ± 12.8. Lineal/perimetral ID was 49.6 μm ± 11.9 and 108.2° ± 41.8, respectively. Structures >3‐implants were 2.3 times more likely to present higher MD (CI95%:0.4‐13.6). Nearly all the internal horizontal gap was due to scanning errors (44 of 49.6 μm). Horizontal scanning errors were three times more likely to present greater ID (CI95%:0.5‐17.4).Conclusion: Horizontal plane scanning errors are greater than vertical errors. Scanning angulation/milling errors are higher for suprastructures>3implants. Scanning/milling errors are associated with ID/MD, respectively, leading to micro‐gap formation. A CMM reduces scanning errors in >3‐implant‐frameworks before milling the final piece.
- 21 September 2017
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 19 (6) , 1054-1060
Long‐term stable vertical bone regeneration after sinus floor elevation and simultaneous implant placement with and without grafting
Background: Less invasive surgical approaches to regenerate bone intra‐sinus and allow long‐term functional implant stability are needed.Purpose: To evaluate long‐term vertical bone regeneration after sinus floor elevation and simultaneous implant placement with and without bone grafting.Methods: Vertical bone gains (VBG) post‐sinus elevation, with and without grafting, were evaluated in thirty individuals presenting an average residual bone height (RBH) of 4.2 mm using a standardized digital technique. Measurements were taken preoperatively, and at an average of 64.6 months follow‐up. Clinically, peri‐implant tissues were assessed for pocket formation and presence of inflammation to evaluate established success criteria.Results: Overall, RBH averaged 4.2 ± 1.1 mm (range: 1.8‐5.8) and VBG 7.7 ± 1.6 mm (range: 6.0‐12.9). Mean difference of 7.6 mm between vertical bone heights (VBH) at augmented implants sites and initial RBH, 11.8 versus 4.2 mm, (P < .0001, CI95%: 6.9‐8.2) was statistically significant. RBH averaged 4.5 ± 0.8 mm and 3.8 ± 1.2 (P = .07) and VBG 6.8 ± 0.5 and 8.5 ± 1.9 mm (P = .003, CI95%: 0.6‐2.7), for nongrafted and grafted individuals, respectively. The grafting group received an average graft volume of 0.35 ± 0.1 cc (range: 0.25‐0.5) per implant site. Long‐term follow‐ups average 64.6 months (range: 36‐144) and all implants met the success criteria. VBG ≥ 7 mm were 7.3 times more likely to develop on grafted sites (OR = 7.3, P = 0.02, CI95%: 1.2‐46.2).Conclusion: None to negligible amounts of grafting material are required to regenerate substantial amounts of autogenous bone into atrophic sinus cavities after simultaneous implant placement. The regenerated VBH seems stable for functional implant stability long‐term. Implant success rates were 100% at an average of 64.6 months.
- 21 September 2017
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 19 (6) , 1054-1060
Long‐term stable vertical bone regeneration after sinus floor elevation and simultaneous implant placement with and without grafting
Background: Less invasive surgical approaches to regenerate bone intra‐sinus and allow long‐term functional implant stability are needed.Purpose: To evaluate long‐term vertical bone regeneration after sinus floor elevation and simultaneous implant placement with and without bone grafting.Methods: Vertical bone gains (VBG) post‐sinus elevation, with and without grafting, were evaluated in thirty individuals presenting an average residual bone height (RBH) of 4.2 mm using a standardized digital technique. Measurements were taken preoperatively, and at an average of 64.6 months follow‐up. Clinically, peri‐implant tissues were assessed for pocket formation and presence of inflammation to evaluate established success criteria.Results: Overall, RBH averaged 4.2 ± 1.1 mm (range: 1.8‐5.8) and VBG 7.7 ± 1.6 mm (range: 6.0‐12.9). Mean difference of 7.6 mm between vertical bone heights (VBH) at augmented implants sites and initial RBH, 11.8 versus 4.2 mm, (P < .0001, CI95%: 6.9‐8.2) was statistically significant. RBH averaged 4.5 ± 0.8 mm and 3.8 ± 1.2 (P = .07) and VBG 6.8 ± 0.5 and 8.5 ± 1.9 mm (P = .003, CI95%: 0.6‐2.7), for nongrafted and grafted individuals, respectively. The grafting group received an average graft volume of 0.35 ± 0.1 cc (range: 0.25‐0.5) per implant site. Long‐term follow‐ups average 64.6 months (range: 36‐144) and all implants met the success criteria. VBG ≥ 7 mm were 7.3 times more likely to develop on grafted sites (OR = 7.3, P = 0.02, CI95%: 1.2‐46.2).Conclusion: None to negligible amounts of grafting material are required to regenerate substantial amounts of autogenous bone into atrophic sinus cavities after simultaneous implant placement. The regenerated VBH seems stable for functional implant stability long‐term. Implant success rates were 100% at an average of 64.6 months.
- 10 February 2017
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 19 (3) , 478-485
Autogenous bone block grafting provides facial implant tissue stability long‐term
Background: Mucosal recession (MR) and bone loss can compromise anterior implant esthetics.Purpose: To evaluate tissue stability and clinical outcomes of anterior implants augmented with autogenous block transplants long‐term.Materials and Methods: This prospective cross‐sectional clinical study analyzed facial tissue recession of anterior implants augmented with autogenous bone blocks and compared them to adjacent teeth in forty patients 52 months post‐augmentation. Clinical parameters, MR and implant transparency, were assessed at delivery and follow‐up. The hypothesis is that the facial mucosa of augmented implant sites is more resistant to trauma than the gingival margins of adjacent teeth.Results: Teeth were seven times more likely to present a facial recession than adjacent augmented implants at 52‐month follow‐up (RR: 7; P < .001; 95%CI: 2.7‐18.0). Augmented implant sites were six times more likely to present “no‐tissue‐recession” than adjacent teeth (RR: 6.2; P < .001; 95%CI: 2.4‐15.7). Mean tooth facial tissue recession was significantly higher than adjacent implants, 1.18 ± 1.05 mm (range: 0‐3.5 mm) vs. 0.06 ± 0.2 mm (95%CI: 0.8‐1.5; P < .0001). Thick biotype teeth were 2 times more resistant to recession than thin biotype teeth (RR: 2.03; P = .03; 95%CI: 1.2‐3.5). Implant success rates were 100%. Lack of transparency and MR at facial implant sites lasted an average of 52 months and up to 144 without signs of inflammation or pocket formation regardless of the individual's biotype. Facial bone thicknesses of 2.2 mm seem optimal for tissue stability.Conclusions: Autogenous bone block augmentation with staged implant placement seems to be a predictable, short‐healing, reconstructive protocol in the esthetic zone maintaining stable peri‐implant tissues long‐term. Implant augmented sites seem more resistant to develop a recession than adjacent teeth.
- 10 February 2017
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 19 (3) , 478-485
Autogenous bone block grafting provides facial implant tissue stability long‐term
Background: Mucosal recession (MR) and bone loss can compromise anterior implant esthetics.Purpose: To evaluate tissue stability and clinical outcomes of anterior implants augmented with autogenous block transplants long‐term.Materials and Methods: This prospective cross‐sectional clinical study analyzed facial tissue recession of anterior implants augmented with autogenous bone blocks and compared them to adjacent teeth in forty patients 52 months post‐augmentation. Clinical parameters, MR and implant transparency, were assessed at delivery and follow‐up. The hypothesis is that the facial mucosa of augmented implant sites is more resistant to trauma than the gingival margins of adjacent teeth.Results: Teeth were seven times more likely to present a facial recession than adjacent augmented implants at 52‐month follow‐up (RR: 7; P < .001; 95%CI: 2.7‐18.0). Augmented implant sites were six times more likely to present “no‐tissue‐recession” than adjacent teeth (RR: 6.2; P < .001; 95%CI: 2.4‐15.7). Mean tooth facial tissue recession was significantly higher than adjacent implants, 1.18 ± 1.05 mm (range: 0‐3.5 mm) vs. 0.06 ± 0.2 mm (95%CI: 0.8‐1.5; P < .0001). Thick biotype teeth were 2 times more resistant to recession than thin biotype teeth (RR: 2.03; P = .03; 95%CI: 1.2‐3.5). Implant success rates were 100%. Lack of transparency and MR at facial implant sites lasted an average of 52 months and up to 144 without signs of inflammation or pocket formation regardless of the individual's biotype. Facial bone thicknesses of 2.2 mm seem optimal for tissue stability.Conclusions: Autogenous bone block augmentation with staged implant placement seems to be a predictable, short‐healing, reconstructive protocol in the esthetic zone maintaining stable peri‐implant tissues long‐term. Implant augmented sites seem more resistant to develop a recession than adjacent teeth.
- 15 September 2016
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 19 (2) , 268-279
Bone Remodeling around Implants Placed in Augmented Sinuses in Patients with and without History of Periodontitis
Susceptible individuals may be more prone to bone loss after augmentation procedures. Identify plausible clinical and biological factors influencing apical and marginal bone remodeling at implants placed in augmented sinuses, in patients with and without history of periodontitis. This prospective cross-sectional clinical study analyzed implant bone levels in a group of 104 patients with and without history of periodontitis undergoing 139 sinus augmentation procedures. Marginal and apical bone loss (MBL/ABL) was measured post-loading using a standardized digital technique. Measurements were taken preoperatively, at second stage implant uncovery, one year after loading and at an average of 53-months follow-up. Odds ratios were calculated to evaluate risks factors of contributing variables, such as, smoking, history of periodontitis, membrane perforation, surgical approach, grafting material, use of PRP, and implant design/dimensions. Patients with history of periodontitis were 8.43 times more likely to present more than 2mm of MBL than patients without it (p =.041; CI95%: 1.09–65.12). Smokers were 4.97 times more likely to present over 2 mm of MBL than non-smokers (p =.003; CI95%: 1.70–14.54). Sinus membrane perforations were 11.4 times more likely to present ABL than those without perforation (p = 0.007; CI95%: 1.94–66.93). Mean MBL/ABL after 1-year post-loading and at last control were 0.49/0.56 mm and 0.67/0.46 mm, respectively. The use of a collagen membrane to cover the antrostomy and only xenograft as grafting material decreased ABL by 0.9 mm. The combination of autologous/xenograft bone was 4.04 times more likely to present higher ABL than xenograft alone (p = 0.023; CI95%: 1.21–13.45). Overall implant survival/success rates were 94.39%/91.33%, respectively. Smoking and previous history of periodontitis negatively affects implant MBL. Sinus membrane perforation was associated with higher ABL. Lack of association between bone remodeling at marginal and apical areas suggests that they are different and independent processes.
- 15 September 2016
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 19 (2) , 268-279
Bone Remodeling around Implants Placed in Augmented Sinuses in Patients with and without History of Periodontitis
Susceptible individuals may be more prone to bone loss after augmentation procedures. Identify plausible clinical and biological factors influencing apical and marginal bone remodeling at implants placed in augmented sinuses, in patients with and without history of periodontitis. This prospective cross-sectional clinical study analyzed implant bone levels in a group of 104 patients with and without history of periodontitis undergoing 139 sinus augmentation procedures. Marginal and apical bone loss (MBL/ABL) was measured post-loading using a standardized digital technique. Measurements were taken preoperatively, at second stage implant uncovery, one year after loading and at an average of 53-months follow-up. Odds ratios were calculated to evaluate risks factors of contributing variables, such as, smoking, history of periodontitis, membrane perforation, surgical approach, grafting material, use of PRP, and implant design/dimensions. Patients with history of periodontitis were 8.43 times more likely to present more than 2mm of MBL than patients without it (p =.041; CI95%: 1.09–65.12). Smokers were 4.97 times more likely to present over 2 mm of MBL than non-smokers (p =.003; CI95%: 1.70–14.54). Sinus membrane perforations were 11.4 times more likely to present ABL than those without perforation (p = 0.007; CI95%: 1.94–66.93). Mean MBL/ABL after 1-year post-loading and at last control were 0.49/0.56 mm and 0.67/0.46 mm, respectively. The use of a collagen membrane to cover the antrostomy and only xenograft as grafting material decreased ABL by 0.9 mm. The combination of autologous/xenograft bone was 4.04 times more likely to present higher ABL than xenograft alone (p = 0.023; CI95%: 1.21–13.45). Overall implant survival/success rates were 94.39%/91.33%, respectively. Smoking and previous history of periodontitis negatively affects implant MBL. Sinus membrane perforation was associated with higher ABL. Lack of association between bone remodeling at marginal and apical areas suggests that they are different and independent processes.
- 1 April 2016
- Published by Elsevier in Archives of Oral Biology
- Vol. 64, 39-50
Systemic antibiotics and the risk of superinfection in peri-implantitis
- 1 April 2016
- Published by Elsevier in Archives of Oral Biology
- Vol. 64, 39-50
Systemic antibiotics and the risk of superinfection in peri-implantitis
- 7 May 2014
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 19 (2) , 535-543
Epstein–Barr virus associated peri-implantitis: a split-mouth study
Herpesviral–bacterial synergism may play a potential role in periodontitis and peri-implantitis (PI) etiopathogenesis. PI lesions can worsen depending on specific microbial challenge and host susceptibility. This cross-sectional split-mouth study aimed to substantiate herpesviral–bacterial co-infection in PI patients and assess associations with periodontopathogen salivary contamination. PCR-based identification was performed on 23 patients presenting PI and contralateral healthy implants, and compared to unstimulated whole saliva. Clinical evaluation included probing depths, bleeding on probing, and suppuration. Radiographs were assessed for the presence of lamina dura and bone loss. Three sample sites per patient were tested: PI lesions, healthy implant sulci, and saliva. Quantitative PCR evaluated Epstein–Barr virus (EBV) and cytomegalovirus (CMV) copy counts. Significance of group comparisons for binary-dependent variables, within-subjects designs, was determined by McNemar's chi-square test. Risk analysis was evaluated through odds ratios (OR). PI lesions were 14.2 (P = 0.001; 95 % confidence interval [CI], 1.6–124.1) and 3 times (P = 0.03; 95 % CI, 0.7–11.9) more likely to harbor EBV than healthy implants and saliva, respectively. EBV positive predictive value was 90 %. PI was associated with absence of lamina dura and higher periodontopathogen proportions. Saliva sampling showed high agreement with PI bacterial detection (89–100 % rate) but not with EBV (44.4 %). The OR of PI lesions harboring Treponema denticola or Tannerella forsythia was 6.79 (P = 0.007; 95 % CI, 1.8–25.0) and 3.3 (P < 0.0001; 95 % CI, 0.3–34.3) times higher than healthy implants, respectively. Saliva of patients with PI was 5.6 times more likely to be contaminated with Prevotella nigrescens than healthy peri-implant sulci (P = 0.002). PI lesions were 1.92 times more likely to harbor Prevotella nigrescens than healthy implants (P = 0.04). EBV is a potential candidate in peri-implantitis etiopathogenesis. Saliva PCR analysis is useful in predicting peri-implantitis-specific bacterial infection but not EBV or CMV. Herpesviral–bacterial synergism may favor ongoing microbial challenge in peri-implant disease and exacerbate its progression. EBV infection may explain non-responsive to treatment PI. Peri-implantitis individuals may benefit from antiviral therapy.
- 7 May 2014
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 19 (2) , 535-543
Epstein–Barr virus associated peri-implantitis: a split-mouth study
Herpesviral–bacterial synergism may play a potential role in periodontitis and peri-implantitis (PI) etiopathogenesis. PI lesions can worsen depending on specific microbial challenge and host susceptibility. This cross-sectional split-mouth study aimed to substantiate herpesviral–bacterial co-infection in PI patients and assess associations with periodontopathogen salivary contamination. PCR-based identification was performed on 23 patients presenting PI and contralateral healthy implants, and compared to unstimulated whole saliva. Clinical evaluation included probing depths, bleeding on probing, and suppuration. Radiographs were assessed for the presence of lamina dura and bone loss. Three sample sites per patient were tested: PI lesions, healthy implant sulci, and saliva. Quantitative PCR evaluated Epstein–Barr virus (EBV) and cytomegalovirus (CMV) copy counts. Significance of group comparisons for binary-dependent variables, within-subjects designs, was determined by McNemar's chi-square test. Risk analysis was evaluated through odds ratios (OR). PI lesions were 14.2 (P = 0.001; 95 % confidence interval [CI], 1.6–124.1) and 3 times (P = 0.03; 95 % CI, 0.7–11.9) more likely to harbor EBV than healthy implants and saliva, respectively. EBV positive predictive value was 90 %. PI was associated with absence of lamina dura and higher periodontopathogen proportions. Saliva sampling showed high agreement with PI bacterial detection (89–100 % rate) but not with EBV (44.4 %). The OR of PI lesions harboring Treponema denticola or Tannerella forsythia was 6.79 (P = 0.007; 95 % CI, 1.8–25.0) and 3.3 (P < 0.0001; 95 % CI, 0.3–34.3) times higher than healthy implants, respectively. Saliva of patients with PI was 5.6 times more likely to be contaminated with Prevotella nigrescens than healthy peri-implant sulci (P = 0.002). PI lesions were 1.92 times more likely to harbor Prevotella nigrescens than healthy implants (P = 0.04). EBV is a potential candidate in peri-implantitis etiopathogenesis. Saliva PCR analysis is useful in predicting peri-implantitis-specific bacterial infection but not EBV or CMV. Herpesviral–bacterial synergism may favor ongoing microbial challenge in peri-implant disease and exacerbate its progression. EBV infection may explain non-responsive to treatment PI. Peri-implantitis individuals may benefit from antiviral therapy.
- 1 January 2014
- Published by Springer Nature
- p. 131-138
Collision Free Design of Dental Prosthesis
- Open Access
- 1 January 2013
- Published by Medicina Oral, S.L. in Medicina Oral Patología Oral y Cirugia Bucal
- Vol. 18 (2) , e207-e211
Salivary cortisol determination in patients from the basque country with recurrent aphthous stomatitis. A pilot study
Objectives: Stress and anxiety are controversial factors involved in the complex pathogenesis of Recurrent Aphthous Stomatitis (RAS). The determination of salivary cortisol is a useful, simple and safe test to detect states of high stress or anxiety. The aim of this study is to check for changes in salivary cortisol levels in patients with RAS during periods of active disease. Study design: A measurement of cortisol employing Enzyme-Linked Immuno Sorbent Assay (ELISA) was carried out in samples of unstimulated saliva from 20 patients with active lesions of RAS and 10 healthy individuals used as controls. Results: Increased levels of salivary cortisol were detected in 3 cases, all of them within the group of patients with RAS. In none of the control group patients the level of salivary cortisol was increased. The mean level of salivary cortisol was 0.64 mg / dl (range 0.2 to 1.62) for patients with RAS and 0.57 mg / dl (range 0.25 to 1.09) for controls. Conclusion: Salivary cortisol levels are not statistically higher in patients with active lesions of RAS.
- 1 January 2013
- Published by Medicina Oral, S.L. in Medicina Oral Patología Oral y Cirugia Bucal
- Vol. 18 (2) , e207-e211
Open AccessSalivary cortisol determination in patients from the basque country with recurrent aphthous stomatitis. A pilot study
Objectives: Stress and anxiety are controversial factors involved in the complex pathogenesis of Recurrent Aphthous Stomatitis (RAS). The determination of salivary cortisol is a useful, simple and safe test to detect states of high stress or anxiety. The aim of this study is to check for changes in salivary cortisol levels in patients with RAS during periods of active disease. Study design: A measurement of cortisol employing Enzyme-Linked Immuno Sorbent Assay (ELISA) was carried out in samples of unstimulated saliva from 20 patients with active lesions of RAS and 10 healthy individuals used as controls. Results: Increased levels of salivary cortisol were detected in 3 cases, all of them within the group of patients with RAS. In none of the control group patients the level of salivary cortisol was increased. The mean level of salivary cortisol was 0.64 mg / dl (range 0.2 to 1.62) for patients with RAS and 0.57 mg / dl (range 0.25 to 1.09) for controls. Conclusion: Salivary cortisol levels are not statistically higher in patients with active lesions of RAS.
- Open Access
- 1 October 2011
- Published by SciELO Espana/Repisalud in Avances En Odontoestomatologia
- Vol. 27 (5) , 241-244
Hiperplasia coronoidea bilateral: Una rara patología causante de disfunción temporomandibular
- 1 October 2011
- Published by SciELO Espana/Repisalud in Avances En Odontoestomatologia
- Vol. 27 (5) , 241-244
Open AccessHiperplasia coronoidea bilateral: Una rara patología causante de disfunción temporomandibular
- 1 June 2011
- Published by Wiley in Journal of Periodontology
- Vol. 82 (6) , 863-871
Bone Microbial Decontamination Agents in Osseous Grafting: An In Vitro Study With Fresh Human Explants
Background: Establishing a safe prophylactic antimicrobial protocol in bone grafting may enhance osseous volume outcomes. The purpose of this in vitro study is to assess human osteoblast response and safety after explant antimicrobial exposure.Methods: Fresh human bone explants were exposed to three antimicrobials: povidone‐iodine (PovI; 0.05%, 1%, and 5%), chlorhexidine (CHX; 0.2% and 1%), and sodium hypochlorite (NaOCl; 2.5%, 4.5%, and 5.25%) at different times (15, 30, 45, and 60 seconds) and concentrations to assess cellular toxicity. Explants were washed three times with saline after exposure. Controls, explants cultured in the absence of antimicrobials, were performed for all experimental situations tested. Trials were conducted in triplicate. Particle size influence on osteoblast growth was determined between bone fragments with a diameter Results: Osteoblast growth was similar for particles 0.05). Light microscopy showed on average 97% osteoblastic growth for bone particles exposed to PovI 5% and CHX 0.2% for all times and CHX 1% up to 30 seconds. The odds ratio of positive osteoblastic growth after a 30‐second 2.5% NaOCl exposure was 2.4 times higher than after 5.25%. On average, one of two replicas yielded positive growth with 2.5% NaOCl and one of three with 5.25%. After 60‐second explant exposure, positive osteoblastic growth was 7.7 times more likely to occur with 5% PovI or 0.2% CHX than with 5.25% NaOCl (P Conclusions: Best osteoblastic growth occurred after bone PovI exposure and CHX 0.2%. Cellular toxicity seems to be influenced by the type of antimicrobial, concentration, and exposure time. SEM analysis confirmed absence of osteoblast phenotypic alterations after exposure. Decontamination agents can safely be used in bone transplantation using up to 5% PovI and 0.2% CHX for 1 minute and CHX 1% for 30 seconds.
- 1 June 2011
- Published by Wiley in Journal of Periodontology
- Vol. 82 (6) , 863-871
Bone Microbial Decontamination Agents in Osseous Grafting: An In Vitro Study With Fresh Human Explants
Background: Establishing a safe prophylactic antimicrobial protocol in bone grafting may enhance osseous volume outcomes. The purpose of this in vitro study is to assess human osteoblast response and safety after explant antimicrobial exposure.Methods: Fresh human bone explants were exposed to three antimicrobials: povidone‐iodine (PovI; 0.05%, 1%, and 5%), chlorhexidine (CHX; 0.2% and 1%), and sodium hypochlorite (NaOCl; 2.5%, 4.5%, and 5.25%) at different times (15, 30, 45, and 60 seconds) and concentrations to assess cellular toxicity. Explants were washed three times with saline after exposure. Controls, explants cultured in the absence of antimicrobials, were performed for all experimental situations tested. Trials were conducted in triplicate. Particle size influence on osteoblast growth was determined between bone fragments with a diameter Results: Osteoblast growth was similar for particles 0.05). Light microscopy showed on average 97% osteoblastic growth for bone particles exposed to PovI 5% and CHX 0.2% for all times and CHX 1% up to 30 seconds. The odds ratio of positive osteoblastic growth after a 30‐second 2.5% NaOCl exposure was 2.4 times higher than after 5.25%. On average, one of two replicas yielded positive growth with 2.5% NaOCl and one of three with 5.25%. After 60‐second explant exposure, positive osteoblastic growth was 7.7 times more likely to occur with 5% PovI or 0.2% CHX than with 5.25% NaOCl (P Conclusions: Best osteoblastic growth occurred after bone PovI exposure and CHX 0.2%. Cellular toxicity seems to be influenced by the type of antimicrobial, concentration, and exposure time. SEM analysis confirmed absence of osteoblast phenotypic alterations after exposure. Decontamination agents can safely be used in bone transplantation using up to 5% PovI and 0.2% CHX for 1 minute and CHX 1% for 30 seconds.