Antonio Altana
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Antonio Altana has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Luisa Petti
Faculty of Engineering, Free University of Bozen-Bolzano, Bozen-Bolzano 39100, Italy
14 shared publications - Paolo Lugli
Faculty of Engineering, Free University of Bozen-Bolzano, Bozen-Bolzano 39100, Italy
14 shared publications - Pietro Ibba
Faculty of Engineering, Free University of Bozen-Bolzano, Bolzano, Italy
8 shared publications - Bajramshahe Shkodra
Institute of Physics & Research Center SENS Faculty of Electric Power Systems and Information Technology University of the Bundeswehr Munich Neubiberg Germany
6 shared publications - Mattia Petrelli
Sensing Technologies Laboratory (STL), Faculty of Engineering, Free University of Bozen- Bolzano, Bozen, 39100, Italy
5 shared publications - Moritz Ploner
Sensing Technologies Laboratory (STL), Faculty of Engineering, Free University of BozenBolzano, Bolzano, Italy
5 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on AgriFood Electronics
- Vol. 4 (2) , 710-719
Greenhouse Evaluation of Printed Paper-Based Sensors for Leaf-Level Humidity Monitoring in Tomato Leaves
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on AgriFood Electronics
- Vol. 4 (2) , 710-719
Open AccessGreenhouse Evaluation of Printed Paper-Based Sensors for Leaf-Level Humidity Monitoring in Tomato Leaves
- 3 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal on Flexible Electronics
- Vol. 5 (1) , 3-13
Enhancing Screen-Printed Electrode Performance Through Simulation-Driven Design Optimization for Wearable Applications
Wearable biosensors are transforming remote health monitoring with non-invasive sweat biomarker detection. Nevertheless, achieving reliable sensing requires miniaturized, flexible platforms capable of detecting, with ultra-high sensitivity, biomarker levels down to pg/mL. Electrochemical platforms, especially those using three-electrode platforms, hold significant promise but require careful geometric optimization to meet these needs. To address this, we evaluated four geometric layouts of screen-printed carbon three-electrode platforms on flexible polyethylene terephthalate (PET) substrates. Our investigation comprises experimental evaluations by means of cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), supported by simulations through a novel 3D COMSOL Multiphysics® model. The results reveal that a fourfold increase in the active area leads to a twofold increase in the CV peak currents, while reduced electrode spacing enhances current density and minimizes diffusion effects. Comparisons of experimental and simulated CV currents show that larger areas may be more prone to surface disuniformities, making performance more dependent on material properties than on area optimization. The EIS analysis reveals that a fourfold increase in the active area reduces charge transfer resistance (RCT) by 45%, while doubling the electrode distance results in a 29% increase in RCT, indicating inefficient charge transfer due to weakened electric fields and reduced charge carrier concentration. Our findings highlight the need for compact designs and simulation-guided geometric optimization for enhanced performance.
- 3 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal on Flexible Electronics
- Vol. 5 (1) , 3-13
Enhancing Screen-Printed Electrode Performance Through Simulation-Driven Design Optimization for Wearable Applications
Wearable biosensors are transforming remote health monitoring with non-invasive sweat biomarker detection. Nevertheless, achieving reliable sensing requires miniaturized, flexible platforms capable of detecting, with ultra-high sensitivity, biomarker levels down to pg/mL. Electrochemical platforms, especially those using three-electrode platforms, hold significant promise but require careful geometric optimization to meet these needs. To address this, we evaluated four geometric layouts of screen-printed carbon three-electrode platforms on flexible polyethylene terephthalate (PET) substrates. Our investigation comprises experimental evaluations by means of cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), supported by simulations through a novel 3D COMSOL Multiphysics® model. The results reveal that a fourfold increase in the active area leads to a twofold increase in the CV peak currents, while reduced electrode spacing enhances current density and minimizes diffusion effects. Comparisons of experimental and simulated CV currents show that larger areas may be more prone to surface disuniformities, making performance more dependent on material properties than on area optimization. The EIS analysis reveals that a fourfold increase in the active area reduces charge transfer resistance (RCT) by 45%, while doubling the electrode distance results in a 29% increase in RCT, indicating inefficient charge transfer due to weakened electric fields and reduced charge carrier concentration. Our findings highlight the need for compact designs and simulation-guided geometric optimization for enhanced performance.
- 14 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on AgriFood Electronics
- Vol. PP, 1-8
Modular Impedimetric Sensing Platform for Laboratory and Field Characterization in Precision Agriculture
Precision horticulture demands affordable and versatile platforms to test a variety of sensors. However, current solutions are often costly, complex, and limited in scope, hindering widespread adoption. Here, we present a modular and practical sensor system designed for the integration and evaluation of printed impedimetric sensors. The platform includes an impedance analyzer, two 16-channel multiplexers, and a Raspberry Pi. Using the developed data acquisition system, we fully characterized the electrical impedance spectroscopy response of an ammonia gas sensor and three humidity sensors over a frequency range from 500 Hz to 10 MHz. The chemiresistive ammonia sensor, tested in a controlled laboratory environment using a gas exposure setup, showed optimal operation at 4 kHz, demonstrating high sensitivity in impedance magnitude measurements. In contrast, the paper-based humidity sensors were evaluated directly on plants under field conditions, where analysis of phase angle ($\Theta$) and impedance magnitude ($\Omega$) identified optimal measurement points. At lower frequencies (below $10^{4}$ Hz), both parameters showed strong correlations with relative humidity, with correlation coefficients of $0.52 \pm 0.03$ and $-0.54 \pm 0.02$, respectively. These results indicate a capacitive response to moisture absorption and good reproducibility between devices. Beyond $10^{5}$ Hz, the correlation weakened, indicating a transition in sensor response mechanisms. Our results demonstrate the effectiveness of the platform in both laboratory and field environments, providing a robust and cost-effective tool to evaluate impedimetric sensors. By enabling rapid and accurate assessments, this system advances agricultural technology for more efficient, sustainable precision horticulture.
- 14 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on AgriFood Electronics
- Vol. PP, 1-8
Modular Impedimetric Sensing Platform for Laboratory and Field Characterization in Precision Agriculture
Precision horticulture demands affordable and versatile platforms to test a variety of sensors. However, current solutions are often costly, complex, and limited in scope, hindering widespread adoption. Here, we present a modular and practical sensor system designed for the integration and evaluation of printed impedimetric sensors. The platform includes an impedance analyzer, two 16-channel multiplexers, and a Raspberry Pi. Using the developed data acquisition system, we fully characterized the electrical impedance spectroscopy response of an ammonia gas sensor and three humidity sensors over a frequency range from 500 Hz to 10 MHz. The chemiresistive ammonia sensor, tested in a controlled laboratory environment using a gas exposure setup, showed optimal operation at 4 kHz, demonstrating high sensitivity in impedance magnitude measurements. In contrast, the paper-based humidity sensors were evaluated directly on plants under field conditions, where analysis of phase angle ($\Theta$) and impedance magnitude ($\Omega$) identified optimal measurement points. At lower frequencies (below $10^{4}$ Hz), both parameters showed strong correlations with relative humidity, with correlation coefficients of $0.52 \pm 0.03$ and $-0.54 \pm 0.02$, respectively. These results indicate a capacitive response to moisture absorption and good reproducibility between devices. Beyond $10^{5}$ Hz, the correlation weakened, indicating a transition in sensor response mechanisms. Our results demonstrate the effectiveness of the platform in both laboratory and field environments, providing a robust and cost-effective tool to evaluate impedimetric sensors. By enabling rapid and accurate assessments, this system advances agricultural technology for more efficient, sustainable precision horticulture.
- Open Access
- 26 June 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 287, 117734
Flexible microfluidics-integrated electrochemical system for detection of tumor necrosis factor-alpha under continuous flow of sweat
- 26 June 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 287, 117734
Open AccessFlexible microfluidics-integrated electrochemical system for detection of tumor necrosis factor-alpha under continuous flow of sweat
- 17 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (5) , 7954-7961
Flexible Memristive Biosensors for Sensitive Detection of Prostate-Specific Antigen in Biological Environments
In this work, we developed flexible polymer-based memristive-like devices specifically designed for biosensing applications. The fabricated devices consist of two gold electrodes connected by a biocompatible polymeric resistive layer made of poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate) (PEDOT:PSS) and poly(vinyl alcohol) (PVA), on flexible polyimide substrate. To demonstrate the applicability of this novel sensing approach for critical diagnostic applications, we explored the current-voltage (I-V) hysteretic properties for the detection of prostate-specific antigen (PSA). To ensure sensitivity, we harnessed the adhesive properties of 3-glycidyloxypropyl trimethoxysilane (GOPS), to coat the surface of PEDOT:PSS-PVA and then grafted anti-PSA antibodies covalently in the polymeric channel. The layer-by-layer assembly was monitored using electrochemical and current-voltage memristive-like measurements. The specific anti-PSA antibodies assembled on the memristive-like channel enabled PSA detection in undiluted high ionic strength solutions within concentration ranging from 0.005 to 50 ng/ml. Our thin-film organic memristive-like devices show promise as cost-effective building blocks for memristive-like biosensing of PSA at clinically relevant levels (ng/ml).
- 17 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (5) , 7954-7961
Flexible Memristive Biosensors for Sensitive Detection of Prostate-Specific Antigen in Biological Environments
In this work, we developed flexible polymer-based memristive-like devices specifically designed for biosensing applications. The fabricated devices consist of two gold electrodes connected by a biocompatible polymeric resistive layer made of poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate) (PEDOT:PSS) and poly(vinyl alcohol) (PVA), on flexible polyimide substrate. To demonstrate the applicability of this novel sensing approach for critical diagnostic applications, we explored the current-voltage (I-V) hysteretic properties for the detection of prostate-specific antigen (PSA). To ensure sensitivity, we harnessed the adhesive properties of 3-glycidyloxypropyl trimethoxysilane (GOPS), to coat the surface of PEDOT:PSS-PVA and then grafted anti-PSA antibodies covalently in the polymeric channel. The layer-by-layer assembly was monitored using electrochemical and current-voltage memristive-like measurements. The specific anti-PSA antibodies assembled on the memristive-like channel enabled PSA detection in undiluted high ionic strength solutions within concentration ranging from 0.005 to 50 ng/ml. Our thin-film organic memristive-like devices show promise as cost-effective building blocks for memristive-like biosensing of PSA at clinically relevant levels (ng/ml).
- 3 January 2025
- Published by Springer Nature
- p. 244-250
Stability and Functionalization of Carbon Nanotube Electrolyte-Gated Field-Effect Transistors
- 3 January 2025
- Published by Springer Nature
- p. 244-250
Stability and Functionalization of Carbon Nanotube Electrolyte-Gated Field-Effect Transistors
- Open Access
- 18 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on AgriFood Electronics
- Vol. 3 (1) , 18-25
Advancements in the Development of Resistive-Based Method Applied to Optical Tracers for Real-Time Estimation of Spray Drift Deposition
The assessment of pesticide deposition is of key importance for the prevention of off-target area contamination, as well as to ensure the efficiency of the pesticide application. It is required by regulatory authorities also to quantify the drift potential of every possible sprayer configuration. As a matter of fact, the standard methodologies to compare sprayers' functional performance require large amounts of time, and the results are not always repeatable, due to the multitude of uncontrollable variables. This study proposes and tests an innovative approach in a laboratory wind tunnel based on resistive-based measurements applied to fluorescent tracers to address this challenge effectively. Our method utilizes screen-printed electrodes integrated into the material collector for measurement of the deposited material in real time shortly after the spray application. The estimation of the material by the standard optical method was also done along with the resistive-based method and compared with the measured weight used as a benchmark reference. Our experimental results demonstrated that both the optical and the resistive-based methods overestimated the amount of deposited material compared to weight measurement, but the overall estimation error remained below $\text{2.5} \,\text{g}$ . The measurements also showed that 90% of material deposition occurred at approximately $\text{11.5} \,\text{m}$ , providing valuable insights into the spatial distribution of sprayed materials. This real-time assessment leveraging resistive measurement techniques offers substantial benefits for laboratory testing of spraying machines and has also the potential for in-field resource management and monitoring. Despite the promising potential for real-time estimation of spray drift deposition, further research and testing are required to improve the method.
- 18 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on AgriFood Electronics
- Vol. 3 (1) , 18-25
Open AccessAdvancements in the Development of Resistive-Based Method Applied to Optical Tracers for Real-Time Estimation of Spray Drift Deposition
The assessment of pesticide deposition is of key importance for the prevention of off-target area contamination, as well as to ensure the efficiency of the pesticide application. It is required by regulatory authorities also to quantify the drift potential of every possible sprayer configuration. As a matter of fact, the standard methodologies to compare sprayers' functional performance require large amounts of time, and the results are not always repeatable, due to the multitude of uncontrollable variables. This study proposes and tests an innovative approach in a laboratory wind tunnel based on resistive-based measurements applied to fluorescent tracers to address this challenge effectively. Our method utilizes screen-printed electrodes integrated into the material collector for measurement of the deposited material in real time shortly after the spray application. The estimation of the material by the standard optical method was also done along with the resistive-based method and compared with the measured weight used as a benchmark reference. Our experimental results demonstrated that both the optical and the resistive-based methods overestimated the amount of deposited material compared to weight measurement, but the overall estimation error remained below $\text{2.5} \,\text{g}$ . The measurements also showed that 90% of material deposition occurred at approximately $\text{11.5} \,\text{m}$ , providing valuable insights into the spatial distribution of sprayed materials. This real-time assessment leveraging resistive measurement techniques offers substantial benefits for laboratory testing of spraying machines and has also the potential for in-field resource management and monitoring. Despite the promising potential for real-time estimation of spray drift deposition, further research and testing are required to improve the method.
- Open Access
- 23 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal on Flexible Electronics
- Vol. 3 (7) , 326-333
Integration of a Textile Electrode Into a Smart Glove for On-Field Analysis of Fruit Quality
In the field of smart agriculture, the on-site assessment of fruit quality is gaining an increased attention, due to the possibility it offers to precisely and rapidly evaluate fruit quality, enabling real-time decision making while reducing waste and ensuring a high-quality final produce. In this context, the extreme portability and flexibility of human hands-based tools, such as smart gloves, hold the potential to revolutionize the field. In this study, a textile-based wearable smart glove prototype is presented, combining textile thermoplastic polyurethane-carbon nanofiber (TPU-CNF)-based printed electrodes and a portable impedance analyzer, for on-site fruit monitoring applications. The presented conductive ink, prepared using TPU with a 50 wt% concentration of CNFs, is spray coated onto a stretchable Lycra fabric to prepare the electrodes. The realized electrodes presented good electromechanical behavior when subjected to strain stress of up to 250% (static) and 100% (dynamic, 1000 cycles) and displayed thermal-healing properties upon extreme damage, recovering up to 90% of the starting electrical properties. Furthermore, the employment for bioimpedance analysis on fruit provided reliable results in line with commercial electrodes up to frequencies of 500 kHz, well above the limit of employment of bioimpedance for fruit analysis with portable systems. The final integration within the proposed smart glove prototype, validated with a practical on-plant fruit bioimpedance analysis, proved the quality of the system and paves the way for its extensive on-field application.
- 23 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal on Flexible Electronics
- Vol. 3 (7) , 326-333
Open AccessIntegration of a Textile Electrode Into a Smart Glove for On-Field Analysis of Fruit Quality
In the field of smart agriculture, the on-site assessment of fruit quality is gaining an increased attention, due to the possibility it offers to precisely and rapidly evaluate fruit quality, enabling real-time decision making while reducing waste and ensuring a high-quality final produce. In this context, the extreme portability and flexibility of human hands-based tools, such as smart gloves, hold the potential to revolutionize the field. In this study, a textile-based wearable smart glove prototype is presented, combining textile thermoplastic polyurethane-carbon nanofiber (TPU-CNF)-based printed electrodes and a portable impedance analyzer, for on-site fruit monitoring applications. The presented conductive ink, prepared using TPU with a 50 wt% concentration of CNFs, is spray coated onto a stretchable Lycra fabric to prepare the electrodes. The realized electrodes presented good electromechanical behavior when subjected to strain stress of up to 250% (static) and 100% (dynamic, 1000 cycles) and displayed thermal-healing properties upon extreme damage, recovering up to 90% of the starting electrical properties. Furthermore, the employment for bioimpedance analysis on fruit provided reliable results in line with commercial electrodes up to frequencies of 500 kHz, well above the limit of employment of bioimpedance for fruit analysis with portable systems. The final integration within the proposed smart glove prototype, validated with a practical on-plant fruit bioimpedance analysis, proved the quality of the system and paves the way for its extensive on-field application.
- Open Access
- 27 August 2024
- Published by Elsevier in Computers and Electronics in Agriculture
- Vol. 226, 109347
Supervised classification and circuit parameter analysis of electrical bioimpedance spectroscopy data of water stress in tomato plants
- 27 August 2024
- Published by Elsevier in Computers and Electronics in Agriculture
- Vol. 226, 109347
Open AccessSupervised classification and circuit parameter analysis of electrical bioimpedance spectroscopy data of water stress in tomato plants
- Open Access
- 17 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (8) , 1-4
Flexible Electrochemical Sensor for Interleukin-6: Toward Wearable Cytokine Monitoring
The detection of cytokines, which are key proteins involved in immune system signaling, is of extreme importance for health monitoring. Among the various cytokines, interleukin-6 (IL-6) is particularly interesting to monitor, also considering that sweat IL-6 levels show a significant correlation with blood levels, in the range of pg/mL. Despite its importance, sensitive and wearable detection of IL-6 in sweat is still lagging behind. In this work, we fabricated and characterized a flexible screen-printed carbon-based three-electrode electrochemical sensor for IL-6 detection. The planar electrochemical sensor was first modified with gold nanoparticles (AuNPs) and then biofunctionalized with thiolated aptamers. The characterization via electrochemical impedance spectroscopy (EIS) demonstrated selective IL-6 detection in the range from 0.2 to 20 pg/mL in artificial sweat, perfectly covering the physiological range of interest. Our results suggest the potential integration of the developed flexible sensor into wearable devices for cytokine monitoring.
- 17 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (8) , 1-4
Open AccessFlexible Electrochemical Sensor for Interleukin-6: Toward Wearable Cytokine Monitoring
The detection of cytokines, which are key proteins involved in immune system signaling, is of extreme importance for health monitoring. Among the various cytokines, interleukin-6 (IL-6) is particularly interesting to monitor, also considering that sweat IL-6 levels show a significant correlation with blood levels, in the range of pg/mL. Despite its importance, sensitive and wearable detection of IL-6 in sweat is still lagging behind. In this work, we fabricated and characterized a flexible screen-printed carbon-based three-electrode electrochemical sensor for IL-6 detection. The planar electrochemical sensor was first modified with gold nanoparticles (AuNPs) and then biofunctionalized with thiolated aptamers. The characterization via electrochemical impedance spectroscopy (EIS) demonstrated selective IL-6 detection in the range from 0.2 to 20 pg/mL in artificial sweat, perfectly covering the physiological range of interest. Our results suggest the potential integration of the developed flexible sensor into wearable devices for cytokine monitoring.