Xuelei He
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xuelei He has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Xiaowei He
Northwest University
7 shared publications - Huangjian Yi
School of Information Sciences and Technology, Northwest University 2 , Xi’an
3 shared publications - Hongbo Guo
Northwest Univ. (China)
2 shared publications Jingjing Yu
Shaanxi Normal Univ. (China)
2 shared publications- Jingjing Yu
Shaanxi Normal University
2 shared publications Jintao Li
School of Information Science and Technology, Northwest University, No. 1 Xuefu Avenue, 710127 Xi'an, China; Xi'an Key Lab of Radiomics and Intelligent Perception, Northwest University, No. 1 Xuefu Avenue, 710127 Xi'an, China
2 shared publications
Latest Publications
- 21 July 2025
- Published by Elsevier in Physica Medica
- Vol. 136, 105050
Imaging-aided diagnosis and treatment based on artificial intelligence for pulmonary nodules: A review
- 21 July 2025
- Published by Elsevier in Physica Medica
- Vol. 136, 105050
Imaging-aided diagnosis and treatment based on artificial intelligence for pulmonary nodules: A review
- 12 September 2024
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 41 (10) , 1846-1855
Fluorescence separation based on the spatiotemporal Gaussian mixture model for dynamic fluorescence molecular tomography
Dynamic fluorescence molecular tomography (DFMT) is a promising imaging method that can furnish three-dimensional information regarding the absorption, distribution, and excretion of fluorescent probes in organisms. Achieving precise dynamic fluorescence images is the linchpin for realizing high-resolution, high-sensitivity, and high-precision tomography. Traditional preprocessing methods for dynamic fluorescence images often face challenges due to the non-specificity of fluorescent probes in living organisms, requiring complex imaging systems or biological interventions. These methods can result in significant processing errors, negatively impacting the imaging accuracy of DFMT. In this study, we present, a novel, to the best of our knowledge, strategy based on the spatiotemporal Gaussian mixture model (STGMM) for the processing of dynamic fluorescence images. The STGMM is primarily divided into four components: dataset construction, time domain prior information, spatial Gaussian fitting with time prior, and fluorescence separation. Numerical simulations and in vivo experimental results demonstrate that our proposed method significantly enhances image processing speed and accuracy compared to existing methods, especially when faced with fluorescence interference from other organs. Our research contributes to substantial reductions in time and processing complexity, providing robust support for dynamic imaging applications.
- 12 September 2024
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 41 (10) , 1846-1855
Fluorescence separation based on the spatiotemporal Gaussian mixture model for dynamic fluorescence molecular tomography
Dynamic fluorescence molecular tomography (DFMT) is a promising imaging method that can furnish three-dimensional information regarding the absorption, distribution, and excretion of fluorescent probes in organisms. Achieving precise dynamic fluorescence images is the linchpin for realizing high-resolution, high-sensitivity, and high-precision tomography. Traditional preprocessing methods for dynamic fluorescence images often face challenges due to the non-specificity of fluorescent probes in living organisms, requiring complex imaging systems or biological interventions. These methods can result in significant processing errors, negatively impacting the imaging accuracy of DFMT. In this study, we present, a novel, to the best of our knowledge, strategy based on the spatiotemporal Gaussian mixture model (STGMM) for the processing of dynamic fluorescence images. The STGMM is primarily divided into four components: dataset construction, time domain prior information, spatial Gaussian fitting with time prior, and fluorescence separation. Numerical simulations and in vivo experimental results demonstrate that our proposed method significantly enhances image processing speed and accuracy compared to existing methods, especially when faced with fluorescence interference from other organs. Our research contributes to substantial reductions in time and processing complexity, providing robust support for dynamic imaging applications.
- Open Access
Construction of a Food Safety Evaluation System Based on the Factor Analysis of Mixed Data Method
Food safety evaluation, which aims to reflect food safety status, is an important part of food safety management. Traditional food evaluation methods often consider limited data, and the evaluation process is subjective, time-consuming, and difficult to popularize. We developed a new food safety evaluation system that incorporates simple qualification degrees, food consumption, project hazard degrees, sales channels, food production regions, and other information obtained from food safety sampling and inspection to reflect the food safety situation accurately, objectively, and comprehensively. This evaluation model combined the statistical method and the machine learning method. The optimal distance method was used to calculate the basic qualification degree, and then expert elicitation via a questionnaire and the factor analysis of mixed data method (FADM) was applied to modify the basic qualification degree so as to obtain the food safety index, which indicates food safety status. Then, the effectiveness of this new method was verified by calculating and analyzing of the food safety index in region X. The results show that this model can clearly distinguish food safety levels in different cities and food categories and identify food safety trends in different years. Thus, this food safety evaluation system based on the FADM quantifies the real food safety level, screens out cities and food categories with high food safety risks, and, finally, helps to optimize the allocation of regulatory resources and provide technical and theoretical support for government decision-making.
Open AccessConstruction of a Food Safety Evaluation System Based on the Factor Analysis of Mixed Data Method
Food safety evaluation, which aims to reflect food safety status, is an important part of food safety management. Traditional food evaluation methods often consider limited data, and the evaluation process is subjective, time-consuming, and difficult to popularize. We developed a new food safety evaluation system that incorporates simple qualification degrees, food consumption, project hazard degrees, sales channels, food production regions, and other information obtained from food safety sampling and inspection to reflect the food safety situation accurately, objectively, and comprehensively. This evaluation model combined the statistical method and the machine learning method. The optimal distance method was used to calculate the basic qualification degree, and then expert elicitation via a questionnaire and the factor analysis of mixed data method (FADM) was applied to modify the basic qualification degree so as to obtain the food safety index, which indicates food safety status. Then, the effectiveness of this new method was verified by calculating and analyzing of the food safety index in region X. The results show that this model can clearly distinguish food safety levels in different cities and food categories and identify food safety trends in different years. Thus, this food safety evaluation system based on the FADM quantifies the real food safety level, screens out cities and food categories with high food safety risks, and, finally, helps to optimize the allocation of regulatory resources and provide technical and theoretical support for government decision-making.
- Open Access
- 1 June 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (06) , 066005-18
Neighbor-based adaptive sparsity orthogonal least square for fluorescence molecular tomography
SignificanceFluorescence molecular tomography (FMT) is a promising imaging modality, which has played a key role in disease progression and treatment response. However, the quality of FMT reconstruction is limited by the strong scattering and inadequate surface measurements, which makes it a highly ill-posed problem. Improving the quality of FMT reconstruction is crucial to meet the actual clinical application requirements.AimWe propose an algorithm, neighbor-based adaptive sparsity orthogonal least square (NASOLS), to improve the quality of FMT reconstruction.ApproachThe proposed NASOLS does not require sparsity prior information and is designed to efficiently establish a support set using a neighbor expansion strategy based on the orthogonal least squares algorithm. The performance of the algorithm was tested through numerical simulations, physical phantom experiments, and small animal experiments.ResultsThe results of the experiments demonstrated that the NASOLS significantly improves the reconstruction of images according to indicators, especially for double-target reconstruction.ConclusionNASOLS can recover the fluorescence target with a good location error according to simulation experiments, phantom experiments and small mice experiments. This method is suitable for sparsity target reconstruction, and it would be applied to early detection of tumors.
- 1 June 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (06) , 066005-18
Open AccessNeighbor-based adaptive sparsity orthogonal least square for fluorescence molecular tomography
SignificanceFluorescence molecular tomography (FMT) is a promising imaging modality, which has played a key role in disease progression and treatment response. However, the quality of FMT reconstruction is limited by the strong scattering and inadequate surface measurements, which makes it a highly ill-posed problem. Improving the quality of FMT reconstruction is crucial to meet the actual clinical application requirements.AimWe propose an algorithm, neighbor-based adaptive sparsity orthogonal least square (NASOLS), to improve the quality of FMT reconstruction.ApproachThe proposed NASOLS does not require sparsity prior information and is designed to efficiently establish a support set using a neighbor expansion strategy based on the orthogonal least squares algorithm. The performance of the algorithm was tested through numerical simulations, physical phantom experiments, and small animal experiments.ResultsThe results of the experiments demonstrated that the NASOLS significantly improves the reconstruction of images according to indicators, especially for double-target reconstruction.ConclusionNASOLS can recover the fluorescence target with a good location error according to simulation experiments, phantom experiments and small mice experiments. This method is suitable for sparsity target reconstruction, and it would be applied to early detection of tumors.
- 3 April 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12464, 849-854
Multi-source bioluminescene tomography reconstruction approach base on subspace decision
Bioluminescence tomography (BLT) reconstruction is an ill-posed problem. A class of strategy based on the permissible region (PR) reduces the ill-posed by reducing the space. However, in multi-objective reconstruction, the strategy is challenging to fit the sources of different positions. In this study, a subspace decision (SD) method is proposed, which transforms the traditional single permissible region into multiple spatially continuous subspaces by clustering, and performs spatial shrinkage optimization for each of them. In addition, a plug-and-play sliding single polyline module is introduced to analyze and cluster the reconstruction results each time to obtain the number and distribution of subspaces contained in the results. SD method does not rely on any specific reconstruction or clustering algorithm, so it has great flexibility. Experiment results show that the SD approach can more accurately obtain the spatial distribution information of different numbers of sources distributed in different locations and ensure the quality of multi-source BLT reconstruction. Keywords: Bioluminescence Tomography, Inverse Problem, Subspace, Clustering, Permissible Region.
- 3 April 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12464, 849-854
Multi-source bioluminescene tomography reconstruction approach base on subspace decision
Bioluminescence tomography (BLT) reconstruction is an ill-posed problem. A class of strategy based on the permissible region (PR) reduces the ill-posed by reducing the space. However, in multi-objective reconstruction, the strategy is challenging to fit the sources of different positions. In this study, a subspace decision (SD) method is proposed, which transforms the traditional single permissible region into multiple spatially continuous subspaces by clustering, and performs spatial shrinkage optimization for each of them. In addition, a plug-and-play sliding single polyline module is introduced to analyze and cluster the reconstruction results each time to obtain the number and distribution of subspaces contained in the results. SD method does not rely on any specific reconstruction or clustering algorithm, so it has great flexibility. Experiment results show that the SD approach can more accurately obtain the spatial distribution information of different numbers of sources distributed in different locations and ensure the quality of multi-source BLT reconstruction. Keywords: Bioluminescence Tomography, Inverse Problem, Subspace, Clustering, Permissible Region.
- 3 April 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12464, 898-903
Based on model-driven fast iterative shrinkage thresholding network for bioluminescence tomography reconstruction
Bioluminescence tomography (BLT) is an effective noninvasive molecular imaging modality, it has shown great potential for studying and monitoring disease progression in pre-clinical imaging. As the BLT is an inherent highly ill-posed inverse problem, it is still a challenge to obtain an accurate reconstruction result. Some algorithms have been proposed to solve highly ill posedness of inverse problems. Nevertheless, Existing methods always need to consume large time or have low interpretability. Thus, in this paper, we proposed a novel model-driven deep learning network, which unfolding the Fast Iterative Shrinkage Thresholding Algorithm (FISTA) algorithm into a deep network, named FISTA-Net to overcome the above shortcoming. FISTA-Net is formed from three modules, gradient descent module, proximal mapping module and accelerate module. Key parameters of FISTA-Net including the gradient step size, thresholding value are learned from training data. The experimental results, evaluated both visually and quantitatively, show that the FISTA-Net can achieve a high-quality reconstruction result of BLT.
- 3 April 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12464, 898-903
Based on model-driven fast iterative shrinkage thresholding network for bioluminescence tomography reconstruction
Bioluminescence tomography (BLT) is an effective noninvasive molecular imaging modality, it has shown great potential for studying and monitoring disease progression in pre-clinical imaging. As the BLT is an inherent highly ill-posed inverse problem, it is still a challenge to obtain an accurate reconstruction result. Some algorithms have been proposed to solve highly ill posedness of inverse problems. Nevertheless, Existing methods always need to consume large time or have low interpretability. Thus, in this paper, we proposed a novel model-driven deep learning network, which unfolding the Fast Iterative Shrinkage Thresholding Algorithm (FISTA) algorithm into a deep network, named FISTA-Net to overcome the above shortcoming. FISTA-Net is formed from three modules, gradient descent module, proximal mapping module and accelerate module. Key parameters of FISTA-Net including the gradient step size, thresholding value are learned from training data. The experimental results, evaluated both visually and quantitatively, show that the FISTA-Net can achieve a high-quality reconstruction result of BLT.
- 1 January 2016
- Published by Optica Publishing Group
- Vol. 49, AF3K.4
Efficient image reconstruction for fluorescence molecular tomography via linear regression approximation scheme with dual augmented lagrangian method
Fluorescence molecular tomography remains issue to obtain fast and accurate reconstruction. Here, we present an innovative method associating dual augmented lagrangian method with linear regression approximation strategy, which guarantees better location and computational efficiency for reconstruction.
- 1 January 2016
- Published by Optica Publishing Group
- Vol. 49, AF3K.4
Efficient image reconstruction for fluorescence molecular tomography via linear regression approximation scheme with dual augmented lagrangian method
Fluorescence molecular tomography remains issue to obtain fast and accurate reconstruction. Here, we present an innovative method associating dual augmented lagrangian method with linear regression approximation strategy, which guarantees better location and computational efficiency for reconstruction.