Bert Ungethüm
Bert Ungethüm has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Achim Walter Hassel
Institute of Chemical Technology of Inorganic Materials, Johannes Kepler University (JKU) Linz, Altenberger Strasse 69, 4040 Linz, Austria
1 shared publication - Adrian Onken
Biomaterial Engineering, ENT, Hannover Medical School, 30625 Hannover, Germany
1 shared publication - Alex Kontschev
Adlantis GmbH, 44263 Dortmund, Germany
1 shared publication Andreas Walte
Airsense Analytics GmbH
1 shared publication- Andreas Walte
AIRSENSE Analytics GmbH, 19061 Schwerin, Germany
1 shared publication Gerhard Matz
Hamburg University of Technology
1 shared publication
Latest Publications
- Open Access
Physical Trace Gas Identification with the Photo Electron Ionization Spectrometer (PEIS)
Chemosensor technology for trace gases in the air always aims to identify these compounds and then measure their concentrations. For identification, traceable methods are sparse and relate to large appliances such as mass spectrometers. We present a new method that uses the alternative traceable measurement of the ionization energies of trace gases in a way that can be miniaturized and energetically tuned. We investigate the achievable performance. Since tunable UV sources are not available for photoionization, we take a detour via impact ionization with electrons, which we generate using the photoelectric effect and bring to sharp, defined energies on a nanoscale in the air. Electron impact ionization is thus possible at air pressures of up to 900 hPa. The sensitivity of the process reaches 1 ppm and is equivalent to that of classic PID. With sharpened energy settings, substance identification is currently possible with an accuracy of 30 meV. We can largely explain the experimental observations with the known quantum mechanical models.
Open AccessPhysical Trace Gas Identification with the Photo Electron Ionization Spectrometer (PEIS)
Chemosensor technology for trace gases in the air always aims to identify these compounds and then measure their concentrations. For identification, traceable methods are sparse and relate to large appliances such as mass spectrometers. We present a new method that uses the alternative traceable measurement of the ionization energies of trace gases in a way that can be miniaturized and energetically tuned. We investigate the achievable performance. Since tunable UV sources are not available for photoionization, we take a detour via impact ionization with electrons, which we generate using the photoelectric effect and bring to sharp, defined energies on a nanoscale in the air. Electron impact ionization is thus possible at air pressures of up to 900 hPa. The sensitivity of the process reaches 1 ppm and is equivalent to that of classic PID. With sharpened energy settings, substance identification is currently possible with an accuracy of 30 meV. We can largely explain the experimental observations with the known quantum mechanical models.
- 25 September 2009
- Published by Springer Nature in International Journal for Ion Mobility Spectrometry
- Vol. 12 (4) , 131-137
Comparative measurements of toxic industrial compounds with a differential mobility spectrometer and a time of flight ion mobility spectrometer
- 25 September 2009
- Published by Springer Nature in International Journal for Ion Mobility Spectrometry
- Vol. 12 (4) , 131-137
Comparative measurements of toxic industrial compounds with a differential mobility spectrometer and a time of flight ion mobility spectrometer