CGCarolina Giordano

Carolina Giordano

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Carolina Giordano has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Dosimetric and clinical advantages of deep inspiration breath-hold (DIBH) during radiotherapy of breast cancer

    by Vicente Bruzzaniti, Armando Abate, Paola Pinnarò, Marco D’aNdrea, Erminia Infusino, Valeria Landoni, Antonella Soriani, Carolina Giordano, Anna Maria Ferraro, Lidia Strigari

    To investigate the potential dosimetric and clinical benefits of Deep Inspiration Breath-Hold (DIBH) technique during radiotherapy of breast cancer compared with Free Breathing (FB).


  • Open Access

    Evidence from a breast cancer hypofractionated schedule: late skin toxicity assessed by ultrasound

    by Valeria Landoni, Carolina Giordano, Annelisa Marsella, Biancamaria Saracino, Maria Grazia Petrongari, Anna Maria Ferraro, Lidia Strigari, Paola Pinnarò

    Feasibility of whole breast hypofractionated radiotherapy schedules in breast conserving therapy is recognized however concerns remain about the role of the boost dose on the overall treatment’s potential toxicity. In this study we report on the possibility to quantitatively evaluate radiation induced toxicity in patients treated with an abbreviated course with major concern in the irradiated boost region.


  • Development and optimization of a beam shaper device for a mobile dedicated IOERT accelerator

    by Antonella Soriani, Giuseppe Iaccarino, Giuseppe Felici, Alessia Ciccotelli, Paola Pinnarò, Carolina Giordano, Marcello Benassi, Marco Dˈandrea, Luca Bellesi, Lidia Strigari

    Purpose: The aim of this study was to design and build a prototype beam shaper to be used on a dedicated mobile accelerator that protects organs at risk within the radiation field and conforms the beam to the target geometry during intraoperative electron radiotherapy (IOERT). A dosimetric characterization of the beam shaper device was performed based on Monte Carlo (MC) simulations, as well as experimental data, at different energies, field sizes, and source to skin distances.Methods: A mobile light intraoperative accelerator (LIAC®, Sordina, Italy) was used. The design of the beam shaper prototype was based on MC simulations (BEAMnrc/OMEGA and DOSXYZnrc code) for a selection of materials and thicknesses, as well as for dosimetric characterization. Percentage depth dose (PDD) and profile measurements were performed using a p‐type silicon diode and a commercial water phantom, while output factors were measured using a PinPoint ion chamber in a PMMA phantom. Planar doses in planes of interest were carried out using radiochromic films (Gafchromic™ EBT and EBT2) in PMMA and in a Solid Water® phantom. Several experimental set‐ups were investigated with the beam shaper device fixed on the top of the phantom, varying both the short side of the rectangular field and the air gap between the device and the phantom surface, simulating the clinical situation. The output factors (OFs) were determined using different geometrical set‐ups and energies.Results: The beam shaper prototype consists of four blades sliding alongside each other and mounted on a special support at the end of the 10 cm diameter PMMA circular applicator. Each blade is made of an upper layer of 2.6 cm of Teflon® and a lower layer of 8 mm of stainless steel. All rectangles inscribed in a 5 cm diameter can be achieved in addition to any “squircle‐shaped” field. When one side of the rectangular field is held constant and the second side is reduced, both R50 and Rmax move towards the phantom surface. Comparing the PDDs obtained with the 5 cm circular applicator and with a 4.4 × 4.4 cm2 square field (that is the equivalent square of the 5 cm circular field) obtained with the beam shaper, a different behavior was observed in the region extending from the surface to a depth of 50% of the maximum dose. Isodoses measured for rectangular fields used for clinical cases (i.e., 4 × 9 cm2 8 MeV) are shown, with different air gaps. For each energy investigated, the normalized OFs slowly increase, when the length of the side decreases down to about 4 cm, and then rapidly decreases for smaller field widths. MC simulation showed an excellent agreement with experimental data (<2%).Conclusions: The beam shaper device is able to provide square/rectangular/squircle fields with adequate dose homogeneity for mobile dedicated accelerators, thus allowing conformal treatment with IOERT. Monte Carlo simulation can be a very useful tool to simulate any clinical set up and can be used to create a data set to calculate MUs, thereby increasing the accuracy of the delivered dose during IOERT procedures.


  • A New Model for Predicting Acute Mucosal Toxicity in Head-and-Neck Cancer Patients Undergoing Radiotherapy With Altered Schedules

    by Lidia Strigari, Piernicola Pedicini, Marco D’andrea, Paola Pinnarò, Laura Marucci, Carolina Giordano, Marcello Benassi


  • Open Access

    SNPs in DNA repair or oxidative stress genes and late subcutaneous fibrosis in patients following single shot partial breast irradiation

    by Elisabetta Falvo, Lidia Strigari, Gennaro Citro, Carolina Giordano, Genoveva Boboc, Fabiana Fabretti, Vicente Bruzzaniti, Luca Bellesi, Paola Muti, Giovanni Blandino, et al.

    The aim of this study was to evaluate the potential association between single nucleotide polymorphisms related response to radiotherapy injury, such as genes related to DNA repair or enzymes involved in anti-oxidative activities. The paper aims to identify marker genes able to predict an increased risk of late toxicity studying our group of patients who underwent a Single Shot 3D-CRT PBI (SSPBI) after BCS (breast conserving surgery).


  • Open Access

    Toxicity and cosmesis outcomes after single fraction partial breast irradiation in early stage breast cancer

    by Paola Pinnarò, Stefano Arcangeli, Carolina Giordano, Giorgio Arcangeli, Fabrizio Ambesi Impiombato, Valentina Pinzi, Giuseppe Iaccarino, Antonella Soriani, Valeria Landoni, Lidia Strigari

    Background: To report the clinical outcome after a Single Shot 3D-CRT PBI (SSPBI) in breast cancer patients after conservative surgery (ClinicalTrials.gov Identifier: NCT01316328). Methods: A dose of 18Gy (in the first 4 patients) and 21Gy (in the remaining 60 patients) was prescribed in a single session and delivered to the index area (i.e. the area of breast including the primary tumor bed and the surrounding tissue) using 3D-CRT with patients in prone position. Acute and late toxicity was assessed using the National Cancer Institute's CTC for Adverse Events. Cosmesis was defined based on modified Harvard criteria. Differences between dosimetric or clinical parameters of patients with/without G2 or more late toxicity or unsatisfactory (poor or fair) cosmetic outcome were evaluated with the Mann-Whitney test. Odds ratios and 95% confidence interval were calculated for cosmesis and fibrosis. Univariate and multivariate analyses(UVA/MVA) were used to determine covariates associated with an increase in fibrosis or fat necrosis rate. Results: Sixty four patients were enrolled. With a median follow-up of 3 years, G2 and G3 subcutaneous fibrosis was detected in 20(31%) and in 8(13%) patients, and ≥G2 fat necrosis was observed in 2(3%) patients. Good to excellent, fair and poor cosmesis was observed in 38(59%), 23(36%) and 3(5%) patients, respectively. Based on UVA, the breast volume receiving more than 21Gy (V21Gy) was found to be a predictor of the ≥G1 or ≥G2 fibrosis/fat necrosis. Based on MVA, V21Gy was confirmed as a predictor for ≥G1 fibrosis/fat necrosis, the results correlated as a trend for ≥G2. Cosmesis was correlated with whole breast (WB) mean dose (p = 0.030). Conclusion: Our choice of a single dose of 21Gy significantly increased the treatment related toxicity. However, this should not discourage novel SSPBI approaches with lower equivalent doses.


  • Open Access

    Dose and polymorphic genes xrcc1, xrcc3, gst play a role in the risk of developing erythema in breast cancer patients following single shot partial breast irradiation after conservative surgery

    by Elisabetta Falvo, Lidia Strigari, Gennaro Citro, Carolina Giordano, Stefano Arcangeli, Antonella Soriani, Daniela D'Alessio, Paola Muti, Giovanni Blandino, Isabella Sperduti, et al.

    To evaluate the association between polymorphisms involved in DNA repair and oxidative stress genes and mean dose to whole breast on acute skin reactions (erythema) in breast cancer (BC) patients following single shot partial breast irradiation (SSPBI) after breast conservative surgery.


  • Long-Term Results of a Randomized Trial on the Sequencing of Radiotherapy and Chemotherapy in Breast Cancer

    by Paola Pinnarò, Rita Rambone, Carolina Giordano, Diana Giannarelli, Lidia Strigari, Giorgio Arcangeli

    A prospective, phase III randomized study was undertaken to compare the outcomes of 2 different radiotherapy and chemotherapy sequences in conservatively treated patients with breast cancer. Between January 1997 and November 2002, 206 patients operated of quadrantectomy and axillary dissection for breast cancer, candidates to receive adjuvant CMF chemotherapy (cyclophosphamide, methotrexate, and fluorouracil) were assigned to concurrent or sequential radiation treatment by using a balanced randomization method. Before randomization patients were stratified by tumor diameter, age, and lymph node status. The primary end point was the freedom from breast recurrence, and secondary end points were overall and disease-free survival. Overall outcomes were analyzed according to the intention-to-treat principle. All 206 patients enrolled and randomized in the trial were analyzed. The median follow-up was 111 months, with no patient lost for follow-up. No difference in 10-years breast recurrence-free, disease-free, metastasis-free, and overall survival rates was observed in the 2 treatment sequence groups. The Hazard Ratios, calculated for each prognostic factor, showed no difference in all outcomes between the 2 treatment sequences. No influence of the treatment sequence on long-term outcomes was observed in this trial. This finding suggests that to avoid an increased risk of distant recurrence or an excessive toxicity, radiation therapy may be delayed until after the end of the more, recently used, anthracycline-based chemotherapy without increasing the risk of breast recurrences, thus allowing the delivery of full-dose chemotherapy in patients at risk for systemic disease spread.


  • Open Access

    Implementation of a new cost efficacy method for blood irradiation using a non dedicated device

    by Paola Pinnarò, Antonella Soriani, Daniela D'Alessio, Carolina Giordano, Maria Laura Foddai, Valentina Pinzi, Lidia Strigari

    Objectives: To implement a new cost efficacy internal Service for blood component irradiation, we carried out specific procedures and quality assurance reports using the linear accelerators (LINACs) of the Regina Elena Institute (IRE) Radiotherapy Department instead of a dedicated device. Methods: The technical aspects, quality assurance and regulatory requirements of the internal procedure to set up a local irradiated blood bank have been defined. The LINACs of the IRE Radiotherapy Department were used to deliver a mean dose of 32 Gy and dose accuracy was checked with gafchromic film. The overall time/cost of this procedure was compared with the previous procedure, out-sourcing the irradiation of blood components. Results: A total of 1996 blood component units were internally irradiated in the first year. Moreover, reducing the overall procedure time by a third. Overall cost/bag of external and internal procedures was approx. 66 € and 11 €, respectively. Thus the average saving of cost/bag was higher than 80%. The use of gafchromic films in all irradiated blood component bags allowed the accuracy of the dose delivered to blood to be checked. Conclusions: By utilizing LINACs installed in the Radiotherapy Department it is possible to provide an internal blood component irradiation service, capitalizing on internal resources without any inconvenience/discomfort to patients undergoing radiotherapy and satisfying governmental regulatory requirements. The internal irradiation procedures has proven to be safe and feasible, and along with the significant cost/time reduction suggests that it is more advantageous than external procedures.