Influence of the CleaRing intraocular open capsule device on refractive predictability in cataract surgery
BackgroundThe marked improvement in cataract surgery and intraocular lens (IOL) quality has led to a decline in posterior capsular opacification (PCO) incidence; however, PCO remains a common complication of cataract surgery. The CleaRing intraocular capsule open device (IOCD) decreases PCO incidence. We aimed to investigate the influence of the CleaRing IOCD on refractive predictability in cataract surgery. MethodsWe conducted this prospective pilot study at the Wolfson Medical Center, Holon, Israel. Ten eyes of patients who underwent cataract surgery and insertion of an IOL after IOCD implantation into the capsular bag were included. All patients completed 12 months of follow-up, including refraction, measurement of uncorrected (UDVA) and best-corrected distance visual acuity (CDVA), slit-lamp biomicroscopy, and ultrasound biomicroscopy. ResultsAll the surgeries were uneventful, with no postoperative complications. The IOL was centred in the device and bag in all cases. The mean prediction error at 1 and 12 months postoperatively was +0.28 & PLUSMN; 0.32 D and +0.50 & PLUSMN; 0.32 D, respectively. The mean UDVA was 0.17 & PLUSMN; 0.13 and 0.15 & PLUSMN; 0.11 logMAR, and the mean CDVA was 0.04 & PLUSMN; 0.10 and 0.04 & PLUSMN; 0.06 logMAR, respectively. The manifest refractive cylinders at 12 months postoperatively were compatible with corneal astigmatism. ConclusionsImplantation of the IOCD resulted in a slight, predicted, and stable hyperopic shift with a low standard deviation. The standard deviation of the prediction error demonstrated excellent refractive accuracy and predictability using the IOCD, which was as low as 0.32 D at the 12-month follow-up.
- 10 August 2023
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 51 (7) , 685-691
Influence of the CleaRing intraocular open capsule device on refractive predictability in cataract surgery
BackgroundThe marked improvement in cataract surgery and intraocular lens (IOL) quality has led to a decline in posterior capsular opacification (PCO) incidence; however, PCO remains a common complication of cataract surgery. The CleaRing intraocular capsule open device (IOCD) decreases PCO incidence. We aimed to investigate the influence of the CleaRing IOCD on refractive predictability in cataract surgery. MethodsWe conducted this prospective pilot study at the Wolfson Medical Center, Holon, Israel. Ten eyes of patients who underwent cataract surgery and insertion of an IOL after IOCD implantation into the capsular bag were included. All patients completed 12 months of follow-up, including refraction, measurement of uncorrected (UDVA) and best-corrected distance visual acuity (CDVA), slit-lamp biomicroscopy, and ultrasound biomicroscopy. ResultsAll the surgeries were uneventful, with no postoperative complications. The IOL was centred in the device and bag in all cases. The mean prediction error at 1 and 12 months postoperatively was +0.28 & PLUSMN; 0.32 D and +0.50 & PLUSMN; 0.32 D, respectively. The mean UDVA was 0.17 & PLUSMN; 0.13 and 0.15 & PLUSMN; 0.11 logMAR, and the mean CDVA was 0.04 & PLUSMN; 0.10 and 0.04 & PLUSMN; 0.06 logMAR, respectively. The manifest refractive cylinders at 12 months postoperatively were compatible with corneal astigmatism. ConclusionsImplantation of the IOCD resulted in a slight, predicted, and stable hyperopic shift with a low standard deviation. The standard deviation of the prediction error demonstrated excellent refractive accuracy and predictability using the IOCD, which was as low as 0.32 D at the 12-month follow-up.
- 1 July 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (7) , 704-710
Comparison of the Barrett toric calculator using measured and predicted posterior corneal astigmatism and the Kane and Abulafia-Koch calculators
Purpose: To compare the accuracy of the Barrett toric calculator with measured and predicted posterior corneal astigmatism (MPCA and PPCA, respectively), the Abulafia-Koch (AK) formula, and the toric Kane formula. Setting: Ein-Tal Eye Center, Tel-Aviv, Israel. Design: Retrospective cohort. Methods: Consecutive cases of patients who underwent uneventful cataract extraction surgery with implantation of a toric intraocular lens between March 2015 and July 2019 were retrospectively reviewed. 1 eligible eye from each patient was included. The predicted postoperative refractive astigmatism was calculated using each method and compared with the postoperative refractive astigmatism to give the prediction error. Results: 80 eyes of 80 patients were included in this study. The mean centroid and the mean and median absolute prediction errors using Kane (0.25 diopters [D] ± 0.54 @ 6 degrees, 0.50 D ± 0.31 and 0.45 D, respectively) were significantly different compared with MPCA (0.12 D ± 0.52 @ 16 degrees, P < .001, .44 D ± 0.28 and 0.36 D, P = .027, respectively), PPCA (0.09 D ± 0.49 @ 12 degrees, P < .001, .41 D ± 0.27 and 0.35 D, P < .001, respectively), and AK (0.11 D ± 0.49 @ 11 degrees, P < .001, .42 D ± 0.27 and 0.35 D, P = .004, respectively). No significant differences were found between the calculators in the predictability rates within ±0.25 D, ±0.50 D, ±0.75 D, and ±1.00 D. Conclusions: The measured posterior corneal curvature in the Barrett calculator yielded comparable outcomes to its prediction by the Barrett and AK formulas. The Kane calculator showed a slight against-the-rule prediction error compared with the other methods, resulting in a small higher median absolute error with marginal clinical importance.
- 1 July 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (7) , 704-710
Comparison of the Barrett toric calculator using measured and predicted posterior corneal astigmatism and the Kane and Abulafia-Koch calculators
Purpose: To compare the accuracy of the Barrett toric calculator with measured and predicted posterior corneal astigmatism (MPCA and PPCA, respectively), the Abulafia-Koch (AK) formula, and the toric Kane formula. Setting: Ein-Tal Eye Center, Tel-Aviv, Israel. Design: Retrospective cohort. Methods: Consecutive cases of patients who underwent uneventful cataract extraction surgery with implantation of a toric intraocular lens between March 2015 and July 2019 were retrospectively reviewed. 1 eligible eye from each patient was included. The predicted postoperative refractive astigmatism was calculated using each method and compared with the postoperative refractive astigmatism to give the prediction error. Results: 80 eyes of 80 patients were included in this study. The mean centroid and the mean and median absolute prediction errors using Kane (0.25 diopters [D] ± 0.54 @ 6 degrees, 0.50 D ± 0.31 and 0.45 D, respectively) were significantly different compared with MPCA (0.12 D ± 0.52 @ 16 degrees, P < .001, .44 D ± 0.28 and 0.36 D, P = .027, respectively), PPCA (0.09 D ± 0.49 @ 12 degrees, P < .001, .41 D ± 0.27 and 0.35 D, P < .001, respectively), and AK (0.11 D ± 0.49 @ 11 degrees, P < .001, .42 D ± 0.27 and 0.35 D, P = .004, respectively). No significant differences were found between the calculators in the predictability rates within ±0.25 D, ±0.50 D, ±0.75 D, and ±1.00 D. Conclusions: The measured posterior corneal curvature in the Barrett calculator yielded comparable outcomes to its prediction by the Barrett and AK formulas. The Kane calculator showed a slight against-the-rule prediction error compared with the other methods, resulting in a small higher median absolute error with marginal clinical importance.
- 1 December 2020
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 36 (12) , 820-825
Toric IOL Calculation in Eyes With High Posterior Corneal Astigmatism
PURPOSE: To evaluate different calculation approaches for toric intraocular lens (IOL) calculation in cases with high posterior corneal astigmatism (PCA). METHODS: Consecutive patients who underwent cataract extraction with implantation of toric IOLs by a single surgeon were reviewed. Eyes with measured PCA of 0.80 diopters (D) or greater were included. Errors in the predicted postoperative refractive astigmatism were calculated for the Abulafia-Koch formula, vector summation of anterior keratometry with posterior tomography, and the Barrett toric calculator using predicted and measured PCA. RESULTS: One hundred seventy-three consecutive cases of toric IOL implantation were reviewed. Seventeen eyes (10%) had PCA of 0.80 D or greater and were investigated. The mean absolute error was the lowest with Barrett's measured PCA (0.55 ± 0.38) followed by Barrett's predicted PCA mean absolute error (0.65 ± 0.31), vector summation (0.69 ± 0.33), and the Abulafia-Koch formula (0.80 ± 0.36). The rate of eyes with prediction errors within 0.25 D or less was the highest for Barrett's measured PCA (29.4%) followed by Barrett's predicted PCA (5.9%) and no eyes for the Abulafia-Koch formula and vector summation. The mean centroid prediction errors were lowest for Barrett's measured PCA and Barrett's predicted PCA (0.14 ± 0.66 @70, 0.14 ± 0.73 @179, respectively), followed by vector summation (0.35 ± 0.70 @5), and the Abulafia-Koch formula (0.39 ± 0.80 @179). CONCLUSIONS: The results suggest that in cases of high PCA, the Barrett toric calculator using direct measurements of PCA may have a potential advantage over predicted PCA in toric IOL calculations and vector summation of the anterior and posterior corneal astigmatism. [ J Refract Surg . 2020;36(12):820–825.]
- 1 December 2020
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 36 (12) , 820-825
Toric IOL Calculation in Eyes With High Posterior Corneal Astigmatism
PURPOSE: To evaluate different calculation approaches for toric intraocular lens (IOL) calculation in cases with high posterior corneal astigmatism (PCA). METHODS: Consecutive patients who underwent cataract extraction with implantation of toric IOLs by a single surgeon were reviewed. Eyes with measured PCA of 0.80 diopters (D) or greater were included. Errors in the predicted postoperative refractive astigmatism were calculated for the Abulafia-Koch formula, vector summation of anterior keratometry with posterior tomography, and the Barrett toric calculator using predicted and measured PCA. RESULTS: One hundred seventy-three consecutive cases of toric IOL implantation were reviewed. Seventeen eyes (10%) had PCA of 0.80 D or greater and were investigated. The mean absolute error was the lowest with Barrett's measured PCA (0.55 ± 0.38) followed by Barrett's predicted PCA mean absolute error (0.65 ± 0.31), vector summation (0.69 ± 0.33), and the Abulafia-Koch formula (0.80 ± 0.36). The rate of eyes with prediction errors within 0.25 D or less was the highest for Barrett's measured PCA (29.4%) followed by Barrett's predicted PCA (5.9%) and no eyes for the Abulafia-Koch formula and vector summation. The mean centroid prediction errors were lowest for Barrett's measured PCA and Barrett's predicted PCA (0.14 ± 0.66 @70, 0.14 ± 0.73 @179, respectively), followed by vector summation (0.35 ± 0.70 @5), and the Abulafia-Koch formula (0.39 ± 0.80 @179). CONCLUSIONS: The results suggest that in cases of high PCA, the Barrett toric calculator using direct measurements of PCA may have a potential advantage over predicted PCA in toric IOL calculations and vector summation of the anterior and posterior corneal astigmatism. [ J Refract Surg . 2020;36(12):820–825.]