William Chu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
William Chu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Hsin-Tzu Lu
Institute of Biomedical Engineering, National Yang-Ming Chiao-Tung University, Taipei 11221, Taiwan
2 shared publications - Woei-Chyn Chu
Institute of Biomedical Engineering, National Yang-Ming Chiao-Tung University, Taipei 11221, Taiwan
2 shared publications - Chuan Li
Department of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei 300093, Taiwan
1 shared publication - Chung-Yi Chen
Institute of Biomedical Engineering, National Yang-Ming Chiao-Tung University, Taipei 11221, Taiwan
1 shared publication - Jia-Yi Lin
Institute of Biomedical Engineering, National Yang-Ming Chiao-Tung University, Taipei 11221, Taiwan
1 shared publication - Shih-Hao Cheng
Institute of Biomedical Engineering, National Yang-Ming Chiao-Tung University, Taipei 11221, Taiwan
1 shared publication
Latest Publications
- Open Access
- 7 January 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (2) , 481
Intraoperative Suction-Assisted Kyphoplasty for Immediate Removal of Posterior PMMA Extravasation in Decompressed Vertebral Compression Fractures
Background: Vertebral compression fractures are prevalent in elderly patients with osteoporosis. While the vertebral augmentation procedure is often used for symptom control and improving life quality, cement leakage is still a significant complication of vertebral augmentation procedures. This case report describes a 92-year-old man with a T8 compression fracture who underwent kyphoplasty with low-viscosity bone cement after failed conservative treatment. Methods: A previously developed decompressed kyphoplasty technique using dual portals was employed to reduce intravertebral pressure; however, fluoroscopy revealed posterior leakage toward the spinal canal. A case-specific intraoperative modification of this established technique was then applied, converting the injection portal into a suction channel to aspirate extravasated cement before it hardened. Results: This approach averted spinal cord compromise, obviated the need for additional decompression surgery, and preserved neurological function. The patient achieved rapid pain relief and early mobilization. Conclusions: This case demonstrates how a suction-assisted intraoperative maneuver may be used to manage posterior cement leakage during decompressed kyphoplasty.
- 7 January 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (2) , 481
Open AccessIntraoperative Suction-Assisted Kyphoplasty for Immediate Removal of Posterior PMMA Extravasation in Decompressed Vertebral Compression Fractures
Background: Vertebral compression fractures are prevalent in elderly patients with osteoporosis. While the vertebral augmentation procedure is often used for symptom control and improving life quality, cement leakage is still a significant complication of vertebral augmentation procedures. This case report describes a 92-year-old man with a T8 compression fracture who underwent kyphoplasty with low-viscosity bone cement after failed conservative treatment. Methods: A previously developed decompressed kyphoplasty technique using dual portals was employed to reduce intravertebral pressure; however, fluoroscopy revealed posterior leakage toward the spinal canal. A case-specific intraoperative modification of this established technique was then applied, converting the injection portal into a suction channel to aspirate extravasated cement before it hardened. Results: This approach averted spinal cord compromise, obviated the need for additional decompression surgery, and preserved neurological function. The patient achieved rapid pain relief and early mobilization. Conclusions: This case demonstrates how a suction-assisted intraoperative maneuver may be used to manage posterior cement leakage during decompressed kyphoplasty.
- Open Access
- 3 July 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (7) , 795
Impact of Aspiration Percutaneous Vertebroplasty in Reducing Bone Cement Leakage and Enhancing Distribution—An Ex Vivo Study in Goat Vertebrae
Osteoporosis-induced vertebral compression fracture (OVCF) occurs commonly in people over the age of 50, especially among menopausal women. Besides conservative therapy, minimally invasive percutaneous vertebroplasty (PVP) and kyphoplasty (PKP) have been widely used in clinical treatment and achieved good efficacy. However, the leakage of bone cement (CL) during vertebroplasty (PV) is a major risk that can cause (serious) complications such as compression of the spinal cord, pulmonary embolism, or even paraplegia. In this study, we introduced a new aspiration technique with standard PV procedures (APV) to ameliorate the risk of leakage with quantitative verifications of its effectiveness. APV intends to create a differential pressure to guide the direction of cement flow within the vertebrae. To test this technique, Nubian goats’ ex vivo vertebral bodies (VBs) were used to simulate the PV surgical process in humans. Results show that the proposed APV has a lower leakage rate of 13% compared to the 53% of conventional PV. Additionally, the APV approach achieves more uniform cement distribution via the 9-score method with a value of 7 ± 1.30 in contrast to 4 ± 1.78 by conventional PV.
- 3 July 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (7) , 795
Open AccessImpact of Aspiration Percutaneous Vertebroplasty in Reducing Bone Cement Leakage and Enhancing Distribution—An Ex Vivo Study in Goat Vertebrae
Osteoporosis-induced vertebral compression fracture (OVCF) occurs commonly in people over the age of 50, especially among menopausal women. Besides conservative therapy, minimally invasive percutaneous vertebroplasty (PVP) and kyphoplasty (PKP) have been widely used in clinical treatment and achieved good efficacy. However, the leakage of bone cement (CL) during vertebroplasty (PV) is a major risk that can cause (serious) complications such as compression of the spinal cord, pulmonary embolism, or even paraplegia. In this study, we introduced a new aspiration technique with standard PV procedures (APV) to ameliorate the risk of leakage with quantitative verifications of its effectiveness. APV intends to create a differential pressure to guide the direction of cement flow within the vertebrae. To test this technique, Nubian goats’ ex vivo vertebral bodies (VBs) were used to simulate the PV surgical process in humans. Results show that the proposed APV has a lower leakage rate of 13% compared to the 53% of conventional PV. Additionally, the APV approach achieves more uniform cement distribution via the 9-score method with a value of 7 ± 1.30 in contrast to 4 ± 1.78 by conventional PV.