Wentao Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wentao Li has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Jiansheng Liu
Department of Physics, Shanghai Normal University, Shanghai, China
4 shared publications - Changhai Yu
Shanghai Normal University
3 shared publications Cheng Wang
State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences 1 , Shanghai 201800, China
3 shared publicationsJiaqi Liu
State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences 1 , Shanghai 201800, China
3 shared publicationsKe Feng
State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences 1 , Shanghai 201800, China
3 shared publications- Ming Fang
State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences 1 , Shanghai 201800, China
3 shared publications
Latest Publications
- Open Access
- 1 October 2018
- Published by AIP Publishing in AIP Advances
- Vol. 8 (10) , 105204
Measurement of the matched spot size in a capillary discharge waveguide with a collimated laser
Measurement of the matched spot size in the hydrogen-filled capillary discharge waveguide based on the spot size oscillation of a collimated laser is presented in this paper. The spot size oscillation trace is retrieved from the laser modes measured at the exits of discharged capillaries of different lengths under the same discharge conditions. With the gas pressure, peak discharge electric current and capillary radius fixed, the radial density profiles are identical in all the discharged capillaries. The measured laser modes are equivalent to the evolution at discrete positions in a long plasma channel. Compared to former researches based on the spot size at the capillary exit, this method is not affected by the multiple solution problem. The use of a collimated laser eliminates the influences of the divergence angle on the fitting accuracy. By this means, the matched spot sizes of hydrogen-filled capillary discharge waveguides under different gas pressures (5-20mbar) are measured. The results can provide a spot size reference for the laser wakefield accelerator guided in a plasma channel.
- 1 October 2018
- Published by AIP Publishing in AIP Advances
- Vol. 8 (10) , 105204
Open AccessMeasurement of the matched spot size in a capillary discharge waveguide with a collimated laser
Measurement of the matched spot size in the hydrogen-filled capillary discharge waveguide based on the spot size oscillation of a collimated laser is presented in this paper. The spot size oscillation trace is retrieved from the laser modes measured at the exits of discharged capillaries of different lengths under the same discharge conditions. With the gas pressure, peak discharge electric current and capillary radius fixed, the radial density profiles are identical in all the discharged capillaries. The measured laser modes are equivalent to the evolution at discrete positions in a long plasma channel. Compared to former researches based on the spot size at the capillary exit, this method is not affected by the multiple solution problem. The use of a collimated laser eliminates the influences of the divergence angle on the fitting accuracy. By this means, the matched spot sizes of hydrogen-filled capillary discharge waveguides under different gas pressures (5-20mbar) are measured. The results can provide a spot size reference for the laser wakefield accelerator guided in a plasma channel.
- 1 July 2018
- Published by AIP Publishing in Physics of Plasmas
- Vol. 25 (7) , 073102
Hybrid capillary discharge waveguide for laser wakefield acceleration
A hybrid capillary discharge waveguide formed by injecting low-pressure hydrogen (<3.8 Torr) into a pure ablative capillary is presented to supply the stable guiding for multi-GeV laser wakefield acceleration. The injected low-pressure gas only provides the seed plasma for ablative discharge breakdown, like the adsorbed gas in the inner wall of the ablative capillary. With this hybrid capillary, a stable discharge with low jitter (∼5 ns) can be achieved in a simple way, and the plasma density inside the plasma channel can also be controlled in the range of ∼ – within a 150-ns temporal window. Furthermore, the hybrid capillary can also be easily extended to a longer length by adding multiple segments, and femtosecond laser pulses can be well guided in both the single and multiple segment modes. With these advantages, the hybrid capillary may provide an attractive plasma channel for multi-GeV-scale laser wakefield acceleration.- 1 July 2018
- Published by AIP Publishing in Physics of Plasmas
- Vol. 25 (7) , 073102
Hybrid capillary discharge waveguide for laser wakefield acceleration
A hybrid capillary discharge waveguide formed by injecting low-pressure hydrogen (<3.8 Torr) into a pure ablative capillary is presented to supply the stable guiding for multi-GeV laser wakefield acceleration. The injected low-pressure gas only provides the seed plasma for ablative discharge breakdown, like the adsorbed gas in the inner wall of the ablative capillary. With this hybrid capillary, a stable discharge with low jitter (∼5 ns) can be achieved in a simple way, and the plasma density inside the plasma channel can also be controlled in the range of ∼ – within a 150-ns temporal window. Furthermore, the hybrid capillary can also be easily extended to a longer length by adding multiple segments, and femtosecond laser pulses can be well guided in both the single and multiple segment modes. With these advantages, the hybrid capillary may provide an attractive plasma channel for multi-GeV-scale laser wakefield acceleration.- 1 April 2018
- Published by AIP Publishing in Physics of Plasmas
- Vol. 25 (4) , 043117
Optimization of gas-filled quartz capillary discharge waveguide for high-energy laser wakefield acceleration
A hydrogen-filled capillary discharge waveguide made of quartz is presented for high-energy laser wakefield acceleration (LWFA). The experimental parameters (discharge current and gas pressure) were optimized to mitigate ablation by a quantitative analysis of the ablation plasma density inside the hydrogen-filled quartz capillary. The ablation plasma density was obtained by combining a spectroscopic measurement method with a calibrated gas transducer. In order to obtain a controllable plasma density and mitigate the ablation as much as possible, the range of suitable parameters was investigated. The experimental results demonstrated that the ablation in the quartz capillary could be mitigated by increasing the gas pressure to ∼7.5–14.7 Torr and decreasing the discharge current to ∼70–100 A. These optimized parameters are promising for future high-energy LWFA experiments based on the quartz capillary discharge waveguide.
- 1 April 2018
- Published by AIP Publishing in Physics of Plasmas
- Vol. 25 (4) , 043117
Optimization of gas-filled quartz capillary discharge waveguide for high-energy laser wakefield acceleration
A hydrogen-filled capillary discharge waveguide made of quartz is presented for high-energy laser wakefield acceleration (LWFA). The experimental parameters (discharge current and gas pressure) were optimized to mitigate ablation by a quantitative analysis of the ablation plasma density inside the hydrogen-filled quartz capillary. The ablation plasma density was obtained by combining a spectroscopic measurement method with a calibrated gas transducer. In order to obtain a controllable plasma density and mitigate the ablation as much as possible, the range of suitable parameters was investigated. The experimental results demonstrated that the ablation in the quartz capillary could be mitigated by increasing the gas pressure to ∼7.5–14.7 Torr and decreasing the discharge current to ∼70–100 A. These optimized parameters are promising for future high-energy LWFA experiments based on the quartz capillary discharge waveguide.