Jianbin Cao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jianbin Cao has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Dawei Tu
Shanghai University
2 shared publications - Xu Zhang
Shanghai University
2 shared publications Dawei Tu
1 shared publicationGuangya Zhou
1 shared publication- Tianhong Wang
Shanghai Key Laboratory of Intelligent Manufacturing and Robotics, School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, China
1 shared publication - Xingzhao Wang
School of Mechatronic Engineering and Automation, Shanghai University, Shanghai 200444, People’s Republic of China
1 shared publication
Latest Publications
- 3 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Improved Three-Mirror Geometry Calibration Method With Visual Guidance for Phase Measuring Deflectometry
Phase measuring deflectometry (PMD) has been widely applied to measuring specular objects. However, the placement of the calibration mirror is still a challenge: excessively large or small angles may cause the calibration algorithm to fail or render the optimization matrix is rank-deficient. To address this issue, we implemented the 3-mirror method, which is a maker-free calibration method that widely applied in the PMD field, and to improve it from two aspects. Firstly, the original 3-mirror method is limited by the number of mirror poses. The proposed ”Group-optimal” method enumerates all possible combinations by grouping them in triplets of mirror poses, and then the solutions for each triplet will be filtered with a threshold and be regard as initial values to converge the algorithm. This process allows the algorithm to calibrate system using data from more poses. Secondly, the algorithm could automatically generate the next optimal pose and guide the users in positioning the mirror’s pose, ensuring the optimization matrix is full-Rank, i.e., the solution is not ambiguity. Experiments have proved the validity: The red Peak and valley (PV) value of the measured plane mirror was reduced from the original 221.80 nm to 74.05 nm, and the Root mean square (RMS) value was decreased from 66.56 nm to 19.82 nm. The PV value of the measured spherical mirror was reduced from the original 256.31 nm to 127.49 nm, and the RMS value was decreased from 87.22 nm to 45.87 nm. Compared with other calibration methods, this method does not require a marker or customized calibration mirror and achieves the same level of accuracy, which is providing a more flexible, economical, and efficient approach for a PMD system in large-scale industry applications.
- 3 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Improved Three-Mirror Geometry Calibration Method With Visual Guidance for Phase Measuring Deflectometry
Phase measuring deflectometry (PMD) has been widely applied to measuring specular objects. However, the placement of the calibration mirror is still a challenge: excessively large or small angles may cause the calibration algorithm to fail or render the optimization matrix is rank-deficient. To address this issue, we implemented the 3-mirror method, which is a maker-free calibration method that widely applied in the PMD field, and to improve it from two aspects. Firstly, the original 3-mirror method is limited by the number of mirror poses. The proposed ”Group-optimal” method enumerates all possible combinations by grouping them in triplets of mirror poses, and then the solutions for each triplet will be filtered with a threshold and be regard as initial values to converge the algorithm. This process allows the algorithm to calibrate system using data from more poses. Secondly, the algorithm could automatically generate the next optimal pose and guide the users in positioning the mirror’s pose, ensuring the optimization matrix is full-Rank, i.e., the solution is not ambiguity. Experiments have proved the validity: The red Peak and valley (PV) value of the measured plane mirror was reduced from the original 221.80 nm to 74.05 nm, and the Root mean square (RMS) value was decreased from 66.56 nm to 19.82 nm. The PV value of the measured spherical mirror was reduced from the original 256.31 nm to 127.49 nm, and the RMS value was decreased from 87.22 nm to 45.87 nm. Compared with other calibration methods, this method does not require a marker or customized calibration mirror and achieves the same level of accuracy, which is providing a more flexible, economical, and efficient approach for a PMD system in large-scale industry applications.
- 8 October 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (10) , 105202
Fringe projection profilometry with lightweight transformer-CNN network for high-dynamic-range scenes
3D reconstruction of high-dynamic-range (HDR) scenes using a minimal number of images is a critical challenge for fringe projection profilometry. Deep learning (DL) has demonstrated significant potential, but previous approaches have never considered a balance between accuracy and speed, resulting in a slow inference latency for networks. A lightweight U-shaped transformer-CNN architecture is proposed that integrates dual attention mechanisms (channel and pixel attention) which enable the network to focus more attention on HDR regions. In addition, an efficient transformer (ET) layer establishes a longer dependence that enables compensation for the HDR regions by utilizing their surrounding pixels’ phase information. To address the data scarcity challenge, the network is first pre-trained on a synthetic dataset and subsequently fine-tuned using a real-world dataset that contains 720 HDR scenes. Experiments have proven that the proposed network achieves a phase error as low as 5.32 × 10 − 4 rad with it only containing 0.55 million parameters and a real-time processing speed of 16.56 frames per second (FPS) on an RTX 4060 GPU. Compared with other networks, the proposed network provides an effective phase recovery performance with faster inference speed for HDR scene reconstruction, which is crucial for actual industry applications.
- 8 October 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (10) , 105202
Fringe projection profilometry with lightweight transformer-CNN network for high-dynamic-range scenes
3D reconstruction of high-dynamic-range (HDR) scenes using a minimal number of images is a critical challenge for fringe projection profilometry. Deep learning (DL) has demonstrated significant potential, but previous approaches have never considered a balance between accuracy and speed, resulting in a slow inference latency for networks. A lightweight U-shaped transformer-CNN architecture is proposed that integrates dual attention mechanisms (channel and pixel attention) which enable the network to focus more attention on HDR regions. In addition, an efficient transformer (ET) layer establishes a longer dependence that enables compensation for the HDR regions by utilizing their surrounding pixels’ phase information. To address the data scarcity challenge, the network is first pre-trained on a synthetic dataset and subsequently fine-tuned using a real-world dataset that contains 720 HDR scenes. Experiments have proven that the proposed network achieves a phase error as low as 5.32 × 10 − 4 rad with it only containing 0.55 million parameters and a real-time processing speed of 16.56 frames per second (FPS) on an RTX 4060 GPU. Compared with other networks, the proposed network provides an effective phase recovery performance with faster inference speed for HDR scene reconstruction, which is crucial for actual industry applications.
- 29 May 2023
- Published by Elsevier in Measurement
- Vol. 218
A visual guidance calibration method for out-of-focus cameras based on iterative phase target
- 29 May 2023
- Published by Elsevier in Measurement
- Vol. 218
A visual guidance calibration method for out-of-focus cameras based on iterative phase target