GMGregory P. McLennan

Gregory P. McLennan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gregory P. McLennan has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Judith A. Boura

    From the *William Beaumont School of Medicine, Oakland University, Royal Oak, MI; and †Department of Urology, William Beaumont Hospital, Royal Oak, MI

    2 shared publications
  • Larry T. Sirls

    William Beaumont School of Medicine, Oakland University, Royal Oak, MI, USA

    2 shared publications
  • Dmitriy Nikolavsky

    Department of Urology, SUNY Upstate Medical University, Syracuse, NY, USA

    1 shared publication
  • Kenneth M. Peters

    Oakland University William Beaumont Hospital

    1 shared publication
  • Kenneth Peters

    From the *William Beaumont School of Medicine, Oakland University, Royal Oak, MI; and †Department of Urology, William Beaumont Hospital, Royal Oak, MI

    1 shared publication
  • Kim A. Killinger

    Oakland University William Beaumont Hospital

    1 shared publication

Latest Publications

  • Exploring Predictors of Mesh Exposure After Vaginal Prolapse Repair

    by Larry T. Sirls, Gregory P. McLennan, Kim A. Msn Killinger, Judith A. Boura, Melissa Fischer, Pradeep Nagaraju, Kenneth Peters

    Objectives: To evaluate clinical, demographic, and surgical factors that may be associated with mesh exposure after vaginal repair of pelvic organ prolapse (POP). Methods: Records of women who underwent POP repair with Elevate or Prolift were retrospectively reviewed. Body mass index (BMI), prolapse grade, smoking history, diabetes, steroid and estrogen use, parity, compartment repaired, concurrent hysterectomy, operative time, postoperative pain, change in hemoglobin (ΔHgb) and other characteristics were evaluated for associations with mesh exposure. Categorical variables were examined using Pearson χ2 test where appropriate, or the Fisher exact test was used. The continuous variables were examined using Wilcoxon rank tests. A multivariable logistic regression analysis was completed to examine predictors of mesh exposure. All analyses used SAS for Windows version 9.2 (Cary, NC). Results: Three hundred thirty-five women underwent repair from 2006 to 2011. Vaginal mesh exposure was identified in 27 (8.1%) of the 335 women. Patients with exposure had longer median follow-up than the group with no exposure (357 vs 145 days; P = 0.0003). The median time to exposure was 96 days (15–1129 days). Mesh exposure was associated with lower BMI (25.2 ± 2.5 vs 27.4 ± 5.1; P = 0.020) and greater ΔHgb (−3.7 ± 1.7 mg/dL vs −2.5 ±1.3; P = 0.0011). Change in hemoglobin decreased over time (P = 0.0005). Exposure rates also decreased over time (17% in 2005 to 12% in 2006, then 5%–8% in 2006–2011) but were not statistically significant (P = 0.49). Conclusions: In this study, vaginal mesh exposure was only associated with ΔHgb and lower BMI.


  • Perioperative experience of pelvic organ prolapse repair with the Prolift® and Elevate® vaginal mesh procedures

    by Gregory P. McLennan, Larry T. Sirls, Kim A. Killinger, Dmitriy Nikolavsky, Judith A. Boura, Melissa C. Fischer, Kenneth M. Peters

    We compared the operative and immediate postoperative experience of the trocar-based Prolift® and non-trocar-based Elevate® techniques used to repair vaginal prolapse. A retrospective review of Prolift and Elevate repairs was performed. Baseline characteristics and operative and postoperative variables evaluated included compartment(s) repaired, adjacent organ injury, operative time (OT), change in hemoglobin (ΔH), pain score, narcotic use, length of stay (LOS), and short-term complications. Categorical variables were assessed as counts and percent frequency. Data were compared using chi-squared analysis and paired t test. Prolift (n = 143) and Elevate (n = 77) patients were similar in age (p = 0.19). Concurrent hysterectomy was done in 22 (15.4 %) and 24 (31.2 %), respectively, and concurrent midurethral sling placed in 100 (70 %) and 50 (65 %), respectively. LOS (median, 25th,75th) after anterior/apical compartment repairs was shorter with Elevate, whether with (1.0; 1.0,1.5 vs. 2.0 days;1.0, 2.0; p = 0.003) or without (2.0; 1.0, 2.0 vs. 2.0 days; 2.0, 3.0; p = 0.024) hysterectomy, but no differences in OT, ΔH, pain score, or narcotic use occurred. Posterior compartment mean pain scores were lower with Prolift (3.6 ± 2.2 vs. 1.7 ± 1.5, p = 0.035), and three-compartment-repair pain scores were lower with Elevate (0.6 ± 1.3 vs 2.5 ± 1.9; p = 0.013). Three bladder injuries occurred with Prolift but none with Elevate. Operative and postoperative experiences were similar between groups; however, Elevate anterior/apical repairs had shorter LOS, which might reflect more aggressive discharge planning. There were no bowel or major vascular injuries, and the Prolift trocar bladder injuries did not alter the surgical procedure.