Marlee Krieger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Marlee Krieger has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Nirmala Ramanujam
Center for Global Women’s Health Technologies, Duke University, Durham, USA
5 shared publications - Gregory M. Palmer
Department of Radiation Oncology, Duke University , Durham, NC 27708
2 shared publications - Mark W. Dewhirst
Department of Radiation Oncology, Duke University School of Medicine, Durham, NC 27710, USA
2 shared publications - Mary Elizabeth Dotson
Duke University
2 shared publications - Walter Tsong Lee
Duke University School of Medicine, USA
2 shared publications Alaatin Erkanli
Duke University Medical Center, Department of Biostatistics and Bioinformatics, Durham, North Caroli (United States)
1 shared publication
Latest Publications
- Open Access
- 24 February 2023
- Published by MDPI AG in Current Oncology
- Vol. 30 (3) , 2751-2760
A Clinical Study to Assess Diffuse Reflectance Spectroscopy with an Auto-Calibrated, Pressure-Sensing Optical Probe in Head and Neck Cancer
Diffuse reflectance spectroscopy (DRS) is a powerful tool for quantifying optical and physiological tissue properties such as hemoglobin oxygen saturation and vascularity. DRS is increasingly used clinically for distinguishing cancerous lesions from normal tissue. However, its widespread clinical acceptance is still limited due to uncontrolled probe–tissue interface pressure that influences reproducibility and introduces operator-dependent results. In this clinical study, we assessed and validated a pressure-sensing and automatic self-calibration DRS in patients with suspected head and neck squamous cell carcinoma (HNSCC). The clinical study enrolled nineteen patients undergoing HNSCC surgical biopsy procedures. Patients consented to evaluation of this improved DRS system during surgery. For each patient, we obtained 10 repeated measurements on one tumor site and one distant normal location. Using a Monte Carlo-based model, we extracted the hemoglobin saturation data along with total hemoglobin content and scattering properties. A total of twelve cancer tissue samples from HNSCC patients and fourteen normal tissues were analyzed. A linear mixed effects model tested for significance between repeated measurements and compared tumor versus normal tissue. These results demonstrate that cancerous tissues have a significantly lower hemoglobin saturation compared to normal controls (p < 0.001), which may be reflective of tumor hypoxia. In addition, there were minimal changes over time upon probe placement and repeated measurement, indicating that the pressure-induced changes were minimal and repeated measurements did not differ significantly from the initial value. This study demonstrates the feasibility of conducting optical spectroscopy measurements on intact lesions prior to removal during HNSCC procedures, and established that this probe provides diagnostically-relevant physiologic information that may impact further treatment.
- 24 February 2023
- Published by MDPI AG in Current Oncology
- Vol. 30 (3) , 2751-2760
Open AccessA Clinical Study to Assess Diffuse Reflectance Spectroscopy with an Auto-Calibrated, Pressure-Sensing Optical Probe in Head and Neck Cancer
Diffuse reflectance spectroscopy (DRS) is a powerful tool for quantifying optical and physiological tissue properties such as hemoglobin oxygen saturation and vascularity. DRS is increasingly used clinically for distinguishing cancerous lesions from normal tissue. However, its widespread clinical acceptance is still limited due to uncontrolled probe–tissue interface pressure that influences reproducibility and introduces operator-dependent results. In this clinical study, we assessed and validated a pressure-sensing and automatic self-calibration DRS in patients with suspected head and neck squamous cell carcinoma (HNSCC). The clinical study enrolled nineteen patients undergoing HNSCC surgical biopsy procedures. Patients consented to evaluation of this improved DRS system during surgery. For each patient, we obtained 10 repeated measurements on one tumor site and one distant normal location. Using a Monte Carlo-based model, we extracted the hemoglobin saturation data along with total hemoglobin content and scattering properties. A total of twelve cancer tissue samples from HNSCC patients and fourteen normal tissues were analyzed. A linear mixed effects model tested for significance between repeated measurements and compared tumor versus normal tissue. These results demonstrate that cancerous tissues have a significantly lower hemoglobin saturation compared to normal controls (p < 0.001), which may be reflective of tumor hypoxia. In addition, there were minimal changes over time upon probe placement and repeated measurement, indicating that the pressure-induced changes were minimal and repeated measurements did not differ significantly from the initial value. This study demonstrates the feasibility of conducting optical spectroscopy measurements on intact lesions prior to removal during HNSCC procedures, and established that this probe provides diagnostically-relevant physiologic information that may impact further treatment.
- Open Access
- 4 January 2021
- Published by Ubiquity Press, Ltd. in Annals of Global Health
- Vol. 87 (1) , 116
Policy Considerations to Promote Equitable Cervical Cancer Screening and Treatment in Peru
Cervical cancer is one of the leading causes of death among Peruvian women. Women seeking screening or treatment services experience delays in receiving screening results provided at community clinics or district hospitals, and lack sufficient resources to pay out-of-pocket to travel to the capital city of Lima for specialized treatment. Continued disparities in health outcomes and systemic barriers to accessing services suggest there are gaps between policy measures and implementation. We aim to understand why national policies and clinical pathways that are aligned to global standards have been insufficient in improving cervical cancer screening and treatment in Peru, particularly among women who experience systemic exclusion from health services. We conducted a policy analysis based on a literature review (2005–2020), in Spanish and English, on PubMed, Global Health, Scopus, EconLit, Lilacs, and Scielo using a value-based care framework. The main barriers included unequal distribution of health infrastructure and health care workforce, and differences in access to health insurance. Additional barriers, including limited political will and support, limit efforts to prioritize the implementation of cervical cancer policies. We propose policy considersations in redesigning payment models, expanding healthcare workforce, generating costing and policy evidence, and reviewing policies for point-of-care technologies. The barriers identified in this literature review are applicable not only to cervical cancer care, but to primary health care in Peru. Systematic policy changes that address root causes of health inequities and are implemented at scale are needed to advance health reform efforts.
- 4 January 2021
- Published by Ubiquity Press, Ltd. in Annals of Global Health
- Vol. 87 (1) , 116
Open AccessPolicy Considerations to Promote Equitable Cervical Cancer Screening and Treatment in Peru
Cervical cancer is one of the leading causes of death among Peruvian women. Women seeking screening or treatment services experience delays in receiving screening results provided at community clinics or district hospitals, and lack sufficient resources to pay out-of-pocket to travel to the capital city of Lima for specialized treatment. Continued disparities in health outcomes and systemic barriers to accessing services suggest there are gaps between policy measures and implementation. We aim to understand why national policies and clinical pathways that are aligned to global standards have been insufficient in improving cervical cancer screening and treatment in Peru, particularly among women who experience systemic exclusion from health services. We conducted a policy analysis based on a literature review (2005–2020), in Spanish and English, on PubMed, Global Health, Scopus, EconLit, Lilacs, and Scielo using a value-based care framework. The main barriers included unequal distribution of health infrastructure and health care workforce, and differences in access to health insurance. Additional barriers, including limited political will and support, limit efforts to prioritize the implementation of cervical cancer policies. We propose policy considersations in redesigning payment models, expanding healthcare workforce, generating costing and policy evidence, and reviewing policies for point-of-care technologies. The barriers identified in this literature review are applicable not only to cervical cancer care, but to primary health care in Peru. Systematic policy changes that address root causes of health inequities and are implemented at scale are needed to advance health reform efforts.
- Open Access
A Novel, Versatile Speculum-free Callascope for Clinical Examination and Self-Visualization of the Cervix
Background: Invasive cervical cancer is preventable, yet affects 500,000 women worldwide each year, and over half these women die. Barriers to cervical cancer screening include lack of awareness of cervical cancer and the cervix, fear of the speculum, and lack of women-centric technologies. We developed a low-cost (∼$50), cervix-imaging device called the Callascope, which comprises an imaging component, camera and inserter that eliminates the need for a speculum and enables self-insertion. We sought to assess the quality of physicians’ images of the cervix using the Callascope versus the speculum in live patients and study women’s willingness to independently use the Callascope to image their cervix. Methods: We conducted two main studies: (1) a clinical study in which a physician imaged the cervix of patients using both the speculum and Callascope in a 2×2 crossover design; and (2) home-based self-cervix imaging with the Callascope. Results: Participants of the clinical study (n=28) and home study (n=12) all indicated greater comfort and an overall preference for the Callascope over the speculum. The clinical study data indicated that the Callascope enabled similar visualization compared to the speculum while significantly improving patient experience. With physician insertion and manipulation, the Callascope enabled cervix visualization for 82% of participants. In the home-study, 83% of participants were able to visualize their cervix with the Callascope on the first try and 100% after multiple attempts. Conclusion: The Callascope is more comfortable and provides similar visualization to the speculum. The Callascope can be used by medical providers for clinical exams while also enabling home self-screening for cervical cancer and promoting a better understanding of one’s cervix to increase awareness of cervical screening needs. The Callascope may increase cervical cancer screening rates through reducing barriers including cost, discomfort, lack of awareness and stigma.
Open AccessA Novel, Versatile Speculum-free Callascope for Clinical Examination and Self-Visualization of the Cervix
Background: Invasive cervical cancer is preventable, yet affects 500,000 women worldwide each year, and over half these women die. Barriers to cervical cancer screening include lack of awareness of cervical cancer and the cervix, fear of the speculum, and lack of women-centric technologies. We developed a low-cost (∼$50), cervix-imaging device called the Callascope, which comprises an imaging component, camera and inserter that eliminates the need for a speculum and enables self-insertion. We sought to assess the quality of physicians’ images of the cervix using the Callascope versus the speculum in live patients and study women’s willingness to independently use the Callascope to image their cervix. Methods: We conducted two main studies: (1) a clinical study in which a physician imaged the cervix of patients using both the speculum and Callascope in a 2×2 crossover design; and (2) home-based self-cervix imaging with the Callascope. Results: Participants of the clinical study (n=28) and home study (n=12) all indicated greater comfort and an overall preference for the Callascope over the speculum. The clinical study data indicated that the Callascope enabled similar visualization compared to the speculum while significantly improving patient experience. With physician insertion and manipulation, the Callascope enabled cervix visualization for 82% of participants. In the home-study, 83% of participants were able to visualize their cervix with the Callascope on the first try and 100% after multiple attempts. Conclusion: The Callascope is more comfortable and provides similar visualization to the speculum. The Callascope can be used by medical providers for clinical exams while also enabling home self-screening for cervical cancer and promoting a better understanding of one’s cervix to increase awareness of cervical screening needs. The Callascope may increase cervical cancer screening rates through reducing barriers including cost, discomfort, lack of awareness and stigma.
- 15 May 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 23 (05) , 057004-8
Assessing effects of pressure on tumor and normal tissue physiology using an automated self-calibrated, pressure-sensing probe for diffuse reflectance spectroscopy
Diffuse reflectance spectroscopy (DRS) represents a quantitative, noninvasive, nondestructive means of assessing vascular oxygenation, vascularity, and structural properties. However, it is known that such measurements can be influenced by the effects of pressure, which is a major concern for reproducible and operator-independent assessment of tissues. Second, regular calibration is a necessary component of quantitative DRS to account for factors such as lamp decay and fiber bending. Without a means of reliably controlling for these factors, the accuracy of any such assessments will be reduced, and potentially biased. To address these issues, a self-calibrating, pressure-controlled DRS system is described and applied to both a patient-derived xenograft glioma model, as well as a set of healthy volunteers for assessments of oral mucosal tissues. It was shown that pressure had a significant effect on the derived optical parameters, and that the effects on the optical parameters were magnified with increasing time and pressure levels. These findings indicate that not only is it critical to integrate a pressure sensor into a DRS device, but that it is also important to do so in an automated way to trigger a measurement as soon as possible after probe contact is made to minimize the perturbation to the tissue site.
- 15 May 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 23 (05) , 057004-8
Assessing effects of pressure on tumor and normal tissue physiology using an automated self-calibrated, pressure-sensing probe for diffuse reflectance spectroscopy
Diffuse reflectance spectroscopy (DRS) represents a quantitative, noninvasive, nondestructive means of assessing vascular oxygenation, vascularity, and structural properties. However, it is known that such measurements can be influenced by the effects of pressure, which is a major concern for reproducible and operator-independent assessment of tissues. Second, regular calibration is a necessary component of quantitative DRS to account for factors such as lamp decay and fiber bending. Without a means of reliably controlling for these factors, the accuracy of any such assessments will be reduced, and potentially biased. To address these issues, a self-calibrating, pressure-controlled DRS system is described and applied to both a patient-derived xenograft glioma model, as well as a set of healthy volunteers for assessments of oral mucosal tissues. It was shown that pressure had a significant effect on the derived optical parameters, and that the effects on the optical parameters were magnified with increasing time and pressure levels. These findings indicate that not only is it critical to integrate a pressure sensor into a DRS device, but that it is also important to do so in an automated way to trigger a measurement as soon as possible after probe contact is made to minimize the perturbation to the tissue site.