CPCarlos A.C. Pedra

Carlos A.C. Pedra

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Carlos A.C. Pedra has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Double balloon pulmonary valvuloplasty: Multi‐track system versus conventional technique

    by Carlos A.C. Pedra, S. Raul Arrieta, Cesar A. Esteves, Sérgio L.N. Braga, Juliana Neves, Renata Cassar, Simone R.F. Pedra, M. Virginia T. Santana, M. Aparecida P. Silva, J. Eduardo M.R. Sousa, et al.

    Objectives: To evaluate whether double balloon pulmonary valvuloplasty (DBPV) with the Multi‐Track system (MTS) may help to simplify the procedure. Background: DBPV is usually required for patients with pulmonary valve stenosis with large annulus. However, it needs two venous accesses and can be technically demanding. Methods: From 07/03, 20 consecutive patients (19 ± 10 yrs) with typical pulmonary valve stenosis underwent DBPV using the MTS (G1). The results were compared with those achieved by conventional DBPV performed in a matched historical group of 28 patients (21 ± 11 yrs; P = NS) (G2). Results: MTS balloons were easily advanced through the skin and inflated across the valve. Similar results were observed in regards to residual gradients (12 ± 11 vs 14 ± 10 mm Hg; P = NS) and right ventricular to systemic pressures (0.35 ± 0.22 vs 0.37 ± 0.26; P = NS). Procedure and fluoroscopic times were significant lower in G1 (78 ± 24 vs 126 ± 28; 15 ± 12 vs 25 ± 8 min, respectively; both P < 0.001). There was no major complication. Median follow‐up was 1.8 yr for G1 and 5 yr for G2 (P = 0.037). At the last visit, peak instantaneous gradient across the right ventricular outflow tract by echocardiography was a mean 22 ± 10 mm Hg for G1 and 25 ± 9 mm Hg for G2 (P = NS). No patient had severe pulmonary insufficiency or required reintervention. Conclusions: The use of the MTS helped to expedite the procedure providing satisfactory midterm clinical outcomes, similar to those observed with the conventional DBPV technique.


  • Use of Covered Stents in the Management of Coarctation of the Aorta

    by C.A.C. Pedra, V.F. Fontes, C.A. Esteves, S.R. Arrieta, S.L.N. Braga, H. Justino, A.M. Kambara, S.M. Moreira, J.E.R. Sousa

    We report our experience with the use of covered stents for the management of coarctation of the aorta. From December 2001 to March 2004, nine patients (seven males; median age, 31 years; mean weight, 65 ± 15 kg) underwent implantation. Indications included critical or atretic native coarctation (n = 4), patients >50 years of age (n = 2), associated patent ductus arteriosus (n = 1) or adjacent aneurysm (n = 1), and the presence of a circumferential fracture within a previously implanted stent (n = 1). The covered balloon-expandable Cheatham-Platinum stent and the self-expandable stent graft Braile were employed. Adequate implantation was observed in all patients. Gradients were reduced from 54 ± 14 to 3 ± 8 mmHg and the coarctation site increased from 2.4 ± 2.9 to 15.9 ± 4.3 mm. The patent ductus arteriosus was immediately closed and the aneurysm excluded. Two patients >35 years with aneurysmal ascending aorta and metallic aortic prosthesis had aneurysm formation at follow-up, with one undergoing aneurysm exclusion using a Braile stent. Although covered stents are useful in the management of selected patients with coarctation, aneurysm formation may still occur in patients with markers of aortic wall weakness. Refinements in the deployment technique and/or the stent design are needed to eliminate this risk.