Carlos A.C. Pedra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Carlos A.C. Pedra has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
A.M. Kambara
Instituto Dante Pazzanese de Cardiologia
1 shared publicationC.A. Esteves
Instituto Dante Pazzanese de Cardiologia
1 shared publicationCesar A. Esteves
Instituto Dante Pazzanese de Cardiologia, São Paulo, SP, Brazil
1 shared publication- Henri Justino
Texas Children’s Hospital
1 shared publication J. Eduardo M.R. Sousa
Instituto Dante Pazzanese de Cardiologia, São Paulo, SP, Brazil
1 shared publicationJ.E.R. Sousa
Instituto Dante Pazzanese de Cardiologia
1 shared publication
Latest Publications
- 30 June 2006
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 68 (2) , 193-198
Double balloon pulmonary valvuloplasty: Multi‐track system versus conventional technique
Objectives: To evaluate whether double balloon pulmonary valvuloplasty (DBPV) with the Multi‐Track system (MTS) may help to simplify the procedure. Background: DBPV is usually required for patients with pulmonary valve stenosis with large annulus. However, it needs two venous accesses and can be technically demanding. Methods: From 07/03, 20 consecutive patients (19 ± 10 yrs) with typical pulmonary valve stenosis underwent DBPV using the MTS (G1). The results were compared with those achieved by conventional DBPV performed in a matched historical group of 28 patients (21 ± 11 yrs; P = NS) (G2). Results: MTS balloons were easily advanced through the skin and inflated across the valve. Similar results were observed in regards to residual gradients (12 ± 11 vs 14 ± 10 mm Hg; P = NS) and right ventricular to systemic pressures (0.35 ± 0.22 vs 0.37 ± 0.26; P = NS). Procedure and fluoroscopic times were significant lower in G1 (78 ± 24 vs 126 ± 28; 15 ± 12 vs 25 ± 8 min, respectively; both P < 0.001). There was no major complication. Median follow‐up was 1.8 yr for G1 and 5 yr for G2 (P = 0.037). At the last visit, peak instantaneous gradient across the right ventricular outflow tract by echocardiography was a mean 22 ± 10 mm Hg for G1 and 25 ± 9 mm Hg for G2 (P = NS). No patient had severe pulmonary insufficiency or required reintervention. Conclusions: The use of the MTS helped to expedite the procedure providing satisfactory midterm clinical outcomes, similar to those observed with the conventional DBPV technique.
- 30 June 2006
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 68 (2) , 193-198
Double balloon pulmonary valvuloplasty: Multi‐track system versus conventional technique
Objectives: To evaluate whether double balloon pulmonary valvuloplasty (DBPV) with the Multi‐Track system (MTS) may help to simplify the procedure. Background: DBPV is usually required for patients with pulmonary valve stenosis with large annulus. However, it needs two venous accesses and can be technically demanding. Methods: From 07/03, 20 consecutive patients (19 ± 10 yrs) with typical pulmonary valve stenosis underwent DBPV using the MTS (G1). The results were compared with those achieved by conventional DBPV performed in a matched historical group of 28 patients (21 ± 11 yrs; P = NS) (G2). Results: MTS balloons were easily advanced through the skin and inflated across the valve. Similar results were observed in regards to residual gradients (12 ± 11 vs 14 ± 10 mm Hg; P = NS) and right ventricular to systemic pressures (0.35 ± 0.22 vs 0.37 ± 0.26; P = NS). Procedure and fluoroscopic times were significant lower in G1 (78 ± 24 vs 126 ± 28; 15 ± 12 vs 25 ± 8 min, respectively; both P < 0.001). There was no major complication. Median follow‐up was 1.8 yr for G1 and 5 yr for G2 (P = 0.037). At the last visit, peak instantaneous gradient across the right ventricular outflow tract by echocardiography was a mean 22 ± 10 mm Hg for G1 and 25 ± 9 mm Hg for G2 (P = NS). No patient had severe pulmonary insufficiency or required reintervention. Conclusions: The use of the MTS helped to expedite the procedure providing satisfactory midterm clinical outcomes, similar to those observed with the conventional DBPV technique.
- 15 September 2004
- Published by Springer Nature in Pediatric Cardiology
- Vol. 26 (4) , 431-439
Use of Covered Stents in the Management of Coarctation of the Aorta
We report our experience with the use of covered stents for the management of coarctation of the aorta. From December 2001 to March 2004, nine patients (seven males; median age, 31 years; mean weight, 65 ± 15 kg) underwent implantation. Indications included critical or atretic native coarctation (n = 4), patients >50 years of age (n = 2), associated patent ductus arteriosus (n = 1) or adjacent aneurysm (n = 1), and the presence of a circumferential fracture within a previously implanted stent (n = 1). The covered balloon-expandable Cheatham-Platinum stent and the self-expandable stent graft Braile were employed. Adequate implantation was observed in all patients. Gradients were reduced from 54 ± 14 to 3 ± 8 mmHg and the coarctation site increased from 2.4 ± 2.9 to 15.9 ± 4.3 mm. The patent ductus arteriosus was immediately closed and the aneurysm excluded. Two patients >35 years with aneurysmal ascending aorta and metallic aortic prosthesis had aneurysm formation at follow-up, with one undergoing aneurysm exclusion using a Braile stent. Although covered stents are useful in the management of selected patients with coarctation, aneurysm formation may still occur in patients with markers of aortic wall weakness. Refinements in the deployment technique and/or the stent design are needed to eliminate this risk.
- 15 September 2004
- Published by Springer Nature in Pediatric Cardiology
- Vol. 26 (4) , 431-439
Use of Covered Stents in the Management of Coarctation of the Aorta
We report our experience with the use of covered stents for the management of coarctation of the aorta. From December 2001 to March 2004, nine patients (seven males; median age, 31 years; mean weight, 65 ± 15 kg) underwent implantation. Indications included critical or atretic native coarctation (n = 4), patients >50 years of age (n = 2), associated patent ductus arteriosus (n = 1) or adjacent aneurysm (n = 1), and the presence of a circumferential fracture within a previously implanted stent (n = 1). The covered balloon-expandable Cheatham-Platinum stent and the self-expandable stent graft Braile were employed. Adequate implantation was observed in all patients. Gradients were reduced from 54 ± 14 to 3 ± 8 mmHg and the coarctation site increased from 2.4 ± 2.9 to 15.9 ± 4.3 mm. The patent ductus arteriosus was immediately closed and the aneurysm excluded. Two patients >35 years with aneurysmal ascending aorta and metallic aortic prosthesis had aneurysm formation at follow-up, with one undergoing aneurysm exclusion using a Braile stent. Although covered stents are useful in the management of selected patients with coarctation, aneurysm formation may still occur in patients with markers of aortic wall weakness. Refinements in the deployment technique and/or the stent design are needed to eliminate this risk.