Clara Phillips
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Clara Phillips has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Fae Azhari
University of Toronto
4 shared publications - Arezoo Eshraghi
West Park Healthcare Centre, University Health Network, Toronto, Ontario, Canada
3 shared publications - Crystal MacKay
Affiliations Faculty of Health Sciences, School of Rehabilitation Therapy, Queen’s University, Kingston, Ontario, Canada, Kite Research Institute, University Health Network, Toronto, Ontario, Canada, Department of Physical Therapy, University of Toronto, Toronto, Ontario, Canada
3 shared publications - Winfried Heim
University Health Network, Toronto, Ontario, Canada
3 shared publications - Mark Timothy Kortschot
University of Toronto
2 shared publications - Steven Dilkas
1) Temerty Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada; 2) West Park Healthcare Centre, University Health Network, Toronto, Ontario, Canada
2 shared publications
Latest Publications
- Open Access
- 2 November 2026
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 147 (11) , 115010
A quasi-static gait simulator for testing transtibial prostheses: taking steps while standing still
- 2 November 2026
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 147 (11) , 115010
Open AccessA quasi-static gait simulator for testing transtibial prostheses: taking steps while standing still
- Open Access
- 19 May 2026
- Published by Elsevier in SSRN Electronic Journal
A Gait Simulator for Testing Transtibial Prostheses: Taking Steps While Standing Still
We present a novel gait simulator designed for lab-based testing of transtibial prosthetic sockets. Existing simulators are generally based on complex, expensive treadmill systems. Using the well understood kinetics of gait, we propose a pylon-stationary simulator that uses three electro-pneumatic actuators to replicate the forces and moments experienced by a transtibial prothesis during gait while holding the prosthesis relatively still. We verified the simulator’s ability to reproduce specific and general walking gait loads applied to a prosthetic socket using both rigid and compliant mock residual limbs. The simulator accurately replicates vertical and horizontal forces and sagittal plane moments at frequencies up to 0.2 Hz. However, the simulator struggles to replicate sagittal plane moments at higher frequencies, particularly when the socket is highly compliant or poorly fitted. Internal force and moment measurements showed inaccuracies in the presence of large displacements associated with rocking or pistoning, highlighting areas for improvement. Despite its limitations, the proposed simulator provides a versatile and affordable tool for assessing prosthetic socket fit and performance. Future improvements, including enhanced sensor integration, more advanced control schemes, and a user-friendly interface, will expand its utility and impact.
- 19 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Gait Simulator for Testing Transtibial Prostheses: Taking Steps While Standing Still
We present a novel gait simulator designed for lab-based testing of transtibial prosthetic sockets. Existing simulators are generally based on complex, expensive treadmill systems. Using the well understood kinetics of gait, we propose a pylon-stationary simulator that uses three electro-pneumatic actuators to replicate the forces and moments experienced by a transtibial prothesis during gait while holding the prosthesis relatively still. We verified the simulator’s ability to reproduce specific and general walking gait loads applied to a prosthetic socket using both rigid and compliant mock residual limbs. The simulator accurately replicates vertical and horizontal forces and sagittal plane moments at frequencies up to 0.2 Hz. However, the simulator struggles to replicate sagittal plane moments at higher frequencies, particularly when the socket is highly compliant or poorly fitted. Internal force and moment measurements showed inaccuracies in the presence of large displacements associated with rocking or pistoning, highlighting areas for improvement. Despite its limitations, the proposed simulator provides a versatile and affordable tool for assessing prosthetic socket fit and performance. Future improvements, including enhanced sensor integration, more advanced control schemes, and a user-friendly interface, will expand its utility and impact.
- Open Access
- 10 September 2025
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 8 (2) , 45759
A BIOFIDELIC MOCK RESIDUAL LIMB FOR PROSTHETIC SOCKET TESTING
BACKGROUND: Evaluating prosthetic socket fit and function relies on accurately simulating load transfer between the residual limb and the socket. This limb can be either real (of a study participant) or a mock residual limb that simulates in vivo properties. Mock limbs minimize reliance on resource-intensive clinical trials; however, most are static in size, limiting their use in testing clinical outcomes like socket adjustability. OBJECTIVE: To design and validate a biofidelic mock limb, capable of real-time, controllable volume adjustments of up to ±5% limb volume. METHODOLOGY: Water-filled bladders were embedded within a transtibial residual limb model made of a dual-durometer urethane composition, mimicking deep and soft tissue. An Arduino-controlled syringe system was used to actuate volume adjustments. The method was validated through repeatability tests at different rates of volume change, cycling through expansion, holding at maximum volume, and contraction. Volume change was quantified by measuring interfacial pressures between the limb and a static socket. FINDINGS: The limb was fabricated with readily available materials for less than CAD 400. Volume change rate had minimal effect on interfacial pressure throughout the testing cycle, and minimal hysteresis was found between expansion and contraction periods. Repeatability was high, with a coefficient of variation of normalized pressure remaining below 10.4% over three repeated tests. CONCLUSION: The proposed biofidelic limb was validated for its ability to mimic volume change in a transtibial residual limb. The design enables easy replication or customization to simulate different limb physiologies and anatomies. The limb allows for controllable bench-top testing during prototyping of adjustable sockets or other devices, thus bringing devices to clinical use sooner. Layman's Abstract For individuals with a lower-limb amputation, their prosthetic socket—the component that connects their residual limb to the prosthesis—needs to fit well to be comfortable and to function properly. However, the size of a residual limb can change throughout the day due to factors like activity and diet, which can affect the socket fit. Evaluating how prosthetic sockets adapt to residual limb volume changes is important, but doing so through clinical testing with human participants requires extensive resources and involves test conditions that are hard to control. A “mock” residual limb was introduced that simulated real-time, controllable limb volume changes, reducing the need for amputee participants in prosthetic socket testing. The mock limb used water-filled bladders within a soft urethane composition, and the bladder size was controlled by a motorized syringe system, allowing it to expand or contract by up to 5%. The limb’s ability to reliably repeat its volume changes was validated. This tool can help researchers quickly test adjustable prosthetic sockets and other wearable devices in a lab setting, thereby accelerating device development and reducing dependence on clinical testing. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/45759/34271 How To Cite: Phillips C, Nagpal A, Azhari F. A biofidelic mock residual limb for prosthetic socket testing. Canadian Prosthetics & Orthotics Journal. 2025; Volume 8, Issue 2, No. 1. DOI:10.33137/cpoj.v8i1.45759 Corresponding Author: Fae Azhari, PhDAffiliation: Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Canada.E-Mail: fae.azhari@utoronto.caORCID ID: https://orcid.org/0000-0003-2559-8566
- 10 September 2025
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 8 (2) , 45759
Open AccessA BIOFIDELIC MOCK RESIDUAL LIMB FOR PROSTHETIC SOCKET TESTING
BACKGROUND: Evaluating prosthetic socket fit and function relies on accurately simulating load transfer between the residual limb and the socket. This limb can be either real (of a study participant) or a mock residual limb that simulates in vivo properties. Mock limbs minimize reliance on resource-intensive clinical trials; however, most are static in size, limiting their use in testing clinical outcomes like socket adjustability. OBJECTIVE: To design and validate a biofidelic mock limb, capable of real-time, controllable volume adjustments of up to ±5% limb volume. METHODOLOGY: Water-filled bladders were embedded within a transtibial residual limb model made of a dual-durometer urethane composition, mimicking deep and soft tissue. An Arduino-controlled syringe system was used to actuate volume adjustments. The method was validated through repeatability tests at different rates of volume change, cycling through expansion, holding at maximum volume, and contraction. Volume change was quantified by measuring interfacial pressures between the limb and a static socket. FINDINGS: The limb was fabricated with readily available materials for less than CAD 400. Volume change rate had minimal effect on interfacial pressure throughout the testing cycle, and minimal hysteresis was found between expansion and contraction periods. Repeatability was high, with a coefficient of variation of normalized pressure remaining below 10.4% over three repeated tests. CONCLUSION: The proposed biofidelic limb was validated for its ability to mimic volume change in a transtibial residual limb. The design enables easy replication or customization to simulate different limb physiologies and anatomies. The limb allows for controllable bench-top testing during prototyping of adjustable sockets or other devices, thus bringing devices to clinical use sooner. Layman's Abstract For individuals with a lower-limb amputation, their prosthetic socket—the component that connects their residual limb to the prosthesis—needs to fit well to be comfortable and to function properly. However, the size of a residual limb can change throughout the day due to factors like activity and diet, which can affect the socket fit. Evaluating how prosthetic sockets adapt to residual limb volume changes is important, but doing so through clinical testing with human participants requires extensive resources and involves test conditions that are hard to control. A “mock” residual limb was introduced that simulated real-time, controllable limb volume changes, reducing the need for amputee participants in prosthetic socket testing. The mock limb used water-filled bladders within a soft urethane composition, and the bladder size was controlled by a motorized syringe system, allowing it to expand or contract by up to 5%. The limb’s ability to reliably repeat its volume changes was validated. This tool can help researchers quickly test adjustable prosthetic sockets and other wearable devices in a lab setting, thereby accelerating device development and reducing dependence on clinical testing. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/45759/34271 How To Cite: Phillips C, Nagpal A, Azhari F. A biofidelic mock residual limb for prosthetic socket testing. Canadian Prosthetics & Orthotics Journal. 2025; Volume 8, Issue 2, No. 1. DOI:10.33137/cpoj.v8i1.45759 Corresponding Author: Fae Azhari, PhDAffiliation: Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Canada.E-Mail: fae.azhari@utoronto.caORCID ID: https://orcid.org/0000-0003-2559-8566
- Open Access
- 21 February 2025
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 8 (1)
PROSTHETIC TREATMENT OF WOMEN WITH LOWER LIMB ABSENCE DURING PREGNANCY & THE POSTPARTUM PERIOD: A CHART REVIEW
BACKGROUND: Little information is available for women with lower limb absence (LLA) and their prosthetists regarding expectations for prosthetic treatment during and after pregnancy. A main concern is prosthesis use and what adjustments may be required to sustain mobility. OBJECTIVES: This study examines the prosthetic treatment of women with LLA to understand what specific prosthetic interventions occurred during the perinatal period and to gather information from the prosthetists regarding key learnings to be shared with others. METHODOLOGY: This study was a retrospective review of clinical records for women with LLA who received prosthetic care across Canada. Between January – May 2023, all 19 women who participated in a previous study on LLA and pregnancy consented to have their prosthetist contacted. Prosthetists were asked to complete a structured survey documenting appointment details, socket and alignment adjustments made during the perinatal period and key learnings in providing care to this population. FINDINGS: 15 prosthetists were contacted to complete surveys for the 19 participants. Reviews of clinical records were completed between April – August 2023 by 7 prosthetists covering 18 pregnancies from 11 women with LLA (two bilateral transtibial, two unilateral transtibial, four unilateral transfemoral, and three unilateral rotationplasty). Socket adjustments were required in 11/18 pregnancies with common methods including circumferential stretching and localized adjustments. Alignment adjustments to existing sockets were only required in two pregnancies. Additional sockets were required in six pregnancies when the existing socket could no longer be adjusted to achieve comfort, most often during the first six months of pregnancy (the first or second trimester). Everyone who had a socket adjustment during pregnancy required additional socket adjustments or new sockets in the postpartum period. Prosthetists observed wide variations in physiological changes and prosthetic fit during the perinatal period and shared prosthetic management techniques to address residual limb volume changes. A data collection framework was also proposed to support the ongoing collection of this data to include a wider diversity of women and experiences. CONCLUSION: A wide range of prosthetic treatment interventions may occur during pregnancy and the postpartum period. While prosthetists and women with LLA can anticipate that socket and alignment changes may be necessary, sometimes none are required. By preparing for potential fluctuations in prosthetic fit and addressing each individual's needs, prosthetists can help minimize disruptions to mobility throughout pregnancy. Layman's Abstract When women with lower limb absence become pregnant, they often have a lot of questions about what to expect during their pregnancy, particularly in regard to their prosthesis use and mobility. There is very little information available regarding this, leaving women and their prosthetists with many unanswered questions. We sought to address this gap by gathering information on the details surrounding prosthetic treatment during pregnancy and the postpartum period. Women who participated in a previous study provided consent to contact the prosthetist who had provided care to them during and after pregnancy. We asked prosthetists to complete a structured survey using the details written in their clinical records. They documented any adjustments made to the prosthesis, if new sockets were required, and key learnings from their experience. Results from 18 pregnancies and 11 women with transtibial, transfemoral, and rotationplasty amputations were included. There was a wide range of experiences, including some women needing no adjustments and others requiring substantial adjustments and/or new sockets, both during and after pregnancy. This information demonstrates the variety of experiences women can have and allows women and prosthetists plan for the different possibilities they may encounter during and after pregnancy. We also provide a data collection framework to support the ongoing collection of this data in the future to include a wider diversity of women and experiences. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/45142/34057 How To Cite: Pousett B.M, Cumming D, Phillips C, Azhari F, MacKay C. Prosthetic treatment of women with lower limb absence during pregnancy & the postpartum period: A chart review. Canadian Prosthetics & Orthotics Journal. 2025; Volume 8, Issue 1, No. 7. Https://doi.org/10.33137/cpoj.v8i1.45142 Corresponding Author: Brittany Mae Pousett, CP(c), MSc.Affiliations: 1) Barber Prosthetics Clinic, Vancouver, Canada; 2) Rehabilitation Sciences, Faculty of Medicine, University of British Columbia, Vancouver, Canada.ORCID ID: Https://orcid.org/0000-0002-2272-7847E-Mail: brittany@pousett.caTelephone: (604) 321-1115
- 21 February 2025
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 8 (1)
Open AccessPROSTHETIC TREATMENT OF WOMEN WITH LOWER LIMB ABSENCE DURING PREGNANCY & THE POSTPARTUM PERIOD: A CHART REVIEW
BACKGROUND: Little information is available for women with lower limb absence (LLA) and their prosthetists regarding expectations for prosthetic treatment during and after pregnancy. A main concern is prosthesis use and what adjustments may be required to sustain mobility. OBJECTIVES: This study examines the prosthetic treatment of women with LLA to understand what specific prosthetic interventions occurred during the perinatal period and to gather information from the prosthetists regarding key learnings to be shared with others. METHODOLOGY: This study was a retrospective review of clinical records for women with LLA who received prosthetic care across Canada. Between January – May 2023, all 19 women who participated in a previous study on LLA and pregnancy consented to have their prosthetist contacted. Prosthetists were asked to complete a structured survey documenting appointment details, socket and alignment adjustments made during the perinatal period and key learnings in providing care to this population. FINDINGS: 15 prosthetists were contacted to complete surveys for the 19 participants. Reviews of clinical records were completed between April – August 2023 by 7 prosthetists covering 18 pregnancies from 11 women with LLA (two bilateral transtibial, two unilateral transtibial, four unilateral transfemoral, and three unilateral rotationplasty). Socket adjustments were required in 11/18 pregnancies with common methods including circumferential stretching and localized adjustments. Alignment adjustments to existing sockets were only required in two pregnancies. Additional sockets were required in six pregnancies when the existing socket could no longer be adjusted to achieve comfort, most often during the first six months of pregnancy (the first or second trimester). Everyone who had a socket adjustment during pregnancy required additional socket adjustments or new sockets in the postpartum period. Prosthetists observed wide variations in physiological changes and prosthetic fit during the perinatal period and shared prosthetic management techniques to address residual limb volume changes. A data collection framework was also proposed to support the ongoing collection of this data to include a wider diversity of women and experiences. CONCLUSION: A wide range of prosthetic treatment interventions may occur during pregnancy and the postpartum period. While prosthetists and women with LLA can anticipate that socket and alignment changes may be necessary, sometimes none are required. By preparing for potential fluctuations in prosthetic fit and addressing each individual's needs, prosthetists can help minimize disruptions to mobility throughout pregnancy. Layman's Abstract When women with lower limb absence become pregnant, they often have a lot of questions about what to expect during their pregnancy, particularly in regard to their prosthesis use and mobility. There is very little information available regarding this, leaving women and their prosthetists with many unanswered questions. We sought to address this gap by gathering information on the details surrounding prosthetic treatment during pregnancy and the postpartum period. Women who participated in a previous study provided consent to contact the prosthetist who had provided care to them during and after pregnancy. We asked prosthetists to complete a structured survey using the details written in their clinical records. They documented any adjustments made to the prosthesis, if new sockets were required, and key learnings from their experience. Results from 18 pregnancies and 11 women with transtibial, transfemoral, and rotationplasty amputations were included. There was a wide range of experiences, including some women needing no adjustments and others requiring substantial adjustments and/or new sockets, both during and after pregnancy. This information demonstrates the variety of experiences women can have and allows women and prosthetists plan for the different possibilities they may encounter during and after pregnancy. We also provide a data collection framework to support the ongoing collection of this data in the future to include a wider diversity of women and experiences. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/45142/34057 How To Cite: Pousett B.M, Cumming D, Phillips C, Azhari F, MacKay C. Prosthetic treatment of women with lower limb absence during pregnancy & the postpartum period: A chart review. Canadian Prosthetics & Orthotics Journal. 2025; Volume 8, Issue 1, No. 7. Https://doi.org/10.33137/cpoj.v8i1.45142 Corresponding Author: Brittany Mae Pousett, CP(c), MSc.Affiliations: 1) Barber Prosthetics Clinic, Vancouver, Canada; 2) Rehabilitation Sciences, Faculty of Medicine, University of British Columbia, Vancouver, Canada.ORCID ID: Https://orcid.org/0000-0002-2272-7847E-Mail: brittany@pousett.caTelephone: (604) 321-1115
- Open Access
- 14 June 2024
- Published by MDPI AG in Prosthesis
- Vol. 6 (3) , 672-682
Comparison of Socket Geometry, Socket Comfort, and Patient Experience between Manually- and Digitally-Designed Prosthetic Sockets for Lower-Limb Amputees: A Feasibility Study
Prosthetic socket manufacturing is experiencing a revolutionary shift towards using digital methods, such as 3D scanning and 3D printing. However, using digital methods requires the clinician to transfer their skills from making sockets by hand to making sockets with a computer. This shift in practice may change the socket geometry and fit; however, to what extent is unknown. Thus, the aim of this study was to explore the feasibility of analyzing geometric and clinical differences between digitally- and manually-designed sockets. Nine adult inpatients with below-knee amputation were recruited. Two sockets were 3D printed for each participant from 3D socket models that were developed from: (1) 3D scanning a manually-modified hand-casted positive mold of the residuum; and (2) a digitally-modified 3D scan of the residuum. Manual and digital procedures were compared for three measures: final socket geometry, the Socket Comfort Score, and a patient experience survey. Feasibility data were collected to measure protocol implementation fidelity to inform a future larger study. These data revealed that 89% of participants followed the intended protocol, no participants dropped out, and only one adverse event was report. As no significant geometric differences were found and participants experienced similar comfort scores between manually- and digitally-designed sockets, study feasibility was determined to be successful. Thus, a randomized control trial study will be conducted to draw statistically relevant conclusions from these outcome measures that may provide meaningful information for improving digital design procedures.
- 14 June 2024
- Published by MDPI AG in Prosthesis
- Vol. 6 (3) , 672-682
Open AccessComparison of Socket Geometry, Socket Comfort, and Patient Experience between Manually- and Digitally-Designed Prosthetic Sockets for Lower-Limb Amputees: A Feasibility Study
Prosthetic socket manufacturing is experiencing a revolutionary shift towards using digital methods, such as 3D scanning and 3D printing. However, using digital methods requires the clinician to transfer their skills from making sockets by hand to making sockets with a computer. This shift in practice may change the socket geometry and fit; however, to what extent is unknown. Thus, the aim of this study was to explore the feasibility of analyzing geometric and clinical differences between digitally- and manually-designed sockets. Nine adult inpatients with below-knee amputation were recruited. Two sockets were 3D printed for each participant from 3D socket models that were developed from: (1) 3D scanning a manually-modified hand-casted positive mold of the residuum; and (2) a digitally-modified 3D scan of the residuum. Manual and digital procedures were compared for three measures: final socket geometry, the Socket Comfort Score, and a patient experience survey. Feasibility data were collected to measure protocol implementation fidelity to inform a future larger study. These data revealed that 89% of participants followed the intended protocol, no participants dropped out, and only one adverse event was report. As no significant geometric differences were found and participants experienced similar comfort scores between manually- and digitally-designed sockets, study feasibility was determined to be successful. Thus, a randomized control trial study will be conducted to draw statistically relevant conclusions from these outcome measures that may provide meaningful information for improving digital design procedures.
- 25 August 2023
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 48 (1) , 100-107
User perspectives of digital manufacturing for lower-limb prosthetic sockets
Background: There is growing interest to use digital technology (DT) for manufacturing lower-limb prosthetic sockets to improve efficiency and clinical outcomes. However, little is known about how lower-limb prosthesis users perceive DTs, such as 3D scanning and 3D printing. Objectives: This study aimed to provide an understanding of perceptions and experiences with DT for prosthetic socket manufacturing from the perspective of prosthesis users. Study design: A qualitative descriptive research study. Methods: Nine lower-limb prosthesis users (mean age 56; 5 female; 4 male) participated in one-on-one semistructured telephone interviews. Inductive thematic analysis was performed to identify a codebook and emerging themes from the interview transcripts. Results: Two major themes were identified: (1) expectations and prioritization of 3D printed socket usability and (2) facilitators and barriers to uptake of DT among patients. Conclusion: DT methods were found to be acceptable and feasible from a patient perspective, although technological advancements are still required, and real-time communication about the process may be vital for ensuring patient engagement. Consideration of these findings may improve patient satisfaction to emerging prosthesis treatment plans and ultimately support widespread adoption of DT as an additional tool for fabricating prosthetic sockets.
- 25 August 2023
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 48 (1) , 100-107
User perspectives of digital manufacturing for lower-limb prosthetic sockets
Background: There is growing interest to use digital technology (DT) for manufacturing lower-limb prosthetic sockets to improve efficiency and clinical outcomes. However, little is known about how lower-limb prosthesis users perceive DTs, such as 3D scanning and 3D printing. Objectives: This study aimed to provide an understanding of perceptions and experiences with DT for prosthetic socket manufacturing from the perspective of prosthesis users. Study design: A qualitative descriptive research study. Methods: Nine lower-limb prosthesis users (mean age 56; 5 female; 4 male) participated in one-on-one semistructured telephone interviews. Inductive thematic analysis was performed to identify a codebook and emerging themes from the interview transcripts. Results: Two major themes were identified: (1) expectations and prioritization of 3D printed socket usability and (2) facilitators and barriers to uptake of DT among patients. Conclusion: DT methods were found to be acceptable and feasible from a patient perspective, although technological advancements are still required, and real-time communication about the process may be vital for ensuring patient engagement. Consideration of these findings may improve patient satisfaction to emerging prosthesis treatment plans and ultimately support widespread adoption of DT as an additional tool for fabricating prosthetic sockets.
- 28 June 2023
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 47 (6) , 621-624
Business practices efficiency: Impact of integrating digital technology on clinical P&O practices
Additive manufacturing (AM) is on the path to transforming the approach to Prosthetics and Orthotics (P&O) manufacturing. Although digitalization of limbs and other body parts is not new to the field, it has not been widely accepted by the industry for various reasons. However, the reliability and precision that AM can attain, and the availability of various materials is improving rapidly. This professional opinion article discusses the ways that AM has changed P&O services, with a specific focus on prosthetic socket manufacturing. Digitalizing P&O services will eventually change the business model used in clinics, which is further explored here.
- 28 June 2023
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 47 (6) , 621-624
Business practices efficiency: Impact of integrating digital technology on clinical P&O practices
Additive manufacturing (AM) is on the path to transforming the approach to Prosthetics and Orthotics (P&O) manufacturing. Although digitalization of limbs and other body parts is not new to the field, it has not been widely accepted by the industry for various reasons. However, the reliability and precision that AM can attain, and the availability of various materials is improving rapidly. This professional opinion article discusses the ways that AM has changed P&O services, with a specific focus on prosthetic socket manufacturing. Digitalizing P&O services will eventually change the business model used in clinics, which is further explored here.