MPMark Podesta

Mark Podesta

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mark Podesta has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The effect of different image reconstruction techniques on pre-clinical quantitative imaging and dual-energy CT

    by Ana Vaniqui, Lotte E J R Schyns, Isabel P Almeida, Brent van der Heyden, Mark Podesta, Frank Verhaegen

    To analyse the effect of different image reconstruction techniques on image quality and dual energy CT (DECT) imaging metrics. A software platform for pre-clinical cone beam CT X-ray image reconstruction was built using the open-source reconstruction toolkit. Pre-processed projections were reconstructed with filtered back-projection and iterative algorithms, namely Feldkamp, Davis, and Kress (FDK), Iterative FDK, simultaneous algebraic reconstruction technique (SART), simultaneous iterative reconstruction technique and conjugate gradient. Imaging metrics were quantitatively assessed, using a quality assurance phantom, and DECT analysis was performed to determine the influence of each reconstruction technique on the relative electron density (ρe) and effective atomic number (Zeff) values. Iterative reconstruction had favourable results for the DECT analysis: a significantly smaller spread for each material in the ρe-Zeff space and lower Zeff and ρe residuals (on average 24 and 25% lower, respectively). In terms of image quality assurance, the techniques FDK, Iterative FDK and SART provided acceptable results. The three reconstruction methods showed similar geometric accuracy, uniformity and CT number results. The technique SART had a contrast-to-noise ratio up to 76% higher for solid water and twice as high for Teflon, but resolution was up to 28% lower when compared to the other two techniques. Advanced image reconstruction can be beneficial, but the benefit is small, and calculation times may be unacceptable with current technology. The use of targeted and downscaled reconstruction grids, larger, yet practicable, pixel sizes and GPU are recommended. An iterative CBCT reconstruction platform was build using RTK.


  • Automatic multiatlas based organ at risk segmentation in mice

    by Brent van der Heyden, Mark Podesta, Daniëlle Bp Eekers, Ana Vaniqui, Isabel P Almeida, Lotte Ejr Schyns, Stefan J van Hoof, Frank Verhaegen

    Objective: During the treatment planning of a preclinical small animal irradiation, which has time limitations for reasons of animal wellbeing and workflow efficiency, the time consuming organ at risk (OAR) delineation is performed manually. This work aimed to develop, demonstrate, and quantitatively evaluate an automated contouring method for six OARs in a preclinical irritation treatment workflow. Methods: Microcone beam CT images of nine healthy mice were contoured with an in-house developed multiatlas-based image segmentation (MABIS) algorithm for six OARs: kidneys, eyes, heart, and brain. The automatic contouring was compared with the manual delineation using three quantitative metrics: the Dice Similarity Coefficient (DSC), 95th percentile Hausdorff Distance, and the centre of mass displacement. Results: A good agreement between manual and automatic contouring was found for OARS with sharp organ boundaries. For the brain and the heart, the median DSC was larger than 0.94, the median 95th Hausdorff Distance smaller than 0.44 mm, and the median centre of mass displacement smaller than 0.20 mm. Lower DSC values were obtained for the other OARs, but the median DSC was still larger than 0.74 for the left eye, 0.69 for the right eye, 0.89 for the left kidney and 0.80 for the right kidney. Conclusion: The MABIS algorithm was able to delineate six OARs with a relatively high accuracy. Segmenting OARS with sharp organ boundaries performed better than low contrast OARs. Advances in knowledge: A MABIS algorithm is developed, evaluated, and demonstrated in a preclinical small animal irradiation research workflow.