Weiwei Ren
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Weiwei Ren has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Li-Ping Sun
Department of Medical Ultrasound, Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai, China
5 shared publications - Qiao Wang
Department of Medical Ultrasound, Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai, China
5 shared publications - Dandan Shan
Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, School of Medicine, Tongji University, China
4 shared publications - Le-Hang Guo
Department of Medical Ultrasound, Shanghai Tenth People's Hospital, Shanghai, China
4 shared publications - Hui-Xiong Xu
Department of Ultrasound, Institute of Ultrasound in Medicine and Engineering, Zhongshan Hospital, Fudan University, Shanghai, China
3 shared publications - Chuan Qin
Department of Medical Ultrasound, Jinshan Hospital of Fudan University, China
2 shared publications
Latest Publications
- Open Access
- 17 March 2026
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 112 (6) , 12636-12648
The value of ultrasound in the diagnosis and prediction of the severity of abdominal adhesions
Objective: The aim of this study was to construct a preoperative ultrasound prediction model, and compare its diagnostic performance with the existing sliding sign to predict the severity of abdominal adhesions in order to reduce the occurrence of intraoperative complications and shorten the duration of surgery. Methods: Between June 2020 and June 2022, 100 patients with a history of abdominal surgery were included in this retrospective study. All participants underwent ultrasound examination of five sites on the anterior abdominal wall before surgery. Eighteen sites were excluded because of surgical stomas, etc. Finally, 482 sites were examined by ultrasound, of which 138 (28.6%) were severe adhesions. Based on the intraoperative findings, the patients were divided into two groups: patients with severe adhesions and patients with non-severe adhesions. Finally, the data of 482 abdominal sites examined were randomly divided into a training cohort (70%) and a validation cohort (30%). The least absolute shrinkage and selection operator (LASSO) regression and multivariate binary logistic regression were used to determine the independent influencing factors, thereby constructing a clinical ultrasound prediction model for severe abdominal adhesions. The sensitivity, specificity, positive and negative predictive value (PPV and NPV) and accuracy of the model were calculated. Prediction models were established, and the area under the receiver operating curve (AUC) between models and compared with sliding sign (MA) using the DeLong test to determine the optimal model. At the same time, intraclass correlation coefficient (ICC) was used to evaluate the inter-observer agreement. Results: The LASSO regression showed that wall syndrome, traction sign, deformation of abdominal organs, two-layer peritoneal bright lines, sliding sign (head–foot direction mobility), and examination site were associated with severe adhesions. Multivariate analysis showed that traction sign, two-layer peritoneal bright lines, head–foot direction mobility and examination site (all P < 0.05) were the independent predictors of severe abdominal adhesion. Based on these predictors, the improved prediction model (referred as MB) was established. It showed that the diagnostic performance of MB was better than MA [AUC MB = 0.943 (95% CI: 0.920–0.967) vs AUC MA = 0.827 (95% CI: 0.920–0.967), P < 0.001] in the training cohort. The results were validated [AUC MB = 0.873 (95% CI: 0.818–0.928) vs AUC MA = 0.803 (95% CI: 0.755–0.851), P = 0.005] in the validation cohort. In the training cohort, the MB improved the specificity (22.5%), PPV (22.6%) and the accuracy (13.6%). In the validation cohort, the MB improved the specificity (19.2%), PPV (10.8%) and the accuracy (6.9%). At the same time, the ICC showed that the ultrasonic parameters had high consistency. Conclusions: In the presence of complex adhesions in the abdominal cavity, the new diagnostic model (MB) significantly improved the diagnostic performance compared with the conventional model (MA). The MB improved the AUC, specificity, PPV, and accuracy. Therefore, this model has the potential to reduce severe intraoperative complications.
- 17 March 2026
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 112 (6) , 12636-12648
Open AccessThe value of ultrasound in the diagnosis and prediction of the severity of abdominal adhesions
Objective: The aim of this study was to construct a preoperative ultrasound prediction model, and compare its diagnostic performance with the existing sliding sign to predict the severity of abdominal adhesions in order to reduce the occurrence of intraoperative complications and shorten the duration of surgery. Methods: Between June 2020 and June 2022, 100 patients with a history of abdominal surgery were included in this retrospective study. All participants underwent ultrasound examination of five sites on the anterior abdominal wall before surgery. Eighteen sites were excluded because of surgical stomas, etc. Finally, 482 sites were examined by ultrasound, of which 138 (28.6%) were severe adhesions. Based on the intraoperative findings, the patients were divided into two groups: patients with severe adhesions and patients with non-severe adhesions. Finally, the data of 482 abdominal sites examined were randomly divided into a training cohort (70%) and a validation cohort (30%). The least absolute shrinkage and selection operator (LASSO) regression and multivariate binary logistic regression were used to determine the independent influencing factors, thereby constructing a clinical ultrasound prediction model for severe abdominal adhesions. The sensitivity, specificity, positive and negative predictive value (PPV and NPV) and accuracy of the model were calculated. Prediction models were established, and the area under the receiver operating curve (AUC) between models and compared with sliding sign (MA) using the DeLong test to determine the optimal model. At the same time, intraclass correlation coefficient (ICC) was used to evaluate the inter-observer agreement. Results: The LASSO regression showed that wall syndrome, traction sign, deformation of abdominal organs, two-layer peritoneal bright lines, sliding sign (head–foot direction mobility), and examination site were associated with severe adhesions. Multivariate analysis showed that traction sign, two-layer peritoneal bright lines, head–foot direction mobility and examination site (all P < 0.05) were the independent predictors of severe abdominal adhesion. Based on these predictors, the improved prediction model (referred as MB) was established. It showed that the diagnostic performance of MB was better than MA [AUC MB = 0.943 (95% CI: 0.920–0.967) vs AUC MA = 0.827 (95% CI: 0.920–0.967), P < 0.001] in the training cohort. The results were validated [AUC MB = 0.873 (95% CI: 0.818–0.928) vs AUC MA = 0.803 (95% CI: 0.755–0.851), P = 0.005] in the validation cohort. In the training cohort, the MB improved the specificity (22.5%), PPV (22.6%) and the accuracy (13.6%). In the validation cohort, the MB improved the specificity (19.2%), PPV (10.8%) and the accuracy (6.9%). At the same time, the ICC showed that the ultrasonic parameters had high consistency. Conclusions: In the presence of complex adhesions in the abdominal cavity, the new diagnostic model (MB) significantly improved the diagnostic performance compared with the conventional model (MA). The MB improved the AUC, specificity, PPV, and accuracy. Therefore, this model has the potential to reduce severe intraoperative complications.
- Open Access
- 5 January 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (1) , 170
Utility of High-Frequency Ultrasound in Preoperative Evaluation of the Thickness of Cutaneous Melanoma
Introduction: The Breslow thickness of cutaneous melanoma (CM) is related to the surgical approach and is usually measured using a preoperative biopsy. However, tumor thickness is often underestimated by partial biopsies. Objectives: To identify whether high-frequency ultrasound (HFUS) can improve the accuracy of preoperative detection of Breslow thickness. Methods: Partial biopsies and HFUS measurements of Breslow thickness were analyzed in 17 patients with CM. Postoperative histopathologic examination is considered the gold standard. In different thicknesses, HFUS and partial biopsy were compared with postoperative pathology and their effects on tumor T staging and surgical margins. Results: The mean (±SD) Breslow thicknesses measured using HFUS, partial biopsy, and postoperative histopathology were 3.5 ± 2.2 mm, 1.8 ± 1.1 mm, and 3.2 ± 2.1 mm, respectively. The correlation coefficients were 0.76 (partial biopsy and postoperative histopathology) and 0.96 (HFUS and postoperative histopathology), respectively (all p < 0.01). Partial biopsy underestimated the Breslow thickness, and with a gradual increase in CM thickness, the underestimation became increasingly obvious. Partial biopsy led to an underestimation of T staging of the tumor in 8 (8/17 [47.1%]) patients, 4 (4/8 [50.0%]) of whom may have had insufficient surgical peripheral margins. Conversely, HFUS exhibited a significant downward trend of underestimation (0/17 [0%], p = 0.003). However, only 2 (2/17 [11.8%]) patients had slight overestimation for T staging (p = 0.485), and none of the overestimations changed the surgical margins. Conclusions: HFUS can provide an accurate preoperative assessment of Breslow thickness, and correlates better with postoperative histopathology.
- 5 January 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (1) , 170
Open AccessUtility of High-Frequency Ultrasound in Preoperative Evaluation of the Thickness of Cutaneous Melanoma
Introduction: The Breslow thickness of cutaneous melanoma (CM) is related to the surgical approach and is usually measured using a preoperative biopsy. However, tumor thickness is often underestimated by partial biopsies. Objectives: To identify whether high-frequency ultrasound (HFUS) can improve the accuracy of preoperative detection of Breslow thickness. Methods: Partial biopsies and HFUS measurements of Breslow thickness were analyzed in 17 patients with CM. Postoperative histopathologic examination is considered the gold standard. In different thicknesses, HFUS and partial biopsy were compared with postoperative pathology and their effects on tumor T staging and surgical margins. Results: The mean (±SD) Breslow thicknesses measured using HFUS, partial biopsy, and postoperative histopathology were 3.5 ± 2.2 mm, 1.8 ± 1.1 mm, and 3.2 ± 2.1 mm, respectively. The correlation coefficients were 0.76 (partial biopsy and postoperative histopathology) and 0.96 (HFUS and postoperative histopathology), respectively (all p < 0.01). Partial biopsy underestimated the Breslow thickness, and with a gradual increase in CM thickness, the underestimation became increasingly obvious. Partial biopsy led to an underestimation of T staging of the tumor in 8 (8/17 [47.1%]) patients, 4 (4/8 [50.0%]) of whom may have had insufficient surgical peripheral margins. Conversely, HFUS exhibited a significant downward trend of underestimation (0/17 [0%], p = 0.003). However, only 2 (2/17 [11.8%]) patients had slight overestimation for T staging (p = 0.485), and none of the overestimations changed the surgical margins. Conclusions: HFUS can provide an accurate preoperative assessment of Breslow thickness, and correlates better with postoperative histopathology.
- Open Access
- 25 June 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (13) , 1605
The Diagnostic Value of High-Frequency Ultrasound in Unclarified Lesions at the End of Extremities
Objectives: Unlike other body parts, unclarified lesions at the end of extremities have unique challenges due to their small size and interference. Traditional imaging methods struggle with low resolution. HFUS enhances resolution, offering a potential diagnostic value. Methods: From January 2019 to October 2023, the clinical and HFUS data of patients with unclarified lesions at the end of extremities were retrospectively analyzed. Independently, the diagnosis was made using two diagnostic modes (Mode A: only clinical information; Mode B: clinical and HFUS information). The diagnostic performance of the two modes was evaluated across different classification methods. Results: For all lesions, the correct rate of Mode B was higher than that of Mode A (52.8% vs. 18.4%, p < 0.001), and the indeterminate rate decreased by 43.0%. For benign lesions (51.0% vs. 18.2%), subungual lesions (40.8% vs. 21.1%), non-subungual lesions (55.6% vs. 17.8%), and common cases (60.9% vs. 20.3%), the diagnostic correct rate of Mode B was also higher than that of Mode A (all p < 0.05). However, there was no significant difference in rare lesions (9.8% vs. 4.9%) and malignant lesions (62.9% vs. 19.4%) between the two modes (both p > 0.05). Moreover, the indeterminate rate for all categories of lesions significantly diminished. Otherwise, Mode B demonstrated strong performance for malignant lesions (85.7% vs. 42.9%, p < 0.001). Conclusions: Adding HFUS can significantly improve the accuracy of diagnosing unclarified lesions at the end of extremities and reduce uncertainty, especially for benign and common lesions. HFUS has also demonstrated better performance in screening for malignant lesions.
- 25 June 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (13) , 1605
Open AccessThe Diagnostic Value of High-Frequency Ultrasound in Unclarified Lesions at the End of Extremities
Objectives: Unlike other body parts, unclarified lesions at the end of extremities have unique challenges due to their small size and interference. Traditional imaging methods struggle with low resolution. HFUS enhances resolution, offering a potential diagnostic value. Methods: From January 2019 to October 2023, the clinical and HFUS data of patients with unclarified lesions at the end of extremities were retrospectively analyzed. Independently, the diagnosis was made using two diagnostic modes (Mode A: only clinical information; Mode B: clinical and HFUS information). The diagnostic performance of the two modes was evaluated across different classification methods. Results: For all lesions, the correct rate of Mode B was higher than that of Mode A (52.8% vs. 18.4%, p < 0.001), and the indeterminate rate decreased by 43.0%. For benign lesions (51.0% vs. 18.2%), subungual lesions (40.8% vs. 21.1%), non-subungual lesions (55.6% vs. 17.8%), and common cases (60.9% vs. 20.3%), the diagnostic correct rate of Mode B was also higher than that of Mode A (all p < 0.05). However, there was no significant difference in rare lesions (9.8% vs. 4.9%) and malignant lesions (62.9% vs. 19.4%) between the two modes (both p > 0.05). Moreover, the indeterminate rate for all categories of lesions significantly diminished. Otherwise, Mode B demonstrated strong performance for malignant lesions (85.7% vs. 42.9%, p < 0.001). Conclusions: Adding HFUS can significantly improve the accuracy of diagnosing unclarified lesions at the end of extremities and reduce uncertainty, especially for benign and common lesions. HFUS has also demonstrated better performance in screening for malignant lesions.
- Open Access
- 1 July 2024
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 43 (4) , 238-249
Role of high-frequency ultrasound in differentiating benign and malignant skin lesions: potential and limitations
Purpose: This study examined the diagnostic value of high-frequency ultrasound (HFUS) features in differentiating between benign and malignant skin lesions.Methods: A total of 1,392 patients with 1,422 skin lesions who underwent HFUS examinations were included in an initial dataset (cohort 1) to identify features indicative of malignancy. Qualitative clinical and HFUS characteristics were recorded for all lesions. To determine which HFUS and clinical features were suggestive of malignancy, univariable and multivariable logistic regression analyses were employed. The diagnostic performance of HFUS features combined with clinical information was evaluated. This assessment was validated using internal data (cohort 2) and multicenter external data (cohort 3).Results: Features significantly associated with malignancy included age above 60 years; lesion location in the head, face, and neck or genital regions; changes in macroscopic appearance; crawling or irregular growth pattern; convex or irregular base; punctate hyperechogenicity; blood flow signals; and feeding arteries. The area under the receiver operating characteristic curve, sensitivity, and specificity of HFUS features combined with clinical information were 0.946, 92.5%, and 86.9% in cohort 1; 0.870, 93.1%, and 80.8% in cohort 2 (610 lesions); and 0.864, 86.2%, and 86.6% in cohort 3 (170 lesions), respectively. However, HFUS is not suitable for evaluating lesions less than 0.1 mm in thickness or lesions exhibiting surface hyperkeratosis.Conclusion: In a clinical setting, the integration of HFUS with clinical information exhibited good diagnostic performance in differentiating malignant and benign skin lesions. However, its utility was limited in evaluating extremely thin lesions and those exhibiting hyperkeratosis.
- 1 July 2024
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 43 (4) , 238-249
Open AccessRole of high-frequency ultrasound in differentiating benign and malignant skin lesions: potential and limitations
Purpose: This study examined the diagnostic value of high-frequency ultrasound (HFUS) features in differentiating between benign and malignant skin lesions.Methods: A total of 1,392 patients with 1,422 skin lesions who underwent HFUS examinations were included in an initial dataset (cohort 1) to identify features indicative of malignancy. Qualitative clinical and HFUS characteristics were recorded for all lesions. To determine which HFUS and clinical features were suggestive of malignancy, univariable and multivariable logistic regression analyses were employed. The diagnostic performance of HFUS features combined with clinical information was evaluated. This assessment was validated using internal data (cohort 2) and multicenter external data (cohort 3).Results: Features significantly associated with malignancy included age above 60 years; lesion location in the head, face, and neck or genital regions; changes in macroscopic appearance; crawling or irregular growth pattern; convex or irregular base; punctate hyperechogenicity; blood flow signals; and feeding arteries. The area under the receiver operating characteristic curve, sensitivity, and specificity of HFUS features combined with clinical information were 0.946, 92.5%, and 86.9% in cohort 1; 0.870, 93.1%, and 80.8% in cohort 2 (610 lesions); and 0.864, 86.2%, and 86.6% in cohort 3 (170 lesions), respectively. However, HFUS is not suitable for evaluating lesions less than 0.1 mm in thickness or lesions exhibiting surface hyperkeratosis.Conclusion: In a clinical setting, the integration of HFUS with clinical information exhibited good diagnostic performance in differentiating malignant and benign skin lesions. However, its utility was limited in evaluating extremely thin lesions and those exhibiting hyperkeratosis.
- Open Access
- 25 October 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (21) , 3305
High-Frequency Ultrasound Imaging to Distinguish High-Risk and Low-Risk Dermatofibromas
Background: Dermatofibroma has various pathological classifications, some of which pose a risk of recurrence and metastasis. Distinguishing these high-risk dermatofibromas based on appearance alone can be challenging. Therefore, high-frequency ultrasound may provide additional internal information on these lesions, helping to identify high-risk and low-risk dermatofibroma early. Methods: In this retrospective study, 50 lesions were analyzed to explore the correlation between clinical and high-frequency ultrasound features and dermatofibroma risk level. Based on their pathological features, the lesions were divided into high-risk (n = 17) and low-risk (n = 33) groups. Subsequently, an identification model based on significant high-frequency ultrasound features was developed. Results: Significant differences were observed in the thickness, shape, internal echogenicity, stratum basal, and Doppler vascular patterns between the high-risk and low-risk groups. The median lesion thickness for the high-risk dermatofibroma group was 4.1 mm (IQR: 3.2–6.1 mm), while it was 3.1 mm (IQR: 1.3–4.2 mm) for the low-risk dermatofibroma group. In the high-risk dermatofibroma group, irregular morphology was predominant (70.6%, 12/17), the most common being dermis-to-subcutaneous soft tissue penetration (64.7%, 11/17), and heterogenous internal echogenicity was observed in the majority of cases (76.5%, 13/17). On the other hand, regular morphology was more prevalent in the low-risk dermatofibroma group (78.8%, 26/33), primarily limited to the dermis layer (78.8%, 26/33), with homogeneous internal echogenicity also being prevalent in the majority of cases (81.8%, 27/33). Regarding the Doppler vascularity pattern, 69.7% (23/33) of low-risk dermatofibromas had no blood flow, while 64.7% (11/17) of high-risk dermatofibromas had blood flow. Conclusion: High-frequency ultrasound is crucial in distinguishing high-risk and low-risk dermatofibromas, making it invaluable for clinical management.
- 25 October 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (21) , 3305
Open AccessHigh-Frequency Ultrasound Imaging to Distinguish High-Risk and Low-Risk Dermatofibromas
Background: Dermatofibroma has various pathological classifications, some of which pose a risk of recurrence and metastasis. Distinguishing these high-risk dermatofibromas based on appearance alone can be challenging. Therefore, high-frequency ultrasound may provide additional internal information on these lesions, helping to identify high-risk and low-risk dermatofibroma early. Methods: In this retrospective study, 50 lesions were analyzed to explore the correlation between clinical and high-frequency ultrasound features and dermatofibroma risk level. Based on their pathological features, the lesions were divided into high-risk (n = 17) and low-risk (n = 33) groups. Subsequently, an identification model based on significant high-frequency ultrasound features was developed. Results: Significant differences were observed in the thickness, shape, internal echogenicity, stratum basal, and Doppler vascular patterns between the high-risk and low-risk groups. The median lesion thickness for the high-risk dermatofibroma group was 4.1 mm (IQR: 3.2–6.1 mm), while it was 3.1 mm (IQR: 1.3–4.2 mm) for the low-risk dermatofibroma group. In the high-risk dermatofibroma group, irregular morphology was predominant (70.6%, 12/17), the most common being dermis-to-subcutaneous soft tissue penetration (64.7%, 11/17), and heterogenous internal echogenicity was observed in the majority of cases (76.5%, 13/17). On the other hand, regular morphology was more prevalent in the low-risk dermatofibroma group (78.8%, 26/33), primarily limited to the dermis layer (78.8%, 26/33), with homogeneous internal echogenicity also being prevalent in the majority of cases (81.8%, 27/33). Regarding the Doppler vascularity pattern, 69.7% (23/33) of low-risk dermatofibromas had no blood flow, while 64.7% (11/17) of high-risk dermatofibromas had blood flow. Conclusion: High-frequency ultrasound is crucial in distinguishing high-risk and low-risk dermatofibromas, making it invaluable for clinical management.
- 28 February 2020
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 93 (1109) , 20190614
Correlation between ultrasound consolidated score and simple endoscopic score for determining the activity of Crohn’s disease
Objectives: The aim of this study was to develop an ultrasound consolidated score (UCS) in determining the activity of Crohn’s disease (CD) and evaluate it with reference to simple endoscopic score (SES). Methods: From June 2014 to June 2017, 66 patients with CD were retrospectively enrolled in this study. Each patient underwent endoscopy and transabdominal ultrasound (US) examination. The morphological symmetry, echogenicity of bowel wall, bowel wall layer structure, echogenicity of peri-bowel fat, bowel wall thickness (BWT), and Limberg type on power Doppler US were assessed with transabdominal US, and an UCS scoring system was developed based on these characteristics. Endoscopic results were used as the reference standard and SES was calculated to determine the CD activity. Receiver operating characteristic curve analysis was performed to assess the diagnostic performance for determining CD activity and the correlation between UCS and SES was assessed using Spearman correlation analysis. Results: 330 intestinal segments in 66 patients were included. The UCS of the segments in the remission phase ranged from 3.0 to 9.0 (mean, 3.6 ± 0.9) whereas in the active phase from 3.0 to 20.0 (mean, 10.6 ± 4.0) (p < 0.001). The cut-off value of UCS was 6. The associated area under ROC curve, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 0.980, 88.3%, 95.5%, 93.8%, 91.3%, and 92.3%, respectively. The correlation coefficient between UCS and SES was 0.90, which was higher than the correlation coefficient of 0.83 between BWT and SES. Conclusions: The newly developed UCS with transabdominal US has a good performance and potentially provides an effective alternative for evaluating the activity of CD. Advances in knowledge: UCS is an effective method to evaluate the activity of CD because it provides comprehensive information of the disease. Therefore, it could be employed as an alternative for diagnosis of CD.
- 28 February 2020
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 93 (1109) , 20190614
Correlation between ultrasound consolidated score and simple endoscopic score for determining the activity of Crohn’s disease
Objectives: The aim of this study was to develop an ultrasound consolidated score (UCS) in determining the activity of Crohn’s disease (CD) and evaluate it with reference to simple endoscopic score (SES). Methods: From June 2014 to June 2017, 66 patients with CD were retrospectively enrolled in this study. Each patient underwent endoscopy and transabdominal ultrasound (US) examination. The morphological symmetry, echogenicity of bowel wall, bowel wall layer structure, echogenicity of peri-bowel fat, bowel wall thickness (BWT), and Limberg type on power Doppler US were assessed with transabdominal US, and an UCS scoring system was developed based on these characteristics. Endoscopic results were used as the reference standard and SES was calculated to determine the CD activity. Receiver operating characteristic curve analysis was performed to assess the diagnostic performance for determining CD activity and the correlation between UCS and SES was assessed using Spearman correlation analysis. Results: 330 intestinal segments in 66 patients were included. The UCS of the segments in the remission phase ranged from 3.0 to 9.0 (mean, 3.6 ± 0.9) whereas in the active phase from 3.0 to 20.0 (mean, 10.6 ± 4.0) (p < 0.001). The cut-off value of UCS was 6. The associated area under ROC curve, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 0.980, 88.3%, 95.5%, 93.8%, 91.3%, and 92.3%, respectively. The correlation coefficient between UCS and SES was 0.90, which was higher than the correlation coefficient of 0.83 between BWT and SES. Conclusions: The newly developed UCS with transabdominal US has a good performance and potentially provides an effective alternative for evaluating the activity of CD. Advances in knowledge: UCS is an effective method to evaluate the activity of CD because it provides comprehensive information of the disease. Therefore, it could be employed as an alternative for diagnosis of CD.