Jie Pan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jie Pan has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Tian Li
School of Civil Engineering, Chongqing University, Chongqing, China
3 shared publications Qingshan Yang
2 shared publications- Sorin Tibuleac
ADVA Optical Networking, Norcross, GA 30092, USA
2 shared publications - Stephen E. Ralph
School of ECE, Georgia Institute of Technology, 30318, Atlanta GA, USA
2 shared publications Andrew Stark
Georgia Institute of Technology, United States
1 shared publication- Cheng Liu
College of Electrical and Information Engineering, Hunan University, Changsha, China
1 shared publication
Latest Publications
- 19 August 2025
- Published by Elsevier in Ocean Engineering
- Vol. 341
Numerical investigation of yaw-controlled wake effects on fatigue load distribution in downstream wind turbines
- 19 August 2025
- Published by Elsevier in Ocean Engineering
- Vol. 341
Numerical investigation of yaw-controlled wake effects on fatigue load distribution in downstream wind turbines
- 15 August 2025
- Published by Elsevier in Renewable Energy
- Vol. 256
Real-time cooperative yaw control with informer-based wind predicting for wind power generation enhancement
- 15 August 2025
- Published by Elsevier in Renewable Energy
- Vol. 256
Real-time cooperative yaw control with informer-based wind predicting for wind power generation enhancement
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
A calculation method of coupling relationship between multiple sections in chain power grid
Low frequency oscillation or poor dynamic stability tends to occur in long-chain interconnected power system. Factors on the source and grid side. The factors on the generator side and network side both have certain influence on the system dynamic stability, such as, generator control parameters, load characteristics, operation mode, subsystem internal structure and power flow, etc. In order to research the effect of transmission section location and power flow on system dynamic stability, in this paper, for the network made of several chain coupling structure sections, a calculation method was proposed about sensitivity and coupling degree of transmission sections, which contributes to analyze difference among influence of different sections on stability. At first, change law of system damping ratio and relative angles between the delivery end and the receiving end of interconnected system, was analyzed, based on relationship between interface power flow and relative power angle of units on both sides in chain grid. And then, the derivation was conducted, about relative sensitivity of system dynamic stability to interface power flow, following the exploration of coupling mechanism between sections power flow. Research shows that there are several factors associate with the section sensitivity, such as reactance, the angle difference and inertia time constants of sending-end units. Furthermore, the proposed method was applied in three-machine chain system model and Meng-xi chain network, and theoretical conclusion and simulation results verified the validity and feasibility of this method. When actual power grid running dynamic stably, calculation of the sensitivity and correlation of the cross section can provide a reliable basis, for the coordination control of power flow between several sections, as well as system damping improvement program.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
A calculation method of coupling relationship between multiple sections in chain power grid
Low frequency oscillation or poor dynamic stability tends to occur in long-chain interconnected power system. Factors on the source and grid side. The factors on the generator side and network side both have certain influence on the system dynamic stability, such as, generator control parameters, load characteristics, operation mode, subsystem internal structure and power flow, etc. In order to research the effect of transmission section location and power flow on system dynamic stability, in this paper, for the network made of several chain coupling structure sections, a calculation method was proposed about sensitivity and coupling degree of transmission sections, which contributes to analyze difference among influence of different sections on stability. At first, change law of system damping ratio and relative angles between the delivery end and the receiving end of interconnected system, was analyzed, based on relationship between interface power flow and relative power angle of units on both sides in chain grid. And then, the derivation was conducted, about relative sensitivity of system dynamic stability to interface power flow, following the exploration of coupling mechanism between sections power flow. Research shows that there are several factors associate with the section sensitivity, such as reactance, the angle difference and inertia time constants of sending-end units. Furthermore, the proposed method was applied in three-machine chain system model and Meng-xi chain network, and theoretical conclusion and simulation results verified the validity and feasibility of this method. When actual power grid running dynamic stably, calculation of the sensitivity and correlation of the cross section can provide a reliable basis, for the coordination control of power flow between several sections, as well as system damping improvement program.
- 1 January 2017
- Published by Optica Publishing Group
- Vol. 7, M2E.5
Real-Time Investigation and Prediction of Transmission Penalties for PDM-8QAM/16QAM Super-Channels in Flexible Grid DWDM Networks
Real-time transmission penalties of PDM-8QAM and PDM-16QAM super-channel system are investigated for various system configurations in a ROADM enabled flexible grid link. Gaussian noise model is verified in systems with both filtering and crosstalk penalties.
- 1 January 2017
- Published by Optica Publishing Group
- Vol. 7, M2E.5
Real-Time Investigation and Prediction of Transmission Penalties for PDM-8QAM/16QAM Super-Channels in Flexible Grid DWDM Networks
Real-time transmission penalties of PDM-8QAM and PDM-16QAM super-channel system are investigated for various system configurations in a ROADM enabled flexible grid link. Gaussian noise model is verified in systems with both filtering and crosstalk penalties.
- 1 January 2014
- Published by Optica Publishing Group
- p. Th1I.1
Gaussian Noise Model Aided In-band Crosstalk Analysis in ROADM-enabled DWDM Networks
We extend crosstalk weighting metric to the nonlinear region and combined with Gaussian noise model for system analysis and performance predictions. Nonlinear parametric interaction between crosstalk and signal is analyzed by simulation and experiment.
- 1 January 2014
- Published by Optica Publishing Group
- p. Th1I.1
Gaussian Noise Model Aided In-band Crosstalk Analysis in ROADM-enabled DWDM Networks
We extend crosstalk weighting metric to the nonlinear region and combined with Gaussian noise model for system analysis and performance predictions. Nonlinear parametric interaction between crosstalk and signal is analyzed by simulation and experiment.
- 1 January 2013
- Published by Optica Publishing Group
- p. OW4B.6
Fractionally-Spaced Frequency Domain Linear Crosstalk Cancellation with Spectral Alignment Techniques for Coherent Superchannel Optical Systems
A computationally efficient frequency domain implementation of a fractionally-spaced equalizer with inter-channel spectral alignment is proposed for inter-channel-crosstalk cancellation. The algorithm is an essential component of crosstalk cancellation and reduces the complexity without sacrificing performance.
- 1 January 2013
- Published by Optica Publishing Group
- p. OW4B.6
Fractionally-Spaced Frequency Domain Linear Crosstalk Cancellation with Spectral Alignment Techniques for Coherent Superchannel Optical Systems
A computationally efficient frequency domain implementation of a fractionally-spaced equalizer with inter-channel spectral alignment is proposed for inter-channel-crosstalk cancellation. The algorithm is an essential component of crosstalk cancellation and reduces the complexity without sacrificing performance.