SBSandika O. Baboolal

Sandika O. Baboolal

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sandika O. Baboolal has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Retinal nerve fibre layer thickness in Black South African children: A preliminary study

    by Nerissa Govender, Sandika O. Baboolal

    Background: Spectral domain optical coherence tomography (SD-OCT) provides age-adjusted retinal nerve fibre layer (RNFL) thickness measurements, essential for diagnosing glaucoma. However, normative databases in these devices apply to individuals older than 18 years. The absence of a normative database for individuals younger than 18 years makes diagnosing glaucoma in this age group challenging. Aim: To describe the average and quadrant RNFL thicknesses in children of Black ethnicity. Settings: McCord Provincial Eye Hospital, Durban, South Africa. Methods: A prospective, hospital-based study was conducted using a convenience sampling method. One clinically normal eye was selected from each child participant, aged 5–18 years. The RNFL thickness was measured using the iVue100™ SD-OCT device. Results: Seventy-three children were enrolled in this study. The mean RNFL thickness was 107.32 ± 8.1 µm. The mean thickness of the inferior, superior, nasal and temporal quadrants was 135.1 ± 13.65 µm, 135.6 ± 14.59 µm, 83.2 ± 10.86 µm and 75.4 ± 9.03 µm, respectively. No statistically significant association was observed between the average RNFL thickness and variables such as age (p = 0.438), sex (p = 0.106), spherical equivalent (p = 0.632) or axial length (p = 0.20). Conclusion: This study provides normative values for RNFL thickness in South African children of Black ethnicity and suggests potential ethnic variation. Further validation studies are required before these normative values can reliably be used in a clinical setting. Contribution: This study addressed a gap in research on normative values for RNFL thickness in an under-represented paediatric population.


  • Open Access

    Specialist training: workplace-based assessments impact on teaching, learning and feedback to support competency-based postgraduate programs

    by Sandika O. Baboolal, Veena S. Singaram

    Background: Workplace-based assessments (WBAs) are part of a competency-based curriculum where training progression is dependent on the achievement of defined competencies in a real-world clinical environment. There is a significant literature gap on the impact of WBAs implemented in resource constrained countries and their contextual challenges. This study aimed to examine the use, impact, and educational context of WBAs in South African medical specialist training programs drawing on perspectives from both trainees and trainers to identify educational challenges and propose effective solutions. Methods: A mixed methods national electronic survey was conducted with specialist medical trainees and supervising trainers from all eight specialist training institutions in South Africa involving 16 specialities. The survey responses were voluntary and anonymous. The survey was closed after seven months when data saturation was achieved. Descriptive statistical analysis was performed using SPSS Version 27 (SPSS Inc, 2012, Chicago, IL) for the quantitative analysis. The thematic coding framework for the qualitative analysis was facilitated by NVivo Version 12 software. Results: There were 108 ethnically diverse supervising trainers and 248 specialist trainees’ survey respondents. Across the 16 medical specialities, 45% of the respondents were using WBAs. Despite contextual resource and staff challenges, this study found that WBAs had a positive impact to Kirkpatrick level 2 in providing actionable feedback to improve competency. WBA users had a significantly higher rating for trainee supervision (p < 0.01), general quality of feedback on trainee competence (< 0.01) and the specialist training program (p = 0.03) compared to WBA non-users. They also had a higher rating for the assessment of the trainee as a professional (p < 0.01); scholar (p < 0.01); communicator (p < 0.01); collaborator (p = 0.001) and leader/manager (p < 0.001) based on the AfriMEDS competency framework. Racism, sexism and favouritism were challenges that negatively affected the training programs. Conclusion: Overall, this study reports that the use of WBAs had a substantially favourable impact on teaching, learning, feedback and supports a competency-based approach to specialist training programs. Addressing the contextual concerns that negatively impact training; training the trainees and trainers about their relationship, roles and responsibilities; and focusing on a trainee-centred, inclusive and empowering teaching approach will help further enhance its effectiveness.


  • South African Eye Study (SAES): ethnic differences in central corneal thickness and intraocular pressure

    by S O Baboolal, D P Smit

    Glaucoma is the leading cause of irreversible blindness worldwide. South Africa has a diverse population but there is a lack of published ethnic specific normative data. The purpose of the study is to determine the distribution of intraocular pressure (IOP) and central corneal thickness (CCT) values in a multi-ethnic South African population and to determine additional systemic and ocular factors that influence IOP and CCT. This cross-sectional study included a total of 402 participants with 706 eyes aged 18–94 years. Participants underwent a standardized interviewer-administered questionnaire for risk factor assessment followed by a full ophthalmic examination. The averages of six IOP readings were measured with an Icare PRO tonometer and CCT was measured with a Pentacam. The mean CCT readings in the African, Mixed ethnicity, and Caucasian participants were 514.77±31.86, 531.77±35.17, and 549.97±30.51 μm (PP=0.07). Africans had significantly higher IOP than Mixed ethnicity (P=0.034) and Caucasians (P=0.011). Hypertensives had a higher IOP (P=0.03). Age and pseudophakia were associated with a lower IOP (PPβ=0.021; P<0.001). In the South African Eye Study (SAES), Africans had the thinnest corneas and highest IOP followed by Mixed ethnicity and Caucasians. Including systemic and ocular factors that influence IOP specific to each population and ethnic group, will lead to a more accurate clinical risk stratification in glaucoma management.