MAMuhammad Azzumar

Muhammad Azzumar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Muhammad Azzumar has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • IoT-enabled remote calibration system for thermal imagers: Design, implementation, and metrological evaluation

    by Muhammad Azzumar, Iip Ahmad Rifai, Gigin Ginanjar, Yonan Prihhapso, Melati Azizka Fajria, Dwi Larassati, Arfan Sindhu Tistomo, Rizky Mulya Akbar, Ghufron Zaid, Aditya Achmadi

  • A novel risk assessment framework: integrating fuzzy failure mode and effect analysis with ISO 31000 and ISO 9001 standards

    by Meilinda Ayundyahrini, Tri Widianti, Himma Firdaus, Muhammad Azzumar, Adindra Vickar Ega, Tri Rakhmawati, Sih Damayanti, Sik Sumaedi, Anggini Dinaseviani, Nurfadlih Syahlani, et al.

    Purpose: This study proposes a novel risk assessment framework that integrates Failure Mode and Effects Analysis (FMEA), fuzzy logic, and the Analytic Hierarchy Process (AHP). To ensure standardized and comprehensive implementation, the framework is aligned with ISO 31000 and ISO 9001. As organizational processes become more complex, digitalizing risk assessment is increasingly important to ensure consistency, traceability, and effectiveness. Accordingly, this study also aims to develop software that implements the proposed framework. Design/methodology/approach: A web-based application was developed using CodeIgniter (CI), a lightweight and widely adopted PHP framework. The proposed framework was validated through three case studies: a fan testing simulation, an Organic Rankine Cycle design, and records from a government institution. Findings: An integrated Fuzzy–FMEA–AHP framework, aligned with ISO 31000 and ISO 9001, was successfully developed. The framework emphasizes standardized risk assessment processes, role-based authority, and structured documentation. Validation results show that both manual and automated calculations achieved high accuracy, with percentage errors below 3%. The framework effectively prioritizes risks while reducing assessor bias. Moreover, digital implementation improves operational efficiency, strengthens decision-making, and enables real-time, comprehensive documentation. Practical implications: This study contributes to the advancement of risk management practices by providing organizations with a standardized, objective, and digitally supported approach to risk assessment. Originality/value: Traditional FMEA is limited by expert subjectivity and equal weighting of risk factors. This study addresses these limitations by integrating Fuzzy–FMEA–AHP with ISO 31000 and ISO 9001 within a single operational framework. To the authors' knowledge, this is the first study to combine Fuzzy–FMEA–AHP with multiple-standard integration and implement it through a web-based system.

  • Open Access

    The Surface Plate Calibration Comparison Based on The Grid Method

    by Asep Hapiddin, Okasatria Novyanto, A. Praba Drijarkara, Muhammad Azzumar, Mohamad Syahadi, Miftahul Munir, Ninuk Ragil Prasasti, Nur Tjahyo Eka Darmayanti, Budhy Basuki, Hidayat Wiriadinata

  • Characterization of developed low thermal scanner for DC voltage measurement

    by Miftahul Munir, Muhammad Azzumar, Mohamad Syahadi

    A low thermal scanner has been completely developed for improving DC voltage calibration from semi-automatic to fully automatic measurement system. The application of the switching system inside the built-up scanner introduced offset voltage to the measurement due to thermal electromotive force (EMF). A differential measurement method was proposed to characterize the thermal EMF of the scanner, and this method has been compared to previous characterization using the direct measurement method. The results show that the differential measurement method could minimize the thermal EMF effect, and the thermal EMF had a negligible contribution to the measurement for uncertainty levels around 10 to 11 ppm. Therefore, the differential measurement method is recommended for DC voltage calibration with uncertainty levels below 10 ppm since the thermal EMF can significantly affect the measurement. Furthermore, the direct measurement method is suggested for DC voltage calibration with uncertainty levels above 11 ppm since it can speed up the measurement process.

  • Open Access

    Temperature control system for thermistor mount calibration

    by Nibras Fitrah Yayienda, Windi Kurnia Perangin-Angin, Hadi Sardjono, Lukluk Khairiyati, Muhammad Azzumar, Hayati Amalia

    A thermistor mount is a thermal radiofrequency (RF) power sensor that related to room temperature conditions. A precise measurement of the thermistor mount depends on the stability of ambient temperature. The unstable fluctuation of ambient temperature contributed to considerable measurement uncertainty of calibration factor (CF) of thermistor mount. A temperature control system is used to decrease the measurement uncertainty. The temperature control system consists of several devices, namely a heating block, a proportional integral derivative (PID) controller, Peltier elements, a temperature sensor, and a circulation of water. The design resulted in a stable temperature, and the fluctuation is kept stable around ± 0.1°C. Measurement repeatability of RF power of thermistor mount was much better by using the temperature control system. Measurement uncertainty of the CF was decreased from 0.045 to 0.020 in the range up to 18 GHz. The temperature control system has improved the measurement uncertainty of the CF of the thermistor mount.

  • Open Access

    INDUCTANCE VALIDATION OF LCR METER AFTER RECALIBRATION

    by Lukluk Khairiyati, Muhammad Azzumar, Miftahul Munir, Mohamad Syahadi

    Laboratory of National Measurement Standard for Electricity and Time (NMS ET Lab) has validated the measurement results pre and post the LCR meter recalibration process on inductance parameters. The validation process was carried out at nominal values of 100 μH, 1 mH, 10 mH, 100 mH and 1 H in accordance to the reference standards. The direct measurement method was used to measure the inductance parameter of LCR meter with standard inductor. Validation is carried out by comparing the measurement results pre and post the LCR meter recalibration process at SCL - Hong Kong. Based on the En number analysis, the values between -0.21 to 0.44 were obtained for 5 measurement points, therefore the calibration system and method used by NMS ET Lab are valid and have measurement results that are equivalent to other countries.

  • Open Access

    Uji Keseragaman dan Kestabilan Bak Air Sebagai Media Kalibrasi Termometer Telinga

    by Dwi Larassati, Rahman Sholeh, Iip Ahmad Rifai, Ghufron Zaid, Melati Azizka Fajria, Arfan Sindhu Tistomo, Suherlan Suherlan, Aditya Achmadi, Muhammad Azzumar