Muhammad Azzumar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Muhammad Azzumar has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Mohamad Syahadi
National Research and Innovation Agency (BRIN)
3 shared publications Dwi Larassati
2 shared publicationsMelati Azizka Fajria
2 shared publications- Miftahul Munir
Institut Ilmu Kesehatan Nahdlatul Ulama Tuban, Tuban, Indonesia, Indonesia
2 shared publications A. Praba Drijarkara
National Accreditation Body of Indonesia, KAN
1 shared publication- Adindra Vickar Ega
Universitas Indonesia
1 shared publication
Latest Publications
- 6 July 2026
- Published by Elsevier in Measurement
- Vol. 287
IoT-enabled remote calibration system for thermal imagers: Design, implementation, and metrological evaluation
- 6 July 2026
- Published by Elsevier in Measurement
- Vol. 287
IoT-enabled remote calibration system for thermal imagers: Design, implementation, and metrological evaluation
- 6 March 2026
- Published by Emerald Publishing in International Journal of Quality & Reliability Management
- Vol. 43 (4) , 1217-1247
A novel risk assessment framework: integrating fuzzy failure mode and effect analysis with ISO 31000 and ISO 9001 standards
Purpose: This study proposes a novel risk assessment framework that integrates Failure Mode and Effects Analysis (FMEA), fuzzy logic, and the Analytic Hierarchy Process (AHP). To ensure standardized and comprehensive implementation, the framework is aligned with ISO 31000 and ISO 9001. As organizational processes become more complex, digitalizing risk assessment is increasingly important to ensure consistency, traceability, and effectiveness. Accordingly, this study also aims to develop software that implements the proposed framework. Design/methodology/approach: A web-based application was developed using CodeIgniter (CI), a lightweight and widely adopted PHP framework. The proposed framework was validated through three case studies: a fan testing simulation, an Organic Rankine Cycle design, and records from a government institution. Findings: An integrated Fuzzy–FMEA–AHP framework, aligned with ISO 31000 and ISO 9001, was successfully developed. The framework emphasizes standardized risk assessment processes, role-based authority, and structured documentation. Validation results show that both manual and automated calculations achieved high accuracy, with percentage errors below 3%. The framework effectively prioritizes risks while reducing assessor bias. Moreover, digital implementation improves operational efficiency, strengthens decision-making, and enables real-time, comprehensive documentation. Practical implications: This study contributes to the advancement of risk management practices by providing organizations with a standardized, objective, and digitally supported approach to risk assessment. Originality/value: Traditional FMEA is limited by expert subjectivity and equal weighting of risk factors. This study addresses these limitations by integrating Fuzzy–FMEA–AHP with ISO 31000 and ISO 9001 within a single operational framework. To the authors' knowledge, this is the first study to combine Fuzzy–FMEA–AHP with multiple-standard integration and implement it through a web-based system.
- 6 March 2026
- Published by Emerald Publishing in International Journal of Quality & Reliability Management
- Vol. 43 (4) , 1217-1247
A novel risk assessment framework: integrating fuzzy failure mode and effect analysis with ISO 31000 and ISO 9001 standards
Purpose: This study proposes a novel risk assessment framework that integrates Failure Mode and Effects Analysis (FMEA), fuzzy logic, and the Analytic Hierarchy Process (AHP). To ensure standardized and comprehensive implementation, the framework is aligned with ISO 31000 and ISO 9001. As organizational processes become more complex, digitalizing risk assessment is increasingly important to ensure consistency, traceability, and effectiveness. Accordingly, this study also aims to develop software that implements the proposed framework. Design/methodology/approach: A web-based application was developed using CodeIgniter (CI), a lightweight and widely adopted PHP framework. The proposed framework was validated through three case studies: a fan testing simulation, an Organic Rankine Cycle design, and records from a government institution. Findings: An integrated Fuzzy–FMEA–AHP framework, aligned with ISO 31000 and ISO 9001, was successfully developed. The framework emphasizes standardized risk assessment processes, role-based authority, and structured documentation. Validation results show that both manual and automated calculations achieved high accuracy, with percentage errors below 3%. The framework effectively prioritizes risks while reducing assessor bias. Moreover, digital implementation improves operational efficiency, strengthens decision-making, and enables real-time, comprehensive documentation. Practical implications: This study contributes to the advancement of risk management practices by providing organizations with a standardized, objective, and digitally supported approach to risk assessment. Originality/value: Traditional FMEA is limited by expert subjectivity and equal weighting of risk factors. This study addresses these limitations by integrating Fuzzy–FMEA–AHP with ISO 31000 and ISO 9001 within a single operational framework. To the authors' knowledge, this is the first study to combine Fuzzy–FMEA–AHP with multiple-standard integration and implement it through a web-based system.
- Open Access
- 1 September 2023
- Published by Kyushu University in Evergreen
- Vol. 10 (3) , 1819-1825
The Surface Plate Calibration Comparison Based on The Grid Method
- 1 September 2023
- Published by Kyushu University in Evergreen
- Vol. 10 (3) , 1819-1825
Open AccessThe Surface Plate Calibration Comparison Based on The Grid Method
- 4 July 2023
- Published by IOP Publishing in Engineering Research Express
- Vol. 5 (3) , 035003
Characterization of developed low thermal scanner for DC voltage measurement
A low thermal scanner has been completely developed for improving DC voltage calibration from semi-automatic to fully automatic measurement system. The application of the switching system inside the built-up scanner introduced offset voltage to the measurement due to thermal electromotive force (EMF). A differential measurement method was proposed to characterize the thermal EMF of the scanner, and this method has been compared to previous characterization using the direct measurement method. The results show that the differential measurement method could minimize the thermal EMF effect, and the thermal EMF had a negligible contribution to the measurement for uncertainty levels around 10 to 11 ppm. Therefore, the differential measurement method is recommended for DC voltage calibration with uncertainty levels below 10 ppm since the thermal EMF can significantly affect the measurement. Furthermore, the direct measurement method is suggested for DC voltage calibration with uncertainty levels above 11 ppm since it can speed up the measurement process.
- 4 July 2023
- Published by IOP Publishing in Engineering Research Express
- Vol. 5 (3) , 035003
Characterization of developed low thermal scanner for DC voltage measurement
A low thermal scanner has been completely developed for improving DC voltage calibration from semi-automatic to fully automatic measurement system. The application of the switching system inside the built-up scanner introduced offset voltage to the measurement due to thermal electromotive force (EMF). A differential measurement method was proposed to characterize the thermal EMF of the scanner, and this method has been compared to previous characterization using the direct measurement method. The results show that the differential measurement method could minimize the thermal EMF effect, and the thermal EMF had a negligible contribution to the measurement for uncertainty levels around 10 to 11 ppm. Therefore, the differential measurement method is recommended for DC voltage calibration with uncertainty levels below 10 ppm since the thermal EMF can significantly affect the measurement. Furthermore, the direct measurement method is suggested for DC voltage calibration with uncertainty levels above 11 ppm since it can speed up the measurement process.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2580 (1)
Temperature control system for thermistor mount calibration
A thermistor mount is a thermal radiofrequency (RF) power sensor that related to room temperature conditions. A precise measurement of the thermistor mount depends on the stability of ambient temperature. The unstable fluctuation of ambient temperature contributed to considerable measurement uncertainty of calibration factor (CF) of thermistor mount. A temperature control system is used to decrease the measurement uncertainty. The temperature control system consists of several devices, namely a heating block, a proportional integral derivative (PID) controller, Peltier elements, a temperature sensor, and a circulation of water. The design resulted in a stable temperature, and the fluctuation is kept stable around ± 0.1°C. Measurement repeatability of RF power of thermistor mount was much better by using the temperature control system. Measurement uncertainty of the CF was decreased from 0.045 to 0.020 in the range up to 18 GHz. The temperature control system has improved the measurement uncertainty of the CF of the thermistor mount.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2580 (1)
Open AccessTemperature control system for thermistor mount calibration
A thermistor mount is a thermal radiofrequency (RF) power sensor that related to room temperature conditions. A precise measurement of the thermistor mount depends on the stability of ambient temperature. The unstable fluctuation of ambient temperature contributed to considerable measurement uncertainty of calibration factor (CF) of thermistor mount. A temperature control system is used to decrease the measurement uncertainty. The temperature control system consists of several devices, namely a heating block, a proportional integral derivative (PID) controller, Peltier elements, a temperature sensor, and a circulation of water. The design resulted in a stable temperature, and the fluctuation is kept stable around ± 0.1°C. Measurement repeatability of RF power of thermistor mount was much better by using the temperature control system. Measurement uncertainty of the CF was decreased from 0.045 to 0.020 in the range up to 18 GHz. The temperature control system has improved the measurement uncertainty of the CF of the thermistor mount.
- Open Access
- 31 December 2021
- Published by Center for Research and Development of Standardization and Conformity Assessment in Instrumentasi
- Vol. 45 (2) , 163-173
INDUCTANCE VALIDATION OF LCR METER AFTER RECALIBRATION
Laboratory of National Measurement Standard for Electricity and Time (NMS ET Lab) has validated the measurement results pre and post the LCR meter recalibration process on inductance parameters. The validation process was carried out at nominal values of 100 μH, 1 mH, 10 mH, 100 mH and 1 H in accordance to the reference standards. The direct measurement method was used to measure the inductance parameter of LCR meter with standard inductor. Validation is carried out by comparing the measurement results pre and post the LCR meter recalibration process at SCL - Hong Kong. Based on the En number analysis, the values between -0.21 to 0.44 were obtained for 5 measurement points, therefore the calibration system and method used by NMS ET Lab are valid and have measurement results that are equivalent to other countries.
- 31 December 2021
- Published by Center for Research and Development of Standardization and Conformity Assessment in Instrumentasi
- Vol. 45 (2) , 163-173
Open AccessINDUCTANCE VALIDATION OF LCR METER AFTER RECALIBRATION
Laboratory of National Measurement Standard for Electricity and Time (NMS ET Lab) has validated the measurement results pre and post the LCR meter recalibration process on inductance parameters. The validation process was carried out at nominal values of 100 μH, 1 mH, 10 mH, 100 mH and 1 H in accordance to the reference standards. The direct measurement method was used to measure the inductance parameter of LCR meter with standard inductor. Validation is carried out by comparing the measurement results pre and post the LCR meter recalibration process at SCL - Hong Kong. Based on the En number analysis, the values between -0.21 to 0.44 were obtained for 5 measurement points, therefore the calibration system and method used by NMS ET Lab are valid and have measurement results that are equivalent to other countries.
- Open Access
- 27 December 2019
- Published by Center for Research and Development of Standardization and Conformity Assessment in Pertemuan dan Presentasi Ilmiah Standardisasi
- Vol. 2019, 317-322
Uji Keseragaman dan Kestabilan Bak Air Sebagai Media Kalibrasi Termometer Telinga
- 27 December 2019
- Published by Center for Research and Development of Standardization and Conformity Assessment in Pertemuan dan Presentasi Ilmiah Standardisasi
- Vol. 2019, 317-322
Open AccessUji Keseragaman dan Kestabilan Bak Air Sebagai Media Kalibrasi Termometer Telinga