NSNik Stoyanov

Nik Stoyanov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nik Stoyanov has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The relationship between time to urgent or emergency pacemaker implantation and entry into residential aged care or death in older adults

    by Diane Nguyen, Madeleine Landwehr, Caitlyn Taylor, Eng Sim, Stephen Bacchi, Graham S. Hillis, Leon Flicker, Carl Schultz, Lucy Kilshaw, Nikola Stoyanov, et al.

    Background: Older adults often require permanent pacemaker (PPM) insertion. Delays to PPM insertion may associate with poor health outcomes. Aims: To investigate the association between delayed PPM insertion and adverse outcomes in older adults. Methods: Patients aged ≥65 years who underwent non-elective inpatient PPM insertion at Royal Perth Hospital between April 2019 and January 2022 were included in this retrospective cohort study. The relationship between time from admission to PPM insertion (exposure) and death or residential aged care facility (RACF) admission was examined using Cox modelling. Results: In 375 patients, with a mean age of 80.8±7.5 years, the median [25th – 75th ] duration from admission to PPM insertion was 47 [22–90] hours. Time from admission to PPM insertion (days) was associated with an increased risk of death at 1635 [1048–1931] days follow-up in univariate regression models (HR 1.05, 95% CI [1.03–1.07], p < 0.001) and after adjusting for comorbidities, demographics, clinical presentation characteristics and number of inpatient complications (HR 1.03 [1.00–1.05], p = 0.027). Time from admission to PPM insertion was associated with an increased risk of RACF admission at 1789 [1546–2128] days follow-up in univariate (HR 1.03 [1.00–1.07], p = 0.049), but not in multivariable regression models (HR 1.00 [0.96–1.04], p = 0.92). Discussion: These findings support the existing literature associating delays to medical intervention and poor health outcomes in older adults. Conclusion: In older adults, prolonged time from admission to PPM insertion was associated with higher mortality. Future research is needed to determine if reducing time to PPM insertion may improve their health outcomes.


  • Open Access

    Observable Atrial and Ventricular Fibrillation Episode Durations Are Conformant With a Power Law Based on System Size and Spatial Synchronization

    by Dhani Dharmaprani, Kathryn Tiver, Sobhan Salari Shahrbabaki, Evan V. Jenkins, Darius Chapman, Campbell Strong, Jing X. Quah, Ivaylo Tonchev, Luke O’loughlin, Lewis Mitchell, et al.

    BACKGROUND: Atrial fibrillation (AF) and ventricular fibrillation (VF) episodes exhibit varying durations, with some spontaneously ending quickly while others persist. A quantitative framework to explain episode durations remains elusive. We hypothesized that observable self-terminating AF and VF episode lengths, whereby durations are known, would conform with a power law based on the ratio of system size and correlation length ( L / ξ ) . METHODS: Using data from computer simulations (2-dimensional sheet and 3-dimensional left-atrial), human ischemic VF recordings (256-electrode sock, n=12 patients), and human AF recordings (64-electrode basket-catheter, n=9 patients; 16-electrode high definition-grid catheter, n=42 patients), conformance with a power law was assessed using the Akaike information criterion, Bayesian information criterion, coefficient of determination (R 2 , significance= P L / ξ , computed by taking the ratio between system size ( L , chamber/simulation size) and correlation length (xi, estimated from pairwise correlation coefficients over electrode/node distance). RESULTS: In all computer models, the relationship between episode durations and L / ξ was conformant with a power law (Aliev-Panfilov R 2 : 0.90, P 2 : 0.91, P 2 : 0.61, P 2 : 0.86, P 2 : 0.91, P 2 : 0.92, P L / ξ also differentiated between self-terminating and sustained episodes of AF and VF ( P P 0.05). CONCLUSIONS: Observable fibrillation episode durations are conformant with a power law based on system size and correlation length.


  • Open Access

    Lead-Specific Features Predisposing to the Development of Tricuspid Regurgitation After Endocardial Lead Implantation

    by Kalilur Anvardeen, Rajeev Rao, Samir Hazra, Karen Hay, Hongyan Dai, Nik Stoyanov, David Birnie, Girish Dwivedi, Kwan Leung Chan


  • Interrupted aorta diagnosed in a 51-year-old woman

    by Nik Stoyanov, Andrew Bullock, Matthew Erickson

    A 51-year-old lady presented with increasing heart failure symptoms and palpitations. She had recently been diagnosed with a congenital ventricular septal defect, bicuspid aortic valve, and Eisenmenger’s syndrome. There was clinical evidence of right heart failure and differential clubbing and cyanosis affecting the feet but not hands. A cardiac magnetic resonance imaging demonstrated interruption of the aortic arch beyond the left subclavian artery, with the descending aorta perfused entirely through a large patent ductus arteriosus.