Nik Stoyanov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nik Stoyanov has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Anand Narayan Ganesan
Flinders University
1 shared publication - Andrew Bullock
Children's Cardiac Centre, Princess Margaret Hospital for Children, Perth, Australia
1 shared publication Caitlyn Taylor
Department of Geriatrics, Royal Perth Hospital, Perth, Australia
1 shared publication- Campbell Strong
College of Medicine and Public Health, Flinders University (D.D., K.T., S.S.S., E.V.J., D.C., C.S., J.X.Q., I.T., A.N.G.).
1 shared publication - Carl Schultz
Department of Cardiology, Royal Perth Hospital, Perth, Australia
1 shared publication - Caroline Helen Roney
Queen Mary University of London
1 shared publication
Latest Publications
- Open Access
- 7 June 2026
- Published by Springer Nature in Aging Clinical and Experimental Research
- Vol. 38 (1)
The relationship between time to urgent or emergency pacemaker implantation and entry into residential aged care or death in older adults
Background: Older adults often require permanent pacemaker (PPM) insertion. Delays to PPM insertion may associate with poor health outcomes. Aims: To investigate the association between delayed PPM insertion and adverse outcomes in older adults. Methods: Patients aged ≥65 years who underwent non-elective inpatient PPM insertion at Royal Perth Hospital between April 2019 and January 2022 were included in this retrospective cohort study. The relationship between time from admission to PPM insertion (exposure) and death or residential aged care facility (RACF) admission was examined using Cox modelling. Results: In 375 patients, with a mean age of 80.8±7.5 years, the median [25th – 75th ] duration from admission to PPM insertion was 47 [22–90] hours. Time from admission to PPM insertion (days) was associated with an increased risk of death at 1635 [1048–1931] days follow-up in univariate regression models (HR 1.05, 95% CI [1.03–1.07], p < 0.001) and after adjusting for comorbidities, demographics, clinical presentation characteristics and number of inpatient complications (HR 1.03 [1.00–1.05], p = 0.027). Time from admission to PPM insertion was associated with an increased risk of RACF admission at 1789 [1546–2128] days follow-up in univariate (HR 1.03 [1.00–1.07], p = 0.049), but not in multivariable regression models (HR 1.00 [0.96–1.04], p = 0.92). Discussion: These findings support the existing literature associating delays to medical intervention and poor health outcomes in older adults. Conclusion: In older adults, prolonged time from admission to PPM insertion was associated with higher mortality. Future research is needed to determine if reducing time to PPM insertion may improve their health outcomes.
- 7 June 2026
- Published by Springer Nature in Aging Clinical and Experimental Research
- Vol. 38 (1)
Open AccessThe relationship between time to urgent or emergency pacemaker implantation and entry into residential aged care or death in older adults
Background: Older adults often require permanent pacemaker (PPM) insertion. Delays to PPM insertion may associate with poor health outcomes. Aims: To investigate the association between delayed PPM insertion and adverse outcomes in older adults. Methods: Patients aged ≥65 years who underwent non-elective inpatient PPM insertion at Royal Perth Hospital between April 2019 and January 2022 were included in this retrospective cohort study. The relationship between time from admission to PPM insertion (exposure) and death or residential aged care facility (RACF) admission was examined using Cox modelling. Results: In 375 patients, with a mean age of 80.8±7.5 years, the median [25th – 75th ] duration from admission to PPM insertion was 47 [22–90] hours. Time from admission to PPM insertion (days) was associated with an increased risk of death at 1635 [1048–1931] days follow-up in univariate regression models (HR 1.05, 95% CI [1.03–1.07], p < 0.001) and after adjusting for comorbidities, demographics, clinical presentation characteristics and number of inpatient complications (HR 1.03 [1.00–1.05], p = 0.027). Time from admission to PPM insertion was associated with an increased risk of RACF admission at 1789 [1546–2128] days follow-up in univariate (HR 1.03 [1.00–1.07], p = 0.049), but not in multivariable regression models (HR 1.00 [0.96–1.04], p = 0.92). Discussion: These findings support the existing literature associating delays to medical intervention and poor health outcomes in older adults. Conclusion: In older adults, prolonged time from admission to PPM insertion was associated with higher mortality. Future research is needed to determine if reducing time to PPM insertion may improve their health outcomes.
- Open Access
- 1 July 2024
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 17 (7) , e012684
Observable Atrial and Ventricular Fibrillation Episode Durations Are Conformant With a Power Law Based on System Size and Spatial Synchronization
BACKGROUND: Atrial fibrillation (AF) and ventricular fibrillation (VF) episodes exhibit varying durations, with some spontaneously ending quickly while others persist. A quantitative framework to explain episode durations remains elusive. We hypothesized that observable self-terminating AF and VF episode lengths, whereby durations are known, would conform with a power law based on the ratio of system size and correlation length ( L / ξ ) . METHODS: Using data from computer simulations (2-dimensional sheet and 3-dimensional left-atrial), human ischemic VF recordings (256-electrode sock, n=12 patients), and human AF recordings (64-electrode basket-catheter, n=9 patients; 16-electrode high definition-grid catheter, n=42 patients), conformance with a power law was assessed using the Akaike information criterion, Bayesian information criterion, coefficient of determination (R 2 , significance= P L / ξ , computed by taking the ratio between system size ( L , chamber/simulation size) and correlation length (xi, estimated from pairwise correlation coefficients over electrode/node distance). RESULTS: In all computer models, the relationship between episode durations and L / ξ was conformant with a power law (Aliev-Panfilov R 2 : 0.90, P 2 : 0.91, P 2 : 0.61, P 2 : 0.86, P 2 : 0.91, P 2 : 0.92, P L / ξ also differentiated between self-terminating and sustained episodes of AF and VF ( P P 0.05). CONCLUSIONS: Observable fibrillation episode durations are conformant with a power law based on system size and correlation length.
- 1 July 2024
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 17 (7) , e012684
Open AccessObservable Atrial and Ventricular Fibrillation Episode Durations Are Conformant With a Power Law Based on System Size and Spatial Synchronization
BACKGROUND: Atrial fibrillation (AF) and ventricular fibrillation (VF) episodes exhibit varying durations, with some spontaneously ending quickly while others persist. A quantitative framework to explain episode durations remains elusive. We hypothesized that observable self-terminating AF and VF episode lengths, whereby durations are known, would conform with a power law based on the ratio of system size and correlation length ( L / ξ ) . METHODS: Using data from computer simulations (2-dimensional sheet and 3-dimensional left-atrial), human ischemic VF recordings (256-electrode sock, n=12 patients), and human AF recordings (64-electrode basket-catheter, n=9 patients; 16-electrode high definition-grid catheter, n=42 patients), conformance with a power law was assessed using the Akaike information criterion, Bayesian information criterion, coefficient of determination (R 2 , significance= P L / ξ , computed by taking the ratio between system size ( L , chamber/simulation size) and correlation length (xi, estimated from pairwise correlation coefficients over electrode/node distance). RESULTS: In all computer models, the relationship between episode durations and L / ξ was conformant with a power law (Aliev-Panfilov R 2 : 0.90, P 2 : 0.91, P 2 : 0.61, P 2 : 0.86, P 2 : 0.91, P 2 : 0.92, P L / ξ also differentiated between self-terminating and sustained episodes of AF and VF ( P P 0.05). CONCLUSIONS: Observable fibrillation episode durations are conformant with a power law based on system size and correlation length.
- 15 October 2013
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 24 (5) , 944-946
Interrupted aorta diagnosed in a 51-year-old woman
A 51-year-old lady presented with increasing heart failure symptoms and palpitations. She had recently been diagnosed with a congenital ventricular septal defect, bicuspid aortic valve, and Eisenmenger’s syndrome. There was clinical evidence of right heart failure and differential clubbing and cyanosis affecting the feet but not hands. A cardiac magnetic resonance imaging demonstrated interruption of the aortic arch beyond the left subclavian artery, with the descending aorta perfused entirely through a large patent ductus arteriosus.
- 15 October 2013
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 24 (5) , 944-946
Interrupted aorta diagnosed in a 51-year-old woman
A 51-year-old lady presented with increasing heart failure symptoms and palpitations. She had recently been diagnosed with a congenital ventricular septal defect, bicuspid aortic valve, and Eisenmenger’s syndrome. There was clinical evidence of right heart failure and differential clubbing and cyanosis affecting the feet but not hands. A cardiac magnetic resonance imaging demonstrated interruption of the aortic arch beyond the left subclavian artery, with the descending aorta perfused entirely through a large patent ductus arteriosus.