Tim Sebastian Peltz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tim Sebastian Peltz has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- William Robert Walsh
Surgical and Orthopedic Research Laboratories (SORL), Prince of Wales Clinical School, Faculty of Medicine, Prince of Wales Clinical School, University of New South Wales (UNSW) Sydney New South Wales Australia
9 shared publications Roger Haddad
Surgical & Orthopaedic Research Laboratories, University of New South Wales, Australia
6 shared publicationsMark Gianoutsos
Sydney Children's Hospital Randwick New South Wales Australia
3 shared publicationsSean Nicklin
Surgical & Orthopaedic Research Laboratories, University of New South Wales, Australia
3 shared publicationsJeremy Hunt
University of New South Wales Kensington New South Wales Australia
2 shared publicationsMark Peter Gianoutsos
Surgical & Orthopaedic Research Laboratories, Prince of Wales Clinical School, University of New South Wales, Sydney, Australia
2 shared publications
Latest Publications
- Open Access
- 9 April 2024
- Published by Australian Society of Plastic Surgeons in Australasian Journal of Plastic Surgery
- Vol. 7 (1) , 1-7
Robotic surgery in plastic surgery: a review of its potential
"Background: Robotic surgery currently offers a number of benefits in specific areas of plastic and reconstructive surgery such as head and neck and microsurgery, however, many subspecialties are yet to benefit from robotic operating techniques. In this paper we review recent developments in the use of robotics for head and neck, breast reconstruction, microneural, lymphoedema, craniofacial and aesthetic surgery. Methods: A literature review of English-only articles on the use of robots in plastic and reconstructive surgery was conducted using the PubMed and Web of Science databases along with a free text search using the terms ‘robotic surgery plastic surgery’, ‘robotic-assisted plastic surgery’, ‘robot-assisted reconstructive surgery’, ‘da Vinci plastic surgery’, ‘da Vinci reconstructive surgery’ and ‘supermicrosurgery’. No limitation was placed on time from publication. Results: Of the studies reviewed, the most beneficial to reconstructive surgery is the area of the head and neck, with the most common procedures being transoral surgeries and microvascular procedures. Robotic assisted breast reconstructive surgery is a promising field. The main current limitations are the lack of adequate microsurgical instrumentation and the prolonged setting-up and operative time. Conclusion: As technology improves the outlook for robotic surgery is optimistic. Areas like microsurgery, head and neck, cleft palate, breast reconstructive surgery, lymphatic and microneural surgery already demonstrate promising results. Further technological advances and evidence-based studies are necessary to address current limitations such as appropriate microsurgical instrumentation, high costs and prolonged operative time."
- 9 April 2024
- Published by Australian Society of Plastic Surgeons in Australasian Journal of Plastic Surgery
- Vol. 7 (1) , 1-7
Open AccessRobotic surgery in plastic surgery: a review of its potential
"Background: Robotic surgery currently offers a number of benefits in specific areas of plastic and reconstructive surgery such as head and neck and microsurgery, however, many subspecialties are yet to benefit from robotic operating techniques. In this paper we review recent developments in the use of robotics for head and neck, breast reconstruction, microneural, lymphoedema, craniofacial and aesthetic surgery. Methods: A literature review of English-only articles on the use of robots in plastic and reconstructive surgery was conducted using the PubMed and Web of Science databases along with a free text search using the terms ‘robotic surgery plastic surgery’, ‘robotic-assisted plastic surgery’, ‘robot-assisted reconstructive surgery’, ‘da Vinci plastic surgery’, ‘da Vinci reconstructive surgery’ and ‘supermicrosurgery’. No limitation was placed on time from publication. Results: Of the studies reviewed, the most beneficial to reconstructive surgery is the area of the head and neck, with the most common procedures being transoral surgeries and microvascular procedures. Robotic assisted breast reconstructive surgery is a promising field. The main current limitations are the lack of adequate microsurgical instrumentation and the prolonged setting-up and operative time. Conclusion: As technology improves the outlook for robotic surgery is optimistic. Areas like microsurgery, head and neck, cleft palate, breast reconstructive surgery, lymphatic and microneural surgery already demonstrate promising results. Further technological advances and evidence-based studies are necessary to address current limitations such as appropriate microsurgical instrumentation, high costs and prolonged operative time."
- Open Access
- 29 September 2022
- Published by Australian Society of Plastic Surgeons in Australasian Journal of Plastic Surgery
- Vol. 5 (2) , 23-28
ATX-101 (deoxycholic acid injection) in submental fat reduction: an objective outcome study
**Background**: ATX-101 (deoxycholic acid injection) causes irreversible adipocytolysis and has been studied in multiple clinical trials. It is a Therapeutic Goods and Administration (TGA) approved treatment for minimally invasive reduction of excess submental fat. We present a case series of four consecutive patients who underwent serial ATX-101 (treatment sessions). **Methods**: Each patient underwent between three and four injection sessions with ATX-101 according to manufacturer’s recommendations, spaced six weeks apart. High resolution 3D surface scans were performed pre- and post-ATX-101 treatment and a FACE-Q survey was also completed pre- and post-treatment. **Results**: The submental profiles for each patient were analysed pre- and post-treatment. These demonstrated a mean reduction of the maximum submental fat pad thickness of 4 mm. FACE-Q surveys showed improvement in patient satisfaction in their submental ap-pearance. Apart from pain associated with the injection of ATX-101, we did not encounter other adverse reactions in our patient group.**Conclusions**: This is the first study to analyse the outcome of ATX-101 using high resolution surface scans of the submental area. The reduction in thickness of the submental fat by 4 mm demonstrates clinical effectiveness of ATX-101 in treatment of excess submental fat six weeks after treatment.
- 29 September 2022
- Published by Australian Society of Plastic Surgeons in Australasian Journal of Plastic Surgery
- Vol. 5 (2) , 23-28
Open AccessATX-101 (deoxycholic acid injection) in submental fat reduction: an objective outcome study
**Background**: ATX-101 (deoxycholic acid injection) causes irreversible adipocytolysis and has been studied in multiple clinical trials. It is a Therapeutic Goods and Administration (TGA) approved treatment for minimally invasive reduction of excess submental fat. We present a case series of four consecutive patients who underwent serial ATX-101 (treatment sessions). **Methods**: Each patient underwent between three and four injection sessions with ATX-101 according to manufacturer’s recommendations, spaced six weeks apart. High resolution 3D surface scans were performed pre- and post-ATX-101 treatment and a FACE-Q survey was also completed pre- and post-treatment. **Results**: The submental profiles for each patient were analysed pre- and post-treatment. These demonstrated a mean reduction of the maximum submental fat pad thickness of 4 mm. FACE-Q surveys showed improvement in patient satisfaction in their submental ap-pearance. Apart from pain associated with the injection of ATX-101, we did not encounter other adverse reactions in our patient group.**Conclusions**: This is the first study to analyse the outcome of ATX-101 using high resolution surface scans of the submental area. The reduction in thickness of the submental fat by 4 mm demonstrates clinical effectiveness of ATX-101 in treatment of excess submental fat six weeks after treatment.
- 28 September 2022
- Published by World Scientific Pub Co Pte Ltd in The Journal of Hand Surgery (Asian-Pacific Volume)
- Vol. 27 (05) , 816-823
Cyclic Testing of a Modified Pull-Out Suture Repair Technique for Flexor Digitorum Profundus Avulsion in a Turkey Foot Model
Background: Numerous repair techniques have been described for closed flexor digitorum profundus (FDP) avulsion. One option is a pull-out suture tied over the nail plate (Bunnell repair). We modified the Bunnell repair by incorporating a portion of the distal interphalangeal (DIP) joint volar plate into the repair to improve strength and reduce gapping. The aim of this study is to compare gap formation and load to failure between the Bunnell repair and our modification in a turkey foot model. Methods: Twenty-four fresh-frozen cadaveric turkey feet were divided into two repair groups namely the conventional Bunnell pull-out suture technique and the modified Bunnell pull-out suture technique, incorporating the middle-third of the DIP joint volar plate into the repair. Both repairs were carried out with 3-0 prolene suture and underwent ex-vivo cyclic loading at 2-12 n in a sinusoidal wave for 100 cycles to simulate a passive range of motion (ROM) protocol. Subsequently, specimens were loaded to failure at 12 mm/minute. Gap formation and load to failure were measured. Results: No repair ruptures occurred during cyclical testing. Mean gap formation was 9.2 mm (±1.49) in the Bunnell repair, and 3.5 mm (±1.19) in the modified Bunnell repair (p < 0.0001). The mean load to failure for the Bunnell repair was 35.4 n compared to 45 n for the modified repair (p = 0.0017). Conclusions: Gap formation was reduced and load to failure increased by augmenting the Bunnell pull-out suture repair with the central portion of the DIP joint volar plate.
- 28 September 2022
- Published by World Scientific Pub Co Pte Ltd in The Journal of Hand Surgery (Asian-Pacific Volume)
- Vol. 27 (05) , 816-823
Cyclic Testing of a Modified Pull-Out Suture Repair Technique for Flexor Digitorum Profundus Avulsion in a Turkey Foot Model
Background: Numerous repair techniques have been described for closed flexor digitorum profundus (FDP) avulsion. One option is a pull-out suture tied over the nail plate (Bunnell repair). We modified the Bunnell repair by incorporating a portion of the distal interphalangeal (DIP) joint volar plate into the repair to improve strength and reduce gapping. The aim of this study is to compare gap formation and load to failure between the Bunnell repair and our modification in a turkey foot model. Methods: Twenty-four fresh-frozen cadaveric turkey feet were divided into two repair groups namely the conventional Bunnell pull-out suture technique and the modified Bunnell pull-out suture technique, incorporating the middle-third of the DIP joint volar plate into the repair. Both repairs were carried out with 3-0 prolene suture and underwent ex-vivo cyclic loading at 2-12 n in a sinusoidal wave for 100 cycles to simulate a passive range of motion (ROM) protocol. Subsequently, specimens were loaded to failure at 12 mm/minute. Gap formation and load to failure were measured. Results: No repair ruptures occurred during cyclical testing. Mean gap formation was 9.2 mm (±1.49) in the Bunnell repair, and 3.5 mm (±1.19) in the modified Bunnell repair (p < 0.0001). The mean load to failure for the Bunnell repair was 35.4 n compared to 45 n for the modified repair (p = 0.0017). Conclusions: Gap formation was reduced and load to failure increased by augmenting the Bunnell pull-out suture repair with the central portion of the DIP joint volar plate.
- Open Access
- 1 April 2019
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery - Global Open
- Vol. 7 (4) , e2171
Quantification of Head Shape and Cranioplasty Outcomes: Six-compartment Volume Method Applied to Sagittal Synostosis
Background: Premature fusion of the sagittal (midline) suture between 2 parietal bones is the most common form of craniosynostosis. Surgical correction is mandated to improve head shape and to decrease the risk of raised intracranial pressure. This study evaluated the utility of 3-dimensional (3D) imaging to quantify the volumetric changes of surgical correction. Currently there is no standardized method used to quantify the outcomes of surgery for craniosynostosis, with the cranial index (width: length ratio) being commonly used. Methods: A method for quantification of head shape using 3D imaging is described in which the cranium is divided up into 6 compartments and the volumes of 6 compartments are quantified and analyzed. The method is size invariant, meaning that it can be used to assess the long-term postoperative outcomes of patients through growth. The method is applied to a cohort of sagittal synostosis patients and a normal cohort, and is used to follow up a smaller group of synostotic patients 1, 2, and 3 years postoperatively. Results: Statistical analysis of the results shows that the 6-compartment volume quantification method is more accurate in separating normal from synostotic patient head shapes than the cranial index. Conclusions: Spring-mediated cranioplasty does not return head shape back to normal, but results in significant improvements in the first year following surgery compared with the preoperative sagittal synostosis head shape. 3D imaging can be a valuable tool in assessing the volumetric changes due to surgery and growth in craniosynstosis patients.
- 1 April 2019
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery - Global Open
- Vol. 7 (4) , e2171
Open AccessQuantification of Head Shape and Cranioplasty Outcomes: Six-compartment Volume Method Applied to Sagittal Synostosis
Background: Premature fusion of the sagittal (midline) suture between 2 parietal bones is the most common form of craniosynostosis. Surgical correction is mandated to improve head shape and to decrease the risk of raised intracranial pressure. This study evaluated the utility of 3-dimensional (3D) imaging to quantify the volumetric changes of surgical correction. Currently there is no standardized method used to quantify the outcomes of surgery for craniosynostosis, with the cranial index (width: length ratio) being commonly used. Methods: A method for quantification of head shape using 3D imaging is described in which the cranium is divided up into 6 compartments and the volumes of 6 compartments are quantified and analyzed. The method is size invariant, meaning that it can be used to assess the long-term postoperative outcomes of patients through growth. The method is applied to a cohort of sagittal synostosis patients and a normal cohort, and is used to follow up a smaller group of synostotic patients 1, 2, and 3 years postoperatively. Results: Statistical analysis of the results shows that the 6-compartment volume quantification method is more accurate in separating normal from synostotic patient head shapes than the cranial index. Conclusions: Spring-mediated cranioplasty does not return head shape back to normal, but results in significant improvements in the first year following surgery compared with the preoperative sagittal synostosis head shape. 3D imaging can be a valuable tool in assessing the volumetric changes due to surgery and growth in craniosynstosis patients.
- 4 August 2017
- Published by World Scientific Pub Co Pte Ltd in The Journal of Hand Surgery (Asian-Pacific Volume)
- Vol. 22 (03) , 329-336
Animal Models for Tendon Repair Experiments: A Comparison of Pig, Sheep and Human Deep Flexor Tendons in Zone II
Background: This laboratory study compared pig, sheep and human deep flexor tendons in regards to their biomechanical comparability.Methods: To investigate the relevant biomechanical properties for tendon repair experiments, the tendons resistance to cheese-wiring (suture drag/splitting) was assessed. Cheese-wiring of a suture through a tendon is an essential factor for repair gapping and failure in a tendon repair.Results: Biomechanical testing showed that forces required to pulling a uniform suture loop through sheep or pig tendons in Zone II were higher than in human tendons. At time point zero of testing these differences did not reach statistical significance, but differences became more pronounced when forces were measured beyond initial cheese-wiring (2 mm, 5 mm and 10 mm). The stronger resistance to cheese-wiring was more pronounced in the pig tendons. Also regarding size and histology, sheep tendons were more comparable to human tendons than pig tendons.Conclusions: Differences in tendon bio-properties should be kept in mind when comparing and interpreting the results of laboratory tendon experiments.
- 4 August 2017
- Published by World Scientific Pub Co Pte Ltd in The Journal of Hand Surgery (Asian-Pacific Volume)
- Vol. 22 (03) , 329-336
Animal Models for Tendon Repair Experiments: A Comparison of Pig, Sheep and Human Deep Flexor Tendons in Zone II
Background: This laboratory study compared pig, sheep and human deep flexor tendons in regards to their biomechanical comparability.Methods: To investigate the relevant biomechanical properties for tendon repair experiments, the tendons resistance to cheese-wiring (suture drag/splitting) was assessed. Cheese-wiring of a suture through a tendon is an essential factor for repair gapping and failure in a tendon repair.Results: Biomechanical testing showed that forces required to pulling a uniform suture loop through sheep or pig tendons in Zone II were higher than in human tendons. At time point zero of testing these differences did not reach statistical significance, but differences became more pronounced when forces were measured beyond initial cheese-wiring (2 mm, 5 mm and 10 mm). The stronger resistance to cheese-wiring was more pronounced in the pig tendons. Also regarding size and histology, sheep tendons were more comparable to human tendons than pig tendons.Conclusions: Differences in tendon bio-properties should be kept in mind when comparing and interpreting the results of laboratory tendon experiments.
- 5 December 2016
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 42 (5) , 526-528
Evaluation of the artificial cotton roll tendon model for mechanical tendon repair experiments
- 5 December 2016
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 42 (5) , 526-528
Evaluation of the artificial cotton roll tendon model for mechanical tendon repair experiments
- 21 September 2015
- Published by World Scientific Pub Co Pte Ltd in Hand Surgery
- Vol. 20 (03) , 369-379
Structural Failure Mechanisms of Common Flexor Tendon Repairs
Background: This study investigated the exact failure mechanisms of the most commonly used conventional tendon repair techniques. A new method, radiographing repair constructs in antero-posterior and lateral projections before and after tensioning was used. This allowed to precisely analyse failure mechanisms in regards to geometrical changes in all three dimensions. Additionally the biomechanical stability focusing on gapping was tested. Methods: Sheep fore limb deep flexor tendons were harvested and divided in eight groups of ten tendons. Three common variants of the Kessler repair method and four common 4-strand repair techniques were tested. Additionally a new modification of the Adelaide repair was tested. Results: Biomechanical testing showed no significant differences in gapping for the three tested 2-strand Kessler repair groups. Once a double Kessler or 4-strand Kessler repair was performed the stability of the repair improved significantly. Further significant improvements in biomechanical stability could be achieved by using cross locks in the repair like in the Adelaide repair method. Qualitative analysis using radiographs showed that all Kessler repair variants unfolded via rotations around the transverse suturing component, no matter which variant was used. Conclusions: Additional to the commonly described constriction of the repair construct, the rotating deformation is the main reason for repair site gapping in Kessler tendon repair methods. The term “locking” in a Kessler repair is misleading. The cruciate repairs tended to loose grip and drag (cheese-wire) through the tendon and therefore lead to gapping. The most stable repair constructs in all three dimensions were the Adelaide repair and its interlocking modification. This is due to the superior anchoring qualities of its cross locks and three dimensional stability.
- 21 September 2015
- Published by World Scientific Pub Co Pte Ltd in Hand Surgery
- Vol. 20 (03) , 369-379
Structural Failure Mechanisms of Common Flexor Tendon Repairs
Background: This study investigated the exact failure mechanisms of the most commonly used conventional tendon repair techniques. A new method, radiographing repair constructs in antero-posterior and lateral projections before and after tensioning was used. This allowed to precisely analyse failure mechanisms in regards to geometrical changes in all three dimensions. Additionally the biomechanical stability focusing on gapping was tested. Methods: Sheep fore limb deep flexor tendons were harvested and divided in eight groups of ten tendons. Three common variants of the Kessler repair method and four common 4-strand repair techniques were tested. Additionally a new modification of the Adelaide repair was tested. Results: Biomechanical testing showed no significant differences in gapping for the three tested 2-strand Kessler repair groups. Once a double Kessler or 4-strand Kessler repair was performed the stability of the repair improved significantly. Further significant improvements in biomechanical stability could be achieved by using cross locks in the repair like in the Adelaide repair method. Qualitative analysis using radiographs showed that all Kessler repair variants unfolded via rotations around the transverse suturing component, no matter which variant was used. Conclusions: Additional to the commonly described constriction of the repair construct, the rotating deformation is the main reason for repair site gapping in Kessler tendon repair methods. The term “locking” in a Kessler repair is misleading. The cruciate repairs tended to loose grip and drag (cheese-wire) through the tendon and therefore lead to gapping. The most stable repair constructs in all three dimensions were the Adelaide repair and its interlocking modification. This is due to the superior anchoring qualities of its cross locks and three dimensional stability.
- 22 February 2013
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 39 (1) , 30-39
Performance of a knotless four-strand flexor tendon repair with a unidirectional barbed suture device: a dynamic ex vivo comparison
With increased numbers of reports using barbed sutures for tendon repairs we felt the need to design a specific tendon repair method to draw the best utility from these materials. We split 30 sheep deep flexor tendons in two groups of 15 tendons. One group was repaired with a new four-strand barbed suture repair method without knot. The other group was repaired with a conventional four-strand cross-locked cruciate repair method (Adelaide repair) with knot. Dynamic testing (3–30 N for 250 cycles) and additional static pull to failure was performed to investigate gap formation and final failure forces. The barbed suture repair group showed higher resistance to gap formation throughout the test. Additionally final failure force was higher for the barbed suture group compared with the conventional repair group. When used appropriately, barbed suture materials could be beneficial to use in tendon surgery, especially with regard to early loading of the repair site and gap formation.
- 22 February 2013
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 39 (1) , 30-39
Performance of a knotless four-strand flexor tendon repair with a unidirectional barbed suture device: a dynamic ex vivo comparison
With increased numbers of reports using barbed sutures for tendon repairs we felt the need to design a specific tendon repair method to draw the best utility from these materials. We split 30 sheep deep flexor tendons in two groups of 15 tendons. One group was repaired with a new four-strand barbed suture repair method without knot. The other group was repaired with a conventional four-strand cross-locked cruciate repair method (Adelaide repair) with knot. Dynamic testing (3–30 N for 250 cycles) and additional static pull to failure was performed to investigate gap formation and final failure forces. The barbed suture repair group showed higher resistance to gap formation throughout the test. Additionally final failure force was higher for the barbed suture group compared with the conventional repair group. When used appropriately, barbed suture materials could be beneficial to use in tendon surgery, especially with regard to early loading of the repair site and gap formation.
- 1 September 2011
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 36 (9) , 1565-1566
Biomechanical Evaluation of Flexor Tendon Repair Using Barbed Suture Material: A Comparative ex vivo Study
- 1 September 2011
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 36 (9) , 1565-1566