Léo Puyo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Léo Puyo has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Michael Atlan
Institut Langevin. Centre National de la Recherche Scientifique (CNRS). Paris Sciences & Lettres (PSL University). École Supérieure de Physique et de Chimie Industrielles (ESPCI Paris), Paris, France
10 shared publicationsMichel Paques
Centre Hospitalier National d’Ophtalmologie des Quinze-Vingts, Paris, France
10 shared publicationsClara Pfäffle
Institute of Biomedical Optics University of Lübeck Peter-Monnik-Weg 4 23562 Lübeck Germany
4 shared publicationsHendrik Spahr
Institute of Biomedical Optics University of Lübeck Peter-Monnik-Weg 4 23562 Lübeck Germany
4 shared publicationsJosé-Alain Sahel
Institut Langevin, Paris. Hôpital des 15-20. Paris, France
4 shared publicationsGereon Hüttmann
Institute of Biomedical Optics University of Lübeck Peter-Monnik-Weg 4 23562 Lübeck Germany
3 shared publications
Latest Publications
- Open Access
Measuring choriocapillaris blood flow with laser Doppler optical coherence tomography
We report on using a laser Doppler processing of Fourier-domain optical coherence tomography (OCT) data for the assessment of pulsatile blood flow in the choriocapillaris. Signal fluctuations in B-scans recorded at 2 kHz were analyzed by Fourier transform to extract blood flow information. The spectral broadening of light backscattered by the choriocapillaris was used to derive a choriocapillaris flow velocity index in physical units, with sufficient temporal resolution to capture heartbeat-induced variations. Furthermore, the asymmetry in the spectral broadening enabled us to determine the axial direction of blood flow with high sensitivity, allowing for the detection of flow orientation in retinal capillaries. This approach is promising as it can be directly implemented on widely available fast-scanning Fourier-domain OCT instruments.
Open AccessMeasuring choriocapillaris blood flow with laser Doppler optical coherence tomography
We report on using a laser Doppler processing of Fourier-domain optical coherence tomography (OCT) data for the assessment of pulsatile blood flow in the choriocapillaris. Signal fluctuations in B-scans recorded at 2 kHz were analyzed by Fourier transform to extract blood flow information. The spectral broadening of light backscattered by the choriocapillaris was used to derive a choriocapillaris flow velocity index in physical units, with sufficient temporal resolution to capture heartbeat-induced variations. Furthermore, the asymmetry in the spectral broadening enabled us to determine the axial direction of blood flow with high sensitivity, allowing for the detection of flow orientation in retinal capillaries. This approach is promising as it can be directly implemented on widely available fast-scanning Fourier-domain OCT instruments.
- Open Access
Diffuse-illumination holographic optical coherence tomography
Holographic optical coherence tomography (OCT) is a powerful imaging technique, but its ability to reveal low-reflectivity features is limited. In this study, we performed holographic OCT by incoherently averaging volumes with changing diffuse illumination of numerical aperture (NA) equal to the detection NA. While the reduction of speckle from singly scattered light is only modest, we discovered that speckle from multiply scattered light can be arbitrarily reduced, resulting in substantial improvements in image quality. This technique also offers the advantage of suppressing noises arising from spatial coherence, and can be implemented with a partially spatially incoherent light source for further mitigation of multiple scattering. Finally, we show that although holographic reconstruction capabilities are increasingly lost with decreasing spatial coherence, they can be retained over an axial range sufficient to standard OCT applications.
Open AccessDiffuse-illumination holographic optical coherence tomography
Holographic optical coherence tomography (OCT) is a powerful imaging technique, but its ability to reveal low-reflectivity features is limited. In this study, we performed holographic OCT by incoherently averaging volumes with changing diffuse illumination of numerical aperture (NA) equal to the detection NA. While the reduction of speckle from singly scattered light is only modest, we discovered that speckle from multiply scattered light can be arbitrarily reduced, resulting in substantial improvements in image quality. This technique also offers the advantage of suppressing noises arising from spatial coherence, and can be implemented with a partially spatially incoherent light source for further mitigation of multiple scattering. Finally, we show that although holographic reconstruction capabilities are increasingly lost with decreasing spatial coherence, they can be retained over an axial range sufficient to standard OCT applications.
- Open Access
Retinal blood flow imaging with combined full-field swept-source optical coherence tomography and laser Doppler holography
Full-field swept-source optical coherence tomography (FF-SS-OCT) and laser Doppler holography (LDH) are two holographic imaging techniques presenting unique capabilities for ophthalmology. We report on interlaced FF-SS-OCT and LDH imaging with a single instrument. Effectively, retinal blood flow and pulsation could be quasi-simultaneously monitored. This instrument holds potential for a wide scope of ophthalmic applications.
Open AccessRetinal blood flow imaging with combined full-field swept-source optical coherence tomography and laser Doppler holography
Full-field swept-source optical coherence tomography (FF-SS-OCT) and laser Doppler holography (LDH) are two holographic imaging techniques presenting unique capabilities for ophthalmology. We report on interlaced FF-SS-OCT and LDH imaging with a single instrument. Effectively, retinal blood flow and pulsation could be quasi-simultaneously monitored. This instrument holds potential for a wide scope of ophthalmic applications.
- 25 February 2022
- Published by Optica Publishing Group in Optics Letters
- Vol. 47 (5) , 1198-1201
Retinal blood flow imaging with combined full-field swept-source optical coherence tomography and laser Doppler holography
Full-field swept-source optical coherence tomography (FF-SS-OCT) and laser Doppler holography (LDH) are two holographic imaging techniques presenting unique capabilities for ophthalmology. We report on interlaced FF-SS-OCT and LDH imaging with a single instrument. Effectively, retinal blood flow and pulsation could be quasi-simultaneously monitored. This instrument holds potential for a wide scope of ophthalmic applications.
- 25 February 2022
- Published by Optica Publishing Group in Optics Letters
- Vol. 47 (5) , 1198-1201
Retinal blood flow imaging with combined full-field swept-source optical coherence tomography and laser Doppler holography
Full-field swept-source optical coherence tomography (FF-SS-OCT) and laser Doppler holography (LDH) are two holographic imaging techniques presenting unique capabilities for ophthalmology. We report on interlaced FF-SS-OCT and LDH imaging with a single instrument. Effectively, retinal blood flow and pulsation could be quasi-simultaneously monitored. This instrument holds potential for a wide scope of ophthalmic applications.
- Open Access
- 8 September 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-14
Retinal blood flow reversal quantitatively monitored in out-of-plane vessels with laser Doppler holography
Laser Doppler holography is a planar blood flow imaging technique recently introduced in ophthalmology to image human retinal and choroidal blood flow non-invasively. Here we present a digital method based on the Doppler spectrum asymmetry that reveals the local direction of blood flow with respect to the optical axis in out-of-plane vessels. This directional information is overlaid on standard grayscale blood flow images to depict flow moving towards the camera in red and flow moving away from the camera in blue, as in ultrasound color Doppler imaging. We show that thanks to the strong contribution of backscattering to the Doppler spectrum in out-of-plane vessels, the local axial direction of blood flow can be revealed with a high temporal resolution, which enables us to evidence pathological blood flow reversals. We also demonstrate the use of optical Doppler spectrograms to quantitatively monitor retinal blood flow reversals.
- 8 September 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-14
Open AccessRetinal blood flow reversal quantitatively monitored in out-of-plane vessels with laser Doppler holography
Laser Doppler holography is a planar blood flow imaging technique recently introduced in ophthalmology to image human retinal and choroidal blood flow non-invasively. Here we present a digital method based on the Doppler spectrum asymmetry that reveals the local direction of blood flow with respect to the optical axis in out-of-plane vessels. This directional information is overlaid on standard grayscale blood flow images to depict flow moving towards the camera in red and flow moving away from the camera in blue, as in ultrasound color Doppler imaging. We show that thanks to the strong contribution of backscattering to the Doppler spectrum in out-of-plane vessels, the local axial direction of blood flow can be revealed with a high temporal resolution, which enables us to evidence pathological blood flow reversals. We also demonstrate the use of optical Doppler spectrograms to quantitatively monitor retinal blood flow reversals.
- Open Access
Retinal blood flow reversal quantitatively monitored in out-of-plane vessels with laser Doppler holography
Laser Doppler holography is a planar blood flow imaging technique recently introduced in ophthalmology to image human retinal and choroidal blood flow non-invasively. Here we present a digital method based on the Doppler spectrum asymmetry that reveals the local direction of blood flow with respect to the optical axis in out-of-plane vessels. This directional information is overlaid on standard grayscale blood flow images to depict flow moving towards the camera in red and flow moving away from the camera in blue, as in ultrasound color Doppler imaging. We show that thanks to the strong contribution of backscattering to the Doppler spectrum in out-of-plane vessels, the local axial direction of blood flow can be revealed with a high temporal resolution, which enables us to evidence pathological blood flow reversals. We also demonstrate the use of optical Doppler spectrograms to quantitatively monitor retinal blood flow reversals.
Open AccessRetinal blood flow reversal quantitatively monitored in out-of-plane vessels with laser Doppler holography
Laser Doppler holography is a planar blood flow imaging technique recently introduced in ophthalmology to image human retinal and choroidal blood flow non-invasively. Here we present a digital method based on the Doppler spectrum asymmetry that reveals the local direction of blood flow with respect to the optical axis in out-of-plane vessels. This directional information is overlaid on standard grayscale blood flow images to depict flow moving towards the camera in red and flow moving away from the camera in blue, as in ultrasound color Doppler imaging. We show that thanks to the strong contribution of backscattering to the Doppler spectrum in out-of-plane vessels, the local axial direction of blood flow can be revealed with a high temporal resolution, which enables us to evidence pathological blood flow reversals. We also demonstrate the use of optical Doppler spectrograms to quantitatively monitor retinal blood flow reversals.
- 28 June 2021
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 12 (7) , 4478-4495
Laser Doppler holography of the anterior segment for blood flow imaging, eye tracking, and transparency assessment
Laser Doppler holography (LDH) is a full-field blood flow imaging technique able to reveal human retinal and choroidal blood flow with high temporal resolution. We here report on using LDH in the anterior segment of the eye without making changes to the instrument. Blood flow in the bulbar conjunctiva and episclera as well as in corneal neovascularization can be effectively imaged. We additionally demonstrate simultaneous holographic imaging of the anterior and posterior segments by simply adapting the numerical propagation distance to the plane of interest. We used this feature to track the movements of the retina and pupil with high temporal resolution. Finally, we show that the light backscattered by the retina can be used for retro-illumination of the anterior segment. Hence digital holography can reveal opacities caused by absorption or diffusion in the cornea and eye lens.
- 28 June 2021
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 12 (7) , 4478-4495
Laser Doppler holography of the anterior segment for blood flow imaging, eye tracking, and transparency assessment
Laser Doppler holography (LDH) is a full-field blood flow imaging technique able to reveal human retinal and choroidal blood flow with high temporal resolution. We here report on using LDH in the anterior segment of the eye without making changes to the instrument. Blood flow in the bulbar conjunctiva and episclera as well as in corneal neovascularization can be effectively imaged. We additionally demonstrate simultaneous holographic imaging of the anterior and posterior segments by simply adapting the numerical propagation distance to the plane of interest. We used this feature to track the movements of the retina and pupil with high temporal resolution. Finally, we show that the light backscattered by the retina can be used for retro-illumination of the anterior segment. Hence digital holography can reveal opacities caused by absorption or diffusion in the cornea and eye lens.
- 13 July 2020
- Published by Optica Publishing Group in Optics Letters
- Vol. 45 (14) , 4012-4015
Reverse contrast laser Doppler holography for lower frame rate retinal and choroidal blood flow imaging
Laser Doppler holography (LDH) is an interferometric blood flow imaging technique based on full-field measurements of the Doppler spectrum. LDH has so far been demonstrated in the retina with ultrafast cameras, typically at 75 kHz. We show here that a similar method can be implemented with camera frame rates 10 times slower than before. Due to energy conservation, low and high frequency local power Doppler signals have opposite variations, and a simple contrast inversion of the low frequency power Doppler reveals fast blood flow beyond the camera detection bandwidth for conventional laser Doppler measurements. Relevant blood flow variations and color composite power Doppler images can be obtained with camera frame rates down to a few kHz.
- 13 July 2020
- Published by Optica Publishing Group in Optics Letters
- Vol. 45 (14) , 4012-4015
Reverse contrast laser Doppler holography for lower frame rate retinal and choroidal blood flow imaging
Laser Doppler holography (LDH) is an interferometric blood flow imaging technique based on full-field measurements of the Doppler spectrum. LDH has so far been demonstrated in the retina with ultrafast cameras, typically at 75 kHz. We show here that a similar method can be implemented with camera frame rates 10 times slower than before. Due to energy conservation, low and high frequency local power Doppler signals have opposite variations, and a simple contrast inversion of the low frequency power Doppler reveals fast blood flow beyond the camera detection bandwidth for conventional laser Doppler measurements. Relevant blood flow variations and color composite power Doppler images can be obtained with camera frame rates down to a few kHz.
- Open Access
Reverse contrast laser Doppler holography for lower frame rate retinal and choroidal blood flow imaging
Laser Doppler holography (LDH) is an interferometric blood flow imaging technique based on full-field measurements of the Doppler spectrum. LDH has so far been demonstrated in the retina with ultrafast cameras, typically at 75 kHz. We show here that a similar method can be implemented with camera frame rates 10 times slower than before. Thanks to energy conservation, low and high frequency local power Doppler signals have opposite variations, and a simple contrast inversion of the low frequency power Doppler reveals fast blood flow beyond the camera detection bandwidth for conventional laser Doppler measurements. Relevant blood flow variations and color composite power Doppler images can be obtained with camera frame rates down to a few kHz.
Open AccessReverse contrast laser Doppler holography for lower frame rate retinal and choroidal blood flow imaging
Laser Doppler holography (LDH) is an interferometric blood flow imaging technique based on full-field measurements of the Doppler spectrum. LDH has so far been demonstrated in the retina with ultrafast cameras, typically at 75 kHz. We show here that a similar method can be implemented with camera frame rates 10 times slower than before. Thanks to energy conservation, low and high frequency local power Doppler signals have opposite variations, and a simple contrast inversion of the low frequency power Doppler reveals fast blood flow beyond the camera detection bandwidth for conventional laser Doppler measurements. Relevant blood flow variations and color composite power Doppler images can be obtained with camera frame rates down to a few kHz.
- 26 May 2020
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 11 (6) , 3274-3287
Spatio-temporal filtering in laser Doppler holography for retinal blood flow imaging
Laser Doppler holography (LDH) is a full-field interferometric imaging technique recently applied in ophthalmology to measure blood flow, a parameter of high clinical interest. From the temporal fluctuations of digital holograms acquired at ultrafast frame rates, LDH reveals retinal and choroidal blood flow with a few milliseconds of temporal resolution. However, LDH experiences difficulties to detect slower blood flow as it requires to work with low Doppler frequency shifts which are corrupted by eye motion. We here demonstrate the use of a spatio-temporal decomposition adapted from Doppler ultrasound that provides a basis appropriate to the discrimination of blood flow from eye motion. A singular value decomposition (SVD) can be used as a simple, robust, and efficient way to separate the Doppler fluctuations of blood flow from those of strong spatial coherence such as eye motion. We show that the SVD outperforms the conventional Fourier based filter to reveal slower blood flow, and dramatically improves the ability of LDH to reveal vessels of smaller size or with a pathologically reduced blood flow.
- 26 May 2020
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 11 (6) , 3274-3287
Spatio-temporal filtering in laser Doppler holography for retinal blood flow imaging
Laser Doppler holography (LDH) is a full-field interferometric imaging technique recently applied in ophthalmology to measure blood flow, a parameter of high clinical interest. From the temporal fluctuations of digital holograms acquired at ultrafast frame rates, LDH reveals retinal and choroidal blood flow with a few milliseconds of temporal resolution. However, LDH experiences difficulties to detect slower blood flow as it requires to work with low Doppler frequency shifts which are corrupted by eye motion. We here demonstrate the use of a spatio-temporal decomposition adapted from Doppler ultrasound that provides a basis appropriate to the discrimination of blood flow from eye motion. A singular value decomposition (SVD) can be used as a simple, robust, and efficient way to separate the Doppler fluctuations of blood flow from those of strong spatial coherence such as eye motion. We show that the SVD outperforms the conventional Fourier based filter to reveal slower blood flow, and dramatically improves the ability of LDH to reveal vessels of smaller size or with a pathologically reduced blood flow.