MNMasato Nishimuta

Masato Nishimuta

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Masato Nishimuta has a total of 33 co-authors. Here are the top co-authors by number of shared publications:

  • Keitaro Matsumoto

    Division of Surgical Oncology, Department of Surgery, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan

    2 shared publications
  • Takashi Nonaka

    Department of Surgical Oncology, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Nagasaki, Japan

    2 shared publications
  • Akihiro Nakamura

    Department of Surgery, Sasebo City General Hospital, 9-3 Hirase, Sasebo, Nagasaki 857-8511, Japan

    1 shared publication
  • Ayako Shibuya

    Department of Surgery, Sasebo City General Hospital, 9-3 Hirase, Sasebo, Nagasaki 857-8511, Japan

    1 shared publication
  • Daisuke Taniguchi

    Department of Surgical Oncology, Nagasaki University Graduate School of Biomedical Sciences , Nagasaki

    1 shared publication
  • Fumitake Uchida

    Department of Surgical Oncology, Nagasaki University Graduate School of Biomedical Sciences , Nagasaki

    1 shared publication

Latest Publications

  • Open Access

    Laparoscopic Distal Gastrectomy for Duodenal Adenocarcinoma Located in a Duodenal Bulb Diverticulum: Report of a Rare Case

    by Masato Nishimuta, Junichi Arai, Keiko Hamasaki, Yasumasa Hashimoto, Hayata Fukano, Tetsuro Tominaga, Takashi Nonaka, Keitaro Matsumoto

    INTRODUCTION: Duodenal adenocarcinomas are relatively rare. We report here a particularly rare case of duodenal adenocarcinoma that arose within a duodenal bulb diverticulum and was successfully managed surgically.CASE PRESENTATION: A 70-year-old woman presented to us with a history of duodenal bulb ulceration and a diverticulum in the same area diagnosed by esophagogastroduodenoscopy. Routine endoscopic examination revealed an elevated lesion growing from within the diverticulum to outside of it. Examination of a biopsy specimen resulted in a diagnosis of well-differentiated adenocarcinoma. Computed tomography failed to detect any lesions in the duodenal bulb. No enlarged lymph nodes or distant metastases were found. Fluoroscopic examination revealed a pool of contrast suggestive of a diverticulum in the duodenal bulb on the anal side of the pyloric ring. Thus, the clinical stage according to the TNM Classification based on the 8th edition of the Union for International Cancer Control/American Joint Committee on Cancer (UICC/AJCC 8th edition) was T1N0M0: Stage I. Endoscopic resection was not feasible because the tumor’s origin was within the diverticulum. Furthermore, surgical local resection was considered not to be feasible because of the tumor size and location. We performed laparoscopic distal gastrectomy, D1+ lymph node dissection, and Roux-en-Y reconstruction. The patient was discharged on the 10th postoperative day and is currently on outpatient follow-up with no evidence of recurrence 1 year postoperatively.CONCLUSIONS: We report here a rare case of an adenocarcinoma arising within a duodenal bulb diverticulum. We successfully performed a laparoscopic distal gastrectomy, this procedure being considered the optimal surgical approach for this patient.


  • Fabrication of a three-dimensional scaffold-free trachea with horseshoe-shaped hyaline cartilage

    by Fumitake Uchida, Keitaro Matsumoto, Masato Nishimuta, Takamune Matsumoto, Kaido Oishi, Ryosuke Hara, Ryusuke Machino, Daisuke Taniguchi, Shosaburo Oyama, Masaaki Moriyama, et al.

    OBJECTIVES: Tracheal regeneration is challenging owing to its unique anatomy and low blood supply. Most tracheal regeneration applications require scaffolds. Herein, we developed bio-three-dimensional-printed scaffold-free artificial tracheas. METHODS: We fabricated bio-three-dimensional-printed artificial tracheas. Their anterior surface comprised hyaline cartilage differentiated from mesenchymal stem cells, and their posterior surface comprised smooth muscle. Human bone marrow-derived mesenchymal stem cells were cultured and differentiated into chondrocytes using fibroblast growth factor-2 and transforming growth factor-beta-3. Initially, horseshoe-shaped spheroids were printed to cover the anterior surface of the artificial trachea, followed by the application of human bronchial smooth muscle cells for the posterior surface. After a 3-week maturing process, the artificial trachea was subjected to histological and immunohistochemical analyses. RESULTS: The anterior surface of the artificial trachea comprised well-differentiated hyaline cartilage from human bone marrow-derived mesenchymal stem cells. Immunohistochemistry revealed that the smooth muscle expressed α-smooth muscle actin and smooth muscle myosin heavy chain 11. CONCLUSIONS: A bio-three-dimensional-printed scaffold-free artificial trachea comprising different tissues at the front and back was successfully fabricated.


  • Open Access

    Safe laparoscopic resection of a giant schwannoma in the retroperitoneum using a fluorescent ureteral stent: a case report

    by Masato Nishimuta, Yorihisa Sumida, Masato Araki, Kouki Wakata, Kiyoaki Hamada, Tota Kugiyama, Ayako Shibuya, Shintaro Hashimoto, Keisuke Ozeki, Shigeyuki Morino, et al.

    Schwannomas that occur in the retroperitoneal cavity are rare. We herein report a patient who underwent safe laparoscopic resection by using a preoperative 3D computed tomography (CT) image and a fluorescent ureteral stent during the surgery. A 47-year-old man presented with left lower abdominal pain. CT showed a 10-cm continuous retroperitoneal tumor originating at the third lumbar nerve in the lower left abdomen. Schwannoma was suspected. We underwent laparoscopic resection of the tumor guided by 3D images obtained preoperatively. A fluorescent ureteral stent was implanted during the surgery to improve visibility and protect the left ureter. The resection was completed without injury of other organs and vessels. The patient was discharged on postoperative Day 5. By performing a preoperative simulation using 3D CT images, we could anticipate the anatomical findings and easily identify them intraoperatively. In addition, the fluorescent ureteral stent provided visual support, thereby contributing to safe surgery.