Lana Z. Popović Maneski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lana Z. Popović Maneski has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Dejan B. Popovic
University of Belgrade
2 shared publications - Nebojsa Malesevic
Lund University
2 shared publications - Thierry Keller
Tecnalia Research and Innovation
2 shared publications - Andrej M. Savic
University of Belgrade
1 shared publication - Goran Bijelić
TECNALIA, Basque Research and Technology Alliance (BRTA), 20009 Donostia-San Sebastian, Spain
1 shared publication - Nikola Jorgovanović
Faculty of Technical Sciences, University of Novi Sad, 21000 Novi Sad, Serbia
1 shared publication
Latest Publications
- 20 March 2013
- Published by Wiley in Muscle & Nerve
- Vol. 48 (6) , 930-937
Surface‐distributed low‐frequency asynchronous stimulation delays fatigue of stimulated muscles
Introduction: One important reason why functional electrical stimulation (FES) has not gained widespread clinical use is the limitation imposed by rapid muscle fatigue due to non‐physiological activation of the stimulated muscles. We aimed to show that asynchronous low‐pulse‐rate (LPR) electrical stimulation applied by multipad surface electrodes greatly postpones the occurrence of muscle fatigue compared with conventional stimulation (high pulse rate, HPR). Methods: We compared the produced force vs. time of the forearm muscles responsible for finger flexion in 2 stimulation protocols, LPR (fL = 10 Hz) and HPR (fH = 40 Hz). Results: Surface‐distributed low‐frequency asynchronous stimulation (sDLFAS) doubles the time interval before the onset of fatigue (104 ± 80%) compared with conventional synchronous stimulation. Conclusions: Combining the performance of multipad electrodes (increased selectivity and facilitated positioning) with sDLFAS (decreased fatigue) can improve many FES applications in both the lower and upper extremities. Muscle Nerve 48: 930–937, 2013
- 20 March 2013
- Published by Wiley in Muscle & Nerve
- Vol. 48 (6) , 930-937
Surface‐distributed low‐frequency asynchronous stimulation delays fatigue of stimulated muscles
Introduction: One important reason why functional electrical stimulation (FES) has not gained widespread clinical use is the limitation imposed by rapid muscle fatigue due to non‐physiological activation of the stimulated muscles. We aimed to show that asynchronous low‐pulse‐rate (LPR) electrical stimulation applied by multipad surface electrodes greatly postpones the occurrence of muscle fatigue compared with conventional stimulation (high pulse rate, HPR). Methods: We compared the produced force vs. time of the forearm muscles responsible for finger flexion in 2 stimulation protocols, LPR (fL = 10 Hz) and HPR (fH = 40 Hz). Results: Surface‐distributed low‐frequency asynchronous stimulation (sDLFAS) doubles the time interval before the onset of fatigue (104 ± 80%) compared with conventional synchronous stimulation. Conclusions: Combining the performance of multipad electrodes (increased selectivity and facilitated positioning) with sDLFAS (decreased fatigue) can improve many FES applications in both the lower and upper extremities. Muscle Nerve 48: 930–937, 2013
- Open Access
- 1 January 2012
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 9 (1) , 66
A multi-pad electrode based functional electrical stimulation system for restoration of grasp
Functional electrical stimulation (FES) applied via transcutaneous electrodes is a common rehabilitation technique for assisting grasp in patients with central nervous system lesions. To improve the stimulation effectiveness of conventional FES, we introduce multi-pad electrodes and a new stimulation paradigm.
- 1 January 2012
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 9 (1) , 66
Open AccessA multi-pad electrode based functional electrical stimulation system for restoration of grasp
Functional electrical stimulation (FES) applied via transcutaneous electrodes is a common rehabilitation technique for assisting grasp in patients with central nervous system lesions. To improve the stimulation effectiveness of conventional FES, we introduce multi-pad electrodes and a new stimulation paradigm.