Vincent Rialle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Vincent Rialle has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Antoine Piau
CERPOP, INSERM, Université Toulouse 3, Toulouse, France
2 shared publications - Benoit Lepage
USMR Support Unit for Research Methodology, Department of Epidemiology, Toulouse University Hospital, Toulouse, France
2 shared publications - Eric Campo
LAAS-CNRS, Toulouse University, CNRS, INSA, UT2J, Toulouse, France
2 shared publications - Fati Nourhashemi
Geriatrics Department, Internal Medicine and Cardiogeriatry Unit, Toulouse University Hospital, 31059 Toulouse, France
2 shared publications - Laetitia Courbet
Autonomie, Gérontologie, E-santé, Imagerie et Société Grenoble Alps University Grenoble France
2 shared publications - Yoann Charlon
Laboratoire d'analyse et d'architecture des systèmes Centre national de la Recherche Scientifique Toulouse France
2 shared publications
Latest Publications
- Open Access
- 5 July 2021
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 9 (7) , e15641
A Smart Shoe Insole to Monitor Frail Older Adults’ Walking Speed: Results of Two Evaluation Phases Completed in a Living Lab and Through a 12-Week Pilot Study
Background: Recent World Health Organization reports propose wearable devices to collect information on activity and walking speed as innovative health indicators. However, mainstream consumer-grade tracking devices and smartphone apps are often inaccurate and require long-term acceptability assessment. Objective: Our aim is to assess the user acceptability of an instrumented shoe insole in frail older adults. This device monitors participants’ walking speed and differentiates active walking from shuffling after step length calibration. Methods: A multiphase evaluation has been designed: 9 older adults were evaluated in a living lab for a day, 3 older adults were evaluated at home for a month, and a prospective randomized trial included 35 older adults at home for 3 months. A qualitative research design using face-to-face and phone semistructured interviews was performed. Our hypothesis was that this shoe insole was acceptable in monitoring long-term outdoor and indoor walking. The primary outcome was participants' acceptability, measured by a qualitative questionnaire and average time of insole wearing per day. The secondary outcome described physical frailty evolution in both groups. Results: Living lab results confirmed the importance of a multiphase design study with participant involvement. Participants proposed insole modifications. Overall acceptability had mixed results: low scores for reliability (2.1 out of 6) and high scores for usability (4.3 out of 6) outcomes. The calibration phase raised no particular concern. During the field test, a majority of participants (mean age 79 years) were very (10/16) or quite satisfied (3/16) with the insole's comfort at the end of the follow-up. Participant insole acceptability evolved as follows: 63% (12/19) at 1 month, 50% (9/18) at 2 months, and 75% (12/16) at 3 months. A total of 9 participants in the intervention group discontinued the intervention because of technical issues. All participants equipped for more than a week reported wearing the insole every day at 1 month, 83% (15/18) at 2 months, and 94% (15/16) at 3 months for 5.8, 6.3, and 5.1 hours per day, respectively. Insole data confirmed that participants effectively wore the insole without significant decline during follow-up for an average of 13.5 days per 4 months and 5.6 hours per day. For secondary end points, the change in frailty parameters or quality of life did not differ for those randomly assigned to the intervention group compared to usual care. Conclusions: Our study reports acceptability data on an instrumented insole in indoor and outdoor walking with remote monitoring in frail older adults under real-life conditions. To date, there is limited data in this population set. This thin instrumentation, including a flexible battery, was a technical challenge and seems to provide an acceptable solution over time that is valued by participants. However, users still raised certain acceptability issues. Given the growing interest in wearable health care devices, these results will be useful for future developments. Trial Registration: ClinicalTrials.gov NCT02316600; https://clinicaltrials.gov/ct2/show/NCT02316600
- 5 July 2021
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 9 (7) , e15641
Open AccessA Smart Shoe Insole to Monitor Frail Older Adults’ Walking Speed: Results of Two Evaluation Phases Completed in a Living Lab and Through a 12-Week Pilot Study
Background: Recent World Health Organization reports propose wearable devices to collect information on activity and walking speed as innovative health indicators. However, mainstream consumer-grade tracking devices and smartphone apps are often inaccurate and require long-term acceptability assessment. Objective: Our aim is to assess the user acceptability of an instrumented shoe insole in frail older adults. This device monitors participants’ walking speed and differentiates active walking from shuffling after step length calibration. Methods: A multiphase evaluation has been designed: 9 older adults were evaluated in a living lab for a day, 3 older adults were evaluated at home for a month, and a prospective randomized trial included 35 older adults at home for 3 months. A qualitative research design using face-to-face and phone semistructured interviews was performed. Our hypothesis was that this shoe insole was acceptable in monitoring long-term outdoor and indoor walking. The primary outcome was participants' acceptability, measured by a qualitative questionnaire and average time of insole wearing per day. The secondary outcome described physical frailty evolution in both groups. Results: Living lab results confirmed the importance of a multiphase design study with participant involvement. Participants proposed insole modifications. Overall acceptability had mixed results: low scores for reliability (2.1 out of 6) and high scores for usability (4.3 out of 6) outcomes. The calibration phase raised no particular concern. During the field test, a majority of participants (mean age 79 years) were very (10/16) or quite satisfied (3/16) with the insole's comfort at the end of the follow-up. Participant insole acceptability evolved as follows: 63% (12/19) at 1 month, 50% (9/18) at 2 months, and 75% (12/16) at 3 months. A total of 9 participants in the intervention group discontinued the intervention because of technical issues. All participants equipped for more than a week reported wearing the insole every day at 1 month, 83% (15/18) at 2 months, and 94% (15/16) at 3 months for 5.8, 6.3, and 5.1 hours per day, respectively. Insole data confirmed that participants effectively wore the insole without significant decline during follow-up for an average of 13.5 days per 4 months and 5.6 hours per day. For secondary end points, the change in frailty parameters or quality of life did not differ for those randomly assigned to the intervention group compared to usual care. Conclusions: Our study reports acceptability data on an instrumented insole in indoor and outdoor walking with remote monitoring in frail older adults under real-life conditions. To date, there is limited data in this population set. This thin instrumentation, including a flexible battery, was a technical challenge and seems to provide an acceptable solution over time that is valued by participants. However, users still raised certain acceptability issues. Given the growing interest in wearable health care devices, these results will be useful for future developments. Trial Registration: ClinicalTrials.gov NCT02316600; https://clinicaltrials.gov/ct2/show/NCT02316600
- Open Access
- 25 July 2019
- Published by JMIR Publications Inc. in JMIR Preprints
A Smart Shoe Insole to Monitor Frail Older Adults’ Walking Speed: Results of Two Evaluation Phases Completed in a Living Lab and Through a 12-Week Pilot Study (Preprint)
BACKGROUND Recent World Health Organization reports propose wearable devices to collect information on activity and walking speed as innovative health indicators. However, mainstream consumer-grade tracking devices and smartphone apps are often inaccurate and require long-term acceptability assessment. OBJECTIVE Our aim is to assess the user acceptability of an instrumented shoe insole in frail older adults. This device monitors participants’ walking speed and differentiates active walking from shuffling after step length calibration. METHODS A multiphase evaluation has been designed: 9 older adults were evaluated in a living lab for a day, 3 older adults were evaluated at home for a month, and a prospective randomized trial included 35 older adults at home for 3 months. A qualitative research design using face-to-face and phone semistructured interviews was performed. Our hypothesis was that this shoe insole was acceptable in monitoring long-term outdoor and indoor walking. The primary outcome was participants' acceptability, measured by a qualitative questionnaire and average time of insole wearing per day. The secondary outcome described physical frailty evolution in both groups. RESULTS Living lab results confirmed the importance of a multiphase design study with participant involvement. Participants proposed insole modifications. Overall acceptability had mixed results: low scores for reliability (2.1 out of 6) and high scores for usability (4.3 out of 6) outcomes. The calibration phase raised no particular concern. During the field test, a majority of participants (mean age 79 years) were very (10/16) or quite satisfied (3/16) with the insole's comfort at the end of the follow-up. Participant insole acceptability evolved as follows: 63% (12/19) at 1 month, 50% (9/18) at 2 months, and 75% (12/16) at 3 months. A total of 9 participants in the intervention group discontinued the intervention because of technical issues. All participants equipped for more than a week reported wearing the insole every day at 1 month, 83% (15/18) at 2 months, and 94% (15/16) at 3 months for 5.8, 6.3, and 5.1 hours per day, respectively. Insole data confirmed that participants effectively wore the insole without significant decline during follow-up for an average of 13.5 days per 4 months and 5.6 hours per day. For secondary end points, the change in frailty parameters or quality of life did not differ for those randomly assigned to the intervention group compared to usual care. CONCLUSIONS Our study reports acceptability data on an instrumented insole in indoor and outdoor walking with remote monitoring in frail older adults under real-life conditions. To date, there is limited data in this population set. This thin instrumentation, including a flexible battery, was a technical challenge and seems to provide an acceptable solution over time that is valued by participants. However, users still raised certain acceptability issues. Given the growing interest in wearable health care devices, these results will be useful for future developments. CLINICALTRIAL ClinicalTrials.gov NCT02316600; https://clinicaltrials.gov/ct2/show/NCT02316600
- 25 July 2019
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessA Smart Shoe Insole to Monitor Frail Older Adults’ Walking Speed: Results of Two Evaluation Phases Completed in a Living Lab and Through a 12-Week Pilot Study (Preprint)
BACKGROUND Recent World Health Organization reports propose wearable devices to collect information on activity and walking speed as innovative health indicators. However, mainstream consumer-grade tracking devices and smartphone apps are often inaccurate and require long-term acceptability assessment. OBJECTIVE Our aim is to assess the user acceptability of an instrumented shoe insole in frail older adults. This device monitors participants’ walking speed and differentiates active walking from shuffling after step length calibration. METHODS A multiphase evaluation has been designed: 9 older adults were evaluated in a living lab for a day, 3 older adults were evaluated at home for a month, and a prospective randomized trial included 35 older adults at home for 3 months. A qualitative research design using face-to-face and phone semistructured interviews was performed. Our hypothesis was that this shoe insole was acceptable in monitoring long-term outdoor and indoor walking. The primary outcome was participants' acceptability, measured by a qualitative questionnaire and average time of insole wearing per day. The secondary outcome described physical frailty evolution in both groups. RESULTS Living lab results confirmed the importance of a multiphase design study with participant involvement. Participants proposed insole modifications. Overall acceptability had mixed results: low scores for reliability (2.1 out of 6) and high scores for usability (4.3 out of 6) outcomes. The calibration phase raised no particular concern. During the field test, a majority of participants (mean age 79 years) were very (10/16) or quite satisfied (3/16) with the insole's comfort at the end of the follow-up. Participant insole acceptability evolved as follows: 63% (12/19) at 1 month, 50% (9/18) at 2 months, and 75% (12/16) at 3 months. A total of 9 participants in the intervention group discontinued the intervention because of technical issues. All participants equipped for more than a week reported wearing the insole every day at 1 month, 83% (15/18) at 2 months, and 94% (15/16) at 3 months for 5.8, 6.3, and 5.1 hours per day, respectively. Insole data confirmed that participants effectively wore the insole without significant decline during follow-up for an average of 13.5 days per 4 months and 5.6 hours per day. For secondary end points, the change in frailty parameters or quality of life did not differ for those randomly assigned to the intervention group compared to usual care. CONCLUSIONS Our study reports acceptability data on an instrumented insole in indoor and outdoor walking with remote monitoring in frail older adults under real-life conditions. To date, there is limited data in this population set. This thin instrumentation, including a flexible battery, was a technical challenge and seems to provide an acceptable solution over time that is valued by participants. However, users still raised certain acceptability issues. Given the growing interest in wearable health care devices, these results will be useful for future developments. CLINICALTRIAL ClinicalTrials.gov NCT02316600; https://clinicaltrials.gov/ct2/show/NCT02316600
- 26 June 2017
- Published by Taylor & Francis
- p. 178-194
Preliminary Evaluation of a Digital Diary for Elder People in Nursing Homes
- 26 June 2017
- Published by Taylor & Francis
- p. 178-194
Preliminary Evaluation of a Digital Diary for Elder People in Nursing Homes
- 1 January 2014
- Published by Eska Editions in Journal international de bioéthique et d'éthique des sciences
- Vol. 25 (3) , 127-145
Chapitre 8. Télémédecine et gérontechnologie pour la maladie d'Alzheimer : nécessité d'un pilotage international par l'éthique
La télémédecine et la gérontechnologie se développent sur un mode que l’on peut qualifier d’« immobilisme hyperactif », soit une multiplication anarchique d’expérimentations et d’outils soldée par une incapacité à mettre en place des produits utiles, souhaitées et pérennes. L’objectif de cet article est de montrer, à partir de travaux scientifiques nationaux et internationaux, la nécessité d’ancrer la mise en place des expérimentations de nouvelles pratiques et de nouvelles organisations sur la notion d’éthique si l’on souhaite véritablement sortir de cet immobilisme hyperactif. En effet, le contexte actuel international de vieillissement des populations et de crise socio-économique rend urgent le développement de produits fiables et accessibles d’aide aux personnes vulnérables, en particulier celles qui sont atteintes de la maladie d’Alzheimer ou d’une maladie apparentée. Mais ce contexte exerce dans le même temps une pression pour un développement d’outils davantage rentables à très courts termes et rapidement obsolescents qu’adaptés aux vrais besoins. Il en résulte, dans l’opinion publique, la sphère politique et le monde scientifique et des craintes pouvant jouer un rôle protecteur face aux dérives possibles de la techno-science, mais pouvant aussi aller à l’encontre du droit de chaque citoyen de bénéficier des avancées de la science et de ses retombées technologiques. Il relève justement de la mission de l’éthique de définir et de mettre en application les principes permettant de résoudre ce dilemme. L’éthique cependant ne saurait être limitée à un rôle normatif ou consultatif. Elle devrait aussi présider aux décisions et être le moteur d’un usage raisonné et maîtrisé des technologies, afin que soit respecté l’objectif principal de cet usage : venir en aide à des personnes en souffrance.
- 1 January 2014
- Published by Eska Editions in Journal international de bioéthique et d'éthique des sciences
- Vol. 25 (3) , 127-145
Chapitre 8. Télémédecine et gérontechnologie pour la maladie d'Alzheimer : nécessité d'un pilotage international par l'éthique
La télémédecine et la gérontechnologie se développent sur un mode que l’on peut qualifier d’« immobilisme hyperactif », soit une multiplication anarchique d’expérimentations et d’outils soldée par une incapacité à mettre en place des produits utiles, souhaitées et pérennes. L’objectif de cet article est de montrer, à partir de travaux scientifiques nationaux et internationaux, la nécessité d’ancrer la mise en place des expérimentations de nouvelles pratiques et de nouvelles organisations sur la notion d’éthique si l’on souhaite véritablement sortir de cet immobilisme hyperactif. En effet, le contexte actuel international de vieillissement des populations et de crise socio-économique rend urgent le développement de produits fiables et accessibles d’aide aux personnes vulnérables, en particulier celles qui sont atteintes de la maladie d’Alzheimer ou d’une maladie apparentée. Mais ce contexte exerce dans le même temps une pression pour un développement d’outils davantage rentables à très courts termes et rapidement obsolescents qu’adaptés aux vrais besoins. Il en résulte, dans l’opinion publique, la sphère politique et le monde scientifique et des craintes pouvant jouer un rôle protecteur face aux dérives possibles de la techno-science, mais pouvant aussi aller à l’encontre du droit de chaque citoyen de bénéficier des avancées de la science et de ses retombées technologiques. Il relève justement de la mission de l’éthique de définir et de mettre en application les principes permettant de résoudre ce dilemme. L’éthique cependant ne saurait être limitée à un rôle normatif ou consultatif. Elle devrait aussi présider aux décisions et être le moteur d’un usage raisonné et maîtrisé des technologies, afin que soit respecté l’objectif principal de cet usage : venir en aide à des personnes en souffrance.
- 24 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1280-1281
Computers And Artificial Intelligence In Psychiatry Brief History And State Of The Art
- 24 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1280-1281
Computers And Artificial Intelligence In Psychiatry Brief History And State Of The Art
- 1 November 1999
- Published by SAGE Publications in Technology and Health Care
- Vol. 7 (5) , 343-357
A smart room for hospitalised elderly people: essay of modelling and first steps of an experiment
We present a study of modelling and the first steps of an experiment of a smart room for hospitalised elderly people. The system aims at detecting falls and sicknesses, and implements four main functions: perception of patient and environment through
- 1 November 1999
- Published by SAGE Publications in Technology and Health Care
- Vol. 7 (5) , 343-357
A smart room for hospitalised elderly people: essay of modelling and first steps of an experiment
We present a study of modelling and the first steps of an experiment of a smart room for hospitalised elderly people. The system aims at detecting falls and sicknesses, and implements four main functions: perception of patient and environment through