Siegfried Arndt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Siegfried Arndt has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- A. Guglielmelli1 shared publication
A. Pašiškevičius
1 shared publication- Aleksandras Sevcik
Department of Physics, Kaunas University of Technology, Studentų 50, 51368 Kaunas, Lithuania
1 shared publication - Astrid Kloosterman
Centre for Infectious Disease Control, National Institute for Public Health and the Environment (RIVM)
1 shared publication C. Potiriadis
1 shared publicationG. Fritsch
1 shared publication
Latest Publications
- Open Access
- 7 July 2025
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 442
Benchmarking exercise on the radiological consequence calculation due to a potential severe accident in Zaporizhzhia Nuclear Power Plant
- 7 July 2025
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 442
Open AccessBenchmarking exercise on the radiological consequence calculation due to a potential severe accident in Zaporizhzhia Nuclear Power Plant
- Open Access
- 17 November 2011
- Published by Wiley in Science and Technology of Nuclear Installations
- Vol. 2012, 1-20
Experimental Studies for the VVER-440/213 Bubble Condenser System for Kola NPP at the Integral Test Facility BC V-213
In the frame of Tacis Project R2.01/99, which was running from 2003 to 2005, the bubble condenser system of Kola NPP (unit 3) was qualified at the integral test facility BC V-213. Three LB LOCA tests, two MSLB tests, and one SB LOCA test were performed. The appropriate test scenarios for BC V-213 test facility, modeling accidents in the Kola NPP unit 3, were determined with pretest calculations. Analysis of test results has shown that calculated initial conditions and test scenarios were properly reproduced in the tests. The detailed posttest analysis of the tests performed at BC V-213 test facility was aimed to validate the COCOSYS code for the calculation of thermohydraulic processes in the hermetic compartments and bubble condenser. After that the validated COCOSYS code was applied to NPP calculations for Kola NPP (unit 3). Results of Tacis R2.01/99 Project confirmed the bubble condenser functionality during large and small break LOCAs and MSLB accidents. Maximum loads were reached in the LB LOCA case. No condensation oscillations were observed.
- 17 November 2011
- Published by Wiley in Science and Technology of Nuclear Installations
- Vol. 2012, 1-20
Open AccessExperimental Studies for the VVER-440/213 Bubble Condenser System for Kola NPP at the Integral Test Facility BC V-213
In the frame of Tacis Project R2.01/99, which was running from 2003 to 2005, the bubble condenser system of Kola NPP (unit 3) was qualified at the integral test facility BC V-213. Three LB LOCA tests, two MSLB tests, and one SB LOCA test were performed. The appropriate test scenarios for BC V-213 test facility, modeling accidents in the Kola NPP unit 3, were determined with pretest calculations. Analysis of test results has shown that calculated initial conditions and test scenarios were properly reproduced in the tests. The detailed posttest analysis of the tests performed at BC V-213 test facility was aimed to validate the COCOSYS code for the calculation of thermohydraulic processes in the hermetic compartments and bubble condenser. After that the validated COCOSYS code was applied to NPP calculations for Kola NPP (unit 3). Results of Tacis R2.01/99 Project confirmed the bubble condenser functionality during large and small break LOCAs and MSLB accidents. Maximum loads were reached in the LB LOCA case. No condensation oscillations were observed.