Ji Youn Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ji Youn Lee has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
Minjeong Kwak
Nanobio Measurement Group, Division of Biomedical Metrology, Korea Research Institute of Standards and Science, 267 Gajeong-ro, Yuseong-gu, Daejeon 34113, Republic of Korea
4 shared publicationsHye Ji Shin
Biometrology Group, Division of Biomedical Metrology, Korea Research Institute of Standards and Science, 267 Gajeong-ro, Yuseong-gu, Daejeon 34113, Republic of Korea
3 shared publicationsGippeum J. Lim
Department of Biological Sciences, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea
2 shared publications- Hye Ji Shin
Biometrology Group, Division of Biomedical Metrology, Korea Research Institute of Standards and Science, 267 Gajeong-ro, Yuseong-gu, Daejeon 34113, Republic of Korea
2 shared publications HyeRim Shin
Biometrology Group, Division of Chemical and Biological Metrology, Korea Research Institute of Standards and Science, 267 Gajeong-ro, Yuseong-gu, Daejeon, 34113, Republic of Korea
2 shared publicationsInchul Yang
Biometrology Group, Division of Biomedical Metrology, Korea Research Institute of Standards and Science, Daejeon, Republic of Korea
2 shared publications
Latest Publications
- Open Access
- 5 August 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Round robin test on polystyrene bead number concentration measurement using flow cytometry and commercial automated particle counters
Reliable particle counting is critical for applications such as clinical monitoring and cell therapy manufacturing. However, various particle counters using different measurement principles are employed, and the absence of reference materials makes standardization challenging. We conducted a round robin test to evaluate the accuracy and reproducibility of particle number concentration measurements using monodisperse polystyrene beads. The study material was prepared, characterized for homogeneity and stability, and assigned a reference value using the volumetric sample loop method. Internal comparisons showed that methods relying on counting beads and automated counters reported concentrations 9–10% higher than the reference value. The material was distributed to three instrument manufacturers, each employing automated counters. The reported results deviated from the reference value by approximately 10%. Feedback from participants highlighted calibration practices and flow cell artifacts as potential sources of bias. Expanded uncertainties, considering repeatability and method-specific factors, ranged from 8% to 11%, with all results falling within the expanded uncertainty of the reference value. This study demonstrates the importance of uncertainty estimation in interlaboratory studies and highlights the need for harmonized results in particle counting. The findings provide a basis for future standardization efforts in particle and cell counting methods.
- 5 August 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessRound robin test on polystyrene bead number concentration measurement using flow cytometry and commercial automated particle counters
Reliable particle counting is critical for applications such as clinical monitoring and cell therapy manufacturing. However, various particle counters using different measurement principles are employed, and the absence of reference materials makes standardization challenging. We conducted a round robin test to evaluate the accuracy and reproducibility of particle number concentration measurements using monodisperse polystyrene beads. The study material was prepared, characterized for homogeneity and stability, and assigned a reference value using the volumetric sample loop method. Internal comparisons showed that methods relying on counting beads and automated counters reported concentrations 9–10% higher than the reference value. The material was distributed to three instrument manufacturers, each employing automated counters. The reported results deviated from the reference value by approximately 10%. Feedback from participants highlighted calibration practices and flow cell artifacts as potential sources of bias. Expanded uncertainties, considering repeatability and method-specific factors, ranged from 8% to 11%, with all results falling within the expanded uncertainty of the reference value. This study demonstrates the importance of uncertainty estimation in interlaboratory studies and highlights the need for harmonized results in particle counting. The findings provide a basis for future standardization efforts in particle and cell counting methods.
- Open Access
- 19 November 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (47) , 25999-26008
Comparative Analysis of Sample Loop and Counting Bead–Based Methods for Size-Dependent Bias in Flow Cytometry
Reliable and accurate particle number concentration measurements are essential across various fields, including clinical diagnostics, environmental monitoring, and industrial applications. Flow cytometry is widely used for these measurements, where the use of counting beads is a common approach. However, this method can introduce size-dependent bias when the target particles differ in size from the counting beads. To evaluate size-dependent bias, this study systematically compares the conventional counting bead-based method with a sample loop-based method that relies on total counting with a defined sample volume. Experimental results show that while both methods yield similar concentrations for beads of comparable size, discrepancies arise when there are significant size differences between the counting beads and target particles. To investigate the cause of this bias, simulations based on force balance analysis were conducted, revealing that larger beads experience stronger forces that facilitate their movement toward the detection area, while smaller beads are more influenced by Brownian motion, which impedes their overall motion. These findings provide a mechanistic explanation for the observed size-dependent bias, confirming that differences in hydrodynamic behavior contribute to variations in bead distribution and motion. By using the sample loop method, which minimizes size-dependent bias, and employing an empirical equation derived from the results, this study offers a reliable approach for predicting and mitigating bias in particle concentration measurements. This work therefore contributes to the development of more precise and traceable methods for particle number concentration measurement, with implications for a wide range of biological and industrial applications.
- 19 November 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (47) , 25999-26008
Open AccessComparative Analysis of Sample Loop and Counting Bead–Based Methods for Size-Dependent Bias in Flow Cytometry
Reliable and accurate particle number concentration measurements are essential across various fields, including clinical diagnostics, environmental monitoring, and industrial applications. Flow cytometry is widely used for these measurements, where the use of counting beads is a common approach. However, this method can introduce size-dependent bias when the target particles differ in size from the counting beads. To evaluate size-dependent bias, this study systematically compares the conventional counting bead-based method with a sample loop-based method that relies on total counting with a defined sample volume. Experimental results show that while both methods yield similar concentrations for beads of comparable size, discrepancies arise when there are significant size differences between the counting beads and target particles. To investigate the cause of this bias, simulations based on force balance analysis were conducted, revealing that larger beads experience stronger forces that facilitate their movement toward the detection area, while smaller beads are more influenced by Brownian motion, which impedes their overall motion. These findings provide a mechanistic explanation for the observed size-dependent bias, confirming that differences in hydrodynamic behavior contribute to variations in bead distribution and motion. By using the sample loop method, which minimizes size-dependent bias, and employing an empirical equation derived from the results, this study offers a reliable approach for predicting and mitigating bias in particle concentration measurements. This work therefore contributes to the development of more precise and traceable methods for particle number concentration measurement, with implications for a wide range of biological and industrial applications.
- Open Access
- 16 April 2025
- Published by Royal Society of Chemistry (RSC) in Nanoscale Advances
- Vol. 7 (11) , 3558-3567
Quantification of cellular uptake of gold nanoparticles via scattering intensity changes in flow cytometry
Quantifying cellular uptake of nanoparticles is critical for understanding their biological interactions and optimizing their applications in nanomedicine.
- 16 April 2025
- Published by Royal Society of Chemistry (RSC) in Nanoscale Advances
- Vol. 7 (11) , 3558-3567
Open AccessQuantification of cellular uptake of gold nanoparticles via scattering intensity changes in flow cytometry
Quantifying cellular uptake of nanoparticles is critical for understanding their biological interactions and optimizing their applications in nanomedicine.
- Open Access
- 24 January 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (02) , 023516-14
Hyperspectral analysis to assess gametocytogenesis stage progression in malaria-infected human erythrocytes
Malaria is a life-threatening infectious disease caused by parasites spread by bites from infected Anopheles mosquitoes. Global warming speeds up the growth of parasites in the mosquito, resulting in not only accelerated transmission in tropical regions but also the reemergence of cases in regions that were formerly malaria-free.1 The slowdown of malaria control efficiency, the large number (more than 600,000) of annual deaths, and an increase in drug-resistant parasites2 demand more compliant drug development strategies, which are pivotal in combating this deadly disease at every stage of the infection. The development of antimalarial drugs has primarily focused on asexual blood-stage parasites as parasites in this stage directly cause symptoms in patients. For a more comprehensive antimalarial strategy, drug developers have recently paid more attention to stage-dependent malaria studies focused on the maturation process of gametocytes, or gametocytogenesis,3 – 5 which has opened other drug design paradigms toward the development of anti-gametocyte drugs. The biology of gametocytes differs from that of asexual-stage parasites in many ways, manifested by progressive changes in biochemical, morphological, and mechanical properties during gametocytogenesis.
- 24 January 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (02) , 023516-14
Open AccessHyperspectral analysis to assess gametocytogenesis stage progression in malaria-infected human erythrocytes
Malaria is a life-threatening infectious disease caused by parasites spread by bites from infected Anopheles mosquitoes. Global warming speeds up the growth of parasites in the mosquito, resulting in not only accelerated transmission in tropical regions but also the reemergence of cases in regions that were formerly malaria-free.1 The slowdown of malaria control efficiency, the large number (more than 600,000) of annual deaths, and an increase in drug-resistant parasites2 demand more compliant drug development strategies, which are pivotal in combating this deadly disease at every stage of the infection. The development of antimalarial drugs has primarily focused on asexual blood-stage parasites as parasites in this stage directly cause symptoms in patients. For a more comprehensive antimalarial strategy, drug developers have recently paid more attention to stage-dependent malaria studies focused on the maturation process of gametocytes, or gametocytogenesis,3 – 5 which has opened other drug design paradigms toward the development of anti-gametocyte drugs. The biology of gametocytes differs from that of asexual-stage parasites in many ways, manifested by progressive changes in biochemical, morphological, and mechanical properties during gametocytogenesis.
- Open Access
- 7 August 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1323, 343064
Development of a media cell-free DNA direct digital PCR method for cell viability estimation
- 7 August 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1323, 343064
Open AccessDevelopment of a media cell-free DNA direct digital PCR method for cell viability estimation
- Open Access
- 27 June 2024
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 416 (20) , 4481-4490
Use of a sample injection loop for an accurate measurement of particle number concentration by flow cytometry
Flow cytometry plays a pivotal role in biotechnology by providing quantitative measurements for a wide range of applications. Nonetheless, achieving precise particle quantification, particularly without relying on counting beads, remains a challenge. In this study, we introduce a novel exhaustive counting method featuring a sample loop–based injection system that delivers a defined sample volume to a detection system to enhance quantification in flow cytometry. We systematically assess the performance characteristics of this system with micron-sized polystyrene beads, addressing issues related to sample introduction, adsorption, and volume measurement. Results underscore the excellent analytical performance of the proposed method, characterized by high linearity and repeatability. We compare our approach to counting bead–based measurements, and while an approximate bias value was observed, the measured values were found to be similar between the methods, demonstrating its comparability and reliability. This method holds great promise for improving the accuracy and precision of particle quantification in flow cytometry, with implications for various fields including healthcare and environmental monitoring.
- 27 June 2024
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 416 (20) , 4481-4490
Open AccessUse of a sample injection loop for an accurate measurement of particle number concentration by flow cytometry
Flow cytometry plays a pivotal role in biotechnology by providing quantitative measurements for a wide range of applications. Nonetheless, achieving precise particle quantification, particularly without relying on counting beads, remains a challenge. In this study, we introduce a novel exhaustive counting method featuring a sample loop–based injection system that delivers a defined sample volume to a detection system to enhance quantification in flow cytometry. We systematically assess the performance characteristics of this system with micron-sized polystyrene beads, addressing issues related to sample introduction, adsorption, and volume measurement. Results underscore the excellent analytical performance of the proposed method, characterized by high linearity and repeatability. We compare our approach to counting bead–based measurements, and while an approximate bias value was observed, the measured values were found to be similar between the methods, demonstrating its comparability and reliability. This method holds great promise for improving the accuracy and precision of particle quantification in flow cytometry, with implications for various fields including healthcare and environmental monitoring.
- Open Access
- 27 February 2023
- Published by Springer Nature in EJNMMI Research
- Vol. 13 (1) , 1-9
Correction: [18F]ROStrace detects oxidative stress in vivo and predicts progression of Alzheimer’s disease pathology in APP/PS1 mice
- 27 February 2023
- Published by Springer Nature in EJNMMI Research
- Vol. 13 (1) , 1-9
Open AccessCorrection: [18F]ROStrace detects oxidative stress in vivo and predicts progression of Alzheimer’s disease pathology in APP/PS1 mice
- Open Access
- 23 November 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-9
Quantifying fluorescent nanoparticle uptake in mammalian cells using a plate reader
In keeping with the rapid expansion of nanoparticle applications, various tools are required to investigate how nanoparticles interact with biological entities. Many assays have been developed to measure the cellular uptake of nanoparticles, but so far most of the methods are laborious and often non-quantitative. Here we developed an easily accessible and robust quantitative measurement method of the level of cellular uptake of fluorescently labeled nanoparticles using a plate reader. In the experimental design, potential issues that could lead to measurement variation were identified and addressed. For example, the variation in fluorescence intensity of samples due to differences in cell number was normalized to optical density, which is a physical value corresponding to the cell number. Number of washings and sample handling temperature were optimized to minimize the interference by residual nanoparticles and possible efflux of nanoparticles from cells, respectively. The developed assay was demonstrated with the lymphocyte cell line Jurkat to measure the cellular uptake of fluorescently labeled 50 nm polystyrene beads, and its applicability was further confirmed with the lung carcinoma cell line A549 and another lymphocyte cell line RPMI8226.
- 23 November 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-9
Open AccessQuantifying fluorescent nanoparticle uptake in mammalian cells using a plate reader
In keeping with the rapid expansion of nanoparticle applications, various tools are required to investigate how nanoparticles interact with biological entities. Many assays have been developed to measure the cellular uptake of nanoparticles, but so far most of the methods are laborious and often non-quantitative. Here we developed an easily accessible and robust quantitative measurement method of the level of cellular uptake of fluorescently labeled nanoparticles using a plate reader. In the experimental design, potential issues that could lead to measurement variation were identified and addressed. For example, the variation in fluorescence intensity of samples due to differences in cell number was normalized to optical density, which is a physical value corresponding to the cell number. Number of washings and sample handling temperature were optimized to minimize the interference by residual nanoparticles and possible efflux of nanoparticles from cells, respectively. The developed assay was demonstrated with the lymphocyte cell line Jurkat to measure the cellular uptake of fluorescently labeled 50 nm polystyrene beads, and its applicability was further confirmed with the lung carcinoma cell line A549 and another lymphocyte cell line RPMI8226.
- Open Access
- 20 September 2021
- Published by Elsevier in Biochemistry and Biophysics Reports
- Vol. 28, 101137
Probing TGF-β1-induced cytoskeletal rearrangement by fluorescent-labeled silica nanoparticle uptake assay
- 20 September 2021
- Published by Elsevier in Biochemistry and Biophysics Reports
- Vol. 28, 101137
Open AccessProbing TGF-β1-induced cytoskeletal rearrangement by fluorescent-labeled silica nanoparticle uptake assay
- Open Access
- 2 July 2020
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 12 (29) , 15743-15751
Quantifying the level of nanoparticle uptake in mammalian cells using flow cytometry
Reliable quantification of nanoparticle uptake in mammalian cells is essential to study the effects of nanoparticles in the fields of medicine and environmental science.
- 2 July 2020
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 12 (29) , 15743-15751
Open AccessQuantifying the level of nanoparticle uptake in mammalian cells using flow cytometry
Reliable quantification of nanoparticle uptake in mammalian cells is essential to study the effects of nanoparticles in the fields of medicine and environmental science.