Paolo Montemaggi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Paolo Montemaggi has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Eddie Y. Lo
Department of Orthopedic Surgery, Baylor University Medical Center, Baylor Scott & White Health, Dallas, Texas
2 shared publications - Sumant G. Krishnan
Department of Orthopedic Surgery, Baylor University Medical Center, Baylor Scott & White Health, Dallas, Texas
2 shared publications - Ali Ehsani
Department of Industrial Management, Arak University, Arak, Iran
1 shared publication - Alvin Ouseph
The Shoulder Center, Baylor Scott & White Research Institute, Dallas, Texas
1 shared publication - Andrea Merlo
LAM - Motion Analysis Laboratory, Neuromotor and Rehabilitation Department, San Sebastiano Hospital, Azienda USL-IRCCS di Reggio Emilia, Italy
1 shared publication C. Rambelli
Gait&Motion Analysis Laboratory, Sol et Salus Hospital, Torre Pedrera di Rimini (RN), Italy
1 shared publication
Latest Publications
- 1 October 2024
- Published by Wolters Kluwer Health in JBJS Essential Surgical Techniques
- Vol. 14 (4)
Cementless Reverse Shoulder Arthroplasty Technique to Maximize Press-Fit Fixation with Humeral Matchstick Bone Grafts
Background: Cementless reverse shoulder arthroplasty has become increasingly popular because of the improved implant design, porous ingrowth surface, and surgical techniques. When avoiding the risks of cement use, a press-fit arthroplasty stem that has been implanted may not feel immediately stable, especially if the medullary canal size is in between standard stem diameters. To help surgeons improve fixation and avoid overstuffing the medullary canal, we present the matchstick autograft augmentation technique. The use of humeral autograft, analogous to impaction grafting in hip arthroplasty, has been reported to have promising short-term outcomes 2,3 . This technique of using humeral autograft material, dubbed matchstick autografts because of their shape and size, allows for optimization of humeral stem stability with the option of smaller cementless humeral implants. By avoiding overstuffing of the medullary canal, this technique aims to reduce the incidences of intraoperative fracture, postoperative stress shielding, and potential implant loosening 4–6 . Description: Cementless reverse total shoulder arthroplasty is routinely performed via the anterosuperior approach 7 ; however, a deltopectoral approach can be utilized if desired. The canal is sequentially broached with implant trials until the tactile feedback demonstrates axial and rotational stability. In cases in which tactile feedback during implantation demonstrates slight movement, the smaller implant size can be selected and augmented with matchstick autograft. An oscillating saw is utilized to cut the edges of the previously resected humeral head in order to expose the subchondral bone surface. Graft sticks about 20 mm in length and 1 to 3 mm in width are then fashioned. Humeral trials are then implanted with the matchstick grafts placed lengthwise alongside the humeral stem. Axial and rotational press-fit is again assessed. If adequate, the formal humeral implant is selected and implanted in position. As in conventional impaction grafting, the grafts are compressed to the side of the humeral canal, but they offer more corticocancellous structure than bone chips. This technique is applicable even in some fracture scenarios. Alternatives: When a specific press-fit humeral stem size does not achieve adequate stability, there are typically 3 surgical alternatives. First, a larger stem size can be selected. Second, the implant can be inserted deeper to achieve press-fit stability. Third, cement can be added to fill the medullary canal and create immediate stability. Rationale: When implanting the humeral prosthesis, the operating surgeon’s primary goal is stem stability. When faced with lack of stability, the surgeon can select a larger humeral stem, risking stress shielding; implant the stem deeper, compromising length and risking humeral fracture; or consider a cemented implant. In order to minimize the risk of intraoperative cardiopulmonary events and complicated subsequent revision surgeries 8 , the use of cement should be avoided if at all possible. Shoulder surgeons have reported grafting techniques, analogous to hip impaction grafting, that have yielded good success 3 . The technique that we describe utilizes a matchstick structural autograft that helps improve cementless fixation in primary humeral implantation cases and allows for the use of a smaller stem. The structural shape of the graft allows this technique to be utilized even in selected proximal humeral fractures. Expected Outcomes: Other studies have reported on the use of softer cancellous autografts to stabilize humeral implants in shoulder arthroplasty. In a study of 286 arthroplasties with a minimum follow-up of 2 years, Lucas et al. reported that 267 humeral stems (93.3%) had not subsided 3 . Humphrey and Bravman used cancellous autograft to achieve metaphyseal centering of the humeral component in 53 patients, with no cases of humeral implant loosening at 12 months 2 . Lo et al. reported 91% tuberosity healing in their series of cementless reverse total shoulder arthroplasties augmented with matchstick autografts 1 , with no cases of aseptic humeral stem loosening. Montemaggi et al. used matchstick autografts to augment 46 primary cementless reverse total shoulder arthroplasties and found zero instances of humeral loosening at 1-year follow-up 9 . Important Tips: The strongest humeral matchstick grafts come from the subchondral surface. After creating the graft, it is palpated for structural integrity. A stiffer or softer graft can be chosen, depending on surgeon preference. Surgeons can try impacting the graft with humeral trials to assess the stem stability prior to final implantation. Acronyms and Abbreviations: RTSA = reverse total shoulder arthroplasty FX = fracture 3D CT = 3-dimensional computed tomography XR = x-ray FU = follow-up
- 1 October 2024
- Published by Wolters Kluwer Health in JBJS Essential Surgical Techniques
- Vol. 14 (4)
Cementless Reverse Shoulder Arthroplasty Technique to Maximize Press-Fit Fixation with Humeral Matchstick Bone Grafts
Background: Cementless reverse shoulder arthroplasty has become increasingly popular because of the improved implant design, porous ingrowth surface, and surgical techniques. When avoiding the risks of cement use, a press-fit arthroplasty stem that has been implanted may not feel immediately stable, especially if the medullary canal size is in between standard stem diameters. To help surgeons improve fixation and avoid overstuffing the medullary canal, we present the matchstick autograft augmentation technique. The use of humeral autograft, analogous to impaction grafting in hip arthroplasty, has been reported to have promising short-term outcomes 2,3 . This technique of using humeral autograft material, dubbed matchstick autografts because of their shape and size, allows for optimization of humeral stem stability with the option of smaller cementless humeral implants. By avoiding overstuffing of the medullary canal, this technique aims to reduce the incidences of intraoperative fracture, postoperative stress shielding, and potential implant loosening 4–6 . Description: Cementless reverse total shoulder arthroplasty is routinely performed via the anterosuperior approach 7 ; however, a deltopectoral approach can be utilized if desired. The canal is sequentially broached with implant trials until the tactile feedback demonstrates axial and rotational stability. In cases in which tactile feedback during implantation demonstrates slight movement, the smaller implant size can be selected and augmented with matchstick autograft. An oscillating saw is utilized to cut the edges of the previously resected humeral head in order to expose the subchondral bone surface. Graft sticks about 20 mm in length and 1 to 3 mm in width are then fashioned. Humeral trials are then implanted with the matchstick grafts placed lengthwise alongside the humeral stem. Axial and rotational press-fit is again assessed. If adequate, the formal humeral implant is selected and implanted in position. As in conventional impaction grafting, the grafts are compressed to the side of the humeral canal, but they offer more corticocancellous structure than bone chips. This technique is applicable even in some fracture scenarios. Alternatives: When a specific press-fit humeral stem size does not achieve adequate stability, there are typically 3 surgical alternatives. First, a larger stem size can be selected. Second, the implant can be inserted deeper to achieve press-fit stability. Third, cement can be added to fill the medullary canal and create immediate stability. Rationale: When implanting the humeral prosthesis, the operating surgeon’s primary goal is stem stability. When faced with lack of stability, the surgeon can select a larger humeral stem, risking stress shielding; implant the stem deeper, compromising length and risking humeral fracture; or consider a cemented implant. In order to minimize the risk of intraoperative cardiopulmonary events and complicated subsequent revision surgeries 8 , the use of cement should be avoided if at all possible. Shoulder surgeons have reported grafting techniques, analogous to hip impaction grafting, that have yielded good success 3 . The technique that we describe utilizes a matchstick structural autograft that helps improve cementless fixation in primary humeral implantation cases and allows for the use of a smaller stem. The structural shape of the graft allows this technique to be utilized even in selected proximal humeral fractures. Expected Outcomes: Other studies have reported on the use of softer cancellous autografts to stabilize humeral implants in shoulder arthroplasty. In a study of 286 arthroplasties with a minimum follow-up of 2 years, Lucas et al. reported that 267 humeral stems (93.3%) had not subsided 3 . Humphrey and Bravman used cancellous autograft to achieve metaphyseal centering of the humeral component in 53 patients, with no cases of humeral implant loosening at 12 months 2 . Lo et al. reported 91% tuberosity healing in their series of cementless reverse total shoulder arthroplasties augmented with matchstick autografts 1 , with no cases of aseptic humeral stem loosening. Montemaggi et al. used matchstick autografts to augment 46 primary cementless reverse total shoulder arthroplasties and found zero instances of humeral loosening at 1-year follow-up 9 . Important Tips: The strongest humeral matchstick grafts come from the subchondral surface. After creating the graft, it is palpated for structural integrity. A stiffer or softer graft can be chosen, depending on surgeon preference. Surgeons can try impacting the graft with humeral trials to assess the stem stability prior to final implantation. Acronyms and Abbreviations: RTSA = reverse total shoulder arthroplasty FX = fracture 3D CT = 3-dimensional computed tomography XR = x-ray FU = follow-up
- 3 October 2023
- Published by Elsevier in Gait & Posture
- Vol. 105, S6-S7
Gait deviation index to quantify the short-term effects of functional surgery on walking kinematics in patients with cerebral palsy. A prospective cohort study
- 3 October 2023
- Published by Elsevier in Gait & Posture
- Vol. 105, S6-S7
Gait deviation index to quantify the short-term effects of functional surgery on walking kinematics in patients with cerebral palsy. A prospective cohort study
- 1 July 2021
- Published by Wolters Kluwer Health in JBJS Essential Surgical Techniques
- Vol. 11 (3)
Comprehensive Modified Latarjet Technique
Background: The Latarjet surgical technique is one of the most effective and well-known techniques in the treatment of anterior shoulder instability 1 . The modified Latarjet technique is a history book of surgical details demonstrated by renowned masters of shoulder surgery. The procedure includes soft-tissue repair and osseous reconstruction to stabilize the glenohumeral joint in recurrent anterior instability. The procedure has been shown to have reliable success in reducing recurrent instability and minimizing risk of dislocation arthropathy 2–4 . Description: The Latarjet technique can be performed via a cosmetic axillary-based approach. The subscapularis is split horizontally without detachment as described by Neer 5 . The capsule is released like in a medially based T-plasty as described by Altchek et al. 6 . The coracoid osteotomy is performed with a 90° oscillating saw and prepared for en-face implantation as described by Edwards and Walch 7 . The inferior surface of the coracoid is decorticated and prepared per Molé 8 . Coracoid fixation is performed with two 3.5-mm cortical screws. The soft-tissue reconstruction is selectively tensioned per Warner et al. 9 . The capsular shift is augmented with a pants-over-vest repair per Kim et al. 10 . Alternatives: Nonoperative treatment in young patients with glenohumeral instability and bone loss can lead to recurrence rates as high as 87% 11 . Arthroscopic management with anterior capsulolabral repair and a remplissage procedure can be beneficial for patients with instability. In the setting of bone loss, arthroscopic repair is associated with failure rates as high as 75% 12 . Rationale: In the setting of glenoid and/or humeral bone loss, there is a loss of native osseous anatomy, leading to a higher risk of instability. Gerber and Nyffeler reported a >30% loss of compressive force when the vertical edge of the glenoid defect is greater than one-half of the glenoid diameter 13 . The Latarjet procedure is a reliable procedure that reconstructs the anterior osseous anatomy as well as the capsular laxity, restoring glenohumeral stability. When compared with arthroscopic labral repair, the Latarjet procedure is superior with more consistent improvements in functional outcomes with low risk of recurrence, even in high-risk populations of young, active athletes in contact sports 2,3 . Expected Outcomes: At our institution, a total of 34 patients underwent Latarjet reconstruction as described in the present article and videos from 2013 to 2018, with a minimum follow-up of 1 year. Among these patients, the mean Single Assessment Numeric Evaluation score was 90.7 (range, 70 to 100). There were 4 cases of recurrent instability with graft fracture or resorption (11.8%). Zimmermann et al. presented a series of Latarjet reconstructions with similar functional outcomes and a recurrence rate of 11% 4 . Meta-analysis of long-term Latarjet studies show high rates of return to sports and successful outcomes in 86% of cases, with an 8.5% recurrence rate 2 . Important Tips: The Latarjet procedure can be consistently performed with a subscapularis-sparing approach, which minimizes adverse comorbidities. Splitting the subscapularis at the inferior one-third junction will position the surgical window directly over the bottom half of the glenoid, which optimizes coracoid implantation. A medially based T-plasty will maximize the glenoid exposure for direct coracoid implantation. Subsequently, the capsule may be shifted for capsular imbrication. Low-profile, non-bulky retractors will help to improve visualization. Adjusting the arm is a key technique in performing this surgical procedure. This adjustment will help to shift the surgical window, expose key anatomic structures, and allow a capsular shift without overtensioning. This cannot be overstated.
- 1 July 2021
- Published by Wolters Kluwer Health in JBJS Essential Surgical Techniques
- Vol. 11 (3)
Comprehensive Modified Latarjet Technique
Background: The Latarjet surgical technique is one of the most effective and well-known techniques in the treatment of anterior shoulder instability 1 . The modified Latarjet technique is a history book of surgical details demonstrated by renowned masters of shoulder surgery. The procedure includes soft-tissue repair and osseous reconstruction to stabilize the glenohumeral joint in recurrent anterior instability. The procedure has been shown to have reliable success in reducing recurrent instability and minimizing risk of dislocation arthropathy 2–4 . Description: The Latarjet technique can be performed via a cosmetic axillary-based approach. The subscapularis is split horizontally without detachment as described by Neer 5 . The capsule is released like in a medially based T-plasty as described by Altchek et al. 6 . The coracoid osteotomy is performed with a 90° oscillating saw and prepared for en-face implantation as described by Edwards and Walch 7 . The inferior surface of the coracoid is decorticated and prepared per Molé 8 . Coracoid fixation is performed with two 3.5-mm cortical screws. The soft-tissue reconstruction is selectively tensioned per Warner et al. 9 . The capsular shift is augmented with a pants-over-vest repair per Kim et al. 10 . Alternatives: Nonoperative treatment in young patients with glenohumeral instability and bone loss can lead to recurrence rates as high as 87% 11 . Arthroscopic management with anterior capsulolabral repair and a remplissage procedure can be beneficial for patients with instability. In the setting of bone loss, arthroscopic repair is associated with failure rates as high as 75% 12 . Rationale: In the setting of glenoid and/or humeral bone loss, there is a loss of native osseous anatomy, leading to a higher risk of instability. Gerber and Nyffeler reported a >30% loss of compressive force when the vertical edge of the glenoid defect is greater than one-half of the glenoid diameter 13 . The Latarjet procedure is a reliable procedure that reconstructs the anterior osseous anatomy as well as the capsular laxity, restoring glenohumeral stability. When compared with arthroscopic labral repair, the Latarjet procedure is superior with more consistent improvements in functional outcomes with low risk of recurrence, even in high-risk populations of young, active athletes in contact sports 2,3 . Expected Outcomes: At our institution, a total of 34 patients underwent Latarjet reconstruction as described in the present article and videos from 2013 to 2018, with a minimum follow-up of 1 year. Among these patients, the mean Single Assessment Numeric Evaluation score was 90.7 (range, 70 to 100). There were 4 cases of recurrent instability with graft fracture or resorption (11.8%). Zimmermann et al. presented a series of Latarjet reconstructions with similar functional outcomes and a recurrence rate of 11% 4 . Meta-analysis of long-term Latarjet studies show high rates of return to sports and successful outcomes in 86% of cases, with an 8.5% recurrence rate 2 . Important Tips: The Latarjet procedure can be consistently performed with a subscapularis-sparing approach, which minimizes adverse comorbidities. Splitting the subscapularis at the inferior one-third junction will position the surgical window directly over the bottom half of the glenoid, which optimizes coracoid implantation. A medially based T-plasty will maximize the glenoid exposure for direct coracoid implantation. Subsequently, the capsule may be shifted for capsular imbrication. Low-profile, non-bulky retractors will help to improve visualization. Adjusting the arm is a key technique in performing this surgical procedure. This adjustment will help to shift the surgical window, expose key anatomic structures, and allow a capsular shift without overtensioning. This cannot be overstated.
- 22 April 2016
- Published by Springer Nature
- p. 5-11
Brachytherapy: A Journey of Hope in the Battle Against Cancer
- 22 April 2016
- Published by Springer Nature
- p. 5-11
Brachytherapy: A Journey of Hope in the Battle Against Cancer