Ziqi Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ziqi Wang has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Mani Srivastava
University of California, Los Angeles, USA
3 shared publications - Ankur Sarker
University Of California - Los Angeles, Los Angeles, CA, USA
1 shared publication - Benjamin M. Marlin
University of Massachusetts Amherst USA
1 shared publication Brian Wang
University of California, Los Angeles, Los Angeles, USA
1 shared publication- Colin Samplawski
University of Massachusetts
1 shared publication - Deepak Ganesan
Manning College of Information and Computer Sciences, University of Massachusetts Amherst, Amherst, Massachusetts, USA
1 shared publication
Latest Publications
- Open Access
MobiVital: Self-supervised Time-series Quality Estimation for Contactless Respiration Monitoring Using UWB Radar
Respiration waveforms are increasingly recognized as important biomarkers, offering insights beyond simple respiration rates, such as detecting breathing irregularities for disease diagnosis or monitoring breath patterns to guide rehabilitation training. Previous works in wireless respiration monitoring have primarily focused on estimating respiration rate, where the breath waveforms are often generated as a by-product. As a result, issues such as waveform deformation and inversion have largely been overlooked, reducing the signal's utility for applications requiring breathing waveforms. To address this problem, we present a novel approach, MobiVital, that improves the quality of respiration waveforms obtained from ultra-wideband (UWB) radar data. MobiVital combines a self-supervised autoregressive model for breathing waveform extraction with a biology-informed algorithm to detect and correct waveform inversions. To encourage reproducible research efforts for developing wireless vital signal monitoring systems, we also release a 12-person, 24-hour UWB radar vital signal dataset, with time-synchronized ground truth obtained from wearable sensors. Our results show that the respiration waveforms produced by our system exhibit a 7-34% increase in fidelity to the ground truth compared to the baselines and can benefit downstream tasks such as respiration rate estimation.
Open AccessMobiVital: Self-supervised Time-series Quality Estimation for Contactless Respiration Monitoring Using UWB Radar
Respiration waveforms are increasingly recognized as important biomarkers, offering insights beyond simple respiration rates, such as detecting breathing irregularities for disease diagnosis or monitoring breath patterns to guide rehabilitation training. Previous works in wireless respiration monitoring have primarily focused on estimating respiration rate, where the breath waveforms are often generated as a by-product. As a result, issues such as waveform deformation and inversion have largely been overlooked, reducing the signal's utility for applications requiring breathing waveforms. To address this problem, we present a novel approach, MobiVital, that improves the quality of respiration waveforms obtained from ultra-wideband (UWB) radar data. MobiVital combines a self-supervised autoregressive model for breathing waveform extraction with a biology-informed algorithm to detect and correct waveform inversions. To encourage reproducible research efforts for developing wireless vital signal monitoring systems, we also release a 12-person, 24-hour UWB radar vital signal dataset, with time-synchronized ground truth obtained from wearable sensors. Our results show that the respiration waveforms produced by our system exhibit a 7-34% increase in fidelity to the ground truth compared to the baselines and can benefit downstream tasks such as respiration rate estimation.
- Open Access
GDTM: An Indoor Geospatial Tracking Dataset with Distributed Multimodal Sensors
Constantly locating moving objects, i.e., geospatial tracking, is essential for autonomous building infrastructure. Accurate and robust geospatial tracking often leverages multimodal sensor fusion algorithms, which require large datasets with time-aligned, synchronized data from various sensor types. However, such datasets are not readily available. Hence, we propose GDTM, a nine-hour dataset for multimodal object tracking with distributed multimodal sensors and reconfigurable sensor node placements. Our dataset enables the exploration of several research problems, such as optimizing architectures for processing multimodal data, and investigating models' robustness to adverse sensing conditions and sensor placement variances. A GitHub repository containing the code, sample data, and checkpoints of this work is available at https://github.com/nesl/GDTM.
Open AccessGDTM: An Indoor Geospatial Tracking Dataset with Distributed Multimodal Sensors
Constantly locating moving objects, i.e., geospatial tracking, is essential for autonomous building infrastructure. Accurate and robust geospatial tracking often leverages multimodal sensor fusion algorithms, which require large datasets with time-aligned, synchronized data from various sensor types. However, such datasets are not readily available. Hence, we propose GDTM, a nine-hour dataset for multimodal object tracking with distributed multimodal sensors and reconfigurable sensor node placements. Our dataset enables the exploration of several research problems, such as optimizing architectures for processing multimodal data, and investigating models' robustness to adverse sensing conditions and sensor placement variances. A GitHub repository containing the code, sample data, and checkpoints of this work is available at https://github.com/nesl/GDTM.
- Open Access
- 4 July 2022
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 6 (2) , 1-34
Auritus
Smart ear-worn devices (called earables) are being equipped with various onboard sensors and algorithms, transforming earphones from simple audio transducers to multi-modal interfaces making rich inferences about human motion and vital signals. However, developing sensory applications using earables is currently quite cumbersome with several barriers in the way. First, time-series data from earable sensors incorporate information about physical phenomena in complex settings, requiring machine-learning (ML) models learned from large-scale labeled data. This is challenging in the context of earables because large-scale open-source datasets are missing. Secondly, the small size and compute constraints of earable devices make on-device integration of many existing algorithms for tasks such as human activity and head-pose estimation difficult. To address these challenges, we introduce Auritus, an extendable and open-source optimization toolkit designed to enhance and replicate earable applications. Auritus serves two primary functions. Firstly, Auritus handles data collection, pre-processing, and labeling tasks for creating customized earable datasets using graphical tools. The system includes an open-source dataset with 2.43 million inertial samples related to head and full-body movements, consisting of 34 head poses and 9 activities from 45 volunteers. Secondly, Auritus provides a tightly-integrated hardware-in-the-loop (HIL) optimizer and TinyML interface to develop lightweight and real-time machine-learning (ML) models for activity detection and filters for head-pose tracking. To validate the utlity of Auritus, we showcase three sample applications, namely fall detection, spatial audio rendering, and augmented reality (AR) interfacing. Auritus recognizes activities with 91% leave 1-out test accuracy (98% test accuracy) using real-time models as small as 6-13 kB. Our models are 98-740x smaller and 3-6% more accurate over the state-of-the-art. We also estimate head pose with absolute errors as low as 5 degrees using 20kB filters, achieving up to 1.6x precision improvement over existing techniques. We make the entire system open-source so that researchers and developers can contribute to any layer of the system or rapidly prototype their applications using our dataset and algorithms.
- 4 July 2022
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 6 (2) , 1-34
Open AccessAuritus
Smart ear-worn devices (called earables) are being equipped with various onboard sensors and algorithms, transforming earphones from simple audio transducers to multi-modal interfaces making rich inferences about human motion and vital signals. However, developing sensory applications using earables is currently quite cumbersome with several barriers in the way. First, time-series data from earable sensors incorporate information about physical phenomena in complex settings, requiring machine-learning (ML) models learned from large-scale labeled data. This is challenging in the context of earables because large-scale open-source datasets are missing. Secondly, the small size and compute constraints of earable devices make on-device integration of many existing algorithms for tasks such as human activity and head-pose estimation difficult. To address these challenges, we introduce Auritus, an extendable and open-source optimization toolkit designed to enhance and replicate earable applications. Auritus serves two primary functions. Firstly, Auritus handles data collection, pre-processing, and labeling tasks for creating customized earable datasets using graphical tools. The system includes an open-source dataset with 2.43 million inertial samples related to head and full-body movements, consisting of 34 head poses and 9 activities from 45 volunteers. Secondly, Auritus provides a tightly-integrated hardware-in-the-loop (HIL) optimizer and TinyML interface to develop lightweight and real-time machine-learning (ML) models for activity detection and filters for head-pose tracking. To validate the utlity of Auritus, we showcase three sample applications, namely fall detection, spatial audio rendering, and augmented reality (AR) interfacing. Auritus recognizes activities with 91% leave 1-out test accuracy (98% test accuracy) using real-time models as small as 6-13 kB. Our models are 98-740x smaller and 3-6% more accurate over the state-of-the-art. We also estimate head pose with absolute errors as low as 5 degrees using 20kB filters, achieving up to 1.6x precision improvement over existing techniques. We make the entire system open-source so that researchers and developers can contribute to any layer of the system or rapidly prototype their applications using our dataset and algorithms.
- Open Access
- 18 May 2021
- Published by Association for Computing Machinery (ACM)
- Vol. 2021, 386-387
Protecting User Data Privacy with Adversarial Perturbations
The increased availability of on-body sensors gives researchers access to rich time-series data, many of which are related to human health conditions. Sharing such data can allow cross-institutional collaborations that create advanced data-driven models to make inferences on human well-being. However, such data are usually considered privacy-sensitive, and publicly sharing this data may incur significant privacy concerns. In this work, we seek to protect clinical time-series data against membership inference attacks, while maximally retaining the data utility. We achieve this by adding an imperceptible noise to the raw data. Known as adversarial perturbations, the noise is specially trained to force a deep learning model to make inference mistakes (in our case, mispredicting user identities). Our preliminary results show that our solution can better protect the data from membership inference attacks than the baselines, while succeeding in all the designed data quality checks.
- 18 May 2021
- Published by Association for Computing Machinery (ACM)
- Vol. 2021, 386-387
Open AccessProtecting User Data Privacy with Adversarial Perturbations
The increased availability of on-body sensors gives researchers access to rich time-series data, many of which are related to human health conditions. Sharing such data can allow cross-institutional collaborations that create advanced data-driven models to make inferences on human well-being. However, such data are usually considered privacy-sensitive, and publicly sharing this data may incur significant privacy concerns. In this work, we seek to protect clinical time-series data against membership inference attacks, while maximally retaining the data utility. We achieve this by adding an imperceptible noise to the raw data. Known as adversarial perturbations, the noise is specially trained to force a deep learning model to make inference mistakes (in our case, mispredicting user identities). Our preliminary results show that our solution can better protect the data from membership inference attacks than the baselines, while succeeding in all the designed data quality checks.