Matteo Matteucci
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Matteo Matteucci has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Bonarini
Politecnico di Milano
1 shared publication - Anna Maria Bianchi
Department of Electronic, Information and Bioengineering, Politecnico Di Milano, Milan, Italy
1 shared publication - Davide D. Ruini
Dept. of Electronics and Information, Politecnico di Milano, Pzza. Leonardo da Vinci 32, Italy
1 shared publication - Lorenzo Mussone
Department of Architecture, Built Environment and Construction Engineering, Politecnico di Milano, 20133 Milan, Italy
1 shared publication - Martín Oswaldo Méndez
Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133 Milan, Italy
1 shared publication - Omar P. Villantieri
Dept. of Biomedical Engineering, Politecnico di Milano, Pzza. Leonardo da Vinci 32, Italy
1 shared publication
Latest Publications
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 6105-6108
Detection of Sleep Apnea from surface ECG based on features extracted by an Autoregressive Model
This study proposes an alternative evaluation of obstructive sleep apnea (OSA) based on ECG signal during sleep time. OSA is a common sleep disorder produced by repetitive occlusions in the upper airways. This respiratory disturbance produces a specific pattern on ECG. Extraction of ECG characteristics, as heart rate variability (HRV) and peak R area, offers alternative measures for a sleep apnea pre-diagnosis. 50 recordings coming from the apnea Physionet database were used in the analysis, this database is part of the 70 recordings used for the Computer in Cardiology challenge celebrated in 2000. A bivariate autoregressive model was used to evaluate beat-by-beat power spectral density of HRV and R peak area. K-nearest neighbor (KNN) supervised learning classifier was employed for categorizing apnea events from normal ones, on a minute-by-minute basis for each recording. Data were split into two sets, training and testing set, each one with 25 recordings. The classification results showed an accuracy higher than 85% in both training and testing. In addition it was possible to separate completely between apnea and normal subjects and almost completely among apnea, normal and borderline subjects.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 6105-6108
Detection of Sleep Apnea from surface ECG based on features extracted by an Autoregressive Model
This study proposes an alternative evaluation of obstructive sleep apnea (OSA) based on ECG signal during sleep time. OSA is a common sleep disorder produced by repetitive occlusions in the upper airways. This respiratory disturbance produces a specific pattern on ECG. Extraction of ECG characteristics, as heart rate variability (HRV) and peak R area, offers alternative measures for a sleep apnea pre-diagnosis. 50 recordings coming from the apnea Physionet database were used in the analysis, this database is part of the 70 recordings used for the Computer in Cardiology challenge celebrated in 2000. A bivariate autoregressive model was used to evaluate beat-by-beat power spectral density of HRV and R peak area. K-nearest neighbor (KNN) supervised learning classifier was employed for categorizing apnea events from normal ones, on a minute-by-minute basis for each recording. Data were split into two sets, training and testing set, each one with 25 recordings. The classification results showed an accuracy higher than 85% in both training and testing. In addition it was possible to separate completely between apnea and normal subjects and almost completely among apnea, normal and borderline subjects.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE International Fuzzy Systems Conference
- No. 10987584,p. 1-6
FIXCS: a Fuzzy Implementation of XCS
We present FIXCS (fuzzy implementation of XCS), a learning classifier system that extend the accuracy-based extended classifier system (XCS) by allowing to match real-valued input by fuzzy sets, and to produce a fuzzy output, then translated into real values. This work gives XCS the ability to face real-valued problems with a fuzzy model that approximates a real valued function better than the original, interval-based model. First results show that, as expected, the learning time is longer, but the obtained fuzzy system is more robust than the interval-based one.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE International Fuzzy Systems Conference
- No. 10987584,p. 1-6
FIXCS: a Fuzzy Implementation of XCS
We present FIXCS (fuzzy implementation of XCS), a learning classifier system that extend the accuracy-based extended classifier system (XCS) by allowing to match real-valued input by fuzzy sets, and to produce a fuzzy output, then translated into real values. This work gives XCS the ability to face real-valued problems with a fuzzy model that approximates a real valued function better than the original, interval-based model. First results show that, as expected, the learning time is longer, but the obtained fuzzy system is more robust than the interval-based one.
- 1 January 2006
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 39 (12) , 165-170
OD MATRICES ESTIMATION FROM LINK FLOWS BY NEURAL NETWORKS AND PCA
- 1 January 2006
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 39 (12) , 165-170
OD MATRICES ESTIMATION FROM LINK FLOWS BY NEURAL NETWORKS AND PCA