Chun-Lien Su
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chun-Lien Su has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Bo-Yuan Jau
Department of Marine Engineering, National Kaohsiung Marine University, Kaohsiung, TAIWAN 805
2 shared publications - Jen-Hao Teng
Department of Electrical Engineering, National Sun Yat-sen University, Kaohsiung 80424, Taiwan
1 shared publication
Latest Publications
- 1 November 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Visualization of Wide Area Dynamics in Power Network for Oscillatory Stability Assessment
Many countries around the world had suffered blackout incidents due to inter-area oscillations in recent decades. Analysis of system wide oscillatory stability requires a more effective engineering tool for modeling the wide area dynamics in power network. This paper proposes a data visualization based method for assessing the wide area power oscillatory stability. The phasor measurements are used and estimated to obtain more real-time system operating data by using a linear state estimator. The phasor data are then used as the input data for visualizing wide area dynamics. Several visualization modules for displaying the phased angle dynamics are discussed and implemented. Test results of application of the proposed method to an inter-area oscillation event are reported. Sensitivity of the performance of the proposed visualization modules to different system sizes is illustrated.
- 1 November 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Visualization of Wide Area Dynamics in Power Network for Oscillatory Stability Assessment
Many countries around the world had suffered blackout incidents due to inter-area oscillations in recent decades. Analysis of system wide oscillatory stability requires a more effective engineering tool for modeling the wide area dynamics in power network. This paper proposes a data visualization based method for assessing the wide area power oscillatory stability. The phasor measurements are used and estimated to obtain more real-time system operating data by using a linear state estimator. The phasor data are then used as the input data for visualizing wide area dynamics. Several visualization modules for displaying the phased angle dynamics are discussed and implemented. Test results of application of the proposed method to an inter-area oscillation event are reported. Sensitivity of the performance of the proposed visualization modules to different system sizes is illustrated.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Effects of Distribution System Operations on Voltage Profiles in Distribution Grids Connected Wind Power Generation
Wind power is one of the most common renewable energy sources and its penetration in distribution grids would be further increasing. For distribution grids connected wind power generation, the steady-state voltage variation is an important issue for the system planning purpose. At the distribution level, there are a number of attributes that can influence the voltage profiles; therefore, the analysis of the voltage variations in the distribution grids with wind turbines requires detailed distribution operation models. To fully evaluate the actual nodal voltage profiles in distribution grids connected wind power generation, the distribution system operation uncertainties including daily time varying load, stochastic wind power generation, network reconfiguration, and voltage control devices operation are modeled and taken into account in the analysis. A probabilistic load flow method based an efficient algorithm is used to obtain the voltage distributions in a fixed network configuration. The final distributions are evaluated based on the probability associated with each configuration. The voltage control devices then are operated to improve voltage distributions based on an AC sensitivity matrix. The proposed probabilistic models can provide the actual voltage distributions in the future system and be used for assessing the effect of wind power on distribution operating performance. Test results of a modified IEEE 13 node feeder test system are presented.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Effects of Distribution System Operations on Voltage Profiles in Distribution Grids Connected Wind Power Generation
Wind power is one of the most common renewable energy sources and its penetration in distribution grids would be further increasing. For distribution grids connected wind power generation, the steady-state voltage variation is an important issue for the system planning purpose. At the distribution level, there are a number of attributes that can influence the voltage profiles; therefore, the analysis of the voltage variations in the distribution grids with wind turbines requires detailed distribution operation models. To fully evaluate the actual nodal voltage profiles in distribution grids connected wind power generation, the distribution system operation uncertainties including daily time varying load, stochastic wind power generation, network reconfiguration, and voltage control devices operation are modeled and taken into account in the analysis. A probabilistic load flow method based an efficient algorithm is used to obtain the voltage distributions in a fixed network configuration. The final distributions are evaluated based on the probability associated with each configuration. The voltage control devices then are operated to improve voltage distributions based on an AC sensitivity matrix. The proposed probabilistic models can provide the actual voltage distributions in the future system and be used for assessing the effect of wind power on distribution operating performance. Test results of a modified IEEE 13 node feeder test system are presented.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Visualization of Large-Scale Power System Operations Using Phasor Measurements
Many countries around the world had experienced large-scale blackout incidents in recent years. Preventing the large-scale blackout or reducing its impact requires an effective monitoring of the system state of the entire grid during emergency operations. Visualizations that provide a wide-scale and animating display to graphically show important system quantities are an effective way to assist the operators in assessing system status during emergency operations. The availability of real-time system operating data is the main problem when visualizing the emergency operations. To provide the adequate "real-time" system operating information for monitoring system operations, a new procedure for monitoring large-scale power system operations is proposed in this paper. Instead of using the system state solution obtained from state estimation (SE), synchronized phasor measurements are used in this paper for monitoring the entire grid operations. Since the phasor measurements only exist at a few buses, a linear SE is used to obtain more phasor data. The voltages of the estimated phasor data are then visualized using contours. The proposed method is tested on an actual disturbance event occurred in Taiwan power system. Performance of the proposed method is ensured through several sensitivity analyses.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Visualization of Large-Scale Power System Operations Using Phasor Measurements
Many countries around the world had experienced large-scale blackout incidents in recent years. Preventing the large-scale blackout or reducing its impact requires an effective monitoring of the system state of the entire grid during emergency operations. Visualizations that provide a wide-scale and animating display to graphically show important system quantities are an effective way to assist the operators in assessing system status during emergency operations. The availability of real-time system operating data is the main problem when visualizing the emergency operations. To provide the adequate "real-time" system operating information for monitoring system operations, a new procedure for monitoring large-scale power system operations is proposed in this paper. Instead of using the system state solution obtained from state estimation (SE), synchronized phasor measurements are used in this paper for monitoring the entire grid operations. Since the phasor measurements only exist at a few buses, a linear SE is used to obtain more phasor data. The voltages of the estimated phasor data are then visualized using contours. The proposed method is tested on an actual disturbance event occurred in Taiwan power system. Performance of the proposed method is ensured through several sensitivity analyses.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Industry Applications Annual Meeting
- Vol. 3 (01972618) , 1402-1409
Economic Evaluation of a Distribution Automation Project
To deal with the deregulated challenges in the future power system operations, Taiwan Power Company (Taipower) has taken a strategic approach to implement an extensive distribution automation (DA) project including feeder automation, trouble call management, load management, and remote metering functions in its Tai-Chung District. The project was completed in December 2002. For future extension purposes, Taipower tries to develop a comprehensive generalized step-by-step methodology for economic evaluation of the DA project. This paper presents the methodology and results for the economic evaluation of Tai-Chung DA project. The potential benefits of the implemented DA functions are quantified using standard mathematic formulas. An economic evaluation method using value-based analysis and present worth analysis is performed to identify the most beneficial functions in the Taipower's implemented DA functions. Those DA functions that have great benefits should have high priority to be implemented in other distribution districts. Besides, in order to find the candidate feeders for further feeder automation extension, the sensitivity analysis of the benefit/cost ratio with respect to different customer types, feeder loads, feeder lengths, numbers of switch and failure rates is also conducted. Accordingly, the optimum number of switch can be determined under the expected service reliability. The results and formulas obtained in this paper can also be used for return-of-investment, or possible performance measure of the DA systems
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Industry Applications Annual Meeting
- Vol. 3 (01972618) , 1402-1409
Economic Evaluation of a Distribution Automation Project
To deal with the deregulated challenges in the future power system operations, Taiwan Power Company (Taipower) has taken a strategic approach to implement an extensive distribution automation (DA) project including feeder automation, trouble call management, load management, and remote metering functions in its Tai-Chung District. The project was completed in December 2002. For future extension purposes, Taipower tries to develop a comprehensive generalized step-by-step methodology for economic evaluation of the DA project. This paper presents the methodology and results for the economic evaluation of Tai-Chung DA project. The potential benefits of the implemented DA functions are quantified using standard mathematic formulas. An economic evaluation method using value-based analysis and present worth analysis is performed to identify the most beneficial functions in the Taipower's implemented DA functions. Those DA functions that have great benefits should have high priority to be implemented in other distribution districts. Besides, in order to find the candidate feeders for further feeder automation extension, the sensitivity analysis of the benefit/cost ratio with respect to different customer types, feeder loads, feeder lengths, numbers of switch and failure rates is also conducted. Accordingly, the optimum number of switch can be determined under the expected service reliability. The results and formulas obtained in this paper can also be used for return-of-investment, or possible performance measure of the DA systems