Chalasani Chiranjeevi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chalasani Chiranjeevi has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Tangellapalli Srinivas
Department of Mechanical Engineering, Dr. B. R. Ambedkar National Institute of Technology, Jalandhar, India
5 shared publications Rajesh S
2 shared publicationsAsif Afzal
1 shared publicationB. Vijayaraj
Department of Engineering, University of Technology and Applied Sciences-al Mussanah, Oman
1 shared publicationC Ahamed Saleel
1 shared publicationC. C. Mohan
Department of Engineering, University of Technology and Applied Sciences-al Mussanah, Oman
1 shared publication
Latest Publications
- Top Cited PapersOpen Access
- 19 January 2026
- Published by Elsevier in Results in Engineering
- Vol. 29
Experimental investigation on the hybrid PVT-solar still with rotating cylinder for enhanced electrical power and freshwater production
- 19 January 2026
- Published by Elsevier in Results in Engineering
- Vol. 29
Top Cited PapersOpen AccessExperimental investigation on the hybrid PVT-solar still with rotating cylinder for enhanced electrical power and freshwater production
- Open Access
- 15 July 2025
- Published by Elsevier in Energy Nexus
- Vol. 19
Advancing sustainable water-energy solutions through a hybrid photovoltaic-thermal stepped solar still
- 15 July 2025
- Published by Elsevier in Energy Nexus
- Vol. 19
Open AccessAdvancing sustainable water-energy solutions through a hybrid photovoltaic-thermal stepped solar still
- Open Access
- 17 April 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 71
Techno-economic analysis of a hybrid thermal desalination system integrated with a PVT collector
- 17 April 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 71
Open AccessTechno-economic analysis of a hybrid thermal desalination system integrated with a PVT collector
- 13 March 2024
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 46 (1) , 3793-3806
Experimental investigations on PVT-integrated hybrid desalination system: Energy, exergy, and economic analysis
- 13 March 2024
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 46 (1) , 3793-3806
Experimental investigations on PVT-integrated hybrid desalination system: Energy, exergy, and economic analysis
- Open Access
- 4 August 2023
- Published by Springer Nature in Research Square
Experimental investigation of a novel hybrid desalination system using photovoltaic-thermal (PVT) collector with energy, exergy, environmental and economic (4E) analysis
Freshwater and clean energy are essentially required for comfortable habitats living on the globe. The increasing demand for these can be accomplished with sustainable technologies like photovoltaics, solar desalination and their combinations. The current research focuses on the experimental evaluation of hybrid thermal desalination integrated with a photovoltaic-thermal (PVT) panel by energy, exergy, environmental and economic analysis. The proposed integrated thermal desalination system is a combination of a stepped solar still (SSS) and a humidification dehumidification (HD) system. A laboratory-level indigenous hybrid desalination unit is designed, developed and tested in the actual outdoor conditions of Vellore, India during the third week of May 2023. A unique novel bi-directional serpentine flow thermal absorber-based PVT panel is used to preheat saline water entering stepped solar still. The rejected brine from SSS is used in the HD system for further extraction of freshwater. Experiments were conducted for a saline water flow range of 1.5 to 3 litres per minute. The experimental results depict that the PVT average electrical efficiency is enhanced by 0.4 % over the reference PV panel. Daily potable water production of the hybrid PVT-SSS-HD unit is observed in the range of 6400 to 7450 ml/m2. Further, the gain output ratio of the hybrid system is observed between 5.99 and 6.35. The overall efficiency and the unit litre freshwater cost in USD of the hybrid system are observed in the range of 61.17 % to 67.71 % and 0.079 to 0.068 respectively.
- 4 August 2023
- Published by Springer Nature in Research Square
Open AccessExperimental investigation of a novel hybrid desalination system using photovoltaic-thermal (PVT) collector with energy, exergy, environmental and economic (4E) analysis
Freshwater and clean energy are essentially required for comfortable habitats living on the globe. The increasing demand for these can be accomplished with sustainable technologies like photovoltaics, solar desalination and their combinations. The current research focuses on the experimental evaluation of hybrid thermal desalination integrated with a photovoltaic-thermal (PVT) panel by energy, exergy, environmental and economic analysis. The proposed integrated thermal desalination system is a combination of a stepped solar still (SSS) and a humidification dehumidification (HD) system. A laboratory-level indigenous hybrid desalination unit is designed, developed and tested in the actual outdoor conditions of Vellore, India during the third week of May 2023. A unique novel bi-directional serpentine flow thermal absorber-based PVT panel is used to preheat saline water entering stepped solar still. The rejected brine from SSS is used in the HD system for further extraction of freshwater. Experiments were conducted for a saline water flow range of 1.5 to 3 litres per minute. The experimental results depict that the PVT average electrical efficiency is enhanced by 0.4 % over the reference PV panel. Daily potable water production of the hybrid PVT-SSS-HD unit is observed in the range of 6400 to 7450 ml/m2. Further, the gain output ratio of the hybrid system is observed between 5.99 and 6.35. The overall efficiency and the unit litre freshwater cost in USD of the hybrid system are observed in the range of 61.17 % to 67.71 % and 0.079 to 0.068 respectively.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2943 (1)
Comparative analysis of solar-thermal and solar - Photovoltaic powered vapor absorption refrigeration systems
The research paper presents an experimental investigation into the functioning of an absorption refrigerator, executed at the University of Technology and Applied Sciences-Al Musannah in Oman. The study focused on comparing the effects of two types of input energies, solar-thermal and solar-electrical, on the system’s functionality. This was done in an effort to identify a more environmentally friendly alternative to traditional cooling systems, such as vapor compression refrigeration systems (VCRS), which contribute to environmental problems through greenhouse gas emissions. Using a data acquisition system, key parameters including temperatures at specific points, solar intensity, fluid flow rates, and electric power output were collected and analyzed. The effectiveness of the system, as measured by the coefficient of performance (COP) of the system, under diverse operating settings was assessed. The findings were subsequently interpreted and illustrated. One key discovery was that the system’s COP was approximately 13% higher when powered by solar-electric energy than solar-thermal energy. Furthermore, using solar-electric energy resulted in a nearly 14% increase in the refrigeration effect compared to solar-thermal energy, indicating the potential of solar-powered vapor absorption refrigeration systems as an eco-friendly option.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2943 (1)
Open AccessComparative analysis of solar-thermal and solar - Photovoltaic powered vapor absorption refrigeration systems
The research paper presents an experimental investigation into the functioning of an absorption refrigerator, executed at the University of Technology and Applied Sciences-Al Musannah in Oman. The study focused on comparing the effects of two types of input energies, solar-thermal and solar-electrical, on the system’s functionality. This was done in an effort to identify a more environmentally friendly alternative to traditional cooling systems, such as vapor compression refrigeration systems (VCRS), which contribute to environmental problems through greenhouse gas emissions. Using a data acquisition system, key parameters including temperatures at specific points, solar intensity, fluid flow rates, and electric power output were collected and analyzed. The effectiveness of the system, as measured by the coefficient of performance (COP) of the system, under diverse operating settings was assessed. The findings were subsequently interpreted and illustrated. One key discovery was that the system’s COP was approximately 13% higher when powered by solar-electric energy than solar-thermal energy. Furthermore, using solar-electric energy resulted in a nearly 14% increase in the refrigeration effect compared to solar-thermal energy, indicating the potential of solar-powered vapor absorption refrigeration systems as an eco-friendly option.
- Open Access
- 1 December 2016
- Published by Elsevier in Energy Procedia
- Vol. 90, 283-291
Experimental Analysis of Augmented Desalination by Cooling Integration
- 1 December 2016
- Published by Elsevier in Energy Procedia
- Vol. 90, 283-291
Open AccessExperimental Analysis of Augmented Desalination by Cooling Integration
- 11 October 2016
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 9 (1) , 011007
Experimental and Computational Fluid Dynamics Studies on Dehumidifier in a Combined Cooling and Desalination Plant
Humidification–dehumidification (HDH) desalination is a simple technique to produce desalinated water from saline water. Dehumidifier is a key component in the HDH system, which influences the desalination yield. In the current work, a three-dimensional multiphase numerical simulation study is carried out on third dehumidifier alone to evaluate its performance using computational fluid dynamics (CFD) code. The simulation result is validated with experimental readings, and it is found that there exists a very close agreement between the predicted and the experimental readings. The key parameters influencing the dehumidifier performance are chilled water temperature, humid air temperature, and volume fraction. Experiments are carried out on the combined two stage HDH plant at different hot water temperature and flow rates. A detailed study of dehumidification process is carried out using ansys cfx 15.0 tool by solving the governing equations, namely, mass, momentum, and energy, with turbulence modeled through shear stress transport (SST) k–ω model of closure. Multiphase is solved using a free-surface multiphase model. The measured average cooled air temperature and relative humidity (RH) at the exit of third dehumidifier are 21 °C and 67%. The desalinated water produced at a hot water flow of 100 LPH is found as 2205 ml/h from the experiments. The CFD results are deviated by 0.41%, 6.45%, and −0.70% with that of experimental results at the dehumidifier for air temperature, velocity, and chilled water temperature, respectively.
- 11 October 2016
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 9 (1) , 011007
Experimental and Computational Fluid Dynamics Studies on Dehumidifier in a Combined Cooling and Desalination Plant
Humidification–dehumidification (HDH) desalination is a simple technique to produce desalinated water from saline water. Dehumidifier is a key component in the HDH system, which influences the desalination yield. In the current work, a three-dimensional multiphase numerical simulation study is carried out on third dehumidifier alone to evaluate its performance using computational fluid dynamics (CFD) code. The simulation result is validated with experimental readings, and it is found that there exists a very close agreement between the predicted and the experimental readings. The key parameters influencing the dehumidifier performance are chilled water temperature, humid air temperature, and volume fraction. Experiments are carried out on the combined two stage HDH plant at different hot water temperature and flow rates. A detailed study of dehumidification process is carried out using ansys cfx 15.0 tool by solving the governing equations, namely, mass, momentum, and energy, with turbulence modeled through shear stress transport (SST) k–ω model of closure. Multiphase is solved using a free-surface multiphase model. The measured average cooled air temperature and relative humidity (RH) at the exit of third dehumidifier are 21 °C and 67%. The desalinated water produced at a hot water flow of 100 LPH is found as 2205 ml/h from the experiments. The CFD results are deviated by 0.41%, 6.45%, and −0.70% with that of experimental results at the dehumidifier for air temperature, velocity, and chilled water temperature, respectively.
- Open Access
- 1 September 2016
- Published by Elsevier in Alexandria Engineering Journal
- Vol. 55 (3) , 1961-1967
Influence of vapor absorption cooling on humidification-dehumidification (HDH) desalination
- 1 September 2016
- Published by Elsevier in Alexandria Engineering Journal
- Vol. 55 (3) , 1961-1967
Open AccessInfluence of vapor absorption cooling on humidification-dehumidification (HDH) desalination
- 1 November 2015
- Published by Elsevier in Desalination
- Vol. 376, 9-16
Experimental and simulation studies on two stage humidification–dehumidification desalination and cooling plant
- 1 November 2015
- Published by Elsevier in Desalination
- Vol. 376, 9-16
Experimental and simulation studies on two stage humidification–dehumidification desalination and cooling plant