Nada Hegazy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nada Hegazy has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
- Robert Delatolla
Department of Civil Engineering, University of Ottawa, Ottawa, ON, Canada
6 shared publications Shen Wan
Department of Civil Engineering
6 shared publicationsElizabeth Renouf
University of Ottawa, Ottawa, Ontario, Canada
5 shared publicationsPervez Kabir
Department of Civil Engineering, University of Ottawa, Ottawa, Ontario, Canada
5 shared publicationsFelix Addo
Department of Civil Engineering
4 shared publicationsÉlisabeth Mercier
Department of Civil Engineering
4 shared publications
Latest Publications
- Open Access
Twelve Distinct Laboratory Methods Used to Measure SARS-CoV-2 in Wastewaters throughout a Three-Year Ontario-Wide, Canada Study: Impact on Public Health Interpretation of Disease Incidence
Wastewater and environmental monitoring (WEM) was a critical public health surveillance tool for SARS-CoV-2 surveillance during the COVID-19 Pandemic. However, substantial methodological heterogeneity across laboratories continues to challenge the interpretation and thus compromise the actionability of resulting WEM measurements. This study quantifies interlaboratory concordance in SARS-CoV-2 WEM measurements using influent wastewater samples collected between September 2021 and January 2024 at a single wastewater treatment facility within the Ontario Wastewater Surveillance Initiative, analyzed independently by 12 laboratories using their routine methods. In the absence of a known true viral concentration, interlaboratory WEM measurements were evaluated against a facility-specific longitudinal benchmark derived from routine surveillance at the source facility and correlated to clinical surveillance metrics. Concordance was assessed across four WEM measurement units commonly used in practice: SARS-CoV-2 copies/mL, SARS-CoV-2 copies/copies of PMMoV, and their standardized counterpart wastewater viral activity level (WVAL) units of WVAL-standardized SARS-CoV-2 copies/mL and WVAL-standardized SARS-CoV-2 copies/copies of PMMoV. Measurements in each unit were analyzed using complementary analytical frameworks, including categorical concordance metrics, principal component analysis, and linear mixed-effects modelling. Across the study period, interlaboratory measurements consistently captured benchmark temporal dynamics, including major peaks and periods of low activity, but showed substantial variation in magnitude and public-health interpretation across laboratory methods. Concordance was strongest during epidemiological extremes and deteriorated during transitional periods, increasing the risk of misclassification with potentially implications for public health decision-making. To explore potential laboratory methodological drivers of agreement, associations between the benchmark concordance and the laboratory-specific concentration, extraction, and RT-qPCR analytical steps were assessed using Fisher’s exact tests, alongside extracted-mass threshold analyses. No single methodological factor showed a statistically significant association with benchmark concordance in this study; however, several parameters, including RNA template volume, total RT-qPCR reaction volume, and extracted mass of analyzed settled solids, may warrant further investigation in future studies.
Open AccessTwelve Distinct Laboratory Methods Used to Measure SARS-CoV-2 in Wastewaters throughout a Three-Year Ontario-Wide, Canada Study: Impact on Public Health Interpretation of Disease Incidence
Wastewater and environmental monitoring (WEM) was a critical public health surveillance tool for SARS-CoV-2 surveillance during the COVID-19 Pandemic. However, substantial methodological heterogeneity across laboratories continues to challenge the interpretation and thus compromise the actionability of resulting WEM measurements. This study quantifies interlaboratory concordance in SARS-CoV-2 WEM measurements using influent wastewater samples collected between September 2021 and January 2024 at a single wastewater treatment facility within the Ontario Wastewater Surveillance Initiative, analyzed independently by 12 laboratories using their routine methods. In the absence of a known true viral concentration, interlaboratory WEM measurements were evaluated against a facility-specific longitudinal benchmark derived from routine surveillance at the source facility and correlated to clinical surveillance metrics. Concordance was assessed across four WEM measurement units commonly used in practice: SARS-CoV-2 copies/mL, SARS-CoV-2 copies/copies of PMMoV, and their standardized counterpart wastewater viral activity level (WVAL) units of WVAL-standardized SARS-CoV-2 copies/mL and WVAL-standardized SARS-CoV-2 copies/copies of PMMoV. Measurements in each unit were analyzed using complementary analytical frameworks, including categorical concordance metrics, principal component analysis, and linear mixed-effects modelling. Across the study period, interlaboratory measurements consistently captured benchmark temporal dynamics, including major peaks and periods of low activity, but showed substantial variation in magnitude and public-health interpretation across laboratory methods. Concordance was strongest during epidemiological extremes and deteriorated during transitional periods, increasing the risk of misclassification with potentially implications for public health decision-making. To explore potential laboratory methodological drivers of agreement, associations between the benchmark concordance and the laboratory-specific concentration, extraction, and RT-qPCR analytical steps were assessed using Fisher’s exact tests, alongside extracted-mass threshold analyses. No single methodological factor showed a statistically significant association with benchmark concordance in this study; however, several parameters, including RNA template volume, total RT-qPCR reaction volume, and extracted mass of analyzed settled solids, may warrant further investigation in future studies.
- Open Access
- 7 July 2025
- Published by American Chemical Society (ACS) in ACS ES&T Water
- Vol. 5 (8) , 4472-4481
Optimization of the Primary Sludge Processing Method for Wastewater Genomic Surveillance of SARS-CoV-2
Wastewater genomic surveillance (WWGS) of SARS-CoV-2 is typically performed using influent wastewater, but the approach is challenging due to degradation as well as low target concentrations in wastewater. This could be alleviated by utilizing primary sludge; however, this matrix is prone to sequencing library failures. Our study focuses on developing a robust primary sludge-based SARS-CoV-2 genome sequencing method. The study was conducted using 30 parallel influent wastewater and primary sludge samples collected during three different time periods, under three clinically predominant SARS-CoV-2 Omicron lineages in Ottawa, Canada. Results showed that our approach consistently recovered near-complete (≥90%) SARS-CoV-2 genomes from both influent wastewater and primary sludge samples. Prevalent lineage and single nucleotide variant (SNV) profiles were identical (p > 0.05) between influent wastewater and primary sludge. Further analysis indicated that a similar (p > 0.05) number of rare SNVs were detected between influent wastewater and primary sludge. Overall, our approach enables the sequencing of the most concentrated sources of genetic material within the wastewater matrix, providing valuable insights for public health forecasting of infectious disease prevalence beyond the COVID-19 pandemic.
- 7 July 2025
- Published by American Chemical Society (ACS) in ACS ES&T Water
- Vol. 5 (8) , 4472-4481
Open AccessOptimization of the Primary Sludge Processing Method for Wastewater Genomic Surveillance of SARS-CoV-2
Wastewater genomic surveillance (WWGS) of SARS-CoV-2 is typically performed using influent wastewater, but the approach is challenging due to degradation as well as low target concentrations in wastewater. This could be alleviated by utilizing primary sludge; however, this matrix is prone to sequencing library failures. Our study focuses on developing a robust primary sludge-based SARS-CoV-2 genome sequencing method. The study was conducted using 30 parallel influent wastewater and primary sludge samples collected during three different time periods, under three clinically predominant SARS-CoV-2 Omicron lineages in Ottawa, Canada. Results showed that our approach consistently recovered near-complete (≥90%) SARS-CoV-2 genomes from both influent wastewater and primary sludge samples. Prevalent lineage and single nucleotide variant (SNV) profiles were identical (p > 0.05) between influent wastewater and primary sludge. Further analysis indicated that a similar (p > 0.05) number of rare SNVs were detected between influent wastewater and primary sludge. Overall, our approach enables the sequencing of the most concentrated sources of genetic material within the wastewater matrix, providing valuable insights for public health forecasting of infectious disease prevalence beyond the COVID-19 pandemic.
- Open Access
- 22 June 2025
- Published by Elsevier in Water Research
- Vol. 285, 124071
Passive sampling for genomic surveillance of SARS-CoV-2 in wastewater resource recovery facility: Insights for pandemic preparedness
- 22 June 2025
- Published by Elsevier in Water Research
- Vol. 285, 124071
Open AccessPassive sampling for genomic surveillance of SARS-CoV-2 in wastewater resource recovery facility: Insights for pandemic preparedness
- Open Access
- 7 March 2025
- Published by American Chemical Society (ACS) in ACS ES&T Water
- Vol. 5 (4) , 1605-1619
Variability of Clinical Metrics in Small Population Communities Drive Perceived Wastewater and Environmental Surveillance Data Quality: Ontario, Canada-Wide Study
The emergence of COVID-19 in Canada has led to over 4.9 million cases and 59,000 deaths by May 2024. Traditional clinical surveillance metrics (hospital admissions and clinical laboratory-positive cases) were complemented with wastewater and environmental monitoring (WEM) to monitor SARS-CoV-2 incidence. However, challenges in public health integration of WEM persist due to perceived limitations of WEM data quality, potentially driving inconsistent correlations variability and lead times. This study investigates how factors like population size, WEM measurement magnitude, site isolation status, hospital admissions, and clinical laboratory-positive cases affect WEM data correlations and variability in Ontario. The analysis uncovers a direct relationship between clinical surveillance data and the population size of the surveyed sewersheds, while WEM measurement magnitude was not directly impacted by population size. Higher variability in clinical surveillance data was observed in smaller sewersheds, likely reducing correlation strength for inferring COVID-19 incidence. Population size significantly influenced correlation quality, with thresholds identified at ∼66,000 inhabitants for strong WEM-hospital admissions correlations and ∼68,000 inhabitants for WEM-laboratory-positive cases during waned vaccination periods in Ontario (the Omicron BA.1 wave). During significant vaccination immunization (the Omicron BA.2 wave), these thresholds increased to ∼187,000 and 238,000, respectively. These findings highlight the benefit of WEM for strategic public health monitoring and interventions, especially in smaller communities. This study provides insights for enhancing public health decision making and disease monitoring through WEM, applicable to COVID-19 and potentially other diseases.
- 7 March 2025
- Published by American Chemical Society (ACS) in ACS ES&T Water
- Vol. 5 (4) , 1605-1619
Open AccessVariability of Clinical Metrics in Small Population Communities Drive Perceived Wastewater and Environmental Surveillance Data Quality: Ontario, Canada-Wide Study
The emergence of COVID-19 in Canada has led to over 4.9 million cases and 59,000 deaths by May 2024. Traditional clinical surveillance metrics (hospital admissions and clinical laboratory-positive cases) were complemented with wastewater and environmental monitoring (WEM) to monitor SARS-CoV-2 incidence. However, challenges in public health integration of WEM persist due to perceived limitations of WEM data quality, potentially driving inconsistent correlations variability and lead times. This study investigates how factors like population size, WEM measurement magnitude, site isolation status, hospital admissions, and clinical laboratory-positive cases affect WEM data correlations and variability in Ontario. The analysis uncovers a direct relationship between clinical surveillance data and the population size of the surveyed sewersheds, while WEM measurement magnitude was not directly impacted by population size. Higher variability in clinical surveillance data was observed in smaller sewersheds, likely reducing correlation strength for inferring COVID-19 incidence. Population size significantly influenced correlation quality, with thresholds identified at ∼66,000 inhabitants for strong WEM-hospital admissions correlations and ∼68,000 inhabitants for WEM-laboratory-positive cases during waned vaccination periods in Ontario (the Omicron BA.1 wave). During significant vaccination immunization (the Omicron BA.2 wave), these thresholds increased to ∼187,000 and 238,000, respectively. These findings highlight the benefit of WEM for strategic public health monitoring and interventions, especially in smaller communities. This study provides insights for enhancing public health decision making and disease monitoring through WEM, applicable to COVID-19 and potentially other diseases.
- Open Access
- 2 February 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology Letters
- Vol. 12 (2) , 124-129
Detection of Measles Virus Genotype A in a Non-Endemic Wastewater Setting: Insights from Measles Wastewater and Environmental Monitoring in Canada’s Capital Region
The recent global resurgence of measles in 2023-2024, despite vaccine preventability, underscores a critical public health issue, largely due to reduced vaccination coverage during the SARS-CoV-2 pandemic. In response, Ottawa Public Health intensified vaccination efforts in 2023 and 2024. Additionally, a research initiative began in April 2024 to monitor Ottawa wastewater for measles virus (MeV) using established wastewater and environmental surveillance (WES) protocols. Unexpected positive MeV detections through RT-qPCR in Ottawa wastewater-despite no active regional cases-prompted genotypic and retrospective analyses of archived RNA samples dating back to 2020. The genotypic analysis identified positive detection to belong to genotype A, the progenitor strain of the viral vaccines, marking the first report of MeV vaccine RNA in a large catchment area. Linear regression analysis revealed detections aligned with intensified vaccination efforts by Ottawa Public Health. These findings emphasize the importance of integrating genotypic analysis into WES practices to mitigate possible confounding factors, such as vaccine shedding into wastewater. Additionally, this research highlights potential public health applications using MeV WES as a complementary tool. Implementing the findings of this study for MeV WES, and for other re-emerging viruses, could improve public health response and resource allocation.
- 2 February 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology Letters
- Vol. 12 (2) , 124-129
Open AccessDetection of Measles Virus Genotype A in a Non-Endemic Wastewater Setting: Insights from Measles Wastewater and Environmental Monitoring in Canada’s Capital Region
The recent global resurgence of measles in 2023-2024, despite vaccine preventability, underscores a critical public health issue, largely due to reduced vaccination coverage during the SARS-CoV-2 pandemic. In response, Ottawa Public Health intensified vaccination efforts in 2023 and 2024. Additionally, a research initiative began in April 2024 to monitor Ottawa wastewater for measles virus (MeV) using established wastewater and environmental surveillance (WES) protocols. Unexpected positive MeV detections through RT-qPCR in Ottawa wastewater-despite no active regional cases-prompted genotypic and retrospective analyses of archived RNA samples dating back to 2020. The genotypic analysis identified positive detection to belong to genotype A, the progenitor strain of the viral vaccines, marking the first report of MeV vaccine RNA in a large catchment area. Linear regression analysis revealed detections aligned with intensified vaccination efforts by Ottawa Public Health. These findings emphasize the importance of integrating genotypic analysis into WES practices to mitigate possible confounding factors, such as vaccine shedding into wastewater. Additionally, this research highlights potential public health applications using MeV WES as a complementary tool. Implementing the findings of this study for MeV WES, and for other re-emerging viruses, could improve public health response and resource allocation.
- Open Access
- 7 October 2024
- Published by Elsevier in International Journal of Hygiene and Environmental Health
- Vol. 263, 114477
Sewer transport conditions and their role in the decay of endogenous SARS-CoV-2 and pepper mild mottle virus from source to collection
- 7 October 2024
- Published by Elsevier in International Journal of Hygiene and Environmental Health
- Vol. 263, 114477
Open AccessSewer transport conditions and their role in the decay of endogenous SARS-CoV-2 and pepper mild mottle virus from source to collection
- Open Access
- 7 July 2023
- Published by Springer Nature in Research Square
Impact of coagulation on SARS-CoV-2 and PMMoV viral signal in wastewater solids
Wastewater surveillance (WWS) has received interest from researchers, scientists, and public health units for its application in monitoring active COVID-19 cases and detecting outbreaks. While WWS of SARS-CoV-2 has been widely applied worldwide, a knowledge gap exists concerning the effects of enhanced primary clarification, the application of coagulant to primary clarifiers, on SARS-CoV-2 and PMMoV quantification for reliable wastewater-based epidemiology. Ferric-based chemical coagulants are extensively used in enhanced clarification, particularly for phosphorus removal, in North America, and Europe. This study examines the effects of coagulation with ferric sulfate on the measurement of SARS-CoV-2 and PMMoV viral measurements in wastewater primary sludge and hence also settled solids. The addition of Fe3+ to wastewater solids ranging from 0 to 60 mg/L caused no change in N1 and N2 gene region measurements in wastewater solids, where Fe3+ concentrations in primary clarified sludge represent the conventional minimum and maximum concentrations of applied ferric-based coagulant. However, elevated Fe3+ concentrations were shown to be associated with a statistically significant increase in PMMoV viral measurements in wastewater solids, which consequently resulted in the underestimation of PMMoV normalized SARS-CoV-2 viral signal measurements (N1 and N2 copies/copies of PMMoV). pH reduction from coagulant addition did not contribute to the increase in PMMoV measurements. Thus, this phenomenon is likely attributed to the partitioning of PMMoV particles to the solids of wastewater from the bulk liquid phase of wastewater.
- 7 July 2023
- Published by Springer Nature in Research Square
Open AccessImpact of coagulation on SARS-CoV-2 and PMMoV viral signal in wastewater solids
Wastewater surveillance (WWS) has received interest from researchers, scientists, and public health units for its application in monitoring active COVID-19 cases and detecting outbreaks. While WWS of SARS-CoV-2 has been widely applied worldwide, a knowledge gap exists concerning the effects of enhanced primary clarification, the application of coagulant to primary clarifiers, on SARS-CoV-2 and PMMoV quantification for reliable wastewater-based epidemiology. Ferric-based chemical coagulants are extensively used in enhanced clarification, particularly for phosphorus removal, in North America, and Europe. This study examines the effects of coagulation with ferric sulfate on the measurement of SARS-CoV-2 and PMMoV viral measurements in wastewater primary sludge and hence also settled solids. The addition of Fe3+ to wastewater solids ranging from 0 to 60 mg/L caused no change in N1 and N2 gene region measurements in wastewater solids, where Fe3+ concentrations in primary clarified sludge represent the conventional minimum and maximum concentrations of applied ferric-based coagulant. However, elevated Fe3+ concentrations were shown to be associated with a statistically significant increase in PMMoV viral measurements in wastewater solids, which consequently resulted in the underestimation of PMMoV normalized SARS-CoV-2 viral signal measurements (N1 and N2 copies/copies of PMMoV). pH reduction from coagulant addition did not contribute to the increase in PMMoV measurements. Thus, this phenomenon is likely attributed to the partitioning of PMMoV particles to the solids of wastewater from the bulk liquid phase of wastewater.