Matthew T. Bennett
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Matthew T. Bennett has a total of 89 co-authors. Here are the top co-authors by number of shared publications:
- Andrew D. Krahn
Division of Cardiology, Department of Medicine, University of British Columbia, Vancouver, British Columbia, Canada
4 shared publications Andrew D. Krahn
Division of Cardiology, Department of Medicine, University of British Columbia, Vancouver, Canada
3 shared publications- Jason G. Andrade
Vancouver General Hospital, University of British Columbia, Vancouver, Canada
3 shared publications Allan C. Skanes
Division of Cardiology, Department of Medicine, University of Western Ontario, London, ON, Canada N6G 2V4
2 shared publicationsGeorge J. Klein
Division of Cardiology, Department of Medicine, University of Western Ontario, London, ON, Canada N6G 2V4
2 shared publicationsLorne J. Gula
Division of Cardiology, Department of Medicine, University of Western Ontario, London, ON, Canada N6G 2V4
2 shared publications
Latest Publications
- Open Access
- 22 October 2026
- Published by Wiley in Journal of Cardiovascular Electrophysiology
Frequent Premature Ventricular Complexes and Catheter Ablation for Atrial Fibrillation
Background and Aims: Frequent premature ventricular complexes (PVCs) are often observed in patients undergoing ablation of atrial fibrillation (AF). However, the relationship between AF ablation and PVCs is uncertain. The purpose of this study was to examine the prevalence of frequent PVCs before and after catheter ablation of AF. Methods: This was a retrospective cohort study of patients undergoing ablation of AF at two tertiary centers. All patients undergoing initial or repeat ablation of AF were eligible. Patients were followed in AF clinics before and after ablation with routine ambulatory ECG monitoring. Results: The cohort consisted of 421 patients (mean 63 years, 33% female, 57% paroxysmal). At baseline, 18.4% and 4.7% had ≥ 1% and ≥ 5% PVCs respectively. In the 179 days post‐ablation, 9.0% developed new onset ≥ 1% PVCs, whereas 10.9% of patients had regression from ≥ 1% to < 1% PVCs. In the total follow up period of 2 years, there was a significant increase in the proportion of patients with ≥ 1% PVCs. Multivariable modeling revealed baseline PVC burden and hypertension as the only predictors of an increasing PVC burden in the post‐ablation period. Conclusion: Frequent PVCs are highly prevalent among patients undergoing AF ablation. However, there was no signal of an increase in frequent PVCs in the immediate post‐ablation period.
- 22 October 2026
- Published by Wiley in Journal of Cardiovascular Electrophysiology
Open AccessFrequent Premature Ventricular Complexes and Catheter Ablation for Atrial Fibrillation
Background and Aims: Frequent premature ventricular complexes (PVCs) are often observed in patients undergoing ablation of atrial fibrillation (AF). However, the relationship between AF ablation and PVCs is uncertain. The purpose of this study was to examine the prevalence of frequent PVCs before and after catheter ablation of AF. Methods: This was a retrospective cohort study of patients undergoing ablation of AF at two tertiary centers. All patients undergoing initial or repeat ablation of AF were eligible. Patients were followed in AF clinics before and after ablation with routine ambulatory ECG monitoring. Results: The cohort consisted of 421 patients (mean 63 years, 33% female, 57% paroxysmal). At baseline, 18.4% and 4.7% had ≥ 1% and ≥ 5% PVCs respectively. In the 179 days post‐ablation, 9.0% developed new onset ≥ 1% PVCs, whereas 10.9% of patients had regression from ≥ 1% to < 1% PVCs. In the total follow up period of 2 years, there was a significant increase in the proportion of patients with ≥ 1% PVCs. Multivariable modeling revealed baseline PVC burden and hypertension as the only predictors of an increasing PVC burden in the post‐ablation period. Conclusion: Frequent PVCs are highly prevalent among patients undergoing AF ablation. However, there was no signal of an increase in frequent PVCs in the immediate post‐ablation period.
- Open Access
- 12 September 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (9)
Electrical reconnection after Pulsed Field Ablation with a Circular Over the Wire Catheter in Atrial Fibrillation
- 12 September 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (9)
Open AccessElectrical reconnection after Pulsed Field Ablation with a Circular Over the Wire Catheter in Atrial Fibrillation
- 1 July 2025
- Published by Elsevier in Canadian Journal of Cardiology
- Vol. 41 (10) , 2007-2010
Finding the Optimal Strategy in the Treatment of Embolic Stroke of Undetermined Source in Patients with a Patent Foramen Ovale
- 1 July 2025
- Published by Elsevier in Canadian Journal of Cardiology
- Vol. 41 (10) , 2007-2010
Finding the Optimal Strategy in the Treatment of Embolic Stroke of Undetermined Source in Patients with a Patent Foramen Ovale
- 24 November 2024
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 36 (1) , 81-84
Air Pollution and Its Impact in Electrophysiology
- 24 November 2024
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 36 (1) , 81-84
Air Pollution and Its Impact in Electrophysiology
- Open Access
- 9 October 2024
- Published by Elsevier in Heart Rhythm O2
- Vol. 5 (11) , 762-763
Cost-reduction strategies for cardiac implantable electronic devices: Increased battery capacity and beyond
- 9 October 2024
- Published by Elsevier in Heart Rhythm O2
- Vol. 5 (11) , 762-763
Open AccessCost-reduction strategies for cardiac implantable electronic devices: Increased battery capacity and beyond
- 4 September 2023
- Published by Elsevier in Canadian Journal of Cardiology
- Vol. 39 (9) , 1163-1165
Not for the Faint of Heart: Environmental Influences on Cardiovascular Health
- 4 September 2023
- Published by Elsevier in Canadian Journal of Cardiology
- Vol. 39 (9) , 1163-1165
Not for the Faint of Heart: Environmental Influences on Cardiovascular Health
- Open Access
- 26 August 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (17) , 5558
Identifying Premature Ventricular Complexes from Outflow Tracts Based on PVC Configuration: A Machine Learning Approach
Background: Current inferences about the site of origin (SOO) of premature ventricular complexes (PVC) from the surface ECG have not been subjected to newer data analytic techniques that identify signals that are not recognized by visual inspection. Aims: The objective of this study was to apply data analytics to PVC characteristics. Methods: PVCs from 12-lead ECGs of a consecutive series of 338 individuals were examined by unsupervised machine learning cluster analysis, and indexes were compared to a composite criterion for SOO. Results: Data analytics found that V1S plus V2S ≤ 9.25 of the PVC had a LVOT origin (sensitivity 95.4%; specificity 97.5%). V1R + V2R + V3R > 15.0 (a RBBB configuration) likely had a LVOT origin. PVCs with V1S plus V2S > 12.75 (LBBB configuration) likely had a RVOT origin. PVC with V1S plus V2S > 14.25 (LBBB configuration) and all inferior leads positive likely had a RVOT origin. Conclusion: Newer data analytic techniques provide a non-invasive approach to identifying PVC SOO, which should be useful for the clinician evaluating a 12-lead ECG.
- 26 August 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (17) , 5558
Open AccessIdentifying Premature Ventricular Complexes from Outflow Tracts Based on PVC Configuration: A Machine Learning Approach
Background: Current inferences about the site of origin (SOO) of premature ventricular complexes (PVC) from the surface ECG have not been subjected to newer data analytic techniques that identify signals that are not recognized by visual inspection. Aims: The objective of this study was to apply data analytics to PVC characteristics. Methods: PVCs from 12-lead ECGs of a consecutive series of 338 individuals were examined by unsupervised machine learning cluster analysis, and indexes were compared to a composite criterion for SOO. Results: Data analytics found that V1S plus V2S ≤ 9.25 of the PVC had a LVOT origin (sensitivity 95.4%; specificity 97.5%). V1R + V2R + V3R > 15.0 (a RBBB configuration) likely had a LVOT origin. PVCs with V1S plus V2S > 12.75 (LBBB configuration) likely had a RVOT origin. PVC with V1S plus V2S > 14.25 (LBBB configuration) and all inferior leads positive likely had a RVOT origin. Conclusion: Newer data analytic techniques provide a non-invasive approach to identifying PVC SOO, which should be useful for the clinician evaluating a 12-lead ECG.
- 5 April 2023
- Published by Elsevier in Canadian Journal of Cardiology
- Vol. 39 (9) , 1253-1262
Air Pollution and Arrhythmias
- 5 April 2023
- Published by Elsevier in Canadian Journal of Cardiology
- Vol. 39 (9) , 1253-1262
Air Pollution and Arrhythmias