Sarit Kumar Das
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Sarit Kumar Das has a total of 158 co-authors. Here are the top co-authors by number of shared publications:
T. Sundararajan
Department of Mechanical Engineering IIT Madras 600036 Chennai- India
15 shared publications- Purbarun Dhar
Department of Mechanical Engineering Indian Institute of Technology Ropar 140001 Rupnagar- India
12 shared publications - Purbarun Dhar
Department of Mechanical Engineering, Indian Institute of Technology, Madras, Chennai 600036, India
11 shared publications - Anilakkad Raman Harikrishnan
Department of Mechanical Engineering, Birla Institute of Technology and Science Pilani 2 , Pilani, Rajasthan 333031
8 shared publications Arvind Pattamatta
7 shared publications- Sateesh Gedupudi
Heat Transfer and Thermal Power Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, India
7 shared publications
Latest Publications
- Open Access
An Efficient Microfluidic Platform for Organ-Specific Cyclic Multiaxial Loading and Differentiation of Progenitor Cells
Mechanical loading is a fundamental regulator of tissue development, maturation, and function, yet existing in vitro systems predominantly apply uniaxial load/strain to cell-laden hydrogels, limiting their ability to reproduce physiologically relevant multiaxial on-chip tissue mechanics. Here, we present an engineered system to apply controlled multiaxial mechanical loading to real scaffolds with undifferentiated cells. The system enables programmable cyclic stretching and relaxation at the cell scaffold level and is compatible with both cell-laden native scaffold and engineered soft tissues. We have quantified the strain field experienced by the tissue with distinct mechanical loading periods using computation simulations and validated these with systematic experiments, demonstrating reproducible and various organ-relevant multiaxial strain profiles. As proof of concept, we applied the approach to human cardiac tissues, where cyclic multiaxial mechanical loading of mononuclear cells laden native tissue scaffold promoted cardiac structural organization and supports the emergence of spontaneous contractile activity. This approach provides a generalizable method for reproducing physiologically relevant tissue mechanics in vitro and enables systematic investigation of mechano-regulation across a plethora of human tissues.
Open AccessAn Efficient Microfluidic Platform for Organ-Specific Cyclic Multiaxial Loading and Differentiation of Progenitor Cells
Mechanical loading is a fundamental regulator of tissue development, maturation, and function, yet existing in vitro systems predominantly apply uniaxial load/strain to cell-laden hydrogels, limiting their ability to reproduce physiologically relevant multiaxial on-chip tissue mechanics. Here, we present an engineered system to apply controlled multiaxial mechanical loading to real scaffolds with undifferentiated cells. The system enables programmable cyclic stretching and relaxation at the cell scaffold level and is compatible with both cell-laden native scaffold and engineered soft tissues. We have quantified the strain field experienced by the tissue with distinct mechanical loading periods using computation simulations and validated these with systematic experiments, demonstrating reproducible and various organ-relevant multiaxial strain profiles. As proof of concept, we applied the approach to human cardiac tissues, where cyclic multiaxial mechanical loading of mononuclear cells laden native tissue scaffold promoted cardiac structural organization and supports the emergence of spontaneous contractile activity. This approach provides a generalizable method for reproducing physiologically relevant tissue mechanics in vitro and enables systematic investigation of mechano-regulation across a plethora of human tissues.
- Open Access
- 14 September 2026
- Published by Elsevier in SSRN Electronic Journal
Beyond Shear Magnitude: Temporal Regulation of Mechanotransduction in Renal Epithelial Cells
Renal epithelial mechanotransduction is essential for maintaining tubular physiology by enabling epithelial cells to sense and adapt to their local mechanical environment, while disruption of these mechanosensitive processes may contribute to altered epithelial function during chronic kidney disease (CKD). Fluid shear stress (FSS) is a major regulator of renal epithelial mechanotransduction. However, most studies have focused on moderate-tohigh shear regimes (≈0.2-2 dyn/cm²), while the ultra-low shear conditions relevant to compromised renal function remain poorly understood. CKD is associated with reduced tubular flow, exposing epithelial cells to near-threshold shear stresses (~10⁻²-10⁻¹ dyn/cm²), where the mechanisms governing cellular adaptation remain largely unknown. In this study, we systematically investigated the combined influence of shear magnitude, exposure duration, and temporal continuity on renal epithelial mechanotransduction using a microfluidic platform. MDCK cells were exposed to static, intermittent, and continuous ultra-low shear conditions, and their responses were evaluated through intracellular calcium signaling, cytoskeletal organization (F-actin), nuclear response (DAPI), and quantitative morphological analysis over 0-12 h. Continuous flow consistently produced the strongest mechanobiological response, followed by intermittent flow and static culture, demonstrating that epithelial adaptation depends not only on shear magnitude but also on the duration and continuity of mechanical stimulation. A coordinated temporal progression was observed, beginning with calcium signaling, followed by cytoskeletal remodeling, nuclear response, and ultimately the development of a flow-adapted morphological phenotype. To quantitatively describe this behavior, a first-order mechanoadaptation model was developed to capture the temporal evolution of epithelial morphology and identify a characteristic adaptation timescale. Collectively, these findings demonstrate that sustained ultra-low shear stress is sufficient to induce significant renal epithelial adaptation and highlight the importance of shear magnitude, exposure duration, and flow continuity in regulating mechanotransduction under physiologically relevant low-flow conditions. The proposed experimental and quantitative framework provides new insight into epithelial adaptation in CKD and establishes a physiologically relevant foundation for kidney-on-chip platforms, disease modeling, and therapeutic screening.
- 14 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessBeyond Shear Magnitude: Temporal Regulation of Mechanotransduction in Renal Epithelial Cells
Renal epithelial mechanotransduction is essential for maintaining tubular physiology by enabling epithelial cells to sense and adapt to their local mechanical environment, while disruption of these mechanosensitive processes may contribute to altered epithelial function during chronic kidney disease (CKD). Fluid shear stress (FSS) is a major regulator of renal epithelial mechanotransduction. However, most studies have focused on moderate-tohigh shear regimes (≈0.2-2 dyn/cm²), while the ultra-low shear conditions relevant to compromised renal function remain poorly understood. CKD is associated with reduced tubular flow, exposing epithelial cells to near-threshold shear stresses (~10⁻²-10⁻¹ dyn/cm²), where the mechanisms governing cellular adaptation remain largely unknown. In this study, we systematically investigated the combined influence of shear magnitude, exposure duration, and temporal continuity on renal epithelial mechanotransduction using a microfluidic platform. MDCK cells were exposed to static, intermittent, and continuous ultra-low shear conditions, and their responses were evaluated through intracellular calcium signaling, cytoskeletal organization (F-actin), nuclear response (DAPI), and quantitative morphological analysis over 0-12 h. Continuous flow consistently produced the strongest mechanobiological response, followed by intermittent flow and static culture, demonstrating that epithelial adaptation depends not only on shear magnitude but also on the duration and continuity of mechanical stimulation. A coordinated temporal progression was observed, beginning with calcium signaling, followed by cytoskeletal remodeling, nuclear response, and ultimately the development of a flow-adapted morphological phenotype. To quantitatively describe this behavior, a first-order mechanoadaptation model was developed to capture the temporal evolution of epithelial morphology and identify a characteristic adaptation timescale. Collectively, these findings demonstrate that sustained ultra-low shear stress is sufficient to induce significant renal epithelial adaptation and highlight the importance of shear magnitude, exposure duration, and flow continuity in regulating mechanotransduction under physiologically relevant low-flow conditions. The proposed experimental and quantitative framework provides new insight into epithelial adaptation in CKD and establishes a physiologically relevant foundation for kidney-on-chip platforms, disease modeling, and therapeutic screening.
- 8 September 2026
- Published by Taylor & Francis in Heat Transfer Engineering
- p. 1-11
Organic Nanocoolant: An Environmental Friendly Solution for Battery Thermal Management in Electric Vehicles
The rapid adoption of electric vehicles (EVs) is a crucial step toward reducing greenhouse gas emissions and decreasing dependence on fossil fuels [1,2]. However, the performance, safety, and longe...
- 8 September 2026
- Published by Taylor & Francis in Heat Transfer Engineering
- p. 1-11
Organic Nanocoolant: An Environmental Friendly Solution for Battery Thermal Management in Electric Vehicles
The rapid adoption of electric vehicles (EVs) is a crucial step toward reducing greenhouse gas emissions and decreasing dependence on fossil fuels [1,2]. However, the performance, safety, and longe...
- Open Access
- 6 July 2026
- Published by Elsevier in SSRN Electronic Journal
Sustainable High-Heat-Flux Cooling Using a Novel Dual Radial Mini-Channel Heat Sink with a Deep Eutectic Solvent-Based Nanofluid
Efficient thermal management in advanced electronics processing is challenged by the limited heat dissipation of conventional systems and the high global warming potentials (GWP) of standard fluorocarbon coolants. This study presents a sustainable, high-performance alternative: a dual radial, multi-inlet and multi-outlet mini-channel heat sink with a 2 mm hydraulic diameter, cooled by a novel organic deep eutectic solvent (DES)- based nanofluid. The 2 mm channel scale was selected to balance high surface area density with manageable pressure and robust resistance to clogging from a nanoparticle suspension (hexagonal Boron Nitride, hBN) along with ease of manufacturing. Systematic computational dual radial multi-entry (DRME) geometry is designed to overcome the flow distribution and pressure drop penalties of conventional spiral layouts, ensuring exceptional temperature uniformity. The tailored DES nano-coolant, with an operating range of -12 to 188 °C and enhanced thermal conductivity and dielectric property, suppresses micro-scale boiling risks at high heat fluxes. Experiments demonstrate that the integrated system maintains the base plate temperature below 40 °C which is in strong agreement with computational predictions. Compared to a high-performance spiral mini-channel heat sink, the proposed multi-radial multi-entry design achieves a 125% higher thermal performance by reducing the required pumping pressure while improving temperature uniformity. This work provides a practical framework for designing eco-friendly, high-heat-flux cooling systems using engineered fluids in robust mini-channel architecture.
- 6 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSustainable High-Heat-Flux Cooling Using a Novel Dual Radial Mini-Channel Heat Sink with a Deep Eutectic Solvent-Based Nanofluid
Efficient thermal management in advanced electronics processing is challenged by the limited heat dissipation of conventional systems and the high global warming potentials (GWP) of standard fluorocarbon coolants. This study presents a sustainable, high-performance alternative: a dual radial, multi-inlet and multi-outlet mini-channel heat sink with a 2 mm hydraulic diameter, cooled by a novel organic deep eutectic solvent (DES)- based nanofluid. The 2 mm channel scale was selected to balance high surface area density with manageable pressure and robust resistance to clogging from a nanoparticle suspension (hexagonal Boron Nitride, hBN) along with ease of manufacturing. Systematic computational dual radial multi-entry (DRME) geometry is designed to overcome the flow distribution and pressure drop penalties of conventional spiral layouts, ensuring exceptional temperature uniformity. The tailored DES nano-coolant, with an operating range of -12 to 188 °C and enhanced thermal conductivity and dielectric property, suppresses micro-scale boiling risks at high heat fluxes. Experiments demonstrate that the integrated system maintains the base plate temperature below 40 °C which is in strong agreement with computational predictions. Compared to a high-performance spiral mini-channel heat sink, the proposed multi-radial multi-entry design achieves a 125% higher thermal performance by reducing the required pumping pressure while improving temperature uniformity. This work provides a practical framework for designing eco-friendly, high-heat-flux cooling systems using engineered fluids in robust mini-channel architecture.
- Open Access
- 22 April 2026
- Published by Elsevier in SSRN Electronic Journal
Investigation on the Influence of Flow Rate Ratio and Total Flow Rate on the Mixing Kinetics and Size-tunability of PLGA Nanoparticles in a Hydrodynamic Flow Focusing Microfluidic Device
Microfluidics has emerged as an innovative approach for tuneable and controlled formulation of nanoparticles, offering distinct advantages over conventional methods. Precise control of the physicochemical properties of nanoparticles is essential for optimising their therapeutic performance. In this study, we systematically investigate the influence of flow rate ratio (FRR) and total flow rate (TFR) on the formulation of Poly(lactic-co-glycolic acid) (PLGA) nanoparticles using a continuous hydrodynamic flow focusing (HFF) microfluidic platform and benchmark the outcomes against a conventional batch process. Mixing times under different flow conditions were quantified by computational fluid dynamics (CFD) analysis and validated experimentally to establish mechanistic links between microchannel mixing and the resulting nanoparticle properties. Our results show that increasing TFR and decreasing FRR shorten the mixing time, leading to the formation of smaller nanoparticles. PLGA NPs size decreased from 156.6 ± 2.56 nm to 128.9 ± 2.53 nm with an increase in TFR from 250 mL/min to 1000 mL/min while keeping the FRR constant at 0.05. While by increasing the FRR from 0.05 to 0.075 at a constant TFR of 250 uL/min PLGA NPs size increases from 156.6 ± 2.56 nm to 168.4 ± 2.46nm. This work highlights the critical role of flow parameters in governing nanoprecipitation kinetics and establishes a tuneable platform for the scalable production of PLGA nanoparticles with well-defined physicochemical properties for biomedical applications.
- 22 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessInvestigation on the Influence of Flow Rate Ratio and Total Flow Rate on the Mixing Kinetics and Size-tunability of PLGA Nanoparticles in a Hydrodynamic Flow Focusing Microfluidic Device
Microfluidics has emerged as an innovative approach for tuneable and controlled formulation of nanoparticles, offering distinct advantages over conventional methods. Precise control of the physicochemical properties of nanoparticles is essential for optimising their therapeutic performance. In this study, we systematically investigate the influence of flow rate ratio (FRR) and total flow rate (TFR) on the formulation of Poly(lactic-co-glycolic acid) (PLGA) nanoparticles using a continuous hydrodynamic flow focusing (HFF) microfluidic platform and benchmark the outcomes against a conventional batch process. Mixing times under different flow conditions were quantified by computational fluid dynamics (CFD) analysis and validated experimentally to establish mechanistic links between microchannel mixing and the resulting nanoparticle properties. Our results show that increasing TFR and decreasing FRR shorten the mixing time, leading to the formation of smaller nanoparticles. PLGA NPs size decreased from 156.6 ± 2.56 nm to 128.9 ± 2.53 nm with an increase in TFR from 250 mL/min to 1000 mL/min while keeping the FRR constant at 0.05. While by increasing the FRR from 0.05 to 0.075 at a constant TFR of 250 uL/min PLGA NPs size increases from 156.6 ± 2.56 nm to 168.4 ± 2.46nm. This work highlights the critical role of flow parameters in governing nanoprecipitation kinetics and establishes a tuneable platform for the scalable production of PLGA nanoparticles with well-defined physicochemical properties for biomedical applications.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- p. 1
A Biradial Multiple Entry Mini-channel Heat Sink for Processing Electronic Materials with an Organic Deep Eutectic Solvent (DES) Based Nano-coolant
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- p. 1
A Biradial Multiple Entry Mini-channel Heat Sink for Processing Electronic Materials with an Organic Deep Eutectic Solvent (DES) Based Nano-coolant
- 1 December 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (12)
Unraveling the dynamics of pulsatile flow under pathophysiological conditions in curved tubules of kidney
Chronic kidney disease (CKD) is a critical global health challenge that requires a deeper understanding of kidney physiology and pathology to develop effective therapeutic strategies. This necessitates a thorough exploration of fluid dynamic interactions within the elastic kidney tubules. This study introduces a biomechanical model to investigate the dynamics of fluid flow in elastic kidney tubules while incorporating their physiological curvature characteristics. We present a numerical model to analyze pulsatile flow dynamics in the kidney tubules, incorporating curvature and compliance variations. A finite-element framework is used to evaluate flow parameters across varying wall stiffnesses, with validation against data from the literature. Our findings highlight that both curvature and tissue stiffness significantly impact fluid dynamics. Higher stiffness reduces peak axial velocity, while convex regions exhibit greater velocity and fluid shear stress (FSS) than concave regions. Relative to straight tubules, curvature leads to greater than an order of magnitude decrease in FSS, with concave regions producing the most pronounced suppression. Increased stiffness further decreases wall displacement, reduces von Mises stress, and lowers FSS due to reduced compliance. The relationship between stiffness and FSS suggests that mechanical forces within the tubule microenvironment are strongly influenced by tissue elasticity. As CKD progresses, renal tubules become stiffer, which alters these mechanical forces that further alter fluid dynamics, and contribute to the pathological conditions of the tubule structure. The complex interrelationships among kidney architecture, fluid structure interaction, and pathology highlight the therapeutic importance of taking curvature into account when figuring out how kidney disease progresses and creating tailored treatments.
- 1 December 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (12)
Unraveling the dynamics of pulsatile flow under pathophysiological conditions in curved tubules of kidney
Chronic kidney disease (CKD) is a critical global health challenge that requires a deeper understanding of kidney physiology and pathology to develop effective therapeutic strategies. This necessitates a thorough exploration of fluid dynamic interactions within the elastic kidney tubules. This study introduces a biomechanical model to investigate the dynamics of fluid flow in elastic kidney tubules while incorporating their physiological curvature characteristics. We present a numerical model to analyze pulsatile flow dynamics in the kidney tubules, incorporating curvature and compliance variations. A finite-element framework is used to evaluate flow parameters across varying wall stiffnesses, with validation against data from the literature. Our findings highlight that both curvature and tissue stiffness significantly impact fluid dynamics. Higher stiffness reduces peak axial velocity, while convex regions exhibit greater velocity and fluid shear stress (FSS) than concave regions. Relative to straight tubules, curvature leads to greater than an order of magnitude decrease in FSS, with concave regions producing the most pronounced suppression. Increased stiffness further decreases wall displacement, reduces von Mises stress, and lowers FSS due to reduced compliance. The relationship between stiffness and FSS suggests that mechanical forces within the tubule microenvironment are strongly influenced by tissue elasticity. As CKD progresses, renal tubules become stiffer, which alters these mechanical forces that further alter fluid dynamics, and contribute to the pathological conditions of the tubule structure. The complex interrelationships among kidney architecture, fluid structure interaction, and pathology highlight the therapeutic importance of taking curvature into account when figuring out how kidney disease progresses and creating tailored treatments.
- 2 March 2025
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 32 (54) , 30188-30207
Exploring the potential of flow-electrode capacitive deionization for domestic and industrial wastewater treatment: a review
Flow-electrode capacitive deionization (FCDI) is an innovative approach for removing charged ions from untreated water, utilizing the interaction between ions and flow carbon electrodes. A review of recent publications on FCDI reveals a predominant focus on salt removal from water (desalination) and electro-sorption processes. Though desalination is just one step in improving the water quality, it is worthwhile looking at the research in the context of FCDI techniques that involve other water treatment methods. This paper offers a detailed review of recent literature on FCDI applications in wastewater treatment. Given the broad scope of wastewater treatment, the specific areas where FCDI shows promise, including removal of heavy metal and radioactive elements, organic micropollutant elimination, halogen removal, and resource recovery, are addressed. Additionally, we assess the current research landscape and propose potential future directions in this evolving field. Graphical abstract
- 2 March 2025
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 32 (54) , 30188-30207
Exploring the potential of flow-electrode capacitive deionization for domestic and industrial wastewater treatment: a review
Flow-electrode capacitive deionization (FCDI) is an innovative approach for removing charged ions from untreated water, utilizing the interaction between ions and flow carbon electrodes. A review of recent publications on FCDI reveals a predominant focus on salt removal from water (desalination) and electro-sorption processes. Though desalination is just one step in improving the water quality, it is worthwhile looking at the research in the context of FCDI techniques that involve other water treatment methods. This paper offers a detailed review of recent literature on FCDI applications in wastewater treatment. Given the broad scope of wastewater treatment, the specific areas where FCDI shows promise, including removal of heavy metal and radioactive elements, organic micropollutant elimination, halogen removal, and resource recovery, are addressed. Additionally, we assess the current research landscape and propose potential future directions in this evolving field. Graphical abstract
- 15 November 2024
- Published by ASME International in ASME Journal of Heat and Mass Transfer
- Vol. 147 (2) , 1-25
Insights Into Pool Boiling Heat Transfer on Minichannel Surfaces Through Point and Field Measurements
In this study, saturated pool boiling experiments were conducted on copper minichannel and flat surfaces at atmospheric pressure using water as the working fluid. The heat transfer performance was assessed through point measurements with a heater block, cartridge heaters, and thermocouples, as well as field measurements using a thin-foil heater and infrared thermography. Two copper minichannel surfaces with square cross sections of 1 mm (minichannel-1) and 2 mm (minichannel-2) side lengths were tested and compared to a flat surface. Minichannel-1 and minichannel-2 enhanced the critical heat flux (CHF) by 17% and 45%, respectively, and improved the heat transfer coefficient by 24–40% and 51–75%, respectively, compared to the flat surface. Minichannel-2 exhibited the lowest and most uniform boiling surface temperature, making it the best performer among the three. There was no significant change in departure frequency among the surfaces, and no significant change in departure diameter for the flat surface and minichannel-1. However, minichannel-2 had lower departure diameters due to its deeper channels, which prevented bubble coalescence and maintained low departure diameters. Additionally, minichannel-2 delayed vapor film formation by breaking it with its deeper fins, thereby improving CHF and slightly enhancing bubble dynamics. The enhancement in boiling heat transfer is primarily attributed to the increased surface area provided by the minichannels, with a minor contribution from improved bubble dynamics. However, the dominant factor in enhancing pool boiling heat transfer on minichannel surfaces is the increase in surface area.
- 15 November 2024
- Published by ASME International in ASME Journal of Heat and Mass Transfer
- Vol. 147 (2) , 1-25
Insights Into Pool Boiling Heat Transfer on Minichannel Surfaces Through Point and Field Measurements
In this study, saturated pool boiling experiments were conducted on copper minichannel and flat surfaces at atmospheric pressure using water as the working fluid. The heat transfer performance was assessed through point measurements with a heater block, cartridge heaters, and thermocouples, as well as field measurements using a thin-foil heater and infrared thermography. Two copper minichannel surfaces with square cross sections of 1 mm (minichannel-1) and 2 mm (minichannel-2) side lengths were tested and compared to a flat surface. Minichannel-1 and minichannel-2 enhanced the critical heat flux (CHF) by 17% and 45%, respectively, and improved the heat transfer coefficient by 24–40% and 51–75%, respectively, compared to the flat surface. Minichannel-2 exhibited the lowest and most uniform boiling surface temperature, making it the best performer among the three. There was no significant change in departure frequency among the surfaces, and no significant change in departure diameter for the flat surface and minichannel-1. However, minichannel-2 had lower departure diameters due to its deeper channels, which prevented bubble coalescence and maintained low departure diameters. Additionally, minichannel-2 delayed vapor film formation by breaking it with its deeper fins, thereby improving CHF and slightly enhancing bubble dynamics. The enhancement in boiling heat transfer is primarily attributed to the increased surface area provided by the minichannels, with a minor contribution from improved bubble dynamics. However, the dominant factor in enhancing pool boiling heat transfer on minichannel surfaces is the increase in surface area.